| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group-B |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 5 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as Required1 Pair |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 8 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 9 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 10 | Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 11 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 12 | Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required1 or 2 Module (75 mmX75 mm) |
| 13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 14 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 15 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 16 | Supplying of 20 W LED 6500 K Premium 20 W LED batten with \"Eye Soft\" technology & glarefree diffuser.(make compatible to Havells COMFY VIZON - LHEXARP7SN1W020 of Baja/ Anchor/ wipro/Havells. |
| 17 | Providing of LED Adore 10W B22 Cdl Ball Lamp make compatible to Havells LED Adore 10W B22 Cdl Ball Lamp cat no. LHLDDDEAIA5R010 of Bajaj / Anchor /Phillips /Havells. |
| 18 | Supplying and fixing of 36W LED 2x2 feet Ultra modern Slim recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling (35mm height). ( make compatible to Havells cat no- VENUS NEO 2X2 VENUSNEO2X2PLR36WLED865 G2 of Baja/ Anchor/ wipro/Havells. |
| 19 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (make Usha/Bajaj/Khaitan/crompton/Havells EPIC Colour Elegant white cat no FHCPI5SWHT48) |
| 20 | Providing and fixing of Exhaust fan 200 mm sweep exhaust fan with louvers including making good the damage, connection, testing, commissioning etc. as required. (make compatible to Havells cat no Ventil Air DX HS White FHVDXHSWHT08 of sha/Bajaj/ Khaitan /Havells) |
| 21 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 22 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 23 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A |
| 24 | Supplying and fixing following way , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 25 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
| 26 | Supplying of 4x50 Sqmm size of Aluminium Armoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade (make as available on Gem) |
| 27 | Supplying of 2x16 Sqmm size of Aluminium Armoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade (make as available on Gem) |
| 28 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm |
| 29 | Laying of one number additional PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm |
| 30 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface etc as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 31 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface etc as required.Above 35 sq. mm and upto 95 Sqmm(clamped with 25x3mm MS flat clamp) |
| 32 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 33 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as req. |
| 34 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 35 | SITC of Indoor type ground mounting , Double door, Feeder panel made up of 1.6mm CRCA Sheet, with double coating of zinc and synthatic enamel having size of 1500mm x 1200mm x 400mm deep contain Eight compartments of suitable size with locking arrangement including arrangement of incoming/ outgoing cable / cable termination/cable gland, earthing, locking, interconnections etc as required.. The panel must include following items (a) MCCB 250 Amps Four pole, braking capacity 38KA - 01 Nos (Incomer)(b) MCCB 63 Amps Four pole, braking capacity 38KA - 04 Nos (Outgoing)(c) 40mm x 10mm. Four pole, aluminium busbar including all accessories-1.7 Mtr(d) Ammeter, 0-300A, 50Hz, 415VAC 0-500A-1 nos(e) Voltmeter, 0-500VAC, 50 Hz-1 nos(f) Selector switch for ammeter-1 nos(g) Selector switch for voltmeter-1 nos(h) Indicator lamps for phase - 03 Nos(i) C curve 32 A DP MCB -08 Nos (outgoing) |
| 36 | Add GST Factor on DSR-22 items 12% to 18 % (1.0633) on amount |
| 37 | Add Labour cess on amount of serial no 01 to 30 of Rs. 798588.57 |
| 38 | Add modification factor of GST @0.973 on total amount of Rs. 987423.46/- (deduct amount of Rs. 26660.43/-) |