| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 2 | Providing and laying 60mm thick factory made cement concreteinterlocking paver block of M-30 grade made by block making machinewith strong vibratory compaction and of approved size and design/shapelaid in required colour and pattern over and including 50mm thickcompacted bed of fine sand, filling the joints with coarse sand etc. allcomplete as per direction of Engineer-in-charge. |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | 40mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 28mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 12mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 7 mm to 10mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix :3 marble chips) by volume including cement slurry and curing complete : 11.14.6 Ordinary cement without any pigment. |
| 5 | Supply & fixingof 40mm wide PVC strips for joints |
| 6 | Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete includingcuring but excluding the cost of centering, shuttering, finishing and reinforcement. Allworks upto plinth levelwith 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforcement for R.C.C work including straightening, cutting, bending , placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work for Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 12 | Steel work welded in built up section framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer. |
| 13 | Providing and fixing G.I Chain link Fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per direction of Engineer in Charge Made of G.I wire dia 4mm |
| 14 | Finishing wall with premium acrylic smooth exterior paint with siliconeadditives of required shade on New work (two or more coats applied @1.43 liter/10sqm over and including priming coat of water exterior paintapplied @ 2.20kg/10sqm) |
| 15 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 16 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge |
| 17 | Finishing walls with premium Acrylic smooth exterior paint with silicon additives of required shade: Old work (Two or more coats applied @ 1.43 liters/ 10 sqm)over existing cement paint surface |
| 18 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete |
| 19 | Renewing glass panes, including removal of broken glass with wooden fillets using Float glass panes of thickness 4.0 mm / 3 mm thick translucent white acrylic plastic sheet as per direction of Engineer Incharge |
| 20 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 21 | Applying priming coat: With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works |
| 22 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 23 | Dismantling of flushing cistern of all types(C.I/PVC/Vitreous china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 meters lead |
| 24 | Providing and fixing P.V.C low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete: |
| 25 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. |
| 26 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 27 | Supplying and fixing of ceiling fan offollowing sweep with 2.25 mfd condenser and 1\"-6\" down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. 1200mm dia sweep ceiling fan |
| 28 | Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. 225 mm / 9\" sweep exhaust fan |
| 29 | Supply & fixing600 mm x 600 mm size recessed mounted LED Luminaries 36 watt. havingminimum 3600 Lumens with minimum lumens efficiency 110 Lumens/watt (Commercial type) Firm has to submit originallity certificate of material from OEM or Authorized Distributor with 05 years of warranty. |
| 30 | Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding) 1HP |
| 31 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required2 X 2.5 sqmm |
| 32 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required2 X 1.5 sqmm |
| 33 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required 2 X 4sqmm |
| 34 | providing and fixing of LED lamp of 9w |
| 35 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12Module |
| 36 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8Module |
| 37 | supplying and fixing following Modular switch / socket on the existing modular plate 5/6 a switch |
| 38 | supplying and fixing following Modular switch / socket on the existing modular plate 15/16 A switch |
| 39 | supplying and fixing following Modular switch / socket on the existing modular plate 3 pin 5/6 A socket outlet |
| 40 | supplying and fixing following Modular switch / socket on the existing modular plate6 pin 15/16 A socket outlet |
| 41 | Installation, Testing and commissioning IP 67 Flood lights 200 wattminimum Luminous flux of luminaire 120 Lm/w, Colour temperature of 5700K, Neutral white, CRI > 80, 50,000 operating hours with PCLens and necessary wire for connection and other accessories required for fixing lights on existing Poles. Firm has to submit originallity certificate of material from OEM or Authorized Distributor with 05 years of warranty. |
| 42 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 43 | Supply installation testing and commissioning of IP:20 AluminiumBatten 36 W LED Wall Mounted 1200 mm with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K, CRI 80 .The LED should have life of 50000 Burning Hours at L70.The inputvoltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Firm has to submit Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab with 05 years of warrant |
| 44 | Providing and fixing G.I. pipes complete with G.I. fittings (external work) 50mm dia. nominal bore Medium |
| 45 | Providing and fixing G.I. pipes complete with G.I. fittings (external work) 25 mm dia. nominal bore Medium |
| 46 | Providing and fixing G.I. pipes complete with G.I. fittings(external work) 20 mm dia. nominal bore Medium |
| 47 | Providing and fixing G.I. pipes complete with G.I. fittings . (external work) 15 mm dia. nominal bore Medium |
| 48 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 50 mm nominal bore |
| 49 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 50 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal bore |
| 51 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15 mm nominal bore |
| 52 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 53 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 54 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 55 | Providing and fixing unplasticised PVC connection pipe with brass unions: 45 cm length 15 mm nominal bore |
| 56 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes 75 mm diametre |
| 57 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 58 | PROVIDING and laying Heavy Duty 6\" dia tyres for ladder |
| 59 | Providing and fixing 15cm wide 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. |
| 60 | Providing and Fixing Galavanised wire mesh of average width of aperture 1.4 mm and nominal dia. of wire 0.63 mm at Eveas level to protect entry of Pigeons including cost of wire mesh, screws, labour and scaffolding required complete job as per the direction of enginere incharge. |
| 61 | carriage of stone aggregate for a distance of 20 km by mt |
| 62 | Provision for supply and Installation ofPedestal for Inaguration / Foundation made of MS Frame with 4 mm thick ACP Sheet of and Acrylic Inaguration Plate covered with Acrylic Sheet as per direction of Engineer Incharge |