}

Tender For Operational And Maintenance Of The Swimming Pool And Other Miscellaneous Works At Ludlow Castle Wrestling Venue, Training Centre, Delhi-54, Delhi-Delhi

Public Works Department has published Tender For Operational And Maintenance Of The Swimming Pool And Other Miscellaneous Works At Ludlow Castle Wrestling Venue, Training Centre, Delhi-54. Submission Date for this Tender is 05-07-2025. Swimming Pool Construction Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

49898142
Tender For Operational And Maintenance Of The Swimming Pool And Other Miscellaneous Works At Ludlow Castle Wrestling Venue, Training Centre, Delhi-54
Tender
Indian
Delhi
Delhi
05-07-2025

Tender Documents

Tender Details

Operational And Maintenance Of The Swimming Pool And Other Miscellaneous Works At Ludlow Castle Wrestling Venue, Training Centre, Delhi-54- 1 Initial Filling of water in the Swimming pool of approximate 5,00,000 litre capacity after cleaning the pool by help of various acids through back-washing method including servicing of pumps, starter and other equipment’s etc. filling of pool with water, initial dosing of chemical and submission of 1st water test report approved from NABL to the Engineer-in-charge etc. complete as reqd. 2 Cleaning ,Running, Operation of Sand filter including check & refilled Sand for required mark and change the faulty ball valves or top mount plate etc complete as reqd. 3 Repair & Replacement of all types ofMS / GI / PVC/ CPVC / UPVC Pipes & Ball Valve / Gate Valve / NRV / Butterfly valve etc. with their accessories of Swimming pool Campus etc. complete as and when reqd. 4 Running, operation and upkeeping of swimming pool and plant including cleaning of deck area, bath room, drain channel and operation of suction sweeper to clean sedimentation settled at the bottom of the pool to keep the pool clean including replacement of nylone rope, nylone brushes etc. as and when required i/c maintenance and operation of 2 Nos. 10 HP filter pump and 2 Nos. 5 HP submersible pump for makeup of water complete etc as reqd as and when required, attending day to day complaints of electrical installations and compound lights including repairing the wiring and light fixtures complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc. on account of failure of above services for their proper functioning alongwith repair works, as and when required and recording reading in log book, keeping the entire installation on functional mode on all days of the month i/c Sunday and holidays by deploying following staff, maintaining the record i.e attendance Register, complaint register duly signed by the client and site Engineer as per direction of engineer-in-charge and as per terms and conditions attached.a) Operator- 3 Nosb) Khallasi - 2 Nos. c) Electrician - 1 No 5 Supplying and dosing of day to day chemicals for swimming pool consisting to maintain the water quality as per with the standards of swimming pool, including daily water testing by testing kits including keeping records (duly signed by the clinet and site Engineer) of PH Value and Chlorine Level of Pool-water as required at site with the following chemicals for the swimming pool. (For approximate 12 Lacs litres water capacity swimming pool) 6 HCL 7 Alum 8 Soda ash 9 CuS04 10 TCCA90 11 Monthly basis testing of swimming pool water from the reputed and Govt. recognized test laboratory i/c collection of water sample from pool, sending the sample to the lab and collection of report and submitting the test report to the site Engineer etc. complete as reqd. 12 Comprehensive Annual Maintenance contract and service charges for 55kw heat pump which includes supply and replacement of components found defective, servicing, repairing, rectification of condenser coil, cooling coil, thermostat relay, PCB, fan motor, electrical wiring, gas charging if found necessary including replacement / repairing of sealed compressors etc. complete as required. 13 Comprehensive Annual Maintenance contract and service charges for 1.5/2.0/4.0 TR Split type AC (invertor/non-invertor) units which includes supply and replacement of components found defective, servicing, repairing, rectification of condenser coil, cooling coil, thermostat relay, PCB, fan motor, electrical wiring, gas charging if found necessary including replacement / repairing of sealed compressors etc. complete as required. 14 Supply of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with remote for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 15 Supplying, Installation, Testing and Commissioning of 450 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd. 16 Supplying, installation, Testing & Commissioning of SWIMMING LED light (Round / Polycarbonate body / SS304) Operating temp range -15 deg to +40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating . complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required , . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy ≥105 and <120 lm/Watt output All as per pre approved by Engineer-in-charge. a) 54 watt 17 Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 18 12 -15 watt 19 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 20 18- 22 watt 21 Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 22 150 watt 23 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB complete with connections, testing and commissioning etc. as required. 24 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 25 mm 26 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as re uired. 27 3 x 1.5 sq.mm 28 3 x 4 sq.mm 29 3 x 6 sq.mm 30 Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 31 100 Amp , 16 KA, TPMCCB 32 125 Amp , 16 KA, TPMCCB 33 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 34 Single Pole 35 Double Pole 36 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 37 3 Module 38 6 Module 39 8 Module 40 12 Module 41 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 42 5/6 A switch 43 15/16 A switch 44 3 pin 5/6 amp socket outlet 45 6 pin 15/16 A socket outlet 46 Supplying and laying of following size XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 7098 (Part I) ISI on wall surface as required. (Clamped with 1 mm thick saddle/25x 3 mm MS flat clamp) 47 3 x 10 Sqmm 48 Lowering and Lifting of 5 to 10 HP three phase submersible -open well mono block pump set in existing under ground water tank with the help of chain pulley block and tripod stand along with GI pipe complete as reqd. 49 Rewinding, repair and servicing of following monoblock/ mono submersible pump set/ submersible pump set suitable for run 3 phase, 440volt, 50 Hz AC supply i/c dismental from existing locationand carriage (to and fro) to the workshop and testing, commissioning with credit of scrap copper wire and other parts etc.as required. 50 5 to 10 HP 51 S.I.T.C of 440 volt 50Hz, 3 Phase, semi autimatic star-delta stater panel suitable for 5/7.5/10 HP Open-well / borewell motor pump set having Ammeter, Voltmeter, Selector Switch, Single phase priventer etc as reqd.with credit of old dismentled material as reqd. 52 Supplying, Installation, testing of commissioning of 7.5 HP 440 Volt, 2900 RPM 8 stage Borewell submersible pump set capable of delivery of390 LPM at the head of 22meter directly coupled with submersible electric motor size 50 mm dia i/c GI pipe nipple, 50 mm flange, cable G.I pipe loweringmaking connection as reqd.i/c removing old pumpset trsting complete in all respect as reqd. 53 Supply, installation, testing and commissioning of Reverse Osmosis System with capacity of 250 LPH designed for Treatment of saline water in the TDS range of 500-2000ppm which are Completely assembled /Pre-piped/Pre-wired with Microprocessor-based control Pannel for ease of operation and inbuilt process Logic having provision for Auto start/stop based on Water level in the Tank with MCB for Plant operation and Raw water pump integrated with Plant. Integrated pretreatment Module for removal of suspended solids along with pressure gauges, Robust high Pressure Pump in SS 304 Construction, Inbuilt Protection to high Pressure Pump by Way of Low Pressure Switch/high Pressure switch and Glycerine filled SS Pressure gauges for durability, On line Rota meter for measuring permeate flow and Powder coated MS skid with plated hardware. RO plant have Pressure Sand Filter of 1000 LPH, Activated carbon Filter of 1000 LPH, Antiscalant Dosing System with tank capacity of 50 Litre, Micron cartridge filter of 5 micron, 10 long, High pressure pump of 1000 LPH , 1.2 KW, RO membrane of 4*40 - 1 Nos. of GE/Equivalent having backwash facility along with 1 Year Maintenance wrt Replacement of Micron Cartridge Filter and Antiscalant Chemical. The Company is having their NABL Accredited Lab Testing facilities in Delhi. Our Product Is ISO 9001 , Indian Medical Association Certified GC (Green Company) Mark BIS certificate,ISO 14001, ISO17025, ISO9001i/c credit for existing RO plant etc. as required. 54 Supplying, Installation, Testing & Commissioning of self contained storage type water cooler suitable for operation on 230 V single phase A.C. supply having following capacity per hour cooling capacity & storage capacity with SS304 stainless steel body, air circulation R-32/R-410 /R-407/ R134a Green Refrigerant with Scroll / rotary compressor with min 5 year OEM warranty of compressor, water over flow 1/2 BSP (connections) i/c MS Angle Iron Stand of suitable size, complete and other accessories i/c connection testing etc as reqd. 55 storage 150 ltr, cooling capacity 150 ltr per hr 56 Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body including trim 57 12 -15 watt

Key Value

Document Fees
Refer document
EMD
INR 82441.0 /-
Tender Value
INR 41.22 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail