}

Tender For Repair And Replacement O Lt Distribution Network System, Unserviceable Lt Ug Cable, Lt Joint Finding Faults, Lt Equipment, Control Gear, Lt Panel & Connected Items Including Load Balancing Of External Electric Supply Incl Fixing Of Stores In Do, gurgaon-Haryana

Military Engineer Services has published Tender For Repair And Replacement O Lt Distribution Network System, Unserviceable Lt Ug Cable, Lt Joint Finding Faults, Lt Equipment, Control Gear, Lt Panel & Connected Items Including Load Balancing Of External Electric Supply Incl Fixing Of Stores In Do. Submission Date for this Tender is 19-07-2025. Overhead Line Tenders in gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

49894462
Tender For Repair And Replacement O Lt Distribution Network System, Unserviceable Lt Ug Cable, Lt Joint Finding Faults, Lt Equipment, Control Gear, Lt Panel & Connected Items Including Load Balancing Of External Electric Supply Incl Fixing Of Stores In Do
Tender
Indian
Haryana
Gurgaon
19-07-2025

Tender Documents

Tender Details

Repair and replacement o LT Distribution network system, unserviceable LT UG Cable, LT joint finding faults, LT equipment, control gear, LT panel & connected items including load balancing of external electric supply incl fixing of stores in domestic area of AF stn Gurgaon Under GE (AF) Gurgaon NO 1; 1 Schedule-A (E/M Work) 2 Taking out old serviceable /unserviceable under ground cable of following sizes from trenches/poles /pipe/floor 16 Sqmm 3.5/4 core to 35 Sqmm 3.5/4 core . 3 Taking out old serviceable /unserviceable under ground cable of following sizes from trenches/poles /pipe/floor 50 Sqmm 3.5/4 core to 120 sqmm 3.5/4 core. 4 Taking out old serviceable /unserviceable under ground cable of following sizes from trenches/poles /pipe/floor 185 Sqmm 3.5/4 core to 240 sqmm 3.5/4 core. 5 Supplying , laying ,passing through pipe , connecting and testingUG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100volts grade of Following size (Note:- Excavation & earthwork etc shall be measured and paid sepretaly)all as specified and as directed by Engr-in-charge:- 6 XLPE Cable ofsize 16 Sqmm, 4 Core . 7 XLPE Cable ofsize 25 Sqmm, 3½ Core . 8 XLPE Cable ofsize 35 Sqmm, 3½ Core . 9 XLPE Cable ofsize 50 Sqmm, 3½ Core . 10 XLPE Cable ofsize 70 Sqmm, 3½ Core . 11 XLPE Cable ofsize 95 Sqmm, 3½ Core . 12 XLPE Cable ofsize 120 Sqmm, 3½ Core . 13 XLPE Cable ofsize 185 Sqmm, 3½ Core . 14 XLPE Cable ofsize 240 Sqmm, 3½ Core . 15 Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as sepecifiedand directed by Engr-in-Charge. 16 Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point complete as sepecifiedand directed by Engr-in-Charge. 17 Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete as sepecifiedand directed by Engr-in-Charge. 18 M&L for sand cushioning in trenches for protection of LT under ground cable including punning and consolidation complete as sepecifiedand directed by Engr-in-Charge. (Note:- punned sand shall be measured for the purpose of payment.) 19 Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete as sepecifiedand directed by Engr-in-Charge. 20 Supply and laying GI tube medium grade 80 mm bore, ISI marked complete as sepecifiedand directed by Engr-in-Charge. 21 All as per item No 10 here-in-before but 40 mm bore. 22 M&Lin repair for heat shrinkable jointing kit including suitable size of connectorcomplete all as per directed by Engr-in-charge. Note : Cost of necessary excavation and earth work , labour, Jointing kit complete, fixing charges & T&P including removing of grass/shrubs nearby the fault location shall be deemed to include in quoted rates) forthe following sizes :- 23 XLPE Cable of size 25 sqmm to 50 Sqmm x 3.5/4 core. 24 XLPE Cable of size 70 sqmm to 120 Sqmm x 3.5/4 core. 25 XLPE Cable of size 180 sqmm to 240 Sqmm x 3.5/4 core. 26 Supply and fixing aluminium thimble , cable glandand lux after disconnecting from panel and taking down burnt cable from panel of different location and cutting out the burnt portion of cable and extended the cable from cable loop, preparation of cable including necessary connection and testing complete (Note : (i)01 Job consisting of 04 Nos Lugs/thimble at one end of cable(ii) Rate of necessary earth work for opening of loop if requried at site are deemed to be included in the quoted rate.)of following sizes :- 27 16 Sqmm 4 core 1100 volt grade. 28 25 Sqmm 3.5 core 1100 volt grade. 29 35 Sqmm3.5 core 1100 volt grade. 30 50 Sqmm 3.5 core 1100 volt grade. 31 120 Sqmm 3.5 core 1100 volt grade. 32 180 Sqmm 3.5 core 1100 volt grade. 33 240 Sqmm 3.5 core 1100 volt grade. 34 M&L for load balancing of Single/three phase system at LT Panel upto Distribution box of any size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium tube terminal of any size and capacityall as specified and as directed by Engr-in-charge.Note : (i) Necessary eqpt and safety mesures reqd for load balancing arranged by the contractor without any extra cost. (ii)Cost ofNew aluminium tube terminal of any size as per site reqmt change under the job deemed to be included in the quoted rate (iii) Contractor shall also submit the written record of phase wise electric load on panels/transformer duly signed by contractor, JE & AGE. 35 M&L for LT insulator shackle type porceline , vitreous, white , brown or green insulator including one galvanised mild steel straps , washers , insulator bolts for 1100 volts 100 mm height , 115 mm dia complete all as specified and directed by Engr-in-Charge. 36 M&L for LT pin type porceline , vitreous, white , brown or green insulator including one galvanised mild steel spindal , washers , two galvanised iron washers and one galvanised iron nut100 mm height , 65 mm dia for 1100 voltscomplete all as specified and directed by Engr-in-Charge. 37 S&F in replacementLT volt meter (0-500)digitalsquire flush type of size96x96 mm including necessary addition/ alternationofpanel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable Volt meter complete as sepecifiedand directed by Engr-in-Charge. 38 S&F in replacement 1100 Volts grade LT Ammeter(0 - 300 A) digital squire flush & CT type with CTsincluding necessary addition/ alternationofpanel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete as sepecifiedand directed by Engr-in-Charge. 39 S&F in replacement 1100 Volts grade LT Ammeter(0 - 500 A) digital squire flush & CT type with CTsincluding necessary addition/ alternationofpanel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete as sepecifiedand directed by Engr-in-Charge. 40 M&L for Spray painting to LT panel board with synthetic enamel high glow paintIst gradeincluding preparation/cleaningof steel surfaces. complete as sepecifiedand directed by Engr-in-Charge. 41 S&F in replacement of MCCBs Adjustable thermal and adjustable maganetic release4/3poleincluding necessery fixing arrengement if reqd . & testing completeall as sepecifiedand as directed by Engr-in-Charge of following sizes:- 42 (a)100 Amps 4 Pole breaking capacity 35/36 KA completeall as sepecifiedand as directed by Engr-in-Charge. Make :Havells Cat Part No.420245 or equivalentmakes of L&T/HAVELLS/Scheneider 43 (b)160 Amps 4 Pole breaking capacity 35/36 KA completeall as sepecifiedand as directed by Engr-in-Charge. Make :Havells Cat Part No.420247 or equivalent makes of L&T/HAVELLS/Scheneider 44 (c)200 Amps 4 Pole breaking capacity 35/36 KA completeall as sepecifiedand as directed by Engr-in-Charge. Make :Havells Cat Part No.420218 or equivalent makes of.L&T/HAVELLS/Scheneider 45 (d)200 Amps 3 Pole breaking capacity 35/36 KAcompleteall as sepecifiedand as directed by Engr-in-Charge. Make :Havells Cat Part No.420278 or equivalentmakesof L&T/HAVELLS/Scheneider 46 (e)250 Amps 4 Pole breaking capacity 35/36 KA completeall as sepecifiedand as directed by Engr-in-Charge. Make :Havells Cat Part No.420279 ormakesof L&T/HAVELLS/Scheneider 47 (f)400 Amps 4 Pole breaking capacity 35/36 KA completeall as sepecifiedand as directed by Engr-in-Charge. Make :Havells Cat Part No.422021 or makes of .L&T/HAVELLS/Scheneider 48 (g)630 Amps 4 Pole breaking capacity 50 KA completeall as sepecifiedand as directed by Engr-in-Charge. Make :Havells Cat Part No.422023 ormakes of.L&T/HAVELLS/Scheneider 49 M&L for detecting of fault in 1100 Volt cable of any size upto 400 Sqmm 3.5 core laid in trenc fault locating machine comprising of surg generator pulse,ECHO fault locator with high frequency distance calculator etc and exposing the cable fault,removal of deteriated portion of cable , treating of cable and making the same ready for jointing work complete all as specified and directed by Engr-In-Charge. 50 Taking down existing old LT panel board/ LT feeder pillar box comprising of MCCB & switch fuse unit of any capacity and size includingbus bar ,ammeters, voltmeters etc after disconnectingall cable connection and removing from site complete all asdirected. 51 Supply, install, commissioning and testing of LT panel board double door outdoor type floor mounted of factory made powder coated made out of outside body of 3.15mm thick steel sheet and inside body 14 gauge steel sheet, locking arrangement, front side and rear side opening arrangement of suitable size, Incl mounted on Angle iron stand of size 50x50x6mm having minimum height 1.5 feet duly grouted or welded on floor. Aluminium bus bar TPN of 400A for MCCB to all feeders to consisting the following items.Note- The panel should be installed on PCC plinth of height 1.5 feet above gronud level and and base should be proper depth and the making of plinth amount included in this item. TheQuoted price of this Panel will also include following items and should accomodate in this panel (make of Panel- Universal switchgear/ Advance Switchgear):- :-(a) Incoming MCCB 200 Amp 35/36 KA 4pole-01 No (b) Changeover switch 200 Amp TPN -01 No (c) Outgoing MCCB 100 Amp 35/36 KA 4pole -03 No (d) Outgoing MCCB 63 Amp 35/36 KA 4pole -01 No (e) RYB indication for each incoming & outgoing supplies-01 set (f) Digital Voltmeter, amp meter, with CT’s &selector switch-01 set(g) Termination of all cables with suitable size thimble and glands-1 Job.(h) PCC 1:2:4 type B-1 300x300x500mm fdn block to four legs incl earth work. 52 Earthing complete with galvanised steel earth plate 600 x 600 x 6mm thick buired directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5mr below normal ground levelconnected togalvanised iron strip of size 25 x 3mm by means GI welding after tighten by bolts, nuts, check nuts and washersfrom earth pit to test point with protection GI pipe of size 40mm dia light grade and providing masonry enclosureand watering pipe of dia 40mm including wiremesh steel funnel, including watering arrangement 200 ltrs for each earth pitcomplete as specifed and directed by Engr-in-charge . Make of GI Pipe is Prakash/Jindal (Note : GI strip 7.5 mtr included in the quoted rate from earth pit to test point) 53 Dismantling of old/rusted GI wire/Stripcomplete at site from shade/building upto 20mtr height completeall as specified and as directed by Engr-in-charge 54 M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or fixed on wallof the building on insulator or PVC pipeor chases or buried in ground or fixed to polesor any other indicated situation for loop earthing etc as required of size 20 x 3 mm GI strip complete all as specified and directed by Engr-In-charge. 55 M&L for repair of earthing pit with brick work and PCC 1:3:6 including RCC pit cover of size 300x300mmx50mm thick with provision of opening handle complete including necessary watering, ramming and compact of soil near the earth pitcomplete all as specified and as directed by Engr-in-charge. 56 M&L for surface dressing and proper laying of XLPE electrical cable of any size and capacity nearby the LT Panel after disconnecting all incoming and outgoing connection complete including cleaning of grass nearby the LT Panel upto 2mtr all around , necessary earthwork as required all as specified and as directed by Engr-in-charge.(Note : Rate of necessary earthwork as required at site are deemed to be included in the quoted rate) 57 Disposal of old junk/garbage both solid and liquid through browser with Tactor with minimum 3cum capacity and disposal out from MOD land maximum distance 5 KM complete all as directed by Engr-in-charge. 58 Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connection of size 10 Sqmm 2 core including taking down old cable complete all as specified and as directed by Engr-in-charge. 59 M&L in repair for PCC pole , 9 mtr long,size 102 mm x 172 mm at top and 12mm x 279 mm at bottom class- 10 complete including excavation & earth work in soft / loose soil, PCC 1:4:8 type-D-2 in pole fdn & pole encased in PCC 1:3:6 type C-1 of size 0.75X0.75X1.20 meter complete as specifiedand directed by Engr-in-Charge. 60 Supply only Synthetic insulating mat of size 2Mx1Mx10mm thick ISI marked complete as sepecifiedand directed by Engr-in-Charge. 61 Supply only Synthetic insulating mat of size 2Mx1Mx12mm thick ISI marked complete as sepecifiedand directed by Engr-in-Charge. 62 M&L for re-stringing of ASCR conductor of any size/dia by removing sag in between the line including disconnecting ACSR conductor from both side to overhead line and rejoining after repair work complete all as specified and directed by Engr-in-Charge. 63 M&L for providing PVC rigid spacer for 4/5 line LT overhead line complete all as specified and directed by Engr-in-charge. 64 M&L for Change over switch of capacity 250 Amps , 415 Volts , 4 pole with sheet metal inclosure complete all as specified and directed by Engr-in-charge. 65 M&L for Change over switch of capacity 400 Amps , 415 Volts with sheet metal inclosure complete all as specified and directed by Engr-in-charge. 66 M&L for Change over switch of capacity 630 Amps , 415 Volts , 4 pole with sheet metal inclosure complete all as specified and directed by Engr-in-charge. 67 M&L for side handle main switch 3 pole 415 volt 200 Amp complete all as specified and directed by Engr-in-charge. Make - Havells/L&T/ABB. 68 M& L for prunning of trees over the ACSR Conductor and all E/M Installations includingtrimming of tree in the radius of 2.5 mtr from ACSR conductor and its disposal complete all as directed by the Engr-in-Charge in consultation with users. 69 Supply and fixing in replacement ofstay assembly complete with 16mm dia stay Rod including PCC 1:3:6 type C-2 complete all as specified and as directed by Engr-in-charge. (Excavation and earth work measured and paid seperately). 70 S&F danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters,figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size ,for LT ,20X15 cm size complete all as specified and as directed. 71 M&L for preparation of old painted surface of electric RCC pole by removing all dirt, dust etc and apply approved colour one coat of syhnthetic enemal paint upto 1.5 mtr height (Five layer 30 cm Blue and 30 cm White one over another) and one coat of synthetic enamel paint on steel surface such as cross arm including writing of identification No , etc complete all as specified and directed. 72 All as per item No 49 herein beforebut one coat of aluminium paint on steel tubular pole. 73 M&L for shifting of electric panel from one place to another as directed by engineer in charge includes all necessary PCC work,earth work,diconnection and connection of cables properly ,using lugs ,thimbles complete 74 M&L for steel tubular swaged pole complet with cast iran base plate, finial taper plug, bolt, nut, screws as specified type 410- SP-31 (9mtr long), incl earth work and PCC 1:3:6in pole foundation and PCC 1:2:4 in coppingcomplete all as specified and directed by engineer in charge 75 M&L forPCC 1:2:4Type B2(40mm graded aggregate ) in foundation / allaround the panel which includingearth work reqdcomplete all as specifiedand as directed by engr-in-charge 76 M&L forPCC 1:2:4Type Bo(12.5 mm graded aggregate ) in foundation / allaround the panel omplete all as specifiedand as directed by engr-in-charge 77 Note:- The amount of Rs 185771/- against Schedule of Crediton Srl Page 140 & 141 shall be deducted from the total amount quoted against Sch A

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail