}

Tender For Requirement Of C And S Make Spares For Lt Swgr, Esp And Dc System, River Water System And Chp Of Unit-I To Iv Of Ctpp Chhabra - Switch Disconnector Fuse Unit, Ith-25A, Ue-415 V,50 Hz Ith-25A, Ue-415 V,50 Hz Ith-32A, Ue-415 V,50/60 Hz Ith-63, Baran-Rajasthan

Rajasthan Rajya Vidhyut Utpadan Nigam Limited has published Tender For Requirement Of C And S Make Spares For Lt Swgr, Esp And Dc System, River Water System And Chp Of Unit-I To Iv Of Ctpp Chhabra - Switch Disconnector Fuse Unit, Ith-25A, Ue-415 V,50 Hz Ith-25A, Ue-415 V,50 Hz Ith-32A, Ue-415 V,50/60 Hz Ith-63. Submission Date for this Tender is 14-07-2025. Overhead Line Tenders in Baran Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

49892521
Tender For Requirement Of C And S Make Spares For Lt Swgr, Esp And Dc System, River Water System And Chp Of Unit-I To Iv Of Ctpp Chhabra - Switch Disconnector Fuse Unit, Ith-25A, Ue-415 V,50 Hz Ith-25A, Ue-415 V,50 Hz Ith-32A, Ue-415 V,50/60 Hz Ith-63
Tender
Indian
Rajasthan
Baran
14-07-2025

Tender Documents

Tender Details

Tender For Requirement Of C And S Make Spares For Lt Swgr, Esp And Dc System, River Water System And Chp Of Unit-I To Iv Of Ctpp Chhabra - Switch Disconnector Fuse Unit, Ith-25A, Ue-415 V,50 Hz Ith-25A, Ue-415 V,50 Hz Ith-32A, Ue-415 V,50/60 Hz Ith-63A Ue-690 V, 50 HZ. 415 V Ith-125A, Ue-690 V, 50 HZ, 415 V Ith-200A, Ue-690 V, 50 HZ, 415 V Ith250A, Ue-690 V, 50 HZ, 415 V Ith-400A,Ue-690 V,50Hz Size-0-2 th-630A,Ue-415 V,50Hz, AC22A:6304, AC23A:630A, I5 13947-3/Лес 60947-3, Frame-Fr4, Three Pole. Power Contactors. 16A-AC3, 3 Pole, Coil Voltage-110V AC 16A-AC3, 3 Pole, Coil Voltage-110V AC 32A-AC3, 3 Pole, Coil Voltage 110V AC 32A-AC3, 3 Pole, Coil Voltage-110V AC 40 AC3, 3 Pole, Coil Voltage 110V AC 40A-AC3, 3 Pole, Coil Voltage-110V AC 50A-AC3, 3 Pole, Coil Voltage-110V AC 63A-AC3, 3 Pole, Coll Voltage-110V AC 80A-AC3, 3 Pole, Coil Voltage 110V AC BOA-AC3, 3 Pole, Coil Voltage 110V AC 115-AC3, 3 Pole, Coil Voltage 110V AC 185A-AC3, 3 Pole, Coil Voltage-110V AC 225A-AC3, 3 Pole, Coil Voltage 110V AC 265A-AC3, 3 Pole, Coil Voltage 110V AC 400A-AC3, 3 Profe, Coil Voltage 110V AC 330AC3, 2-Pole, Col Vokage 240V AC 7A-AC3, 3 Pole, Coil Voltage 415VAC BA-AC3, 3 Pole, Coil Voltage-415VAC Auxillary Contactor 10A/2NO+2NC, Coil Supply 110V AC 10A/4NO, Coil Supply 110V AC 10A/2NO 2NC, Coil Supply 110V AC 10A/ 2NO+2NC, Coil Supply 220V DC 10AMINO, Coil Supply 220V DC 10A/3NO+1NC. Coil Supply 220V DC 10A/2NO+2NC. Coil Supply 48V DC Spare Main Contact Kit For Power Contactors. For 115A (LCIFDP115AF5) For185A (LC1FDP185AF5) For Code-LC1-FDP225A For Code LC1-FDP265A For Code LC1-FDP400A For Code-LC1+DP3302A Spare Coils for Power Contactor For Code LC1-FDP3302A, Coil Voltage-240 V AC For Code-LC1-0803, Coil Voltage -110V AC For 115A (LC1FDP115AF5) For 185A (LC1FDP185AF5) For 265A (LC1FDP265AF5) For 400A (LC1FDP400AF5) Add On block Front Mounted/2NO+2NC Front Mounted/4NO Front Mounted/2NO+2NC Thermal O/L. Relays. (,63-1A) (.63-1A) 1-1.6A 1.6-2.5A 2,5-4A 5,5-8A 7-10A 10-13A 13-18A 18-25A 23-32A 28-40A 48-57A 57-66A 65-105A 80-125A 100-160A 125-200A Mounting kit for thermal overload relays, For 0.4-25A For 23A-36A For 23A-93A Push Buttons, Flush spring return push button with 1 NO block, Green colour. Flush spring return push button with 1 NO block, Yellow colour. Mushroom Head push button, Stay put(Press to Lock, Trun to Release) with 1 NC Block, Red colour. Flush spring return push button with 1 NO block, Red colour, Flush spring return push button with 1 NO block, Black colour. Push button with 2NO block Push button with INC block Modules Spares. Drawout fix (Male) contact (Main bus side) 125A for New modules, (1 sets 3 nos,) Drawout Moving (Female) contact set (Module side) 125A for New modules, (1 sets=3 nos,) Drawout fix (Male) contact (Main bus side) 400A for old modules, (1 sets=3 nos.) Drawout Moving (Female) contact set (Module side) 400A for old modules, (1 sets=3 nos,) Drawout fix (Male) contact (Main bus side) 250A for new modules, (1 sets 3 nos.) Drawout lix (Male) contact (Main bus side) 400A for new modules, (1 sets=3 nos,) Drawout Moving (Female) contact set (Module side) 250A for new modules, (1 sets=3 nos.) Drawout Moving (Female) contact set (Module side) 400A for new modules. (1 sets=3 nos.) Drawout fix (Male) contact (Main bus side) 630 A for existing modules. (1 sets=3 nos.) Drawout moving (Female) contact set (Module side) 630 A for existing modules (1 sets-3 nos,) Modules Rack in-Rack out bolt assembly. OFL Reset Cord 300MM Module door hing Steel (male & Female), MPCB(MOTOR PROTECTION C.B.) (P65 CATEGORY 440 VAC with thermal and magnetic release with 1NO+1NC, led trip indication range: 22-32A 440 VAC with thermal and magnetic release with 1NO+1NC, led trip indication | range: 28-40A 440 VAC with thermal and magnetic release with INO+1NC, led trip indication | range: 80-100A Motor Operator MCCBS Motor Operator (100-240VAC/100 220VDC) Motor Operator (230VAC/220VDC) Spare Handle CSSDF630-800A Off delay timer: 0,1 to 30 sec ACBs Spares FRP Safety Shutter Assenbly For AH-BD-CS,3P Auxiliary Isolating Contact Assembly For AH-08D-CS 3P HARDWARE KIT For AH-08D-CS Arc Chutes For 6D-16D/08N-20N(AHA) Auxxiliary Switch 14 way (7NO+ 7NC) for 20D-40D/30N-10S 14 way (7NO+7NC) for 60-160/08N-205 Tripping Coil/Shunt Trip 220V DC for 200-400/30N-40S(AHA) 220V DC for 6D-16D/08N-20S(AHA) Closing Coil 220V DC for 200-400/30N-40S(AHA) 220V DC for 6D-16D/08N-20S(AHA) 48V DC for 60-120 (AH) Spring Charged Indication Switch For 60-160/6N-205 Arcing Contacts (Set of 1 No. Fixed 1 No, Moving) For 80 Trip Indication Switch (For both manual and Fault indication in ACB) For 200-400/25S-40S For 60-160/6N-20S Drawout Mould Base For 6D-16D/6N-20S For 25D/305 For 400 Main Isolating contacts (Jaw Contacts) For 60-80/10N For 30D/405 For 400 Single Pole Assembly For 30D/40S For 1250A breaker type AH-12D-CS Charging Motor, 220V DC For 6D-16D/6N-20S (AHA) For 200-400/30S-40S (AHA) Micro Switch for Motor cut off For 60-40D/6N-40S Anti Pumping Relay For 6D-16D/6N-20S, 3P Main Fix Contacts (Upper Terminals) For 6N-10N Breaker rack-in rack-out handle For 800-1250A ACBs. For 3200-4000A ACBs, Lower Mechanism For AH-08D-CS For AH-40D-CS Drawout gear assembly For 6D-16D Dowel Pin For AH-40D-CS For AH-12D-CS For AH-08D-CS 16.5 kV IPBD spares (Transformers) 1FS-9FS PT flange fuse (24kV, 6.3A) Type-FT36 Rubber bellow (Ø920)

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 49.15 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail