Defence Government Departments Closing in 0 days TDR #49891362

Tender For Construction Of 08 Bedded Mahila Barrack At 356 Coy Level Bop Along Indo Pak Border Ipb And Indobangladesh Ibb Sh Electrical Work At Bop Lafasail Of 16 Bn Bsf Under Shq Bsf Silchar M And C Ftr

Issued by Government Departments · Karimganj, Assam
Tender Value
7.61 Lakhs
Estimated cost
Bid Submission
04 Jul 2025
0 days left
EMD
15233
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Karimganj → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of 08 Bedded Mahila Barrack At 356 Coy Level Bop Along Indo Pak Border Ipb And Indobangladesh Ibb Sh Electrical Work At Bop Lafasail Of 16 Bn Bsf Under Shq Bsf Silchar M And C Ftr

BOQ

Name of Work:C/O08 bedded Mahila barrack at 356 CoY level BOP along Indo-Pak border (IPB) and Indo-Bangladesh Border (IBB) (Sh: Electrical work at BOP Lafasail of 16 BN BSF under SHQ BSF Silchar, M&C Ftr)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
2Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
3Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
4Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
52 X 6 sq. mm + 1 X 6 sq. mm earth wire.
6Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair(Make : Havells / Polycab/ R R KABEL / Finolex )
7Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
8Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(i) 20 mm
925 mm
10Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
12Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
13Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.(i) 1 or 2 Module (75 mmX75 mm)
14Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. i)5/6 amps switch
153 pin 5/6 amp socket outlet
16Telephone socket outlet
17TV antena socket outlet
18Supplying and fixing PVC batten/ angle holder including connection etc. as required.
19Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
20Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
21Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)(i) 16 way Double door
22Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(i) Single pole
23Double Pole
24Supplying and fixing Cable End Box (Loose wire box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. (i) For 14 way, Double door SPN MCBDB
25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.de/loom solar/ushaor equivalent make)
26Supplying and fixing call bell/buzzer suitablefor single phase 230 volts, complete as required as per the direction of engg -in- charges.
27Earthingwith GI earth pipe4.5 metre long x 40 mm dia including accessories and providing masonry enclosure with cover platehaving locking arrangement and watering pipe etc. (with charcoal or coke and salt)as required
28Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
29Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required.
30Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
31Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
32Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
33Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
34Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
35Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
36Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required
37Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
38Providing and fixing circular/ hexagonal g.i. Box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick g.i. Sheet with its top surface hacked for proper bonding, top lid shall be screwed into the g.i. Box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia m.s. Bar bent to shape as per standard drawing. (dsr civil-2023 item no. 10.18)
39Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. (i) 2 x 25sq. mm (22 mm)
403½ X 50 sq. mm (35mm)
41Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
42Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. Direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc complete as required. (REX Polyextrusion / Jain Irrigation / Duraline / Avadh Polytube/ Gemini make) (i) 63 mm dia (OD-63 mm & ID-51 mm nominal)
43Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. i) upto 35 sq. mm
44Above 35 sq. mm and upto 95 sq. mm
45Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required i) upto 35 sq. mm
46Above 35 sq. mm and upto 95 sq. mm
47Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia pipes.
48S/I/T/C of 20 Watt, 6500 K LED batten Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with LED inbuilt driver (make : Havells, model :pride essential/Crompton /Bajaj/orient) including connection etc as required.
49S/I/T/C of 10 Watt, 6500 K LED batten Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with LED inbuilt driver (make : Havells, model :pride essential/Crompton /Bajaj/orient) including connection etc as required.
50Supplying and fixing of10 Watt, 3 star rating (B-22 base) LED bulb(make : Havells/CG/Bajaj/Philips)
51SITC of 12 Watt , 6500 K surface mounted round/Square shaped LED surface mountedlED panel with premium diffuser to ensure glare free & even light distribution make HavellsModel TRIM COSMO SURFACE ROUND 12 Watt, 6000 Kor compatable make of Bajaj/Philips/CG/orienti.c connection etc as required.
52SITC of 100 Amp/415 Volt busbar chamber in the existing wall, including connection etc as required as per direction of engg in Charge (Make- Benlo code BEBB100, or equivalent in Havells/HPL/L&T/C&S)
53Supplyingandfixingof 10 watt wall bracket LED light having IP 66mounting on wall/Surface including connection etc as required, (Make Havells/Philips/Crompton/)etcasperdirectionofengineer-in-charge
54Desigining,Fabrication Supply/ installation/ testing and commissioning of compartmentalised type outdoor feeder piller, double door made out of 2.03 mm thick CRCA powdered coated sheethaving 200 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front & back openable door with proper hinges, R-Y-B LED indicators and P & F of internal connection with suitable size of copper wires, following accessories & angle iron frame of suitable size with 600 mm long legs made out of 50 mm x 50 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming & outgoing cables, cable termination, earthing, locking, interconnection etc. as required. (CPRI Approved builder). The each feeder pillar should have Indicating lamp (LED type) 22.5 mm 230 volt AC Red, Yellow and blue make L&T/Havells/simens- 03 nos, CT Ratio (Amp) 100/05, accuracy class 1, burden 05 VA - makeL&T/AE/Trinity -03 nos, Digital Multifunction meter (VAF + PF) make L&T Cat no. WC411011OOOO or equivalent in AE/Siemns- 01 No,Earth studs on both side.
55Providing and fixing of 100 Amps, 4 pole, 415 volts, 50 Hz 18 KA breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.make L&T/ Havells/ABB as per the direction of Engg in charge
56Providing and fixing of 63 Amps, 4 pole, 415 volts, 50 Hz 18 KA breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.make L&T/ Havells/ABB as per the direction of Engg in charge
57Supplying and fixing 63 Amp, double pole, 240 volts, C series MCBin the existing DB/Panel complete with connections, testing and commissioning etc. as required. make L&T/ Havells/ Siemns/ ABB as per the direction of Engg in charge
58Supplying and fixing 125 Amps, 4 pole, 415 volts, 50 Hz on load change overswitch(open execution) in the existing Panel complete with connections, testing and commissioning etc. as required. make Socomec code 41G14013A or equivalent in L&T/ Havells/ Siemns/ ABB
59Supplying, Installation, testing and commissioning of followingsingle phase 2400 VA, 12/24 Volt Pure Sine wave Inverterand 02 Nos 150 AH Lead acid tubular battery (05 year full replacement warranty). The whole system will mounted on container having seperate compartment for both batteries and inverter also completed with connections etc as required as per the direction of Engg in charge. Detailed dwescription 1.BATTERY - 02 Nos (i) 150 Ah , 12 volt lead acid tubular Battery ( 05 Years full replcement warranty Battery) (ii) Make : luminious/exide/UTL/Genus Power or simillar specification2. INVERTER ACCESSORIES (i) Nominal Capacity: 2400 VA,12/24 volt (2 years warranty)(ii) Make : Luminus/exide/UTL/Genus Power simillar 3. Trolley 01 Nosspecification
60SITC of 3 Wattaluminium made wall mounted LED flexible reading light suitable for 230 Volt 50 HZ AC incuding with connection etc as required as per the direction of Engg in charge supply make Philips/Havells
61Installation of electrical sanitary napin incinirator machine with smoke control unit on existing wall complete as required as per direction of Engg in charge
62SITC of 240V, 50 HZ 1200 mm Sweep Ceiling Fan, having 02 Nos Canopy including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required of(make : Orient, model : Rapid Air/Bajaj/ usha/ Crompton/ Havells) including connection etc as required.
63SITC of 240V, 50 HZ 900 mm Sweep Ceiling Fan, having 02 Nos Canopy including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required of (Make : Havells,Model : Cool Breeze /Bajaj/Usha/Crompton)
64SITC of 300 mm Medium Duty Exhaust fan.complete including with connection, testing, commissioning etc. as required.(Make : Orient, model spring air medium duty exhaust fan/Havells/USHA/ Crompton/Bajaj)
65Add GST difference Multification factor (0.0633) on DSR Items (Srl no-01 to 31 and 33 to 37).

AI Tender Summary

OUR REF NO 49891362
AUTHORITY Government Departments
TENDER VALUE 7.61 Lakhs
LAST DATE 04-07-2025
Authority
Authority Name Border Security Force
Work Description Construction Of 08 Bedded Mahila Barrack At 356 Coy Level Bop Along Indo Pak Border Ipb And Indobangladesh Ibb Sh Electrical Work At Bop Lafasail Of 16 Bn Bsf Under Shq Bsf Silchar M And C Ftr
Basic Detail
Tender No 02 NIT Engg FTR M and C Elect 2025 26
Bidding Type Tender
Location
City Karimganj
State Assam
Key Dates
Publish Date 27 Jun 2025
Submission Date 04 Jul 2025
Open Date 07 Jul 2025
Finance
Tender Value 7.61 Lakhs
Tender Fee Ref. Documents
EMD 15233
Exemption Not Available
Document List
nit.pdf
Tendernotice_1.pdf
337ffb45-6e72-4840-9bd0-8f5a39ab28db.html
BOQ_910964.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 27, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 04, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 07, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

nit.pdf

pdf

Tendernotice_1.pdf

html

337ffb45-6e72-4840-9bd0-8f5a39ab28db.html

xls

BOQ_910964.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail