Rural Development Government Departments Closing in 0 days TDR #49879315

Tender For Construction/Retrofitting Of Pws Scheme At Kargaon, Tal. Jaoli, Dist- Satara

Issued by Government Departments · jaoli, Maharashtra
Tender Value
1.21 Crore
Estimated cost
Bid Submission
18 Jul 2025
0 days left
EMD
1.21 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jaoli → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction/Retrofitting Of Pws Scheme At Kargaon, Tal. Jaoli, Dist- Satara

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Jul-2025 3rd call Date 18-Jul-2025

BOQ

Name of Work: RETRO FITTING TO PWSS AT KARGAON AMBAWADE (BAMNOLI) , TAL-JAOLI,DIST-SATARA
Sl. No. Item Description
1RCC Chamber 1.5 M X 1.5 M X 1 M - 11 Nos
2Item No.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
3Item No.2 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
4Item No.3Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) For slab / Wall
5Item No.4 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
6Item No.5 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
7Item No.6Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto 1.20m with precast RCC slab cover
8RCC Chamber 1.5 M X 1.5 M X 1 M - 2 Nos Item No.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
9Item No.2 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
10Item No.3Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) For slab / Wall
11Item No.4 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
12Item No.5 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
13Item No.6Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto 1.20m with precast RCC slab cover
14RCC Chamber 1.5 M X 1.5 M X 1 M - 3 Nos Item No.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
15Item No.2 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
16Item No.3Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) For slab / Wall
17Item No.4 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
18Item No.5 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
19Item No.6Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto 1.20m with precast RCC slab cover
20RCC Chamber 1.5 M X 1.5 M X 1 M - 4Nos Item No.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
21Item No.2 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
22Item No.3Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) For slab / Wall
23Item No.4 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
24Item No.5 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
25Item No.6Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto 1.20m with precast RCC slab cover
26RCC Chamber 1.5 M X 1.5 M X 1 M - 5Nos Item No.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
27Item No.2 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
28Item No.3Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) For slab / Wall
29Item No.4 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
30Item No.5 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
31Item No.6Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto 1.20m with precast RCC slab cover
32RCC Chamber 1.5 M X 1.5 M X 1 M - 6Nos Item No.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
33Item No.2 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
34Item No.3Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) For slab / Wall
35Item No.4 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
36Item No.5 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
37Item No.6Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto 1.20m with precast RCC slab cover
38RCC Chamber 1.5 M X 1.5 M X 1 M - 7 Nos Item No.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
39Item No.2 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
40Item No.3Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) For slab / Wall
41Item No.4 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
42Item No.5 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
43Item No.6Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto 1.20m with precast RCC slab cover
44RCC Chamber 1.5 M X 1.5 M X 1 M - 8 Nos Item No.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
45Item No.2 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
46Item No.3Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) For slab / Wall
47Item No.4 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
48Item No.5 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
49Item No.6Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto 1.20m with precast RCC slab cover
50RCC Chamber 1.5 M X 1.5 M X 1 M - 9 Nos Item No.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
51Item No.2 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
52Item No.3Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) For slab / Wall
53Item No.4 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
54Item No.5 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
55Item No.6Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto 1.20m with precast RCC slab cover
56RCC Chamber 1.5 M X 1.5 M X 1 M - 10Nos Item No.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
57Item No.2 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
58Item No.3Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) For slab / Wall
59Item No.4 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
60Item No.5 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
61Item No.6Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto 1.20m with precast RCC slab cover
62RCC Chamber 1.5 M X 1.5 M X 1 M - 11Nos Item No.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
63Item No.2 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
64Item No.3Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) For slab / Wall
65Item No.4 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
66Item No.5 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
67Item No.6Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto 1.20m with precast RCC slab cover
68Metallic Tank 100000 lit Ambawade wasti A) Foundation For Metallic TankItem NO-1 Excavation for foundation /Pipe trenches in soil/HardMurum/Soft Rock/ Hard Rock including removing the excavated materials upto a distance of 50 M and lift 1.50 m stacking and spreading as directed by Engineer in charge normal dewatering shoring and strutting preparing the bed for the foundation and excluding back filling etc.A) Soil
69B) Soft Rock
70C) Hard Rock
71For Approach RoadA) Soil
72B) Soft Rock
73C) Hard Rock
74Item NO-2 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)P.C.C. M-150
75Item No-3 Providing and laying in situ Cement Concrete of trap/ granite / quartzite /gneiss metal for RCC work in foundationlike raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)M-250
76Item No-4 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete(including cost of binding wire). Tor Steel
77B)Portable Water Tank
78Item No-1 Supply and installation of prefabricated groundwater storage bolted tanks, a completepackage in knockdown, ready to assembleconstruction consisting of outer wall surfacemad out of special grade hot dip aluminum –Zink alloy, metallic factory coated steelconfirming to IS-15961-2012 minimumthickness of 0.6 mm = The inner surfaceshould be provided with liners of minimum 0.6mm thickness of reinforce polyethylene orpolypropylene or metallocene material suitablefor drinking water purpose. Top cover shall beof polyethene tape monophylament yarn orwoven polypropylene or corrugated G.I.Sheets Rate include cost of inlet, outlet,overflow Pipes up to 5 m from periphery oftank including ball valves of standard quality ,aluminum ladder, level indicater, watertightness test, transportation up to site of workexcluding GST levied by GOI & GOM in allrespect etc.complete.With RCCFoundation
79A) Above tanks can be installed on elevatedplatform. ( ESR ) the rate of tankdoes not include the cost of elevated platform.2% extra to be considered for installation oftank on elevated platform.The elevatedplatform needs to be designed as perrequirement & which will be paid separately.The elevated platform must be of steel framedstructure.
80B) For the dome type GI corrugated roofstructure with hot dip galvanized trusses withGI manhole for access for cleaning andmaintainance, 10 % extra shall be added.
81C) For heavy duty five layer polypropylenereinforced liner with mettallocene contact layerhaving a minimum thickness of 1 mm- 10 %extra shall be added
82D) Incase Rain water harvesting filters & systemto catch the rain form the GI Tank roofsmounted on the Tank roof and supplied withtank then 10 % extra shall be added.
83C) Hilly region
84C) Compound For Metalic Water Tank :ITEM NO.1- Providing and erecting chain link fencing 1.6M. height with G.I. chain link of size 50 x 50 mm8gauge thick and fixed 75 mm above Ground level vertical M.S Angle of 40 x 40 x 6 mm size embedded in C.C. block of 1:4:8 mix of size 450X 450 x 670 mm. at 1.75 M.cc with iron bar 16 mm dia. as bold fast including welding link with angle frame at 30 cm c/c nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. lat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm Angles both sides at every corner or bends embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 nm including 3 coats of oil painting etc. complete. Spec. No.: As directed by Engineer in charge.
85ITEM NO.2-Providing and fixing MS Gate 2.5 m wide for compound with 40mm dia. GI pipe approved grill work RCCM150, side piller of 25cmx40cmx2.5m height, foundation, finishing, painting etc complete.
86ITEM NO.3-Providing and fixing Wicket Gate 1.0rn wide for compound with 40inim dia. GI pipe approved grill work RCC M150, side piller of 25cmx40cmx2.5mm height, foundation, finishing, painting etc complete.
87ITEM NO.4-Online Chlorination unit -1 unit-2500000lit water chlorination capacity of single cartridge at 1ppm dosing price includes transportation upto site with installation.(As per Jalswaraj II scheme )
88Annual maintenance & operation of non electric online automatic chlorination fitted online on water supply scheme as mentioned in above item.
89Metallic Tank 200000 lit Chawan wasti A) Foundation For Metallic TankItem NO-1 Excavation for foundation /Pipe trenches in soil/HardMurum/Soft Rock/ Hard Rock including removing the excavated materials upto a distance of 50 M and lift 1.50 m stacking and spreading as directed by Engineer in charge normal dewatering shoring and strutting preparing the bed for the foundation and excluding back filling etc.A) Soil
90B) Soft Rock
91C) Hard Rock
92For Approach RoadA) Soil
93B) Soft Rock
94C) Hard Rock
95Item NO-2 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)P.C.C. M-150
96Item No-3 Providing and laying in situ Cement Concrete of trap/ granite / quartzite /gneiss metal for RCC work in foundationlike raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)M-250
97Item No-4 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete(including cost of binding wire). Tor Steel
98B)Portable Water Tank
99Item No-1 Supply and installation of prefabricated groundwater storage bolted tanks, a completepackage in knockdown, ready to assembleconstruction consisting of outer wall surfacemad out of special grade hot dip aluminum –Zink alloy, metallic factory coated steelconfirming to IS-15961-2012 minimumthickness of 0.6 mm = The inner surfaceshould be provided with liners of minimum 0.6mm thickness of reinforce polyethylene orpolypropylene or metallocene material suitablefor drinking water purpose. Top cover shall beof polyethene tape monophylament yarn orwoven polypropylene or corrugated G.I.Sheets Rate include cost of inlet, outlet,overflow Pipes up to 5 m from periphery oftank including ball valves of standard quality ,aluminum ladder, level indicater, watertightness test, transportation up to site of workexcluding GST levied by GOI & GOM in allrespect etc.complete.With RCCFoundation
100A) Above tanks can be installed on elevatedplatform. ( ESR ) the rate of tankdoes not include the cost of elevated platform.2% extra to be considered for installation oftank on elevated platform.The elevatedplatform needs to be designed as perrequirement & which will be paid separately.The elevated platform must be of steel framedstructure.
101B) For the dome type GI corrugated roofstructure with hot dip galvanized trusses withGI manhole for access for cleaning andmaintainance, 10 % extra shall be added.
102C) For heavy duty five layer polypropylenereinforced liner with mettallocene contact layerhaving a minimum thickness of 1 mm- 10 %extra shall be added
103D) Incase Rain water harvesting filters & systemto catch the rain form the GI Tank roofsmounted on the Tank roof and supplied withtank then 10 % extra shall be added.
104e) Hilly region
105C) Compound For Metalic Water Tank :ITEM NO.1- Providing and erecting chain link fencing 1.6M. height with G.I. chain link of size 50 x 50 mm8gauge thick and fixed 75 mm above Ground level vertical M.S Angle of 40 x 40 x 6 mm size embedded in C.C. block of 1:4:8 mix of size 450X 450 x 670 mm. at 1.75 M.cc with iron bar 16 mm dia. as bold fast including welding link with angle frame at 30 cm c/c nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. lat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm Angles both sides at every corner or bends embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 nm including 3 coats of oil painting etc. complete. Spec. No.: As directed by Engineer in charge.
106ITEM NO.2-Providing and fixing MS Gate 2.5 m wide for compound with 40mm dia. GI pipe approved grill work RCCM150, side piller of 25cmx40cmx2.5m height, foundation, finishing, painting etc complete.
107ITEM NO.3-Providing and fixing Wicket Gate 1.0rn wide for compound with 40inim dia. GI pipe approved grill work RCC M150, side piller of 25cmx40cmx2.5mm height, foundation, finishing, painting etc complete.
108ITEM NO.4-Online Chlorination unit -1 unit-2500000lit water chlorination capacity of single cartridge at 1ppm dosing price includes transportation upto site with installation.(As per Jalswaraj II scheme )
109Annual maintenance & operation of non electric online automatic chlorination fitted online on water supply scheme as mentioned in above item.
110RCC GSR Capacity 10000 Litre For Chawan wati Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bypass arrangement consisting of C.I. M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to all exposed surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. Anti-termite treatment shall be given for underground portion of the structure.Note:The design shall be in accordance with various relevant I.S. specification (I.S. 456/1978, I.S. 875 - 1987, I.S. 3370 -1965 or revised.Only M.S. bars grade I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used. Grade -II M.S. bars shall not be used.Entire structure shall be in M-300 only.The scope of pipe assembly work shall be upto 5 metre beyond outside face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included.The G.S.R. / Sump above 15 lakh litres capacity shall be in two compartment.The Job includes designing the structure for uplift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineerin-charge. If uplifts considered in design, then these rates shall be increased by 7.5%.G.S.R. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom.For pipe diameters upto 300 mm only CI pipes and CI specials shall be used. For pipe diameters above 300 mm, M.S. pipes and specials minimum 10 mm thick shall be used with proper anticorrosive epoxy treatment from inside and outside.Cost of pump house is not included in these rates.Above rates are applicable for Seismic Zones 2, 3 and 4.75% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R.s and sumps till satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete.Note : Conditions from Sr. No. 1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of R.C.C. GSRs and sumps.For RCC GSRs RCC GSR CapacityCost of25000 litre GRSfurther cost for 10000 litres @19.35Raft Foundation Seismic Zone5%10% For Hilly RegionTotal cost oflitre GSR
111Notes
1121) The design shall be in accordance with variousrelevant I.S. specification (I.S. 456/1978, I.S.875 - 1987, I.S. 3370 -1965 or revised.)
1132) Only M.S. bars grade I conforming to I.S. 432part-I or high yield strength deformed barsconforming to I.S. 1786 or I.S. 1139 shall beused. Grade -II M.S. bars shall not be used.
1143) Entire structure shall be in M-300 only
1154) The scope of pipe assembly work shall be upto 5metre beyond outside face of the wall, cost ofpipes valves and specials is not included in therate but labour cost for laying and jointing isincluded
1165) The G.S.R. / Sump above 15 lakh litres capacityshall be in two compartment.
1176) The Job includes designing the structure foruplift pressure and dewatering if required duringentire execution and disposal of surplusexcavated stuff within lead of 50 metres asdirected by Engineer-in-charge. If upliftsconsidered in design, then these rates shall beincreased by 7.5%
1187) G.S.R. outlets shall be with bell mouth ofapproved pattern in bottom slab and cost ofdesigning bell mouth is included in the rate.Sump well includes cost of suction pit requiredat bottom.
1198) For pipe diameters upto 300 mm only CI pipesand CI specials shall be used. For pipediameters above 300 mm, M.S. pipes andspecials minimum 10 mm thick shall be usedwith proper anticorrosive epoxy treatment frominside and outside
1209) Cost of pump house is not included in theserates.
12110) Above rates are applicable for Seismic Zones 2,3 and 4.
12211) 75% part rate shall be payable for reinforcement,concrete and plastering items of all types ofG.S.R.s and sumps till satisfactory hydraulictesting for water tightness test is given and tillthat work shall be treated as incomplete.
123Note : Conditions from Sr. No. 1 to 11 shall forma part and parcel of tender and must be includedin the draft tender papers for work of R.C.C.GSRs and sumps.
124Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Inlet 80 mm dia.GI.D./F pipes(Medium)
125Outlet80 mm dia.GI.D./F pipes(Medium)
126Washout 80 mm dia.GI.D./F pipes(Medium)
127Providing and supplying ISI standard D. I. specials & fitting with sealing rubber gasket of S.B.R,complete with cast iron follower gland and M\" S. nut holts eoated or other\"wise protected from rusting and suitable for D.l.pipes including cost of labour, materials, and transpoffation to stores, loading and unloading excluding GST levied by GOI & GOM in allrespect etc. complete as per IS-9523.80 mm to 300 mm dia
128Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeSluice valves PN-1 without bye-pass arrangement80 mm dia. Sluice valve - Outlet/Distribution
12980 mm dia. Sluice valve - Inlet/Bypass
13080 mm dia. Sluice valve - Washout
131RCC GSR Capacity 10000 Litre For Mane wasti Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bypass arrangement consisting of C.I. M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to all exposed surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. Anti-termite treatment shall be given for underground portion of the structure.Note:The design shall be in accordance with various relevant I.S. specification (I.S. 456/1978, I.S. 875 - 1987, I.S. 3370 -1965 or revised.Only M.S. bars grade I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used. Grade -II M.S. bars shall not be used.Entire structure shall be in M-300 only.The scope of pipe assembly work shall be upto 5 metre beyond outside face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included.The G.S.R. / Sump above 15 lakh litres capacity shall be in two compartment.The Job includes designing the structure for uplift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineerin-charge. If uplifts considered in design, then these rates shall be increased by 7.5%.G.S.R. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom.For pipe diameters upto 300 mm only CI pipes and CI specials shall be used. For pipe diameters above 300 mm, M.S. pipes and specials minimum 10 mm thick shall be used with proper anticorrosive epoxy treatment from inside and outside.Cost of pump house is not included in these rates.Above rates are applicable for Seismic Zones 2, 3 and 4.75% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R.s and sumps till satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete.Note : Conditions from Sr. No. 1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of R.C.C. GSRs and sumps.For RCC GSRs RCC GSR CapacityCost of25000 litre GRSfurther cost for 10000 litres @19.35Raft Foundation Seismic Zone5%10% For Hilly RegionTotal cost oflitre GSR
132Notes
1331) The design shall be in accordance with variousrelevant I.S. specification (I.S. 456/1978, I.S.875 - 1987, I.S. 3370 -1965 or revised.)
1342) Only M.S. bars grade I conforming to I.S. 432part-I or high yield strength deformed barsconforming to I.S. 1786 or I.S. 1139 shall beused. Grade -II M.S. bars shall not be used.
1353) Entire structure shall be in M-300 only
1364) The scope of pipe assembly work shall be upto 5metre beyond outside face of the wall, cost ofpipes valves and specials is not included in therate but labour cost for laying and jointing isincluded
1375) The G.S.R. / Sump above 15 lakh litres capacityshall be in two compartment.
1386) The Job includes designing the structure foruplift pressure and dewatering if required duringentire execution and disposal of surplusexcavated stuff within lead of 50 metres asdirected by Engineer-in-charge. If upliftsconsidered in design, then these rates shall beincreased by 7.5%
1397) G.S.R. outlets shall be with bell mouth ofapproved pattern in bottom slab and cost ofdesigning bell mouth is included in the rate.Sump well includes cost of suction pit requiredat bottom.
1408) For pipe diameters upto 300 mm only CI pipesand CI specials shall be used. For pipediameters above 300 mm, M.S. pipes andspecials minimum 10 mm thick shall be usedwith proper anticorrosive epoxy treatment frominside and outside
1419) Cost of pump house is not included in theserates.
14210) Above rates are applicable for Seismic Zones 2,3 and 4.
14311) 75% part rate shall be payable for reinforcement,concrete and plastering items of all types ofG.S.R.s and sumps till satisfactory hydraulictesting for water tightness test is given and tillthat work shall be treated as incomplete.
144Note : Conditions from Sr. No. 1 to 11 shall forma part and parcel of tender and must be includedin the draft tender papers for work of R.C.C.GSRs and sumps.
145Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Inlet 80 mm dia.GI.D./F pipes(Medium)
146Outlet80 mm dia.GI.D./F pipes(Medium)
147Washout 80 mm dia.GI.D./F pipes(Medium)
148Providing and supplying ISI standard D. I. specials & fitting with sealing rubber gasket of S.B.R,complete with cast iron follower gland and M\" S. nut holts eoated or other\"wise protected from rusting and suitable for D.l.pipes including cost of labour, materials, and transpoffation to stores, loading and unloading excluding GST levied by GOI & GOM in allrespect etc. complete as per IS-9523.80 mm to 300 mm dia
149Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeSluice valves PN-1 without bye-pass arrangement80 mm dia. Sluice valve - Outlet/Distribution
15080 mm dia. Sluice valve - Inlet/Bypass
15180 mm dia. Sluice valve - Washout
152RCC GSR Capacity 10000 Litre For Kokare wasti Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bypass arrangement consisting of C.I. M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to all exposed surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. Anti-termite treatment shall be given for underground portion of the structure.Note:The design shall be in accordance with various relevant I.S. specification (I.S. 456/1978, I.S. 875 - 1987, I.S. 3370 -1965 or revised.Only M.S. bars grade I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used. Grade -II M.S. bars shall not be used.Entire structure shall be in M-300 only.The scope of pipe assembly work shall be upto 5 metre beyond outside face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included.The G.S.R. / Sump above 15 lakh litres capacity shall be in two compartment.The Job includes designing the structure for uplift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineerin-charge. If uplifts considered in design, then these rates shall be increased by 7.5%.G.S.R. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom.For pipe diameters upto 300 mm only CI pipes and CI specials shall be used. For pipe diameters above 300 mm, M.S. pipes and specials minimum 10 mm thick shall be used with proper anticorrosive epoxy treatment from inside and outside.Cost of pump house is not included in these rates.Above rates are applicable for Seismic Zones 2, 3 and 4.75% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R.s and sumps till satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete.Note : Conditions from Sr. No. 1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of R.C.C. GSRs and sumps.For RCC GSRs RCC GSR CapacityCost of25000 litre GRSfurther cost for 10000 litres @19.35Raft Foundation Seismic Zone5%10% For Hilly RegionTotal cost oflitre GSR
153Notes
1541) The design shall be in accordance with variousrelevant I.S. specification (I.S. 456/1978, I.S.875 - 1987, I.S. 3370 -1965 or revised.)
1552) Only M.S. bars grade I conforming to I.S. 432part-I or high yield strength deformed barsconforming to I.S. 1786 or I.S. 1139 shall beused. Grade -II M.S. bars shall not be used.
1563) Entire structure shall be in M-300 only
1574) The scope of pipe assembly work shall be upto 5metre beyond outside face of the wall, cost ofpipes valves and specials is not included in therate but labour cost for laying and jointing isincluded
1585) The G.S.R. / Sump above 15 lakh litres capacityshall be in two compartment.
1596) The Job includes designing the structure foruplift pressure and dewatering if required duringentire execution and disposal of surplusexcavated stuff within lead of 50 metres asdirected by Engineer-in-charge. If upliftsconsidered in design, then these rates shall beincreased by 7.5%
1607) G.S.R. outlets shall be with bell mouth ofapproved pattern in bottom slab and cost ofdesigning bell mouth is included in the rate.Sump well includes cost of suction pit requiredat bottom.
1618) For pipe diameters upto 300 mm only CI pipesand CI specials shall be used. For pipediameters above 300 mm, M.S. pipes andspecials minimum 10 mm thick shall be usedwith proper anticorrosive epoxy treatment frominside and outside
1629) Cost of pump house is not included in theserates.
16310) Above rates are applicable for Seismic Zones 2,3 and 4.
16411) 75% part rate shall be payable for reinforcement,concrete and plastering items of all types ofG.S.R.s and sumps till satisfactory hydraulictesting for water tightness test is given and tillthat work shall be treated as incomplete.
165Note : Conditions from Sr. No. 1 to 11 shall forma part and parcel of tender and must be includedin the draft tender papers for work of R.C.C.GSRs and sumps.
166Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Inlet 80 mm dia.GI.D./F pipes(Medium)
167Outlet80 mm dia.GI.D./F pipes(Medium)
168Washout 80 mm dia.GI.D./F pipes(Medium)
169Providing and supplying ISI standard D. I. specials & fitting with sealing rubber gasket of S.B.R,complete with cast iron follower gland and M\" S. nut holts eoated or other\"wise protected from rusting and suitable for D.l.pipes including cost of labour, materials, and transpoffation to stores, loading and unloading excluding GST levied by GOI & GOM in allrespect etc. complete as per IS-9523.80 mm to 300 mm dia
170Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeSluice valves PN-1 without bye-pass arrangement80 mm dia. Sluice valve - Outlet/Distribution
17180 mm dia. Sluice valve - Inlet/Bypass
17280 mm dia. Sluice valve - Washout
173RCC GSR Capacity 10000 Litre For Pisadi Maraje wasti Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bypass arrangement consisting of C.I. M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to all exposed surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. Anti-termite treatment shall be given for underground portion of the structure.Note:The design shall be in accordance with various relevant I.S. specification (I.S. 456/1978, I.S. 875 - 1987, I.S. 3370 -1965 or revised.Only M.S. bars grade I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used. Grade -II M.S. bars shall not be used.Entire structure shall be in M-300 only.The scope of pipe assembly work shall be upto 5 metre beyond outside face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included.The G.S.R. / Sump above 15 lakh litres capacity shall be in two compartment.The Job includes designing the structure for uplift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineerin-charge. If uplifts considered in design, then these rates shall be increased by 7.5%.G.S.R. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom.For pipe diameters upto 300 mm only CI pipes and CI specials shall be used. For pipe diameters above 300 mm, M.S. pipes and specials minimum 10 mm thick shall be used with proper anticorrosive epoxy treatment from inside and outside.Cost of pump house is not included in these rates.Above rates are applicable for Seismic Zones 2, 3 and 4.75% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R.s and sumps till satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete.Note : Conditions from Sr. No. 1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of R.C.C. GSRs and sumps.For RCC GSRs RCC GSR CapacityCost of25000 litre GRSfurther cost for 10000 litres @19.35Raft Foundation Seismic Zone5%10% For Hilly RegionTotal cost oflitre GSR
174Notes
1751) The design shall be in accordance with variousrelevant I.S. specification (I.S. 456/1978, I.S.875 - 1987, I.S. 3370 -1965 or revised.)
1762) Only M.S. bars grade I conforming to I.S. 432part-I or high yield strength deformed barsconforming to I.S. 1786 or I.S. 1139 shall beused. Grade -II M.S. bars shall not be used.
1773) Entire structure shall be in M-300 only
1784) The scope of pipe assembly work shall be upto 5metre beyond outside face of the wall, cost ofpipes valves and specials is not included in therate but labour cost for laying and jointing isincluded
1795) The G.S.R. / Sump above 15 lakh litres capacityshall be in two compartment.
1806) The Job includes designing the structure foruplift pressure and dewatering if required duringentire execution and disposal of surplusexcavated stuff within lead of 50 metres asdirected by Engineer-in-charge. If upliftsconsidered in design, then these rates shall beincreased by 7.5%
1817) G.S.R. outlets shall be with bell mouth ofapproved pattern in bottom slab and cost ofdesigning bell mouth is included in the rate.Sump well includes cost of suction pit requiredat bottom.
1828) For pipe diameters upto 300 mm only CI pipesand CI specials shall be used. For pipediameters above 300 mm, M.S. pipes andspecials minimum 10 mm thick shall be usedwith proper anticorrosive epoxy treatment frominside and outside
1839) Cost of pump house is not included in theserates.
18410) Above rates are applicable for Seismic Zones 2,3 and 4.
18511) 75% part rate shall be payable for reinforcement,concrete and plastering items of all types ofG.S.R.s and sumps till satisfactory hydraulictesting for water tightness test is given and tillthat work shall be treated as incomplete.
186Note : Conditions from Sr. No. 1 to 11 shall forma part and parcel of tender and must be includedin the draft tender papers for work of R.C.C.GSRs and sumps.
187Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Inlet 80 mm dia.GI.D./F pipes(Medium)
188Outlet80 mm dia.GI.D./F pipes(Medium)
189Washout 80 mm dia.GI.D./F pipes(Medium)
190Providing and supplying ISI standard D. I. specials & fitting with sealing rubber gasket of S.B.R,complete with cast iron follower gland and M\" S. nut holts eoated or other\"wise protected from rusting and suitable for D.l.pipes including cost of labour, materials, and transpoffation to stores, loading and unloading excluding GST levied by GOI & GOM in allrespect etc. complete as per IS-9523.80 mm to 300 mm dia
191Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeSluice valves PN-1 without bye-pass arrangement80 mm dia. Sluice valve - Outlet/Distribution
19280 mm dia. Sluice valve - Inlet/Bypass
19380 mm dia. Sluice valve - Washout
194RCC GSR Capacity 10000 Litre For Katre Wadi Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bypass arrangement consisting of C.I. M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to all exposed surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. Anti-termite treatment shall be given for underground portion of the structure.Note:The design shall be in accordance with various relevant I.S. specification (I.S. 456/1978, I.S. 875 - 1987, I.S. 3370 -1965 or revised.Only M.S. bars grade I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used. Grade -II M.S. bars shall not be used.Entire structure shall be in M-300 only.The scope of pipe assembly work shall be upto 5 metre beyond outside face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included.The G.S.R. / Sump above 15 lakh litres capacity shall be in two compartment.The Job includes designing the structure for uplift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineerin-charge. If uplifts considered in design, then these rates shall be increased by 7.5%.G.S.R. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom.For pipe diameters upto 300 mm only CI pipes and CI specials shall be used. For pipe diameters above 300 mm, M.S. pipes and specials minimum 10 mm thick shall be used with proper anticorrosive epoxy treatment from inside and outside.Cost of pump house is not included in these rates.Above rates are applicable for Seismic Zones 2, 3 and 4.75% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R.s and sumps till satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete.Note : Conditions from Sr. No. 1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of R.C.C. GSRs and sumps.For RCC GSRs RCC GSR CapacityCost of25000 litre GRSfurther cost for 10000 litres @19.35Raft Foundation Seismic Zone5%10% For Hilly RegionTotal cost oflitre GSR
195Notes
1961) The design shall be in accordance with variousrelevant I.S. specification (I.S. 456/1978, I.S.875 - 1987, I.S. 3370 -1965 or revised.)
1972) Only M.S. bars grade I conforming to I.S. 432part-I or high yield strength deformed barsconforming to I.S. 1786 or I.S. 1139 shall beused. Grade -II M.S. bars shall not be used.
1983) Entire structure shall be in M-300 only
1994) The scope of pipe assembly work shall be upto 5metre beyond outside face of the wall, cost ofpipes valves and specials is not included in therate but labour cost for laying and jointing isincluded
2005) The G.S.R. / Sump above 15 lakh litres capacityshall be in two compartment.
2016) The Job includes designing the structure foruplift pressure and dewatering if required duringentire execution and disposal of surplusexcavated stuff within lead of 50 metres asdirected by Engineer-in-charge. If upliftsconsidered in design, then these rates shall beincreased by 7.5%
2027) G.S.R. outlets shall be with bell mouth ofapproved pattern in bottom slab and cost ofdesigning bell mouth is included in the rate.Sump well includes cost of suction pit requiredat bottom.
2038) For pipe diameters upto 300 mm only CI pipesand CI specials shall be used. For pipediameters above 300 mm, M.S. pipes andspecials minimum 10 mm thick shall be usedwith proper anticorrosive epoxy treatment frominside and outside
2049) Cost of pump house is not included in theserates.
20510) Above rates are applicable for Seismic Zones 2,3 and 4.
20611) 75% part rate shall be payable for reinforcement,concrete and plastering items of all types ofG.S.R.s and sumps till satisfactory hydraulictesting for water tightness test is given and tillthat work shall be treated as incomplete.
207Note : Conditions from Sr. No. 1 to 11 shall forma part and parcel of tender and must be includedin the draft tender papers for work of R.C.C.GSRs and sumps.
208Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Inlet 80 mm dia.GI.D./F pipes(Medium)
209Outlet80 mm dia.GI.D./F pipes(Medium)
210Washout 80 mm dia.GI.D./F pipes(Medium)
211Providing and supplying ISI standard D. I. specials & fitting with sealing rubber gasket of S.B.R,complete with cast iron follower gland and M\" S. nut holts eoated or other\"wise protected from rusting and suitable for D.l.pipes including cost of labour, materials, and transpoffation to stores, loading and unloading excluding GST levied by GOI & GOM in allrespect etc. complete as per IS-9523.80 mm to 300 mm dia
212Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeSluice valves PN-1 without bye-pass arrangement80 mm dia. Sluice valve - Outlet/Distribution
21380 mm dia. Sluice valve - Inlet/Bypass
21480 mm dia. Sluice valve - Washout
215RCC GSR Capacity 5000 Litre For Pisadi Pandhare Wasti Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bypass arrangement consisting of C.I. M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to all exposed surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. Anti-termite treatment shall be given for underground portion of the structure.Note:The design shall be in accordance with various relevant I.S. specification (I.S. 456/1978, I.S. 875 - 1987, I.S. 3370 -1965 or revised.Only M.S. bars grade I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used. Grade -II M.S. bars shall not be used.Entire structure shall be in M-300 only.The scope of pipe assembly work shall be upto 5 metre beyond outside face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included.The G.S.R. / Sump above 15 lakh litres capacity shall be in two compartment.The Job includes designing the structure for uplift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineerin-charge. If uplifts considered in design, then these rates shall be increased by 7.5%.G.S.R. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom.For pipe diameters upto 300 mm only CI pipes and CI specials shall be used. For pipe diameters above 300 mm, M.S. pipes and specials minimum 10 mm thick shall be used with proper anticorrosive epoxy treatment from inside and outside.Cost of pump house is not included in these rates.Above rates are applicable for Seismic Zones 2, 3 and 4.75% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R.s and sumps till satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete.Note : Conditions from Sr. No. 1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of R.C.C. GSRs and sumps.For RCC GSRs RCC GSR CapacityCost of25000 litre GRSfurther cost for 5000 litres @19.35Raft Foundation Seismic Zone5%10% For Hilly RegionTotal cost oflitre GSR
216Notes
2171) The design shall be in accordance with variousrelevant I.S. specification (I.S. 456/1978, I.S.875 - 1987, I.S. 3370 -1965 or revised.)
2182) Only M.S. bars grade I conforming to I.S. 432part-I or high yield strength deformed barsconforming to I.S. 1786 or I.S. 1139 shall beused. Grade -II M.S. bars shall not be used.
2193) Entire structure shall be in M-300 only
2204) The scope of pipe assembly work shall be upto 5metre beyond outside face of the wall, cost ofpipes valves and specials is not included in therate but labour cost for laying and jointing isincluded
2215) The G.S.R. / Sump above 15 lakh litres capacityshall be in two compartment.
2226) The Job includes designing the structure foruplift pressure and dewatering if required duringentire execution and disposal of surplusexcavated stuff within lead of 50 metres asdirected by Engineer-in-charge. If upliftsconsidered in design, then these rates shall beincreased by 7.5%
2237) G.S.R. outlets shall be with bell mouth ofapproved pattern in bottom slab and cost ofdesigning bell mouth is included in the rate.Sump well includes cost of suction pit requiredat bottom.
2248) For pipe diameters upto 300 mm only CI pipesand CI specials shall be used. For pipediameters above 300 mm, M.S. pipes andspecials minimum 10 mm thick shall be usedwith proper anticorrosive epoxy treatment frominside and outside
2259) Cost of pump house is not included in theserates.
22610) Above rates are applicable for Seismic Zones 2,3 and 4.
22711) 75% part rate shall be payable for reinforcement,concrete and plastering items of all types ofG.S.R.s and sumps till satisfactory hydraulictesting for water tightness test is given and tillthat work shall be treated as incomplete.
228Note : Conditions from Sr. No. 1 to 11 shall forma part and parcel of tender and must be includedin the draft tender papers for work of R.C.C.GSRs and sumps.
229Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Inlet 80 mm dia.GI.D./F pipes(Medium)
230Outlet80 mm dia.GI.D./F pipes(Medium)
231Washout 80 mm dia.GI.D./F pipes(Medium)
232Providing and supplying ISI standard D. I. specials & fitting with sealing rubber gasket of S.B.R,complete with cast iron follower gland and M\" S. nut holts eoated or other\"wise protected from rusting and suitable for D.l.pipes including cost of labour, materials, and transpoffation to stores, loading and unloading excluding GST levied by GOI & GOM in allrespect etc. complete as per IS-9523.80 mm to 300 mm dia
233Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeSluice valves PN-1 without bye-pass arrangement80 mm dia. Sluice valve - Outlet/Distribution
23480 mm dia. Sluice valve - Inlet/Bypass
23580 mm dia. Sluice valve - Washout
236Gravity Main L = 2000 M 40 mm Dia From Spring-1 & 2 to Chawan wasti Dismantling dead pipeline of M.S./ R.C.C./ C.I./ P.S.C. and G.I./ A.C./ P.V.C./ S.W./ H.D.P.E. pipe including cost of necessary excavation and refilling of trenches, breaking the joints, lifting the pipes and stacking to the place as directed by Engineer-in-charge with all leads and lifts including cleaning the surface, etc. complete40mm
237Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe40mm
238Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeWithout by pass arrangement - PN -1 Scour Valve50 ø
239Providingandsupplying Air Valvesas per IS-10845and MJP’s standard specificationsdoubleorificetypecombinedwithscrewdownisolatingvalve,small orificeelasticballrestingonagunmetalorificenipple,largeorificevulcaniteball seatingon mouldedseatring,inletfaceanddrilled,includingall taxes(Centraland local), insurance, third party inspection charges, loading, unloding, transportatoin upto departmental stores / site, etc. complete. Air Valve Single Ball Flanged Type - PN -115 ø
240Labour SectionExcavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
241Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
242Filling in plinth and floors murum bedding intrenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)from excavated stuff
243Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe40mm
244Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe40mm
245Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )50 ø
246Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.)upto 150mm
247ProvidingandconstructingB.B.masonryvalvechamberwith15cmthick1:2:4 proportionPCCbedding,excludingexcavation,B.B. masonryin C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge.As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover.
248Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Forencasingand reconstruction of road
249Refillingthetrenches withavailableexcavated stuffwithsoftmaterialfirstover pipelineandthenhardmaterialin15cmlayerswithallleadsandliftsincluding consolidation, surcharging,etc. complete.Net Volume of Refilling
250Gravity Main L = 1400 M 40 mm Dia From Spring-3 to Mane wasti Dismantling dead pipeline of M.S./ R.C.C./ C.I./ P.S.C. and G.I./ A.C./ P.V.C./ S.W./ H.D.P.E. pipe including cost of necessary excavation and refilling of trenches, breaking the joints, lifting the pipes and stacking to the place as directed by Engineer-in-charge with all leads and lifts including cleaning the surface, etc. complete40mm
251Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe40mm
252Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeWithout by pass arrangement - PN -1 Scour Valve50 ø
253Providingandsupplying Air Valvesas per IS-10845and MJP’s standard specificationsdoubleorificetypecombinedwithscrewdownisolatingvalve,small orificeelasticballrestingonagunmetalorificenipple,largeorificevulcaniteball seatingon mouldedseatring,inletfaceanddrilled,includingall taxes(Centraland local), insurance, third party inspection charges, loading, unloding, transportatoin upto departmental stores / site, etc. complete. Air Valve Single Ball Flanged Type - PN -115 ø
254Labour SectionExcavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
255Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
256Filling in plinth and floors murum bedding intrenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)from excavated stuff
257Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe40mm
258Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe40mm
259Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )50 ø
260Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.)upto 150mm
261ProvidingandconstructingB.B.masonryvalvechamberwith15cmthick1:2:4 proportionPCCbedding,excludingexcavation,B.B. masonryin C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge.As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover.
262Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Forencasingand reconstruction of road
263Refillingthetrenches withavailableexcavated stuffwithsoftmaterialfirstover pipelineandthenhardmaterialin15cmlayerswithallleadsandliftsincluding consolidation, surcharging,etc. complete.Net Volume of Refilling
264Gravity Main L = 1400 M 40 mm Dia From Spring-4 & 10 to Pisade wasti Dismantling dead pipeline of M.S./ R.C.C./ C.I./ P.S.C. and G.I./ A.C./ P.V.C./ S.W./ H.D.P.E. pipe including cost of necessary excavation and refilling of trenches, breaking the joints, lifting the pipes and stacking to the place as directed by Engineer-in-charge with all leads and lifts including cleaning the surface, etc. complete40mm
265Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe40mm
266Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeWithout by pass arrangement - PN -1 Scour Valve50 ø
267Providingandsupplying Air Valvesas per IS-10845and MJP’s standard specificationsdoubleorificetypecombinedwithscrewdownisolatingvalve,small orificeelasticballrestingonagunmetalorificenipple,largeorificevulcaniteball seatingon mouldedseatring,inletfaceanddrilled,includingall taxes(Centraland local), insurance, third party inspection charges, loading, unloding, transportatoin upto departmental stores / site, etc. complete. Air Valve Single Ball Flanged Type - PN -115 ø
268Labour SectionExcavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
269Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
270Filling in plinth and floors murum bedding intrenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)from excavated stuff
271Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe40mm
272Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe40mm
273Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )50 ø
274Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.)upto 150mm
275ProvidingandconstructingB.B.masonryvalvechamberwith15cmthick1:2:4 proportionPCCbedding,excludingexcavation,B.B. masonryin C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge.As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover.
276Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Forencasingand reconstruction of road
277Refillingthetrenches withavailableexcavated stuffwithsoftmaterialfirstover pipelineandthenhardmaterialin15cmlayerswithallleadsandliftsincluding consolidation, surcharging,etc. complete.Net Volume of Refilling
278Gravity Main L = 1400 M 40 mm Dia From Spring-4 & 10 to Pisade wasti Dismantling dead pipeline of M.S./ R.C.C./ C.I./ P.S.C. and G.I./ A.C./ P.V.C./ S.W./ H.D.P.E. pipe including cost of necessary excavation and refilling of trenches, breaking the joints, lifting the pipes and stacking to the place as directed by Engineer-in-charge with all leads and lifts including cleaning the surface, etc. complete40mm
279Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe40mm
280Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeWithout by pass arrangement - PN -1 Scour Valve50 ø
281Providingandsupplying Air Valvesas per IS-10845and MJP’s standard specificationsdoubleorificetypecombinedwithscrewdownisolatingvalve,small orificeelasticballrestingonagunmetalorificenipple,largeorificevulcaniteball seatingon mouldedseatring,inletfaceanddrilled,includingall taxes(Centraland local), insurance, third party inspection charges, loading, unloding, transportatoin upto departmental stores / site, etc. complete. Air Valve Single Ball Flanged Type - PN -115 ø
282Labour SectionExcavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
283Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
284Filling in plinth and floors murum bedding intrenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)from excavated stuff
285Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe40mm
286Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe40mm
287Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )50 ø
288Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.)upto 150mm
289ProvidingandconstructingB.B.masonryvalvechamberwith15cmthick1:2:4 proportionPCCbedding,excludingexcavation,B.B. masonryin C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge.As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover.
290Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Forencasingand reconstruction of road
291Refillingthetrenches withavailableexcavated stuffwithsoftmaterialfirstover pipelineandthenhardmaterialin15cmlayerswithallleadsandliftsincluding consolidation, surcharging,etc. complete.Net Volume of Refilling
292Gravity Main L = 400 M 40 mm Dia From Spring-6 ,7 & 11 to Pisade Pandhare wasti Dismantling dead pipeline of M.S./ R.C.C./ C.I./ P.S.C. and G.I./ A.C./ P.V.C./ S.W./ H.D.P.E. pipe including cost of necessary excavation and refilling of trenches, breaking the joints, lifting the pipes and stacking to the place as directed by Engineer-in-charge with all leads and lifts including cleaning the surface, etc. complete40mm
293Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe40mm
294Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeWithout by pass arrangement - PN -1 Scour Valve50 ø
295Providingandsupplying Air Valvesas per IS-10845and MJP’s standard specificationsdoubleorificetypecombinedwithscrewdownisolatingvalve,small orificeelasticballrestingonagunmetalorificenipple,largeorificevulcaniteball seatingon mouldedseatring,inletfaceanddrilled,includingall taxes(Centraland local), insurance, third party inspection charges, loading, unloding, transportatoin upto departmental stores / site, etc. complete. Air Valve Single Ball Flanged Type - PN -115 ø
296Labour SectionExcavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
297Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
298Filling in plinth and floors murum bedding intrenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)from excavated stuff
299Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe40mm
300Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe40mm
301Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )50 ø
302Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.)upto 150mm
303ProvidingandconstructingB.B.masonryvalvechamberwith15cmthick1:2:4 proportionPCCbedding,excludingexcavation,B.B. masonryin C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge.As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover.
304Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Forencasingand reconstruction of road
305Refillingthetrenches withavailableexcavated stuffwithsoftmaterialfirstover pipelineandthenhardmaterialin15cmlayerswithallleadsandliftsincluding consolidation, surcharging,etc. complete.Net Volume of Refilling
306Gravity Main L = 500 M 40 mm Dia From Spring-8 & 9 to Katrewadi wasti Dismantling dead pipeline of M.S./ R.C.C./ C.I./ P.S.C. and G.I./ A.C./ P.V.C./ S.W./ H.D.P.E. pipe including cost of necessary excavation and refilling of trenches, breaking the joints, lifting the pipes and stacking to the place as directed by Engineer-in-charge with all leads and lifts including cleaning the surface, etc. complete40mm
307Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe40mm
308Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeWithout by pass arrangement - PN -1 Scour Valve50 ø
309Providingandsupplying Air Valvesas per IS-10845and MJP’s standard specificationsdoubleorificetypecombinedwithscrewdownisolatingvalve,small orificeelasticballrestingonagunmetalorificenipple,largeorificevulcaniteball seatingon mouldedseatring,inletfaceanddrilled,includingall taxes(Centraland local), insurance, third party inspection charges, loading, unloding, transportatoin upto departmental stores / site, etc. complete. Air Valve Single Ball Flanged Type - PN -115 ø
310Labour SectionExcavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
311Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
312Filling in plinth and floors murum bedding intrenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)from excavated stuff
313Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe40mm
314Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe40mm
315Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )50 ø
316Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.)upto 150mm
317ProvidingandconstructingB.B.masonryvalvechamberwith15cmthick1:2:4 proportionPCCbedding,excludingexcavation,B.B. masonryin C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge.As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover.
318Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Forencasingand reconstruction of road
319Refillingthetrenches withavailableexcavated stuffwithsoftmaterialfirstover pipelineandthenhardmaterialin15cmlayerswithallleadsandliftsincluding consolidation, surcharging,etc. complete.Net Volume of Refilling
320Distribution System Total Length = 893 m 75 ø mm to 110 ømm HDPE PN6 MATERIAL Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GSTlevied by GI & GOM in all respect etc. complete.63 ø 6kg/cm2
32175 ø6kg/cm2
322Providing & Supply of Electro Fusion Fittingsin accordance with BS EN12201: Part-3 suitablefor drinking water with in black/ blue colourmanufactured from compounded PE80/ PE100virgin polymer and compatible with PE80/PE100pipes, in pressure rating SDR11 with min PN12.5rated for water application and shall be inclusive ofall cost such as testing, inspection charges,transportation up to store, transit insurance,loading, unloading, stacking excluding GST leviedby GOI & GOM in all respect, etc. complete.Couplers 63
323Couplers 75
324Equal Tee 63
325Equal Tee 75
326LNPE 63 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint
327LNPE 75 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint
328Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe50 ø
32965 ø
330Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. complete.Without by pass arrangement - PN-1.50 ø
33165 ø
332LABOURExcavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5
333Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5
334Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-3/259)Lift 0 to 1.5
335Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in_x0002_charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259)Lift 0 to 1.5
336Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259)Lift 0 to 1.5
337Filling in plinth and floors murum bedding intrenches with approved murum fromexcavated materials from foundation in 15cm to 20 cm layers including watering andcompaction, etc. complete. (Bd-A-10/263)from excavated stuff
338Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including allspecials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part IIWorking Pressure 6 kg/cm²63 ø6kg/cm2
33975 ø6kg/cm2
340Hydraulic testing of H. D. P. E./ M. D. P. E.pipe line to specified pressure including cost ofall materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position...63 ø6kg/cm2
34175 ø6kg/cm2
342Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe50 ø
34365 ø
344Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe50 ø
34565 ø
346Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )50 ø
34765 ø
348Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete100 mm x 225 mm (20 kg)
349Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)For Road Reconstruction PCC M150
350Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.Net volume of refilling
351Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line. (The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores.)50 mm
35265 mm
353INFORMATORY SIGN BOARDS, TRIAL RUN AND CHLORINATION Commisioning running and maintaining the scheme to quantities, rate capacity, including manning necessory personnel such as operator, valveman, etc, as pr requirements of the scheme and who should also administer chemical dose for a period of one month for individual scheme together with training of personnel spared by MJP/ Local Body and handling over the scheme to Local Body after completion of the above period as directed by Engineer - in charge.For single village
354Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Chargewith two coats of greystove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground levelas per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.
355FUNCTIONAL HOUSEHOLD TAP CONNECTION (FHTC) Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitable material and sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in all types of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineer inA) Household Connection without water meter (Comression Saddle+ISI Mark Ferrul) for HDPE & PVC pipeFor MDPE/UPVC Pipe Service Connection on Disribution main.(Without Road Crossing)For 15 mm Service connection
356For MDPE/UPVC Pipe Service Connection on Disribution main.(With Road Crossing)For 15 mm Service connection

AI Tender Summary

OUR REF NO 49879315
AUTHORITY Government Departments
TENDER VALUE 1.21 Crore
LAST DATE 18-07-2025
Authority
Authority Name Rural Development Department
Work Description Construction/Retrofitting Of Pws Scheme At Kargaon, Tal. Jaoli, Dist- Satara
Basic Detail
Tender No ZPS/RWS/JJM/2025 - 2nd call
Bidding Type Tender
Location
City jaoli
State Maharashtra
Key Dates
Publish Date 09 Jul 2025
Submission Date 18 Jul 2025
Open Date 19 Jul 2025
Finance
Tender Value 1.21 Crore
Tender Fee 5000
EMD 1.21 Lakhs
Exemption Not Available
Document List
B1Kargaon.pdf
3ce1b480-b270-490f-8ad4-b81d7f8a1098.html
BOQ_2070009.xls
NITKargaon.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 18, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 18, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 19, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

B1Kargaon.pdf

html

3ce1b480-b270-490f-8ad4-b81d7f8a1098.html

xls

BOQ_2070009.xls

pdf

NITKargaon.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders