Tender For Repair, Replacement, Maintenance Of Ht External Services, Repair Of Ht 2/4/6 Pole Structure, God, Sub Station Panels, Cables, Ht Air Break Switch And Repair Maintenance Servicing Of Ht Switch Gear And Rmu Installed At Naval Station Karanja
Tender Overview
Project Description
Repair, Replacement, Maintenance Of Ht External Services, Repair Of Ht 2/4/6 Pole Structure, God, Sub Station Panels, Cables, Ht Air Break Switch And Repair Maintenance Servicing Of Ht Switch Gear And Rmu Installed At Naval Station Karanja
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches for not exc 1.5 metre wide and not exc 1.5 metre depth and getting out in soft/loose soil including taking out faulty cable/cable, cable covers and GI pipe, complete all as specified and directed by Engr-in-Charge. |
| 2 | Removing excavated materials not exc 50m and depositingwhere directed at a level not exc 1.5m above the Starting point, complete all as specified and directed by Engr-in-Charge. |
| 3 | Returning filling in including spreading levelling watering and well ramming in layers not exc 25cm, complete all as specified and directed by Engr-in-Charge. |
| 4 | Supply and lay sand cushioning to under ground HT cable complete all as specified in SSR Part-I and as directed by Engineer-in-charge. |
| 5 | Supply and Laying reinforced precast concrete cable cover laid width wise factory made, class EHV type 1 with peak size 450 mm x 230 mm x 50 mm, complete all as specified and directed by Engr-in-Charge. |
| 6 | Laying only precast concrete cover of size 450mm x 230mm x 50 mm obtained from item No 1.00 here-in-before, complete all as specified and directed by Engr-in-Charge. |
| 7 | Supply, laying in repairs, in trenches /ducts/fixing on pole/STR with suitable size of GI clamp made out of GI strip 32 mm x 6 mm, XLPE HT insulated, screened, earthed, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) ofsize 3 x 120sqmm with aluminium conductor suitable for 22 KV grade as per relevant IS including latest amendment for IS (ISI marked cable) testing, commissioning along with HT cable route indicator complete all as specified and directed by Engr-in-Charge.Notes :- (a) Earth work, EHV cable cover, sand cushioning & GI pipe will be measured and paid separately. (b) High voltage test to be conducted at site with suitable voltage before and after laying of HT cable and reading shall be recorded jointly and test report to be submitted in triplicate to the Engineer-in-Charge. The cost of the same shall be deemed to be included in the unit rate quoted above. |
| 8 | Taking out carefully cable covers &HT cable from excavated trench/duct/pole of size 120 sqmm 3 core, complete all as specified and directed by Engr-in-Charge. |
| 9 | Relaying of HT cable of size 120 sqmm 3 core in trench/duct/pipe obtained from item No 8.00 here-in-before, complete all as specified and directed by Engr-in-Charge. |
| 10 | Material and Labour for drawing 3 phase with aluminium conductor, steel reinforced DOG, complete all as specified and directed by Engr-in-Charge. |
| 11 | Material and Labour for notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 22 KV of size 25 x 20 cm, complete all as specified and directed by Engr-in-Charge. |
| 12 | Material and Labour for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat, one under coat and two finishing coats of aluminium paint, complete all as specified and directed by Engr-in-Charge. |
| 13 | Dismantling of unserviceable cross arms of MS Chanel/angle sections etc, complete all as specified and directed by Engr-in-Charge. |
| 14 | Periodical check/preventive maintenance of HT 22 KV out door ring main units ofconfiguration of 10 way (4 LBS+ 6 VCB) once in a year as per recommendation of manufacturer as under complete all as specified and as directed by Engr-in-charge :-(a) Complete servicing(b) Functional checks(c) Protection checks(d) 22kV outdoor type motorized RMU outdoor enclosure body cleaning(e) Clean and check tightness of cable termination & amp; bushing in cable compartment(f) Checking of sealing of gland plate area(g) Check mechanical interlocks load break switch and earth switch(h) Relay testing and calibration in coordination with upstream and down stream relays(j) Check close & amp; trip coil condition(k) Functional check of trip circuit(l) Clean and check tightness of control wiring(m) Check door alignment(n) Testing/calibration of current transformer (if required)(o) Checking of SF6 gas level and fill if gas pressure is low(p) Clean and check bus PT metering panel(q) Clean and check battery charger(r) To check PT/ Aux. PT fuse and replace if required(s) Clean and check bus PT(t) Clean and check auxiliary PTNote:- The work to be carried out by the OEM and submit calibration certificate of relays and current transformer by authorised agency. |
| 15 | -Ditto- all as per item No 14.00 here-in-before but HT 22 KV out door ring main units of configuration of 9 way (5 LBS+ 5 VCB) |
| 16 | -Ditto- all as per item No 14.00 here-in-before but HT 22 KV out door ring main units ofconfiguration of 9 way (4 LBS+ 5 VCB) |
| 17 | -Ditto- all as per item No 14.00 here-in-before but HT 22 KV out door ring main units ofconfiguration of 7 way (2 LBS+ 5 VCB) |
| 18 | -Ditto- all as per item No 14.00 here-in-before but HT 22 KV out door ring main units ofconfiguration of 7 way (3 LBS+ 4VCB) |
| 19 | -Ditto- all as per item No 14.00 here-in-before but HT 22 KV out door ring main units ofconfiguration of 7 way (4 LBS+ 3 VCB) |
| 20 | -Ditto- all as per item No 14.00 here-in-before but HT 22 KV out door ring main units ofconfiguration of 6 way (3 LBS+ 3 VCB) |
| 21 | -Ditto- all as per item No 14.00 here-in-before but HT 22 KV out door ring main units ofconfiguration of 6 way (4 LBS+ 2 VCB) |
| 22 | -Ditto- all as per item No 14.00 here-in-before but HT 22 KV out door ring main units ofconfiguration of 5 way (3 LBS+ 2 VCB) |
| 23 | -Ditto- all as per item No 14.00 here-in-before but HT 22 KV out door ring main units ofconfiguration of 3 way (2 LBS+ 1 VCB) |
| 24 | Supply and fix for following spare parts for out door type ring main unit of above configuration covered in item Nos 14 to 23 here-in-before, complete all as specified and as directed by Engr-in-charge. |
| 25 | Ring LT/CT 30/1A, 2.5VA CL-5P10 |
| 26 | LT CT Resin cast iron type ratio - 100/1A, 2.5VA CL-1.0 |
| 27 | PT 22KV/Root 3/110V/ Root 3, 50 VA-CL-1/EE090562, 3 Phase |
| 28 | Auxiliary transformer 22KV/Rt3/230V,AC, 500VA |
| 29 | HT Fuse 22 KV/3.15A/EE090344 |
| 30 | CS FPI -earth fault indicator, E/F-10-100A, with 1NO+1NC, sensor-100-120mm Dia with 3m wire, indicator model : CSFPI-E-A-H |
| 31 | 8 way battery and charger I/P 230V, O/P 24V DC, 10A (flat type) (12 V X02 battery) |
| 32 | Digital MFM meter flush mounted, size-96x96mm, AC, class 1.0, Aux-40-300V AC model elite 303, CT & PT ratio programmable with RS 485 port |
| 33 | O/C & E/F self powered relay-CSDPR-V2-300-D-L-N-M-C1 with modbus 1A, AUX supply-18-60V DC O/C minimum setting-10% & E/F- minimum setting-5% |
| 34 | Local Remote switch 3 Pole/2W/ EE090691 |
| 35 | PCI / 37302001-01 |
| 36 | LBS function motor UN2-30 24VDC / 37303017-01 |
| 37 | 9 micro switch kit /33111884-01 |
| 38 | Relay electm 24V DC 5A 4C /O/ 9423140 |
| 39 | Relay electm 230V AC 5A 4C /O/ 9423142 |
| 40 | Relay electm 4C/ O BASE / 9423230 |
| 41 | Push button flush type (Red) with carrier |
| 42 | Push button flush type (Green) with carrier |
| 43 | Contact element 1 NO green Cat Rb2-BE101 |
| 44 | Terminal block fuse type elmex model=KUDF4 |
| 45 | VCB function spring charging motor, 120W 24V DC, Type:PMR5 |
| 46 | Tripping coil |
| 47 | Closing coil |
| 48 | Micro limit switch, Model-D-38, rating-16A, 1 HP, 125/250V AC |
| 49 | Aux switch 6 NO + 6 NC |
| 50 | Pressure switch/ 33210204-01 |
| 51 | 10A, 230V AC 2 pole with on/off toggle switch, CAT ; Kaycee |
| 52 | Material and Labour for GI pipe Light grade with all fittings complete laidin trenches/fixed on pole with suitable clamp all as specified for 80 mm bore of pipe for protection of UG cable, complete all as specified and as directed by Engr-in-charge. |
| 53 | Material and Labour for disc insulator porcelain vitreous brown 145 mm height & 225 mm dia ball and socket type two in series assembly with cast aluminium 4 U bolt tension hardware and tension clamps for conductors working pressure HT 22 KV, complete all as specified and as directed by Engr-in-charge. |
| 54 | Material and Labour for pin insulator porcelain vitreous brown insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut for 22000 volts grade 205 mm dia & 215 mm height, complete all as specified and as directed by Engr-in-Charge. |
| 55 | - Ditto- all as per item No 27.00 here-in-before but post type insulator. |
| 56 | Supply and install HT 22 KV Gang Operated Air Break Switch, horizontal 3 insulator type complete with handle, pipe and all mechanical fittings 400 Amps double break rotating type with earth switch, complete all as specified and as directed by Engr-in-charge. |
| 57 | Material and Labour for overhauling i.e greasing, cleaning of GOD and adjustment of its operation complete all as specified and directed by Engineer-in-Charge. |
| 58 | Material and Labour for fixed type top contact for DO fuse units in replacement , complete all as specified and as directed by Engr-in-charge. |
| 59 | Material and Labour for fixed type bottom contact for DO fuse units in replacement , complete all as specified and as directed by Engr-in-Charge. |
| 60 | Supply and Fix following spares of vertical type GOD 22 KV grade, 200 Amps rating in position as in repairs including testing after repairs, complete all as specified and as directed by Engr-in-Charge :- |
| 61 | (a)Male contact |
| 62 | (b)Female contact |
| 63 | (c)Tinned copper flexible jumper |
| 64 | (d)MS Jumper carrier |
| 65 | (e)Back connector plate |
| 66 | Supply and install HT 22 KV, 200 Amp outdoor type gang operated single break switch Tilting type vertical mounting consisting of hot dip galvanised channel iron base having 2 Nos 22 KV Post type insulator in stack and 3 stack per phase copper or copper alloy high pressure heavily tinned contacts plated MS arcing horns capable of breaking the magnetizing current complete with horizontal connecting square bar, GI pipe as down rod levers coupling & operating handle with locking arrangement, complete all as specified and as directed by Engr-in-Charge. |
| 67 | Supply and install drop out lift OFF HT 22 KV, 200 Ampsfuse link consisting of channel iron base having 2 Nos 22 KV post type insulators in stack & 2 stack per phase complete with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze contact complete manufactured as per IS 9385, complete all as specified and as directed by Engr-in-Charge. |
| 68 | Material and Labour for Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI & connected to Earthing test point and earth dolly all as shown in elect plate No 5 of SSR Pt-I including all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 15 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc all as specified and as directed by Engr-in-charge. |
| 69 | Supply and Fix earth continuity conductor or main earthing lead fixed to wall on batten or fixed to pole GI strip 32 x 6 mm, complete all as specified and as directed by Engr-in-Charge. |
| 70 | Material and Labour in repair Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, complete all as specified and as directed by Engr-in-Charge. |
| 71 | Periodical check/preventive maintenance of HT 22 KV SF-6 Gas circuit breaker HT 22 KV, 800 Amps, outdoor type controlled by indoor control panel by manufacturer\"s service Engineer/ authorised channel partner\"s for the following checks including dismantling/replacing the defective parts for smooth functioning and including testing of breaker for its closing/opening operations on manual and on remote after every check, complete all as specified and as directed by Engr-in-Charge :-(a) Servicing(i.e light primary terminals)(b) Functional checks(c) Mechanism servicing and lubrication(d) Gas leak check(e) Protection checks (Gas density switch operation)(f) Control wiring tightness(g) Power connection tightness(h) Insulation measurement of main circuit(j) Contact resistance of main circuit(k) Check relays for CT, EF & OC trip system |
| 72 | Complete overhauling of relays -1OV relay + 1 earth fault/O/C + 1 master trip relay, secondary injection on each multiple setting of relays by injecting artificial load to ascertain correctness completely including primary injection through outdoor CT\"s by injecting artificial load on each multiple setting of relay to check correctness completely including submission of calibration certificate from authorised agency, complete all as specified and as directed by Engr-in-Charge. |
| 73 | Material and Labour in repairs outdoor type, oil cooled, single phase, single pole wound primary, live tank OIP insulated current transformer dual core having ratio 120-60/1-1A (ratio change by means of tap on secondary winding) insulation Class A, burden 15 VA Class I for metering & 5P-10for protection, complete all as specified and as directed by Engr-in-Charge. |
| 74 | Supply onlythe following spare partsof HT 22 KV SF-6, 800 Amps outdoor type circuit breaker controlled by indoor panel, complete all as specified and as directed by Engr-in-Charge :- |
| 75 | Limit switch with Bracket |
| 76 | Operation Counter Assembly |
| 77 | Carbon Brushes With Cap |
| 78 | Emery Pads |
| 79 | Auxiliary switch stack 5 NO+5NC |
| 80 | Door Gasket |
| 81 | chemistic |
| 82 | compound Gauge |
| 83 | compound Gauge(small) |
| 84 | Anabond 680 (1 tube=100gms) |
| 85 | Local Remote switch 3 Pole |
| 86 | Trip Coil (single) - 30V DC |
| 87 | Close Coil - 30V DC |
| 88 | Set of Circlips, Split Pins, Dowel Pins etc |
| 89 | Darina Grease(1 Pkt= 250 Gm) |
| 90 | Torsion Spring Right |
| 91 | Torsion Spring Left |
| 92 | TNC switch 2 Pole |
| 93 | DC Contractor |
| 94 | space heater 80 W |
| 95 | Thermostat |
| 96 | Spring Charging Motor |
| 97 | SF-6 Gas filling device with gas filling |
| 98 | Anti pumping device |
| 99 | Material and Labour in repairs Low viscosity transformer oil having minimum di-electric strength 60 KV conforming to IS - 535, complete all as specified and as directed by Engr-in-Charge. |
| 100 | Material and Labour in repairs \"T\" hard connector made of cast aluminium suitable for ACSR conductor, complete all as specified and as directed by Engr-in-Charge. |
| 101 | Material and Labour in repairs 4 \"U\" bolt hardware made of cast aluminium suitable for end disc insulator, complete all as specified and as directed by Engr-in-Charge. |
| 102 | Material and Labour in replacement Bi-metallic aluminium straight connector for C.T. 32mm x DOG conductor, complete all as specified and as directed by Engr-in-Charge. |
| 103 | Material and Labour in replacement Bi-metallic aluminium straight connector for C.T. 12mm x DOG conductor, complete all as specified and as directed by Engr-in-Charge. |
| 104 | Material and Labour in repairs brass spindlewith 32mm dia for CT\"s with Universal bushing, complete all as specified and as directed by Engr-in-Charge. |
| 105 | Supply and laying in repairs synthetic Rubber insulated mats 3 mm thick for voltage upto 33 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and as directed by Engr-in-Charge. |
| 106 | Material and Labour for Heat shrinkable cable end termination joint including jointing Kit indoor/outdoor type (touch proof) suitable for earthed 3 core 95/120 sqmm HT 22KV XLPE aluminium conductor cable and HV test after jointing and connecting up, complete all as specified and as directed by Engr-in-Charge. |
| 107 | Material and Labour for Heat Shrinkable straight through jointing kit with all necessary jointing material suitable for HT 22 KV XLPE 3 core 95/120 sqmm aluminium conductor cable, complete all as specified and as directed by Engr-in-Charge. |
| 108 | Disconnecting HT 22 KV grade XLPE cable of any size from structure/pole/transformer for finding fault by computer aided fault finding machine and locating exact location by thumping and necessary earth work to expose faulty cable piece and cutting faulty cable andtesting remaining cable with High voltage tester to with stand the cable as normal working pressure HT 22 KV complete all as specified and directed by Engineer-in-Charge.Note :- Excavation and earth work and Material and Labour for joints shall be measured and paid under relevant Item of schedule separately. |
| 109 | Labour only for upkeep of HT out door structure by removing grass, shrubs, trimming branches of trees near to structure removing cleaning, screening for mud etc and relaying of same stone aggregate, complete all as specified and as directed by Engr-in-Charge. |
| 110 | Supply and Fix Auxiliary High speed Master trip relay, Type AVAJH13 , contact 3 NO+2 NC HR , Auxiliary Voltage : 24 VDC or 110 VDC, complete all as specified and as directed by Engr-in-Charge. |
| 111 | Supply and Fix 3 phase Over Current + Earth Fault Relay with High Set & RS -485 Port with IDMT and definite time characteristics, password protection, Aux supply (V) of 24-240V, AC/DC, Output contacts 4 No, complete all as specified and as directed by Engr-in-Charge. |
| 112 | Preparation of old painted surface including removing old paint, rust, dust, oil, grease and any other foreign deposits by paint removers or burning off by blow lamps and cleaning with scrapers and chemicals for removal of rust for any number of coats, any width or girth & Material and Labour application of aluminium paint one coat for 6 pole structure (steel or tubular)/ channels/angles /GODs etc, complete all as specified and as directed by Engr-in-Charge. |
| 113 | -Ditto- all as per item No 56.00 here-in-before, but 4 pole structure |
| 114 | -Ditto- all as per item No 56.00 here-in-before, but 2 pole structure |
| 115 | Supply and Fix following spares of Horizontal type GOD 22 KV grade, 400 Amps rating in position as in repairs including testing after repairs, complete all as specified and as directed by Engr-in-Charge :- |
| 116 | (a)Male contact |
| 117 | (b)Female contact |
| 118 | (c)Copper rod/Plate |
| 119 | (d) Copper Bare conductor of 4 SWG |
| 120 | (e) Copper Bare conductor of 6 SWG |
| 121 | Material and Labour for cutting and fixing of chequered plate for 4mm thick for inside/outside sub station room openable cable duct with complete fixing arrangement, all as specified and as directed by Engr-in-Charge. |
| 122 | Material and Labour for DO fuse Element stranded silver/Tin coated copper wire soldered joint with ferrule and fire resistant tube type rating 2.5Amps, complete all as specified and as directed by Engr-in-Charge. |
| 123 | -Ditto- all as per item No 61.00 here-in-before, but rating 5 Amps |
| 124 | -Ditto- all as per item No 61.00 here-in-before, but rating 10 Amps |
| 125 | -Ditto- all as per item No 61.00 here-in-before, but rating 15 Amps |
| 126 | -Ditto- all as per item No 61.00 here-in-before, but rating 20 Amps |
| 127 | -Ditto- all as per item No 61.00 here-in-before, but rating 30 Amps |
| 128 | -Ditto- all as per item No 61.00 here-in-before, but rating 40 Amps |
| 129 | -Ditto- all as per item No 61.00 here-in-before, but rating 60 Amps |
| 130 | -Ditto- all as per item No 61.00 here-in-before, but rating 80 Amps |
| 131 | -Ditto- all as per item No 61.00 here-in-before, but rating 100 Amps |
| 132 | Material and Labour for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations, complete all as specified and as directed by Engr-in-Charge. |
| 133 | Supply and filling in layers not exc 25cm thick with 40mm graded coarse aggregates in structures, complete all as specified and as directed by Engr-in-Charge. |
| 134 | Material and Labour for fixing of GI Nut and Bolts with washer of different sizes in HT structures, complete all as specified and as directed by Engr-in-Charge. |
| 135 | Material and Labour for self bonding electrical HT tape of size 1.9cm x 9.15m x 0.076cm for cable joints, transformers, HT structure joints, complete all as specified and as directed by Engr-in-Charge. |
| 136 | Material and Labour for HT lugs in the rectification of HT faults of size 95 Sqmm, complete all as specified and as directed by Engr-in-Charge. |
| 137 | Material and Labour for HT lugs in the rectification of HT faults of size 120 Sqmm, complete all as specified and as directed by Engr-in-Charge. |
| 138 | Material and Labour for HT lugs in the rectification of HT faults of size 150 Sqmm, complete all as specified and as directed by Engr-in-Charge. |
| 139 | Material and Labour for HT lugs in the rectification of HT faults of size 185 Sqmm, complete all as specified and as directed by Engr-in-Charge. |
| 140 | Material and Labour for HT lugs in the rectification of HT faults of size 240 Sqmm, complete all as specified and as directed by Engr-in-Charge. |
| 141 | Material and Labour for Petroleum Jelly in HT Nut bolt joints, T- joints, U joints in CTs and PTs on the HT structure, complete all as specified and as directed by Engr-in-Charge. |
| 142 | Supply only for HT gloves for 22 KV HT line, complete all as specified and as directed by Engr-in-Charge. |
| 143 | Material and Labour for Heat Shrinkable straight through jointing kit with all necessary jointing material suitable for HT 22 KV XLPE 3 core 300 sqmm aluminium conductor cable, complete all as specified and as directed by Engr-in-Charge. |
| 144 | Material and Labour for Heat shrinkable cable end termination joint including jointing Kit indoor/outdoor type (touch proof) suitable for earthed 3 core 300 sqmm HT 22KV XLPE aluminium conductor cable and HV test after jointing and connecting up, complete all as specified and as directed by Engr-in-Charge. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender