Agriculture Government Departments Closing in 0 days TDR #49864552

Tender For E-Tender (2Nd Call) For Procurement Of Laboratory Instruments, Equipment, Appliances For The College Of Veterinary Sciences And Ah, Rk Nagar Under The Nec Funded Project For The Year 2025-2026

Issued by Government Departments · Tripura, Tripura
Tender Value
77 Lakhs
Estimated cost
Bid Submission
24 Jul 2025
0 days left
EMD
1.55 Lakhs
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tripura → Tripura
EMD Exemption
Available
Quantity
Not Available

Project Description

E-Tender (2Nd Call) For Procurement Of Laboratory Instruments, Equipment, Appliances For The College Of Veterinary Sciences And Ah, Rk Nagar Under The Nec Funded Project For The Year 2025-2026 , Biosafety Cabinetclassii, A 2 With Accessories And Power Back Up (Bacteriology)--• The Biological Safety Cabinet Should Be Of Class Ii, Type A2 Designed In Compliance With International Standards • The Biological Safety Cabinet Quoted Instrument Model Must Have International Standards Test Likensf, Tuv Nord, En 12469 Certification. Certificate Copy Must Be Provided Along With The Technical Bid. • Working Area Should Be Around 4Foot. It Should Have Exterior Dimension W X H X D Of 1300X 1568 X 800 And Interior Dimension Wxhxdof 1200X 780X 630 • It Should Have 1 Piece Grade 304 Stainless Steel Or Thermos Scientific Smart Coat Interior • Itshouldhavefeatureforpersonalprotection,Sample Protection, Cross Contamination Protection And Environmental Protection. • It Must Utilize Brushless Dc Motor Technology Which Uses Significantly Less Energy With Less Heat Emission Provision Compared To Traditional Ac Motor Technology To Ensure Lower Levels Of Energy Consumption. • It Should Have 10° Sloped Front For Exceptional Comfort And Ergonomics • Thesystemshouldbedesignedwithdualmotor. • The Motor Must Automatically Adjust Or Control Fan Speed In Real Time To Maintain Constant Airflow During Filter Loading Or Temporary Obstruction. • Air Flow Direction: Vertical Laminar Flow & Air Intake Across Front Opening And 70% Recirculation. • Filter: High Performance Particle Air Filter H14(Hepa En1822), Filtering Efficiency 99.995% Mpps Or Better. • Energy Saving Mode When Cabinet Not In Use With Maintaining Sterility. Continuous Airflow Helps To Maintaina Sterile Environment, Evenwhen The Cabinet Is Not In Use. • Thesystemshouldhaveindependentsensorstodetect Pressure Changes Across The Exhaust And Down Flow Plenum/ Air Velocity And Should Indicate Alarm Signal When A 20-30% Change In Inflow/ Exhaust Or Down Flow Occurs. • Control Panel And Performance Monitor Displays Inflow/ Down Flow Velocities, Hours Of Use Etc. To Verify Proper Cabinet Operation. • Frontglasswindowshouldbeeasilyloweredforthorough Smart Cleaning Of Inner Surfaces And Designed To Protect Users By Maintaining Inflow, Even When The Window Is Lowered. • The Uv Light Must Be Quoted Which Should Be Programmable From 30 Min To 24 Hrs. In Minimum 30 Minutes Increment To Shut Off Automatically. The Settings Must Allow The User To Program The Timer. • The Cabinet Noise Level Must Be Less Than 63 Db(A) As Measured In A Sound Proof Room To • Promote More Comfortable And Safer Working Habitsof The User A Per Nsf/ Ansi 49. • The Controller Must Be Located On A Slanted Frontpanel So It Is Easy To See From A Seated Working Position In Front Of The Cabinet. • Control Panel Should Be A Large Digital Color Touch Screen Display With Health Monitoring System, Valuable Safety And Performance Data With Constant Read-Out Of Downflow/ Inflow Velocities And Hours Of Operation In Real-Time, Number Of Hours Of Use On The Hepa Filters. • The Front Window Sash Must Be Angled 10° Sloped Front For Operator Comfort. • Two Pieces Of Removable And Autoclavable Stainless Steel Arm Rest Should Be Provided For Operator’S Comfort Without Disturbing The Air Flow. • The System Must Have Audio Visual Alarms To Indicate When Inflow Is Restricted And As Well As Whether Front Window Is In Correct Position Or Not. • Theworkareashouldbeilluminatedwithswitchable Fluorescent Lamp Of Lighting Power >120 Fc Or Higher. • Suitable Height Floor Stand Without Casters Should Be Provided. • In Built Access Ports, 2 Nos. (1 On Each Side) Shouldbe Available. • It Has Single Piece Stainless Steel Work Tray For Easy Cleaning And Decontamination. • Warranty:Minimum3year. • Electrical Supply Available: 230V A.C, Single Phase, 50 Hz. • Bidder Should Provide Printed Brochure Of The Quoted Model And Details Specification Should Be Available In The Manufacture Website. • Customized Model Would Not Be Accepted Withoutany Quality Control Certificate Or 3Rd Party Approved Certification • Prompt & Efficient After Sales Service Should Be Available In The Eastern Region Of India. • User List: Minimum 10 Numbers Of Quoted Model Should Have Been Installed In Government • Institution(Listshouldbeenclosed). • Quotedwith2kvaservovoltagestabilizer. • Three(2)Yearswarranty. • 3Kva Stabilizer , Autoclave--• Capacity: 60L To 80 L, Vertical, Watt:3-4Kw, Operation Mode: Fully Automatic (Digital Controller With Automatic Pressure Release Valve), Construction: Double Walled Inner Chamberstainless Steel 304, External Chamber: Stainless Steel 304 Lid Stainless Steel 304, • Ring & Stand: Stainless Steel 304 Heater Immersion Heater, Gasket: High Temperature Silicone Rubber Gasket (Joint Less), Locking System Radial Locking Mechanism W/ Pedal Lifting Device/ Butterfly Nut Lid Lock. • Temperature Range: 121°C To 125°C Temperature Accuracy ±1°C • Temperaturesensor:Pt100 • Controller: • Digitaltemperaturecontroller • In-Builtdigitaltimer0-60Minutes • Endofsterilizationbuzzeralert • Digitaldisplayofpressure • Sensorbrokenindication • Pressure:15To20psior Above. • Steam Release: Automatic Steam Release After Sterilization • Releasevalve:Solenoidvalve • Pressuredisplay:Dialtypepressuregauge • Safety • Overpressuresafety Valve • Automaticvacuumbreaker • Lowwaterlevelcut-Off Sensor • Basket:Wiremeshbasket • Powersupply:220Volts50hz • Waterinletvalve • Directlypourintothe Chamber • Standardaccessories: • Waterlevelindicator(Glass) • Waterdrainvalve • Warranty:3Years(On-Site) , Bod Incubator-- • Capacity:200L • Temperaturerange:Ambient+5°Cto+60°C • Chamber:Stainlesssteel • Temperatureaccuracy:±0.5°C • No.Ofshelves:3-6 • Temperaturesensor:Pt-100 • Shelves:Perforatedstainlesssteel • Dimension:Lxwxh(Cm)-80X80x180 • Numberofdoors:1-2 • Loadperrack(Kg): 25-60 • Lighting:Interiorilluminationwithledlight. • Insidedoor:Transparentacrylic • Outsidedoor:Well Insulated • Power:Workson230vacsinglephase50hz • Displaydigitaldisplay • Warranty:3Years(On-Site) , Video Endoscopy Machine-- • Should Be Veterinary Specific & Suitable For Companion Animal As Well As Large Animal. • Gastroscopeshouldhaveintegratedvideocamera With High Source. • Shouldalsohavemedical Colonoscope. • Insertion Tube Should Be Of Extremely Short Tip With Outer Diameter Of 8.4 Mm, Working Length Should1050 Mm, Working Channel Should Be 2.8 Mm. • Should Have 4- Way Deflection (Upward 210°, Downward 90°, Left 100° And Right 100°). • Fieldofviewshouldbe120°. • Depthofviewshouldbe3-100Mm. • Should Be Provided Along With Carrying Case, Caps For Working Channel, Irrigation Tube, Cleaningbrush And Cleaning Valve. • Shouldhavebiopsyforcepsandforeignbody Forceps. • Hd Camera System Should Be Compatible With Both Flexible And Rigid Endoscope. • Should Have Internal Medical Grade Recorder For Capturing Full Hd. • Patients Informationshouldbe Editable Anddisplayed In Monitor. • Shouldbesuppliedwithmedicalgrademonitor. • Shouldbesuppliedwithtrolley. • Patients Informationshouldbe Editable Anddisplayed In Monitor. • Shouldbesuppliedwithmedicalgrademonitor. • Shouldbesuppliedwithtrolley. • Shouldprovide3-Yearwarrantyandshouldhave Oemserviceengineerpostedattripuraforregular Promptservice(Documentstobe Enclosed) , Elisareader Withaccessories Including (Absorbance Microplate Readers, Software And A Fully-Automated Elisa Processor And Powerbackup.)-- • Filter Based Elisareader With Halogen Lamp As Light Source And Single Channel Optics/ Single Detector With Silicon Photo Detectors For Reliable Results. • Halogenlampshouldhaveminimumusageoption, I.E. It’S Should Get ‘On’ While Reading And Should Be ‘Off’Mode Even The Instrument Is On Standby Mode. • Should Be Compatible To Wavelength Range From 340 To 850 Nm, Which Must For Various Elisa Applications. • Shouldhaveeasyaccess8positionfilterwheel. • Instrument Should Be Supplied With 3 Standard Filters Of 405Nm, 450Nm And 620Nm. • Should Have Automatic Calibration And Selfdiagnostics Of Any Possible Error In Optical Alignment Before Each Program Reading. • Should Able To Read 96 Well Format Microwell Plate In 6 Seconds. • The Instrument Should Run In Stand-Alone Mode Orwithcomputer&Dataanalysissoftware Controlled. • Internal Software (Standalone Mode) Should Have All The Basic Application Related To Elisa Like Quality Control, Qualitative Classification, Standard Graph Etc. • Computer Software Should Be Supplied With Unlimited User Licenses And Should Have Reading As Well As Data Analysis Option Including Standardcurve Fit, Qualitative Classifications, Quality Controletc. • Systemshouldabletoruninstand-Alonemodeusing 4.5-Inchcolourdisplayand Keypad. • The Instrument Should Have A Memory Of 99 Inbuilt Protocolsinstand-Alonemodeand100resultmemory. • The Instrument Should Have 2 Usb Ports, One For The Easy Data Transfer And Another To Connect Printer Directly To The Unit. • System Should Have Usb Port For External Printer Connectivity Option For The Data Printout. • Instrument Should Be Either Ce Mark/ Ivd/ Usfda, Authorized Certificate From Notified Body Should Be Submitted. • One(1)Year Warranty O 3Kvaonlineups O Attached With Suitable Computer Desktop With Powerbackupwithfollowingconfigurationintel I3processor12th Gen, 8Gb Ram, Ssd, Ddr-4, Hard Disk 1 Tb, 15 Monitor, Keyboard, Mouse With Computer Ups Dataanalysissoftware: O Software Should Have Option For Area Selection. I. E Differentprotocolsatdifferentareaofthesameplate. O Database Based Software To Run Backups Of All Data, Restore Back Up Data (In Case Of Hardware Failure Of Original Computer). O Singlesoftwareprogramshouldallowanynumberof Measurement Steps Within The Program. O Datashouldbeabletoexportinformatssuchas Excel,Pdf,Xml,Ornote. , Incubator (Bacteriological)-- • Controller: Microprocessor Pid Digital Controller For Temperature Control • Timer:99Hr59minorcontinuousselectable • Innermaterial:Stainlesssteel304 • Outer Material: Mild Steel With Antibacterial Powder Coated Paint • Door:Glasswindowviewingmetaldoublewalled Door • Insulation: Double Wall Construction & Mineral Wool Insulation To Avoid Heat Loss • Innerdimensions:455X455x610mm(Wxdxh) • Capacity:6Cu.Ft(Table-Topmodel) • Temperaturerange:Ambient+5°Cto100°C • Temperature Accuracy:±1°Ccontrolledwithpt-100 Sensor • Temperatureuniformity:±1°C • Heaterload:600Wheaterresistancenichromewire • Aircirculationfan:Maintainuniformtemperature • Display:Leddigitaldisplay • Shelves (Removable): Ss 304 Made 03Nos. Wire Mesh Shelves • Safety:Over/Undertemperaturealarm&Cut-Off, Over Current Breaker • Electricsupply:220V,50Hz;With3-Pinsafetyplug And Power Cord • Warranty:3Yrs , Micro Haematocrit Centrifuge-- • Motorcapacity:24X75mmlengthcapillarytubes. • Speedrangeof500-12,000Rpm,Max.Rcf12000/ 14118G. • Independentcontrolofspeedandtime. • Easyoperationwithintuitivemenuanddigitaldisplay. • Max.Speedof 12,000Rpm. • Rotor:Hctrotorwithscrewonlid. • Weight:4-8Kg • Warranty:2Years(On-Site) , Micropipetteset--• Kitshouldinclude0.2-2,2-20,20-200&100-1000Ul Single Channel Pipettes, 1Pipette Stand (6 Position), 4 Sizes Tip Boxes With Tips, Reagent Reservoir Sample, Calibration Certificate. • Alsoincludedextratwopipettes1-10Ul,10-100Ul. • Fullyautoclavable • Advancedvolumegearingmechanism • Shouldhavelarge,Easy-To-Readdisplay • Double-Action Pipetting Button With A Rotating Upper Part, For Easy And Light Volume Setting. • Shouldbelightweight,Leastrsi(Repetitivestrain Injury) • Ergonomicdesign,Separatesofttouchtipejector • Inlabcalibrationandeasymaintenance,Easytoopen • Superblowoutpistonforsmallvolumestoensure Delivery Of Micro Size Drops • Shouldbeisoandusfdacertified(Provide Document) • 2Years Warranty , Desktop Computer-- • Operatingsystem:Windows11pro(Original) • Processor:Intel®Core™I5-13500 (Upto3.8Ghz With25mbcacheand6 Cores) • Memory:8Gbddr4-3200Mhzram • Storage:1Tbhdd+512Gbssd • Graphics:Intel®Uhdgraphics770 • Chipset:Intel® • Connectivityandcommunications:Intel®Wi-Fi6e And Bluetooth® 5.3 Wireless Card • Ports: 1 Headphone/ Microphone Combo; 1 Usb Type- C 10Gbps Signalling Rate; 3 Usb Type-A • 10Gbpssignallingrate • Videoconnectors:1-Hdmi1.4;1-Displayport1.4; 1- Vga • Monitor:Size-60.5Cm,Fhd(1080P)Withips Display • Pointingdevice:Wiredmouse • Keyboard:Wired • Should Include Original Preinstalled Latest Version Microsoft Office Home, & Student 2021 Lifetime Subscription • Ups:1,000Va,360W,Withleast15-Minuteback-Up • Warranty:03Years(On-Site). , Scalding Tank (Stainlesssteel)-- • Material: Stainless Steel: 304Ssgrade- Cylindricalshapedwith Legs-Drum1.2 Mm Thickness With Lid. • Drumcapacity–50–60Litres • Capacity–2-3Birds • Electricalheater–2Kwcapacity • Power:230-240V/50Hz. • Controlpanelwithdigitaltemperatureindicators.Type: Electrically Operated , Clinical Haematologyanalyser(Five Part)--• Fullyautomatic Veterinary Hematologyanalyzer For Analysis Of Different Species Of Domestic, Pet Animals, Lab Animals And Wild Animals’ Blood. • Flow Cytometry (Fcm), Tri-Angle Laser Scatter, Chemical Dye Method And Independent Basophilchannel Etc./ And Other Advance Method • 5 Parts For Different Wbc Count With Veterinary Animal Species Specific Software • Minimum23parameters:Wbc,Lym%,Mon%,Neu %, Eos%, Bas%, Lym#, Mon#, Neu#, Eos#, Bas#, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct. • 3Histogramforrbc,Wbc&Plt • 3Scattergramsforwbcdifferential • Samplevolume<20?L,Tfttouchscreendisplay • Canprocess Upto60samplesperhour • Storageupto30,000Samplereport. • Keyboard,Externalinkjetprinter,Supportedbyuser- Defined Report Format Print Out (A4 Size) • Fullsetconsumablereagentsuppliedalongwith Instrument. • Onlineups1kva,360Wwith15-30Minbackup • Shouldprovide3yearswarrantyandshouldhaveoem Serviceengineerpostedattripuraforregularand Prompt Service (Documents To Be Submitted Along With Enit) , Electric Stunner--• Stunner With Ss Tongs To Operate On Sheep/ Goats And Pigs. • Thecontrolboxwithanaloguedisplayfor0–110 Voltsand2ampere. • Withdigitaltimer. • Stunnerwithcontrolbox. , Portablecolouranalyser-- • Digitalcolourmeterthatmeasurescolourinlab • Colourspace:Cielab • Colourdifferenceformula:?E*Ab • Measurementcaliber:F8mm • Lightsource:D65 • Sensor:Photodiodearray • Observer:Cie10°Standardobserver • Measurementrange:L:0To100 • Repeatedaccuracy:?E<0.1 • Tabledifference:?E<0.2 • Measurementinterval:1Sec. • Storage Capacity: Type Sample Data: 100 Groups With Testing Sample Data: 100 Groups • Lifetimeofbulb:Minimum5years. • Displayscreen:Tfttruecolour 2.8Inch@(16:9) • Language:English , Mufflefurnace--• Temperaturerangesupto1000oc,Workingtemperature Upto950oc,Size19x16x18(L X W X H)Inches, 220/ 230-Volt, Warranty: 02 Year (On-Site) , Mixer Grinder--• No Of Jars: 3; Jar Size: Wet Jar (1.5 Litres), Multipurposejar(1Litre),Chutneyjar(0.3Litres);Jar Material: Stainless Steel; Body Material: Abs; Blade Material: Stainless Steel; Speed Control: 3 Speed Control+Pulse,Wattage:1000W;Voltage:230V, Warranty:01Year(On-Site) , Labwilly Mill--• Bodymaterial.Ms,Powersource.Electric,Voltage- 240V,Frequency-50Hz,Powerconsumption-0.75 Kw,Load.43Kg. , Digital Camera--• 24.1-Megapixelaps-Ccmossensor&Digic4+ Image Processor • 9-Pointafwith1centrecross-Typeafpointand Standard Iso 100 - 6400 (Expandable To 12 800) • Displaysize:3Inch • Lenstype:Opticalzoom • Digitalcameralensef-S18-55Mmf/3.5-5.6Isii , Exhibition Panel/Panel Board With Stand--• Size:10X4feet • Usage/Applicationexhibition • Size10x4feet • Framematerialaluminum • Mountingfreestanding • Shaperectangular • Thickness2.5-10Mm , Rms Speakers-- • 100Watts,Sta-150,Withtripodstandofheight Adjustment: 3.5Ft-6.5 Ft, • Loadcapacity;40Kg, • Warranty:1Years , Wireless Microphone-- Audiooutput:0110Mv/600,Freq.Resp:50-15000Hz, Antenna: Detachable Through Bnc Connector, Power: Ac-220-240Foracadopter,Modulationmade: Fm(F3e), Warranty: 1 Years. , Amplifier-- Ac&24Vdcoperated,250Watts,6Mic&2Aux, Warranty: 1 Year. , Publicaddress With Speaker--Pasystemwithabuilt-Inamplifier,Bluetooth,Usb, Recording,Andecho.Elegant,Rugged&Easytocarry Amplifier Which Delivers 20W (Max.) Output Power. Built-Indigitalmp3playerwithrecordingandbluetooth Function. Built-In Digital Echo. , Interactive Board--Size-75With4kultrahighdefinition(3840X2160) @ 60Hz With Oled Display Technology With 8 Ms Response Time, 20 Points Ir Multi Touch Interface, 3 Hdmi, 4 Usb, Bare Dimension Of 1990 X 114 X 1201 Mm With <320W Power Consumption, Build In Android 8.0 With < 3 Gb Ram And < 32 Gb Rom With Ops<I5 Ori78gbramand1tbssd,Builtinwi-Fi,Warranty Period: -3Yearsfromthedateofinstallation. , Video Camera (Hd)-- Sensorsize:23.5Mmx15.7Mm,Imagesensortype: Cmos, Total Pixels 21.51 Million, Dust-Reduction Systemimage Dust Off Reference Data (Nx Studio Software Required)Effective Pixels (Megapixels) 20.9 Million,Imagesensorformat,Aps-Csize/Dx-Format, Filesystem Dcf2.0, Exif 2.31,Cardslot, Singleslot, Focus Point 209, Flash Compensation -3 To +1 Ev In Steps Of 1/ 3 Ev Available In Modes P, S,A, And M, Monitorsize7.5-Cm(3.0–In.)Diagonal,Monitor Resolution: Approx. 1040 K-Dot. , Antibiotic Zone Reader--• Accuratereadingofthezoneinmmondigital Display • Resolution: 0.1 Mm. Electronic Zero Adjustment Eliminate Tedious Zero Setting On The Scale. No Parallax So No Human Error In Reading. Fine Focus Adjustmentfor Clear Image On Viewing Glass. No Effect Of Ambient Light On Image. Halogen Lamp For Sharp And Bright Optical Imaging And Also Should Have Long Life. User Friendly Design To Operate The Instrument. Range: 0 To 80.0Mm.Leastcount0.1Mm. • Display:3-Digit7segmentred Led. • Powersupply:230V,50Hzac. • Dimension: 370 W X 380 D X 220 Mm H. Weight: 8 Kg Approx. • Warranty:1Years , Eddy’Shot Plate--• Hot Plate Analgesiometer (Eddy’S Hot Plate) Is Developed To Perform Rapid & Precise Screening Of Analgesic Drug Properties On Small Laboratory Animals. • Plate Temperature Can Be Held At Set Point Between 5? Above Ambient To 60? (± 2?). • Resolutionofreactiontime:0.1Second,Cutoffthe Timertoavoiddamagetotheanimal. • Top Lid Sensor To Indicate Lid Is Open And Thereof Avoiding Temperature Fluctuations. • Pcconnectivitywithsoftware. • Software Has Provision To Add Titles, Comments, Graphical Presentations And Data Can Be Converted Into Excel Or Pdf. • Mustbesuppliedwithpcwithaccessories& Software. • Withfreeinstallation&Commissioning. • Warranty:1Years(On-Site) , Digital Plethysmometer--• Digital Plethysmometer Is A Micro Controlled Volume Meter, Designed For Accurate Measurement Of The Rat/ Mouse Paw Swelling And Used For Evaluation Of Ant- Inflammatory And Anti-Oedema Properties Of Pharmacological Substances. The Water Displacement Produced By The Immersion Of The Animal Paw In The Measuring Tube Is Reflected Into The Second Tube, Inducing A Change In The Conductance Between The Two Platinum Electrodes. The Plethysmometer Control Unit Detects The Conductance Changes And Generates An Output Signal To The Digital Display Indicating The Volume Displacement Measured (0.01 Ml Resolution). The Current Value Remains In The Digital Display Until A Newtrialstarts.Thecontrolunit Canbezeroedbetween Successive Readings By Pressing The Zero Button. • Keyfeatures: O Animalstobetested:Mouse&Rat O Resolution:0.01Ml O Digital Display With Easy Pedal Switch Control, Evaluation Of Small Volume Differences, Comfortable Readingonlcdgraphicdisplay,Connectivitytopc Andmustbesuppliedwithpcwithrequired Software, Must Include Free Installation & Commissioning. Warranty: 1 Years (On-Site) , Electric Dehorner-- • Material:Stainlesssteel • Automationgrade:Automatic • Producttype:Electricandstainlesssteel • Capacity:50Hz • Warranty:2Years(On-Site) , Community Nest Box-- • Apoultryhousingmodelfordemonstrationtostudents. • Productdimensions:45.6Lx13Wx26H • Material:Alloysteel , Feedgrinder (Mini)(For Poultry/Cattle Feed)-- • Grindermachine(Forpoultry/Cattlefeed): • Motor: 2 Hp, Capacity – 200-300 Kg/ Hour, Material – Mildsteel,Inputvoltage–220V,Phase–Single,Sieve – 3 Mm Holes (2 No), Additional Spares – Sieve: 2.5 Mm Hole – 1 No & 4 Mm Hole Sieve – 1 No, Beaters: 1 Set, Grinder Fixed On Rot Iron Angle. • Withfreeinstallation,Fittingfixing&Commissioning. • Warranty:2Years(On-Site). , Feedmixer (Mini) (Forpoultry/ Cattle Feed)-- • Mixerforpoultry/Cattlefeed: • Horizontal Mixer, Motor: 2Hp, Mixingvolume 70-100 Kg/Batch,Mixingtime–8-10Minute/Batch,Single Phase,Mixerfixedonrotmmmironangle,Material: Ms. • Withfreeinstallation,Fittingfixing&Commissioning. • Warranty:2Years(On-Site). , Physiograph--Student Physiograph Recorder Is A Highly Sensitivity Oscillograph Mainly Being Used For Teaching Experiment Physiology And Pharmacology. Digitalstudentphysiographfeatures • Standalone Unit Having Coloured Tft Display For Displaying Online And Offline Recording Data. • Digitalphysiographwithtimeandeventchannel. • Compact, Lightweight And Easy To Operate By Abeginner. • System Has 6 Couplers Fitted In A Single Unit Making It Easy To Carry. • System Has 8 Transducers (Force, Pressure, Volume, Respiration, Temperature, Pulse, Respiration Belt And Isotonic) • Interface To The Computer-Through Usb • System Is Supplied With Pc & Software To Review And Print The Recorded Data From Pc. Studentphysiographcomprises Ofcouplersto Record Different Parameters The Standard Range Ofcouplers Are As Follows A) Biopotential Coupler: Bio-Potential Coupler Is Designed To Record Almost All Kinds Of Ac Phenomena Like Ecg, Eeg, Emg, Erg Or Any Other A.C. Phenomenon. Isotonic Coupler: For Recording With Isotonic Fine Movement Transducer. Strain Gage Coupler: Coupler For Recording From All Strain Gage Transducers &Use To Record Muscle Activity Force, Effect Of Drug On Heart Activity Etc Pulse-Respiration Couplers: For Recording Pulse Or Respiration Using Photo-Electric Transducers. Temperature Coupler: For Recording Internal Or Surface Temperature Through Orchid Temperature Transducers: Atransducerisadevicewhichconvertsoneformof Physical Energy To Electrical Energy Or Vice Versa. • Warranty:2Years(On-Site). • Mustincludefreeinstallation&Commissioning. , Milkingmachine--• Noofbuckets:1.0 • Productivity:1-10Cows/Hour • Capacity:25Litre • Automationgrade:Semi-Automatic • Powerinput(W):110W • Voltage(V):110-220V • Frequency(Hz):50/60 Hz • Warranty:4Years(On-Site) • Mustincludefreeinstallation&Commissioning. , Demonstration Modelofcow-- • Naturalsize,Detachableskintoshowsuperficialand Deep Muscle. • Headandneckdetachableanddissectible. • Visceraearedissectibletodemonstratevarioussystems Within The Organ Are Also Detachable. • Detachablehoof , Captivebolt Pistol--• Non-Penetrativeconcussionstunner • Universalinapplicationfromlargebullstosmalllambs, With Varying Power Load Strengths • Wellbalanced,Comfortableergonomicallydesigned Handle • Automaticboltreturn • Legalpermissionrequired • Standardtoolin0.22Or0.25Calibre. • Robustsolidconstruction. • Features/Specifications: • Chromesteel Finish • Knurledhandleforbettergrip • Fewerpartsthancompetitivebrands • Boltpenetrates2.25

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 16-Jul-2025 Corrigendum Date 24-Jul-2025

BOQ

Name of Work: e-Tender (2nd Call) for procurement of Laboratory Instruments/equipment/appliances for the College of Veterinary Sciences & Animal Husbandry under the NEC funded project entitled: “Strengthening of Laboratories at College of Veterinary Sciences & A.H., R.K. Nagar, West Tripura” for the year 2025-2026.
Sl. No. Item Description
1Biosafety cabinetclassII, A 2 with accessories and power back up (Bacteriology)--• The Biological Safety Cabinet should be of Class II, Type A2 designed in compliance with International Standards• The Biological Safety Cabinet quoted instrument model must have international standards test likeNSF, TUV NORD, EN 12469 Certification. Certificate copy must be provided along with the technical bid.• Working area should be around 4foot. It should have exterior dimension W X H X D of 1300x 1568 x 800 and interior dimension WXHXDof 1200x 780x 630• It should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior• ItshouldhavefeatureforPersonalProtection,Sample Protection, Cross Contamination Protection and Environmental Protection.• It must utilize Brushless DC motor technology which uses significantly less energy with less heat emission provision compared to traditional AC motor technology to ensure lower levels of energy consumption.• It should have 10° sloped front for exceptional comfort and ergonomics • Thesystemshouldbedesignedwithdualmotor.• The motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction.• Air Flow Direction: Vertical Laminar Flow & Air intake across front opening and 70% recirculation.• Filter: High performance particle air filter H14(HEPA EN1822), filtering efficiency 99.995% MPPS or better.• Energy saving mode when cabinet not in use with maintaining sterility. Continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use.• Thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs.• Control Panel and Performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation.• Frontglasswindowshouldbeeasilyloweredforthorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered.• The UV light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. The settings must allow the user to program the timer.• The cabinet noise level must be less than 63 dB(A) as measured in a sound proof room to• promote more comfortable and safer working habitsof the user a per NSF/ ANSI 49.• The controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet.• Control panel should be a large digital color Touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the HEPA filters.• The front Window sash must be angled 10° sloped front for operator comfort.• Two pieces of removable and autoclavable stainless steel Arm rest should be provided for operator’s comfort without disturbing the Air Flow.• The system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not.• TheWorkAreashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher.• Suitable height floor stand without casters should be provided.• In built Access ports, 2 nos. (1 on each side) shouldbe available.• It has Single piece stainless steel work tray for easy Cleaning and decontamination.• Warranty:Minimum3year.• Electrical Supply Available: 230V A.C, single phase, 50 Hz.• Bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website.• Customized Model would not be accepted withoutany quality control certificate or 3rd Party approved certification• Prompt & efficient after sales service should be available in the Eastern Region of India.• User List: Minimum 10 numbers of quoted model should have been installed in Government• Institution(Listshouldbeenclosed).• Quotedwith2KVAservovoltagestabilizer.• Three(2)yearsWarranty. • 3KVA stabilizer
2Autoclave--• Capacity: 60L to 80 L, Vertical, Watt:3-4KW, Operation Mode: Fully automatic (Digital Controller with Automatic Pressure Release Valve), Construction: Double Walled Inner ChamberStainless steel 304, External chamber: Stainless steel 304 Lid Stainless steel 304,• Ring & Stand: Stainless steel 304 Heater Immersion heater, Gasket: High temperature silicone rubber gasket (Joint less), Locking system Radial locking mechanism w/ pedal lifting device/ butterfly Nut Lid Lock.• Temperature range: 121°C to 125°C Temperature accuracy ±1°C• Temperaturesensor:PT100• Controller:• Digitaltemperaturecontroller• In-builtdigitaltimer0-60minutes• ENDofsterilizationbuzzeralert• Digitaldisplayofpressure• Sensorbrokenindication• Pressure:15to20psior above.• Steam release: Automatic steam release after sterilization• Releasevalve:Solenoidvalve• Pressuredisplay:Dialtypepressuregauge• Safety• Overpressuresafety valve• Automaticvacuumbreaker• Lowwaterlevelcut-off sensor• Basket:Wiremeshbasket• Powersupply:220Volts50Hz• WaterInletValve• Directlypourintothe chamber• Standardaccessories:• Waterlevelindicator(glass)• Waterdrainvalve• Warranty:3years(on-site)
3BOD Incubator-- • Capacity:200L• TemperatureRange:Ambient+5°Cto+60°C• Chamber:Stainlesssteel• TemperatureAccuracy:±0.5°C• No.ofShelves:3-6• Temperaturesensor:PT-100• Shelves:Perforatedstainlesssteel• Dimension:LxWxH(cm)-80x80x180• Numberofdoors:1-2• Loadperrack(kg): 25-60• Lighting:InteriorilluminationwithLEDLight.• Insidedoor:Transparentacrylic• Outsidedoor:Well insulated• Power:Workson230VACsinglephase50Hz• DisplayDigitaldisplay• Warranty:3years(on-site)
4Video Endoscopy Machine--• Should be veterinary specific & suitable for companion animal as well as large animal.• Gastroscopeshouldhaveintegratedvideocamera with high source.• Shouldalsohavemedical colonoscope.• Insertion tube should be of extremely short tip with outer diameter of 8.4 mm, working length should1050 mm, working channel should be 2.8 mm.• Should have 4- way deflection (upward 210°, downward 90°, left 100° and right 100°).• Fieldofviewshouldbe120°.• Depthofviewshouldbe3-100mm.• Should be provided along with Carrying Case, Caps for Working Channel, Irrigation Tube, CleaningBrush and Cleaning Valve.• ShouldhaveBiopsyforcepsandforeignbody forceps.• HD camera system should be compatible with both flexible and rigid endoscope.• Should have internal Medical grade recorder for Capturing FULL HD.• Patient\"s informationshouldbe editable anddisplayed in monitor.• ShouldbesuppliedwithMedicalGradeMonitor.• Shouldbesuppliedwithtrolley.• Patient\"s informationshouldbe editable anddisplayed in monitor.• ShouldbesuppliedwithMedicalGradeMonitor.• Shouldbesuppliedwithtrolley.• Shouldprovide3-yearWarrantyandshouldhave OEMServiceengineerpostedatTripuraforregularpromptservice(Documentstobe enclosed)
5ELISAreader Withaccessories Including (Absorbance microplate readers, software and a fully-automated ELISA processor and powerbackup.)-- • Filter based ELISAreader with halogen lamp as light source and single channel optics/ single detector with silicon photo detectors for reliable results.• HalogenLampshouldhaveminimumusageoption,i.e. it’s should get ‘on’ while reading and should be ‘off’mode even the instrument is on standby mode.• Should be compatible to wavelength range from 340 to 850 nm, which must for various ELISA applications.• Shouldhaveeasyaccess8positionfilterwheel.• Instrument should be supplied with 3 standard filters of 405nm, 450nm and 620nm.• Should have automatic calibration and selfdiagnostics of any possible error in optical alignment before each program reading.• Should able to read 96 well format microwell plate in 6 seconds.• The instrument should run in stand-alone mode ORwithcomputer&dataanalysissoftware controlled.• Internal software (standalone mode) should have all the basic application related to ELISA like quality control, qualitative classification, standard graph etc.• Computer software should be supplied with unlimited user licenses and should have reading as well as data analysis option including standardcurve fit, qualitative classifications, quality controletc.• Systemshouldabletoruninstand-alonemodeusing4.5-inchcolourdisplayand keypad.• The instrument should have a memory of 99 inbuilt protocolsinstand-alonemodeand100resultmemory.• The instrument should have 2 USB ports, one for the easy data transfer and another to connect printer directly to the unit.• System should have USB port for external printer connectivity option for the data printout.• Instrument should be either CE mark/ IVD/ USFDA, authorized certificate from notified body should be submitted.• One(1)year warrantyo 3KVAonlineUPSo Attached with suitable Computer desktop with powerbackupwithfollowingconfigurationIntel i3processor12th Gen, 8GB RAM, SSD, DDR-4, Hard disk 1 TB, 15\"\" Monitor, Keyboard, Mouse with computer UPSDataAnalysisSoftware:o Software should have option for area selection. i. e differentprotocolsatdifferentareaofthesameplate.o Database based software to run backups of all data, restore back up data (in case of hardware failure of original computer).o Singlesoftwareprogramshouldallowanynumberof measurement steps within the program.o Datashouldbeabletoexportinformatssuchasexcel,pdf,xml,ornote.
6Incubator (Bacteriological)--• Controller: Microprocessor PID Digital Controller for temperature control• Timer:99hr59minorContinuousSelectable• InnerMaterial:StainlessSteel304• Outer Material: Mild Steel with Antibacterial Powder Coated Paint• Door:GlassWindowViewingMetalDoubleWalled Door• Insulation: Double Wall Construction & Mineral Wool Insulation to avoid heat loss• InnerDimensions:455x455x610mm(WxDxH)• Capacity:6Cu.Ft(Table-TopModel)• TemperatureRange:Ambient+5°Cto100°C• Temperature Accuracy:±1°CControlledwithPT-100 Sensor• TemperatureUniformity:±1°C• HeaterLoad:600WHeaterresistanceNichromewire• AirCirculationFan:MaintainUniformTemperature• Display:LEDDigitalDisplay• Shelves (Removable): SS 304 made 03nos. Wire Mesh Shelves• Safety:Over/UnderTemperatureAlarm&Cut-Off, Over Current Breaker• ElectricSupply:220V,50Hz;with3-pinsafetyplug and Power cord• Warranty:3yrs
7Micro haematocrit Centrifuge--• MotorCapacity:24x75mmlengthCapillarytubes.• Speedrangeof500-12,000rpm,max.RCF12000/ 14118g.• Independentcontrolofspeedandtime.• EasyoperationwithintuitivemenuandDigitaldisplay.• Max.speedof 12,000rpm.• Rotor:HCTRotorwithscrewonlid.• Weight:4-8Kg• Warranty:2years(on-site)
8Micropipetteset--• Kitshouldinclude0.2-2,2-20,20-200&100-1000ulSingle Channel Pipettes, 1Pipette Stand (6 Position), 4 Sizes Tip Boxes with Tips, Reagent Reservoir Sample, Calibration Certificate.• Alsoincludedextratwopipettes1-10ul,10-100ul.• FullyAutoclavable• Advancedvolumegearingmechanism• Shouldhavelarge,easy-to-readdisplay• Double-action pipetting button with a rotating upper part, for easy and light volume setting.• Shouldbelightweight,leastRSI(RepetitiveStrain Injury)• Ergonomicdesign,separatesofttouchtipejector• Inlabcalibrationandeasymaintenance,easytoopen• Superblowoutpistonforsmallvolumestoensure delivery of micro size drops• ShouldbeISOandUSFDACertified(provide document)• 2years warranty
9Desktop Computer--• OperatingSystem:Windows11Pro(original)• Processor:Intel®Core™i5-13500(upto3.8GHz with25MBcacheand6 cores)• Memory:8GBDDR4-3200MHzRAM• Storage:1TBHDD+512GBSSD• Graphics:Intel®UHDGraphics770• Chipset:Intel®• ConnectivityandCommunications:intel®Wi-Fi6E and Bluetooth® 5.3 wireless card• Ports: 1 headphone/ microphone combo; 1 USB Type- C 10Gbps signalling rate; 3 USB Type-A• 10Gbpssignallingrate• VideoConnectors:1-HDMI1.4;1-DisplayPort1.4;1- VGA• Monitor:size-60.5cm,FHD(1080p)withIPS display• PointingDevice:WiredMouse• Keyboard:Wired• Should include original preinstalled latest version Microsoft Office Home, & Student 2021 Lifetime Subscription• UPS:1,000VA,360W,withleast15-minuteback-up• Warranty:03years(on-site).
10Scalding Tank (StainlessSteel)-- • Material: Stainless steel: 304SSGrade- CylindricalShapedwith legs-drum1.2 mm thickness with Lid.• DrumCapacity–50–60Litres• Capacity–2-3Birds• ElectricalHeater–2kwCapacity• Power:230-240V/50Hz.• Controlpanelwithdigitaltemperatureindicators.Type: Electrically operated
11Clinical HaematologyAnalyser(Five part)--• FullyAutomatic Veterinary HematologyAnalyzer for analysis of Different species of Domestic, pet animals, Lab animals and wild animals’ blood.• Flow Cytometry (FCM), Tri-angle laser scatter, chemical dye method and independent basophilchannel etc./ and other advance method• 5 parts for different WBC count with veterinary animal species specific software• Minimum23parameters:WBC,Lym%,Mon%,Neu%, Eos%, Bas%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, Hgb, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT.• 3HistogramforRBC,WBC&PLT• 3scattergramsforWBCdifferential• Samplevolume<20µl,TFTTouchscreendisplay• Canprocess upto60samplesperhour• Storageupto30,000samplereport.• Keyboard,Externalinkjetprinter,supportedbyuser- defined report format print out (A4 size)• Fullsetconsumablereagentsuppliedalongwith instrument.• OnlineUPS1KVA,360Wwith15-30minbackup• Shouldprovide3yearswarrantyandshouldhaveOEM serviceEngineerpostedatTripuraforregularandprompt service (Documents to be submitted along with eNIT)
12Electric Stunner--• Stunner with SS tongs to operate on Sheep/ goats and Pigs.• Thecontrolboxwithanaloguedisplayfor0–110Voltsand2Ampere.• WithDigitaltimer.• Stunnerwithcontrolbox.
13PortableColourAnalyser-- • DigitalcolourmeterthatmeasurescolourinLAB• ColourSpace:CIELAB• ColourDifferenceFormula:△E*ab• MeasurementCaliber:φ8mm• LightSource:D65• Sensor:Photodiodearray• Observer:CIE10°Standardobserver• MeasurementRange:L:0to100• RepeatedAccuracy:△E<0.1• TableDifference:△E<0.2• MeasurementInterval:1Sec.• Storage Capacity: Type sample data: 100 groups with testing sample data: 100 groups• LifetimeofBulb:Minimum5years.• DisplayScreen:TFTtruecolour 2.8inch@(16:9)• Language:English
14MuffleFurnace--• Temperaturerangesupto1000oC,workingtemperatureupto950oC,size19x16x18(L X W X H)inches, 220/ 230-volt, Warranty: 02 year (on-site)
15Mixer Grinder--• No of Jars: 3; Jar Size: Wet Jar (1.5 Litres), MultipurposeJar(1Litre),ChutneyJar(0.3Litres);Jar Material: Stainless Steel; Body Material: ABS; Blade Material: Stainless Steel; Speed Control: 3 Speed Control+Pulse,Wattage:1000W;Voltage:230V,Warranty:01year(on-site)
16LabWilly mill--• BodyMaterial.MS,PowerSource.Electric,Voltage- 240V,Frequency-50Hz,PowerConsumption-0.75kW,Load.43Kg.
17Digital Camera--• 24.1-megapixelAPS-CCMOSsensor&DIGIC4+ image processor• 9-pointAFwith1centrecross-typeAFpointand Standard ISO 100 - 6400 (expandable to 12 800)• DisplaySize:3Inch• LensType:OpticalZoom• DigitalCameraLensEF-S18-55mmf/3.5-5.6ISII
18Exhibition Panel/Panel Board with stand--• Size:10x4Feet• Usage/ApplicationExhibition• Size10x4Feet• FrameMaterialAluminum• MountingFreeStanding• ShapeRectangular• Thickness2.5-10mm
19RMS Speakers--• 100Watts,STA-150,withtripodstandofheight adjustment: 3.5ft-6.5 ft,• LoadCapacity;40Kg,• Warranty:1years
20Wireless Microphone-- AudioOutput:0110mV/600,Freq.Resp:50-15000Hz, Antenna: Detachable through BNC Connector, power: AC-220-240forACadopter,ModulationMade: FM(F3E), Warranty: 1 years.
21Amplifier--AC&24VDCOperated,250Watts,6Mic&2Aux, Warranty: 1 year.
22PublicAddress with Speaker--PAsystemwithabuilt-inamplifier,Bluetooth,USB, recording,andecho.Elegant,rugged&easytocarry amplifier which delivers 20W (max.) output power.Built-indigitalMP3playerwithrecordingandBluetooth function. Built-in digital echo.
23Interactive board--Size-75\"with4KUltraHighDefinition(3840X2160) @ 60Hz with OLED display technology with 8 MS response time, 20 points IR multi touch interface, 3 HDMI, 4 USB, Bare dimension of 1990 X 114 X 1201 mm with <320W power consumption, build in android8.0 with < 3 GB RAM and < 32 GB ROM with OPS
24Video Camera (HD)-- SensorSize:23.5mmx15.7mm,ImageSensorType: CMOS, Total Pixels 21.51 million, Dust-Reduction SystemImage Dust Off reference data (NX Studio software required)Effective Pixels (Megapixels) 20.9 million,ImageSensorFormat,APS-Csize/DX-format, FileSystem DCF2.0, Exif 2.31,CardSlot, SingleSlot, Focus Point 209, Flash Compensation -3 to +1 EV in steps of 1/ 3 EV available in modes P, S,A, and M,MonitorSize7.5-cm(3.0–in.)diagonal,Monitor Resolution: Approx. 1040 k-dot.
25Antibiotic zone reader--• AccuratereadingofthezoneinmmonDigital display• Resolution: 0.1 mm. Electronic Zero adjustment eliminate tedious zero setting on the scale. No parallax so no human error in reading. Fine focus adjustmentfor clear image on viewing glass. No effect of ambient light on image. Halogen lamp for sharp and bright optical imaging and also should have long life. User friendly design to operate the instrument. Range: 0 to80.0mm.Leastcount0.1mm.• Display:3-digit7segmentRed LED.• PowerSupply:230V,50HZAC.• Dimension: 370 W X 380 D X 220 mm H. Weight: 8 Kg approx.• warranty:1years
26EDDY’SHOT PLATE--• Hot plate Analgesiometer (EDDY’S HOT PLATE) is developed to perform rapid & precise screening of analgesic drug properties on small laboratory animals.• Plate temperature can be held at set point between 5℃ above ambient to 60℃ (± 2℃).• Resolutionofreactiontime:0.1Second,cutoffthetimertoavoiddamagetotheanimal.• Top LID Sensor to indicate lid is open and thereof avoiding temperature fluctuations.• PCconnectivitywithsoftware.• Software has provision to add titles, comments, graphical presentations and data can be converted into Excel or pdf.• MustbesuppliedwithPCwithaccessories& software.• Withfreeinstallation&commissioning.• Warranty:1years(on-site)
27Digital Plethysmometer--• Digital plethysmometer is a micro controlled volume meter, designed for accurate measurement of the rat/ mouse paw swelling and used for evaluation of ant- inflammatory and anti-oedema properties of pharmacological substances. The water displacement produced by the immersion of the animal paw in the measuring tube is reflected into the second tube, inducing a change in the conductance between the two platinum electrodes. The plethysmometer control unit detects the conductance changes and generates an output signal to the digital display indicating the volume displacement measured (0.01 ml resolution). The current value remains in the digital display until a newtrialstarts.Thecontrolunit canbezeroedbetween successive readings by pressing the ZERO button.• KEYFEATURES:o Animalstobetested:Mouse&Rato Resolution:0.01mlo Digital display with easy pedal switch control, evaluation of small volume differences, comfortable readingonLCDgraphicDisplay,connectivitytoPC andmustbesuppliedwithpcwithrequiredsoftware, must include free installation & commissioning. Warranty: 1 years (on-site)
28Electric dehorner-- • Material:StainlessSteel• AutomationGrade:Automatic• ProductType:Electricandstainlesssteel• Capacity:50HZ• Warranty:2years(on-site)
29Community Nest Box--• Apoultryhousingmodelfordemonstrationtostudents.• ProductDimensions:45.6\"Lx13\"Wx26\"H• Material:AlloySteel
30Feedgrinder (Mini)(for poultry/cattle feed)-- • Grindermachine(forpoultry/cattlefeed):• Motor: 2 HP, capacity – 200-300 kg/ hour, material – MildSteel,Inputvoltage–220V,Phase–single,sieve – 3 mm holes (2 no), additional spares – sieve: 2.5 mm hole – 1 no & 4 mm hole sieve – 1 no, Beaters: 1 set, grinder fixed on rot iron angle.• Withfreeinstallation,fittingfixing&commissioning.• Warranty:2years(on-site).
31Feedmixer (Mini) (forpoultry/ cattle feed)--• Mixerforpoultry/cattlefeed:• Horizontal mixer, Motor: 2HP, mixingvolume 70-100 kg/batch,mixingtime–8-10minute/batch,singlephase,mixerfixedonrotmmmironangle,material: MS.• Withfreeinstallation,fittingfixing&commissioning.• Warranty:2years(on-site).
32Physiograph--STUDENT PHYSIOGRAPH recorder is a highly sensitivity oscillograph mainly being used for teaching experiment physiology and pharmacology.DigitalStudentPhysiographFeatures• Standalone unit having coloured TFT display for displaying online and offline recording data.• DigitalPhysiographwithtimeandEventchannel.• Compact, lightweight and easy to operate by abeginner.• System has 6 couplers fitted in a single unit making it easy to carry.• System has 8 transducers (Force, Pressure, Volume, Respiration, Temperature, Pulse, Respiration Belt and Isotonic) • Interface to the computer-Through USB• System is supplied with PC & software to review and print the recorded data from PC.STUDENTPHYSIOGRAPHComprises OfCouplersTo record different parameters the standard range ofcouplers are as followsa) Biopotential Coupler: Bio-Potential coupler is designed to record almost all kinds of AC Phenomena like ECG, EEG, EMG, ERG or any other A.C. Phenomenon.Isotonic Coupler: for recording with Isotonic Fine movement transducer.Strain Gage Coupler: Coupler for recording from all Strain Gage Transducers &Use to record muscle activity force, effect of Drug on heart activity etcPulse-Respiration Couplers: For recording Pulse or respiration using Photo-electric transducers.Temperature Coupler: for recording internal or surface temperature through orchid temperatureTransducers:Atransducerisadevicewhichconvertsoneformof physical energy to electrical energy or vice versa.• Warranty:2years(on-site).• Mustincludefreeinstallation&commissioning.
33MilkingMachine--• NoofBuckets:1.0• Productivity:1-10cows/hour• Capacity:25Litre• AutomationGrade:Semi-Automatic• PowerInput(W):110W• Voltage(V):110-220V• Frequency(Hz):50/60 Hz• Warranty:4years(on-site)• Mustincludefreeinstallation&commissioning.
34Demonstration ModelofCow-- • Naturalsize,detachableskintoshowsuperficialand deep muscle.• Headandneckdetachableanddissectible.• Visceraearedissectibletodemonstratevarioussystems within the organ are also detachable.• Detachablehoof
35CaptiveBolt Pistol--• Non-penetrativeconcussionstunner• Universalinapplicationfromlargebullstosmalllambs, with varying power load strengths• Wellbalanced,comfortableergonomicallydesigned handle• Automaticboltreturn• Legalpermissionrequired• Standardtoolin0.22or0.25calibre.• Robustsolidconstruction.• Features/Specifications:• Chromesteel finish• Knurledhandleforbettergrip• Fewerpartsthancompetitivebrands• Boltpenetrates2.25\"

AI Tender Summary

OUR REF NO 49864552
AUTHORITY Government Departments
TENDER VALUE 77 Lakhs
LAST DATE 24-07-2025
Authority
Authority Name Animal Resources Development Department
Work Description E-Tender (2Nd Call) For Procurement Of Laboratory Instruments, Equipment, Appliances For The College Of Veterinary Sciences And Ah, Rk Nagar Under The Nec Funded Project For The Year 2025-2026 , Biosafety Cabinetclassii, A 2 With Accessories And Power Back Up (Bacteriology)--• The Biological Safety Cabinet Should Be Of Class Ii, Type A2 Designed In Compliance With International Standards • The Biological Safety Cabinet Quoted Instrument Model Must Have International Standards Test Likensf, Tuv Nord, En 12469 Certification. Certificate Copy Must Be Provided Along With The Technical Bid. • Working Area Should Be Around 4Foot. It Should Have Exterior Dimension W X H X D Of 1300X 1568 X 800 And Interior Dimension Wxhxdof 1200X 780X 630 • It Should Have 1 Piece Grade 304 Stainless Steel Or Thermos Scientific Smart Coat Interior • Itshouldhavefeatureforpersonalprotection,Sample Protection, Cross Contamination Protection And Environmental Protection. • It Must Utilize Brushless Dc Motor Technology Which Uses Significantly Less Energy With Less Heat Emission Provision Compared To Traditional Ac Motor Technology To Ensure Lower Levels Of Energy Consumption. • It Should Have 10° Sloped Front For Exceptional Comfort And Ergonomics • Thesystemshouldbedesignedwithdualmotor. • The Motor Must Automatically Adjust Or Control Fan Speed In Real Time To Maintain Constant Airflow During Filter Loading Or Temporary Obstruction. • Air Flow Direction: Vertical Laminar Flow & Air Intake Across Front Opening And 70% Recirculation. • Filter: High Performance Particle Air Filter H14(Hepa En1822), Filtering Efficiency 99.995% Mpps Or Better. • Energy Saving Mode When Cabinet Not In Use With Maintaining Sterility. Continuous Airflow Helps To Maintaina Sterile Environment, Evenwhen The Cabinet Is Not In Use. • Thesystemshouldhaveindependentsensorstodetect Pressure Changes Across The Exhaust And Down Flow Plenum/ Air Velocity And Should Indicate Alarm Signal When A 20-30% Change In Inflow/ Exhaust Or Down Flow Occurs. • Control Panel And Performance Monitor Displays Inflow/ Down Flow Velocities, Hours Of Use Etc. To Verify Proper Cabinet Operation. • Frontglasswindowshouldbeeasilyloweredforthorough Smart Cleaning Of Inner Surfaces And Designed To Protect Users By Maintaining Inflow, Even When The Window Is Lowered. • The Uv Light Must Be Quoted Which Should Be Programmable From 30 Min To 24 Hrs. In Minimum 30 Minutes Increment To Shut Off Automatically. The Settings Must Allow The User To Program The Timer. • The Cabinet Noise Level Must Be Less Than 63 Db(A) As Measured In A Sound Proof Room To • Promote More Comfortable And Safer Working Habitsof The User A Per Nsf/ Ansi 49. • The Controller Must Be Located On A Slanted Frontpanel So It Is Easy To See From A Seated Working Position In Front Of The Cabinet. • Control Panel Should Be A Large Digital Color Touch Screen Display With Health Monitoring System, Valuable Safety And Performance Data With Constant Read-Out Of Downflow/ Inflow Velocities And Hours Of Operation In Real-Time, Number Of Hours Of Use On The Hepa Filters. • The Front Window Sash Must Be Angled 10° Sloped Front For Operator Comfort. • Two Pieces Of Removable And Autoclavable Stainless Steel Arm Rest Should Be Provided For Operator’S Comfort Without Disturbing The Air Flow. • The System Must Have Audio Visual Alarms To Indicate When Inflow Is Restricted And As Well As Whether Front Window Is In Correct Position Or Not. • Theworkareashouldbeilluminatedwithswitchable Fluorescent Lamp Of Lighting Power >120 Fc Or Higher. • Suitable Height Floor Stand Without Casters Should Be Provided. • In Built Access Ports, 2 Nos. (1 On Each Side) Shouldbe Available. • It Has Single Piece Stainless Steel Work Tray For Easy Cleaning And Decontamination. • Warranty:Minimum3year. • Electrical Supply Available: 230V A.C, Single Phase, 50 Hz. • Bidder Should Provide Printed Brochure Of The Quoted Model And Details Specification Should Be Available In The Manufacture Website. • Customized Model Would Not Be Accepted Withoutany Quality Control Certificate Or 3Rd Party Approved Certification • Prompt & Efficient After Sales Service Should Be Available In The Eastern Region Of India. • User List: Minimum 10 Numbers Of Quoted Model Should Have Been Installed In Government • Institution(Listshouldbeenclosed). • Quotedwith2kvaservovoltagestabilizer. • Three(2)Yearswarranty. • 3Kva Stabilizer , Autoclave--• Capacity: 60L To 80 L, Vertical, Watt:3-4Kw, Operation Mode: Fully Automatic (Digital Controller With Automatic Pressure Release Valve), Construction: Double Walled Inner Chamberstainless Steel 304, External Chamber: Stainless Steel 304 Lid Stainless Steel 304, • Ring & Stand: Stainless Steel 304 Heater Immersion Heater, Gasket: High Temperature Silicone Rubber Gasket (Joint Less), Locking System Radial Locking Mechanism W/ Pedal Lifting Device/ Butterfly Nut Lid Lock. • Temperature Range: 121°C To 125°C Temperature Accuracy ±1°C • Temperaturesensor:Pt100 • Controller: • Digitaltemperaturecontroller • In-Builtdigitaltimer0-60Minutes • Endofsterilizationbuzzeralert • Digitaldisplayofpressure • Sensorbrokenindication • Pressure:15To20psior Above. • Steam Release: Automatic Steam Release After Sterilization • Releasevalve:Solenoidvalve • Pressuredisplay:Dialtypepressuregauge • Safety • Overpressuresafety Valve • Automaticvacuumbreaker • Lowwaterlevelcut-Off Sensor • Basket:Wiremeshbasket • Powersupply:220Volts50hz • Waterinletvalve • Directlypourintothe Chamber • Standardaccessories: • Waterlevelindicator(Glass) • Waterdrainvalve • Warranty:3Years(On-Site) , Bod Incubator-- • Capacity:200L • Temperaturerange:Ambient+5°Cto+60°C • Chamber:Stainlesssteel • Temperatureaccuracy:±0.5°C • No.Ofshelves:3-6 • Temperaturesensor:Pt-100 • Shelves:Perforatedstainlesssteel • Dimension:Lxwxh(Cm)-80X80x180 • Numberofdoors:1-2 • Loadperrack(Kg): 25-60 • Lighting:Interiorilluminationwithledlight. • Insidedoor:Transparentacrylic • Outsidedoor:Well Insulated • Power:Workson230vacsinglephase50hz • Displaydigitaldisplay • Warranty:3Years(On-Site) , Video Endoscopy Machine-- • Should Be Veterinary Specific & Suitable For Companion Animal As Well As Large Animal. • Gastroscopeshouldhaveintegratedvideocamera With High Source. • Shouldalsohavemedical Colonoscope. • Insertion Tube Should Be Of Extremely Short Tip With Outer Diameter Of 8.4 Mm, Working Length Should1050 Mm, Working Channel Should Be 2.8 Mm. • Should Have 4- Way Deflection (Upward 210°, Downward 90°, Left 100° And Right 100°). • Fieldofviewshouldbe120°. • Depthofviewshouldbe3-100Mm. • Should Be Provided Along With Carrying Case, Caps For Working Channel, Irrigation Tube, Cleaningbrush And Cleaning Valve. • Shouldhavebiopsyforcepsandforeignbody Forceps. • Hd Camera System Should Be Compatible With Both Flexible And Rigid Endoscope. • Should Have Internal Medical Grade Recorder For Capturing Full Hd. • Patients Informationshouldbe Editable Anddisplayed In Monitor. • Shouldbesuppliedwithmedicalgrademonitor. • Shouldbesuppliedwithtrolley. • Patients Informationshouldbe Editable Anddisplayed In Monitor. • Shouldbesuppliedwithmedicalgrademonitor. • Shouldbesuppliedwithtrolley. • Shouldprovide3-Yearwarrantyandshouldhave Oemserviceengineerpostedattripuraforregular Promptservice(Documentstobe Enclosed) , Elisareader Withaccessories Including (Absorbance Microplate Readers, Software And A Fully-Automated Elisa Processor And Powerbackup.)-- • Filter Based Elisareader With Halogen Lamp As Light Source And Single Channel Optics/ Single Detector With Silicon Photo Detectors For Reliable Results. • Halogenlampshouldhaveminimumusageoption, I.E. It’S Should Get ‘On’ While Reading And Should Be ‘Off’Mode Even The Instrument Is On Standby Mode. • Should Be Compatible To Wavelength Range From 340 To 850 Nm, Which Must For Various Elisa Applications. • Shouldhaveeasyaccess8positionfilterwheel. • Instrument Should Be Supplied With 3 Standard Filters Of 405Nm, 450Nm And 620Nm. • Should Have Automatic Calibration And Selfdiagnostics Of Any Possible Error In Optical Alignment Before Each Program Reading. • Should Able To Read 96 Well Format Microwell Plate In 6 Seconds. • The Instrument Should Run In Stand-Alone Mode Orwithcomputer&Dataanalysissoftware Controlled. • Internal Software (Standalone Mode) Should Have All The Basic Application Related To Elisa Like Quality Control, Qualitative Classification, Standard Graph Etc. • Computer Software Should Be Supplied With Unlimited User Licenses And Should Have Reading As Well As Data Analysis Option Including Standardcurve Fit, Qualitative Classifications, Quality Controletc. • Systemshouldabletoruninstand-Alonemodeusing 4.5-Inchcolourdisplayand Keypad. • The Instrument Should Have A Memory Of 99 Inbuilt Protocolsinstand-Alonemodeand100resultmemory. • The Instrument Should Have 2 Usb Ports, One For The Easy Data Transfer And Another To Connect Printer Directly To The Unit. • System Should Have Usb Port For External Printer Connectivity Option For The Data Printout. • Instrument Should Be Either Ce Mark/ Ivd/ Usfda, Authorized Certificate From Notified Body Should Be Submitted. • One(1)Year Warranty O 3Kvaonlineups O Attached With Suitable Computer Desktop With Powerbackupwithfollowingconfigurationintel I3processor12th Gen, 8Gb Ram, Ssd, Ddr-4, Hard Disk 1 Tb, 15 Monitor, Keyboard, Mouse With Computer Ups Dataanalysissoftware: O Software Should Have Option For Area Selection. I. E Differentprotocolsatdifferentareaofthesameplate. O Database Based Software To Run Backups Of All Data, Restore Back Up Data (In Case Of Hardware Failure Of Original Computer). O Singlesoftwareprogramshouldallowanynumberof Measurement Steps Within The Program. O Datashouldbeabletoexportinformatssuchas Excel,Pdf,Xml,Ornote. , Incubator (Bacteriological)-- • Controller: Microprocessor Pid Digital Controller For Temperature Control • Timer:99Hr59minorcontinuousselectable • Innermaterial:Stainlesssteel304 • Outer Material: Mild Steel With Antibacterial Powder Coated Paint • Door:Glasswindowviewingmetaldoublewalled Door • Insulation: Double Wall Construction & Mineral Wool Insulation To Avoid Heat Loss • Innerdimensions:455X455x610mm(Wxdxh) • Capacity:6Cu.Ft(Table-Topmodel) • Temperaturerange:Ambient+5°Cto100°C • Temperature Accuracy:±1°Ccontrolledwithpt-100 Sensor • Temperatureuniformity:±1°C • Heaterload:600Wheaterresistancenichromewire • Aircirculationfan:Maintainuniformtemperature • Display:Leddigitaldisplay • Shelves (Removable): Ss 304 Made 03Nos. Wire Mesh Shelves • Safety:Over/Undertemperaturealarm&Cut-Off, Over Current Breaker • Electricsupply:220V,50Hz;With3-Pinsafetyplug And Power Cord • Warranty:3Yrs , Micro Haematocrit Centrifuge-- • Motorcapacity:24X75mmlengthcapillarytubes. • Speedrangeof500-12,000Rpm,Max.Rcf12000/ 14118G. • Independentcontrolofspeedandtime. • Easyoperationwithintuitivemenuanddigitaldisplay. • Max.Speedof 12,000Rpm. • Rotor:Hctrotorwithscrewonlid. • Weight:4-8Kg • Warranty:2Years(On-Site) , Micropipetteset--• Kitshouldinclude0.2-2,2-20,20-200&100-1000Ul Single Channel Pipettes, 1Pipette Stand (6 Position), 4 Sizes Tip Boxes With Tips, Reagent Reservoir Sample, Calibration Certificate. • Alsoincludedextratwopipettes1-10Ul,10-100Ul. • Fullyautoclavable • Advancedvolumegearingmechanism • Shouldhavelarge,Easy-To-Readdisplay • Double-Action Pipetting Button With A Rotating Upper Part, For Easy And Light Volume Setting. • Shouldbelightweight,Leastrsi(Repetitivestrain Injury) • Ergonomicdesign,Separatesofttouchtipejector • Inlabcalibrationandeasymaintenance,Easytoopen • Superblowoutpistonforsmallvolumestoensure Delivery Of Micro Size Drops • Shouldbeisoandusfdacertified(Provide Document) • 2Years Warranty , Desktop Computer-- • Operatingsystem:Windows11pro(Original) • Processor:Intel®Core™I5-13500 (Upto3.8Ghz With25mbcacheand6 Cores) • Memory:8Gbddr4-3200Mhzram • Storage:1Tbhdd+512Gbssd • Graphics:Intel®Uhdgraphics770 • Chipset:Intel® • Connectivityandcommunications:Intel®Wi-Fi6e And Bluetooth® 5.3 Wireless Card • Ports: 1 Headphone/ Microphone Combo; 1 Usb Type- C 10Gbps Signalling Rate; 3 Usb Type-A • 10Gbpssignallingrate • Videoconnectors:1-Hdmi1.4;1-Displayport1.4; 1- Vga • Monitor:Size-60.5Cm,Fhd(1080P)Withips Display • Pointingdevice:Wiredmouse • Keyboard:Wired • Should Include Original Preinstalled Latest Version Microsoft Office Home, & Student 2021 Lifetime Subscription • Ups:1,000Va,360W,Withleast15-Minuteback-Up • Warranty:03Years(On-Site). , Scalding Tank (Stainlesssteel)-- • Material: Stainless Steel: 304Ssgrade- Cylindricalshapedwith Legs-Drum1.2 Mm Thickness With Lid. • Drumcapacity–50–60Litres • Capacity–2-3Birds • Electricalheater–2Kwcapacity • Power:230-240V/50Hz. • Controlpanelwithdigitaltemperatureindicators.Type: Electrically Operated , Clinical Haematologyanalyser(Five Part)--• Fullyautomatic Veterinary Hematologyanalyzer For Analysis Of Different Species Of Domestic, Pet Animals, Lab Animals And Wild Animals’ Blood. • Flow Cytometry (Fcm), Tri-Angle Laser Scatter, Chemical Dye Method And Independent Basophilchannel Etc./ And Other Advance Method • 5 Parts For Different Wbc Count With Veterinary Animal Species Specific Software • Minimum23parameters:Wbc,Lym%,Mon%,Neu %, Eos%, Bas%, Lym#, Mon#, Neu#, Eos#, Bas#, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct. • 3Histogramforrbc,Wbc&Plt • 3Scattergramsforwbcdifferential • Samplevolume<20?L,Tfttouchscreendisplay • Canprocess Upto60samplesperhour • Storageupto30,000Samplereport. • Keyboard,Externalinkjetprinter,Supportedbyuser- Defined Report Format Print Out (A4 Size) • Fullsetconsumablereagentsuppliedalongwith Instrument. • Onlineups1kva,360Wwith15-30Minbackup • Shouldprovide3yearswarrantyandshouldhaveoem Serviceengineerpostedattripuraforregularand Prompt Service (Documents To Be Submitted Along With Enit) , Electric Stunner--• Stunner With Ss Tongs To Operate On Sheep/ Goats And Pigs. • Thecontrolboxwithanaloguedisplayfor0–110 Voltsand2ampere. • Withdigitaltimer. • Stunnerwithcontrolbox. , Portablecolouranalyser-- • Digitalcolourmeterthatmeasurescolourinlab • Colourspace:Cielab • Colourdifferenceformula:?E*Ab • Measurementcaliber:F8mm • Lightsource:D65 • Sensor:Photodiodearray • Observer:Cie10°Standardobserver • Measurementrange:L:0To100 • Repeatedaccuracy:?E<0.1 • Tabledifference:?E<0.2 • Measurementinterval:1Sec. • Storage Capacity: Type Sample Data: 100 Groups With Testing Sample Data: 100 Groups • Lifetimeofbulb:Minimum5years. • Displayscreen:Tfttruecolour 2.8Inch@(16:9) • Language:English , Mufflefurnace--• Temperaturerangesupto1000oc,Workingtemperature Upto950oc,Size19x16x18(L X W X H)Inches, 220/ 230-Volt, Warranty: 02 Year (On-Site) , Mixer Grinder--• No Of Jars: 3; Jar Size: Wet Jar (1.5 Litres), Multipurposejar(1Litre),Chutneyjar(0.3Litres);Jar Material: Stainless Steel; Body Material: Abs; Blade Material: Stainless Steel; Speed Control: 3 Speed Control+Pulse,Wattage:1000W;Voltage:230V, Warranty:01Year(On-Site) , Labwilly Mill--• Bodymaterial.Ms,Powersource.Electric,Voltage- 240V,Frequency-50Hz,Powerconsumption-0.75 Kw,Load.43Kg. , Digital Camera--• 24.1-Megapixelaps-Ccmossensor&Digic4+ Image Processor • 9-Pointafwith1centrecross-Typeafpointand Standard Iso 100 - 6400 (Expandable To 12 800) • Displaysize:3Inch • Lenstype:Opticalzoom • Digitalcameralensef-S18-55Mmf/3.5-5.6Isii , Exhibition Panel/Panel Board With Stand--• Size:10X4feet • Usage/Applicationexhibition • Size10x4feet • Framematerialaluminum • Mountingfreestanding • Shaperectangular • Thickness2.5-10Mm , Rms Speakers-- • 100Watts,Sta-150,Withtripodstandofheight Adjustment: 3.5Ft-6.5 Ft, • Loadcapacity;40Kg, • Warranty:1Years , Wireless Microphone-- Audiooutput:0110Mv/600,Freq.Resp:50-15000Hz, Antenna: Detachable Through Bnc Connector, Power: Ac-220-240Foracadopter,Modulationmade: Fm(F3e), Warranty: 1 Years. , Amplifier-- Ac&24Vdcoperated,250Watts,6Mic&2Aux, Warranty: 1 Year. , Publicaddress With Speaker--Pasystemwithabuilt-Inamplifier,Bluetooth,Usb, Recording,Andecho.Elegant,Rugged&Easytocarry Amplifier Which Delivers 20W (Max.) Output Power. Built-Indigitalmp3playerwithrecordingandbluetooth Function. Built-In Digital Echo. , Interactive Board--Size-75With4kultrahighdefinition(3840X2160) @ 60Hz With Oled Display Technology With 8 Ms Response Time, 20 Points Ir Multi Touch Interface, 3 Hdmi, 4 Usb, Bare Dimension Of 1990 X 114 X 1201 Mm With <320W Power Consumption, Build In Android 8.0 With < 3 Gb Ram And < 32 Gb Rom With Ops<I5 Ori78gbramand1tbssd,Builtinwi-Fi,Warranty Period: -3Yearsfromthedateofinstallation. , Video Camera (Hd)-- Sensorsize:23.5Mmx15.7Mm,Imagesensortype: Cmos, Total Pixels 21.51 Million, Dust-Reduction Systemimage Dust Off Reference Data (Nx Studio Software Required)Effective Pixels (Megapixels) 20.9 Million,Imagesensorformat,Aps-Csize/Dx-Format, Filesystem Dcf2.0, Exif 2.31,Cardslot, Singleslot, Focus Point 209, Flash Compensation -3 To +1 Ev In Steps Of 1/ 3 Ev Available In Modes P, S,A, And M, Monitorsize7.5-Cm(3.0–In.)Diagonal,Monitor Resolution: Approx. 1040 K-Dot. , Antibiotic Zone Reader--• Accuratereadingofthezoneinmmondigital Display • Resolution: 0.1 Mm. Electronic Zero Adjustment Eliminate Tedious Zero Setting On The Scale. No Parallax So No Human Error In Reading. Fine Focus Adjustmentfor Clear Image On Viewing Glass. No Effect Of Ambient Light On Image. Halogen Lamp For Sharp And Bright Optical Imaging And Also Should Have Long Life. User Friendly Design To Operate The Instrument. Range: 0 To 80.0Mm.Leastcount0.1Mm. • Display:3-Digit7segmentred Led. • Powersupply:230V,50Hzac. • Dimension: 370 W X 380 D X 220 Mm H. Weight: 8 Kg Approx. • Warranty:1Years , Eddy’Shot Plate--• Hot Plate Analgesiometer (Eddy’S Hot Plate) Is Developed To Perform Rapid & Precise Screening Of Analgesic Drug Properties On Small Laboratory Animals. • Plate Temperature Can Be Held At Set Point Between 5? Above Ambient To 60? (± 2?). • Resolutionofreactiontime:0.1Second,Cutoffthe Timertoavoiddamagetotheanimal. • Top Lid Sensor To Indicate Lid Is Open And Thereof Avoiding Temperature Fluctuations. • Pcconnectivitywithsoftware. • Software Has Provision To Add Titles, Comments, Graphical Presentations And Data Can Be Converted Into Excel Or Pdf. • Mustbesuppliedwithpcwithaccessories& Software. • Withfreeinstallation&Commissioning. • Warranty:1Years(On-Site) , Digital Plethysmometer--• Digital Plethysmometer Is A Micro Controlled Volume Meter, Designed For Accurate Measurement Of The Rat/ Mouse Paw Swelling And Used For Evaluation Of Ant- Inflammatory And Anti-Oedema Properties Of Pharmacological Substances. The Water Displacement Produced By The Immersion Of The Animal Paw In The Measuring Tube Is Reflected Into The Second Tube, Inducing A Change In The Conductance Between The Two Platinum Electrodes. The Plethysmometer Control Unit Detects The Conductance Changes And Generates An Output Signal To The Digital Display Indicating The Volume Displacement Measured (0.01 Ml Resolution). The Current Value Remains In The Digital Display Until A Newtrialstarts.Thecontrolunit Canbezeroedbetween Successive Readings By Pressing The Zero Button. • Keyfeatures: O Animalstobetested:Mouse&Rat O Resolution:0.01Ml O Digital Display With Easy Pedal Switch Control, Evaluation Of Small Volume Differences, Comfortable Readingonlcdgraphicdisplay,Connectivitytopc Andmustbesuppliedwithpcwithrequired Software, Must Include Free Installation & Commissioning. Warranty: 1 Years (On-Site) , Electric Dehorner-- • Material:Stainlesssteel • Automationgrade:Automatic • Producttype:Electricandstainlesssteel • Capacity:50Hz • Warranty:2Years(On-Site) , Community Nest Box-- • Apoultryhousingmodelfordemonstrationtostudents. • Productdimensions:45.6Lx13Wx26H • Material:Alloysteel , Feedgrinder (Mini)(For Poultry/Cattle Feed)-- • Grindermachine(Forpoultry/Cattlefeed): • Motor: 2 Hp, Capacity – 200-300 Kg/ Hour, Material – Mildsteel,Inputvoltage–220V,Phase–Single,Sieve – 3 Mm Holes (2 No), Additional Spares – Sieve: 2.5 Mm Hole – 1 No & 4 Mm Hole Sieve – 1 No, Beaters: 1 Set, Grinder Fixed On Rot Iron Angle. • Withfreeinstallation,Fittingfixing&Commissioning. • Warranty:2Years(On-Site). , Feedmixer (Mini) (Forpoultry/ Cattle Feed)-- • Mixerforpoultry/Cattlefeed: • Horizontal Mixer, Motor: 2Hp, Mixingvolume 70-100 Kg/Batch,Mixingtime–8-10Minute/Batch,Single Phase,Mixerfixedonrotmmmironangle,Material: Ms. • Withfreeinstallation,Fittingfixing&Commissioning. • Warranty:2Years(On-Site). , Physiograph--Student Physiograph Recorder Is A Highly Sensitivity Oscillograph Mainly Being Used For Teaching Experiment Physiology And Pharmacology. Digitalstudentphysiographfeatures • Standalone Unit Having Coloured Tft Display For Displaying Online And Offline Recording Data. • Digitalphysiographwithtimeandeventchannel. • Compact, Lightweight And Easy To Operate By Abeginner. • System Has 6 Couplers Fitted In A Single Unit Making It Easy To Carry. • System Has 8 Transducers (Force, Pressure, Volume, Respiration, Temperature, Pulse, Respiration Belt And Isotonic) • Interface To The Computer-Through Usb • System Is Supplied With Pc & Software To Review And Print The Recorded Data From Pc. Studentphysiographcomprises Ofcouplersto Record Different Parameters The Standard Range Ofcouplers Are As Follows A) Biopotential Coupler: Bio-Potential Coupler Is Designed To Record Almost All Kinds Of Ac Phenomena Like Ecg, Eeg, Emg, Erg Or Any Other A.C. Phenomenon. Isotonic Coupler: For Recording With Isotonic Fine Movement Transducer. Strain Gage Coupler: Coupler For Recording From All Strain Gage Transducers &Use To Record Muscle Activity Force, Effect Of Drug On Heart Activity Etc Pulse-Respiration Couplers: For Recording Pulse Or Respiration Using Photo-Electric Transducers. Temperature Coupler: For Recording Internal Or Surface Temperature Through Orchid Temperature Transducers: Atransducerisadevicewhichconvertsoneformof Physical Energy To Electrical Energy Or Vice Versa. • Warranty:2Years(On-Site). • Mustincludefreeinstallation&Commissioning. , Milkingmachine--• Noofbuckets:1.0 • Productivity:1-10Cows/Hour • Capacity:25Litre • Automationgrade:Semi-Automatic • Powerinput(W):110W • Voltage(V):110-220V • Frequency(Hz):50/60 Hz • Warranty:4Years(On-Site) • Mustincludefreeinstallation&Commissioning. , Demonstration Modelofcow-- • Naturalsize,Detachableskintoshowsuperficialand Deep Muscle. • Headandneckdetachableanddissectible. • Visceraearedissectibletodemonstratevarioussystems Within The Organ Are Also Detachable. • Detachablehoof , Captivebolt Pistol--• Non-Penetrativeconcussionstunner • Universalinapplicationfromlargebullstosmalllambs, With Varying Power Load Strengths • Wellbalanced,Comfortableergonomicallydesigned Handle • Automaticboltreturn • Legalpermissionrequired • Standardtoolin0.22Or0.25Calibre. • Robustsolidconstruction. • Features/Specifications: • Chromesteel Finish • Knurledhandleforbettergrip • Fewerpartsthancompetitivebrands • Boltpenetrates2.25
Basic Detail
Tender No 4-46/CVS/STORE/INST/RKN/23-24
Bidding Type Tender
Location
City Tripura
State Tripura
Key Dates
Publish Date 16 Jul 2025
Submission Date 24 Jul 2025
Open Date 25 Jul 2025
Finance
Tender Value 77 Lakhs
Tender Fee 2500
EMD 1.55 Lakhs
Exemption Available
Document List
e9640139-e343-4e34-85f2-9185bd8f382c.html
BOQ_64218.xls
DNIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 24, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 24, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 25, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

e9640139-e343-4e34-85f2-9185bd8f382c.html

xls

BOQ_64218.xls

pdf

DNIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender