Tender For Electrification Of All Awc Within Chilakhana-Ii Gram Panchayat Under Tufanganj-I Dev. Block, Coochbehar-West Bengal

Zilla Parishad has published Tender For Electrification Of All Awc Within Chilakhana-Ii Gram Panchayat Under Tufanganj-I Dev. Block. Submission Date for this Tender is 01-07-2025. Electrification Work Tenders in Coochbehar West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

49863778
Tender For Electrification Of All Awc Within Chilakhana-Ii Gram Panchayat Under Tufanganj-I Dev. Block
Tender
Indian
West Bengal
Coochbehar
01-07-2025

Tender Documents

Tender Details

Tender For Electrification Of All awc Within Chilakhana-Ii Gram Panchayat Under Tufanganj-I Dev. Block - 1 Supply and Fixing of fuse unit complete with base and bridge on existing Board and necessary connection, for the following range.b) 32 Amp., 240 V (Electrical-Mechanical Works (Volume-1)page no-17 Serial Number 24 U.D.M.A.D) 2 (Schedule of Rates For Electrical Works Volume - I Serial Number D-1, 1.a PWD) Supplying and fixing Sheet steel Main Switches on angle iron frame on wall (Havells/standered) 30/32 Amp 240V DP with fuse on L&N 3 (Schedule of Rates For Electrical Works Volume - I Serial Number D-9 , 13 PWD) Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+4 way 4 (Schedule of Rates For Electrical Works Volume - I Serial Number D-6, 7 PWD) Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 40 amp. 5 (Schedule of Rates For Electrical Works Volume - I Serial Number D-6, 7 PWD)Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6 Supply & Fixing of 9 Watt LED Lamp . (havells/Phillips/Standard) 7 Supply of Ready to use retrofit LED Tube Set existing FTL T12 luminaire by removing1x18W FTL T5 (Havells/Phillips) 8 (Schedule of Rates For Electrical Works Volume - I Serial Number C-2 , 14.a PWD)Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc. 9 Supply and delivery of Ceilling fan 48” Sweep b) Orient Make(Electrical-Mechanical Works (Volume-1) Serial Number 70 U.D.M.A.D) 10 (Schedule of Rates For Electrical Works Volume - I Serial Number D-14, 29 PWD) Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) 11 (Schedule of Rates For Electrical Works Volume - I Serial NumberC-3, 21.a PWD)Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw aftermaking housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. 12 (Schedule of Rates For Electrical Works Volume - I Serial NumberC-3, 21.a PWD)Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. 13 (Schedule of Rates For Electrical Works Volume - I Serial Number D-13, 27 PWD) Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] 14 (Schedule of Rates For Electrical Works Volume - I Serial Number D-12, 6 PWD) Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with bakelite/perspex (wall matching color) top cover of 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] on board 15 (Schedule of Rates For Electrical Works Volume - I Serial Number D-11, 1 PWD) Wiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC 16 (Schedule of Rates For Electrical Works Volume - I Serial Number E-6, 22 PWD) Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 17 (Schedule of Rates For Electrical Works Volume - I Serial Number G-1 , 2.a PWD) Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe 18 GST @ 18% of Total 19 Cess @ 1% of Above All

Key Value

Document Fees
INR 1000 /-
EMD
INR 6072.0 /-
Tender Value
INR 3.03 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail