Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-06-2025 | Revised BOQ | BOQ | 14-07-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 2 | M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles including and over screed bed or bedding layer 20mm thick in cement mortar 1:6 complete all as specified and directed. |
| 3 | M&L for glazed ceramic coloured tiles of size 350mm x 250mm x 7 mm/450/350/7mm thick thick on vertical surfaces set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade oftiles including and over Rendering 10 mm thick cement mortar 1:3 on fair faces of brick work or concrete surfaces, including finishing the surfaces even andfair to receive the wall tiles etc complete all as specified and directed. |
| 4 | S&Fin repair galvanised steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm including necessary beadings, cleats and fillets including dismantling complete all as specified and directed. |
| 5 | S&F in repar4mm thick sheet glass ordinary quality, in square or reqd shape n.exc 0.50 Sqm in each pane including dismantling complete all as specified and directed. |
| 6 | S&F in repair figured glass pin headed type in square n exc 0.50 Sqm, in square or reqd shape of 4mm thick in each pane including oil putty complete all as specified and directed. |
| 7 | S&F in repair 150mm long alumnium barrel tower bolt, stove enamelled black with bright bolt complete all as specified and directed. |
| 8 | S&F in repair 200mm long aluminium barrel tower bolt, stove enamelled black with bright bolt complete all as specified and directed. |
| 9 | S&F in repair 150mm long mild steel pressed handle, oval type stove enamelled black complete all as specified and directed. |
| 10 | S&F in repair aluminium Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and directed. |
| 11 | S&F in repair 25mm dia Curtain rod, mild steel, chromium plated with fixing brackets,stops, rollers etc, complete all as specified and directed. |
| 12 | S&F in repair 250mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed. |
| 13 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 14 | S & F for powder coated GI Snap grid system of size 605 X 605 mm for ceiling fixed to walls with rawl plugs and screws and hang to roof members with 2 mm dia GI wire comprising of the following sections complete all as specified and directed:- (i) Main Tee 28mmx24mmx0.3mm thick, (ii) Cross Tee 28mmx24mmx0.3mm thick and (iii) Wall angle 24mmx24mmx0.3mm thick complete all as specified and directed. |
| 15 | S & F for 4 mm thickin repairs designer ceiling (E-board classic tiles) for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or GI sanp grid or with staples on snap grid as in ceilingwith and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed. |
| 16 | Dismantaling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 17 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed. |
| 18 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed. |
| 19 | Repair/ resecuring of aluminium doors, easing & adjusting including replacement damage part and assoceries if required including taking down and refixing in same opening etc complete all as specified and directed. |
| 20 | S&F in repair 15 mm borebib tap,cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 21 | S&F in repair \"flushing cistern kit\" for complete set to fitted inside asreqd for cistern functional complete all as specified and directed. |
| 22 | S&F in repair15 mm bore bib tap, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 23 | S&F in repair 15 mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 24 | S&F in repair 15 mm bore Stop valves, fancy type chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 25 | S&F in repair 15 mm bore Pillar taps, cast copper alloy,fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 26 | S&F in repair 15 mm Brass CP wall Mixer with hand shower swan neck , cast copper alooy with capstan head chromium plated screwed down, high pressure with or without lettered hot or cold mix with long screwed shank and fly nuts screwed down for iron pipe and fixed complete all as specified and directed. |
| 27 | S&F in repair 15 mm Brass CP Wash Hand Basin mixer with , cast copper alooy with capstan head chromium plated screwed down, high pressure with or without lettered hot or cold mix with long screwed shank and fly nuts screwed down for iron pipe and fixed complete all as specified and directed. |
| 28 | M&L for 32mm waste fittings, brass, chromium plated for wash hand basins etc with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed complete all as specified and directed. |
| 29 | All as per item No.28here- in- before but 50 mm dia for sink coupling. |
| 30 | S&F in repairCP Grating doom 125 mm dia(minimum wt 40grms) complete all as specified and directed. |
| 31 | S&F in repair 15mm PTMT Bib tap standard of any colour screwed, for iron pipe and fixed complete all as specified and directed. |
| 32 | S&F in repair 15mm Ball valves, high pressures of PTMT, withepoxy coated aluminium rod & high-density plastic ball screwed for iron pipe, Minimum wt (15mm -142gms) complete all as specified and directed. |
| 33 | All as per item No.32here- in- before but size 20mm dia and Minimum wt (for 20mm -210gms) |
| 34 | S&F in repair, water tank cover for tanks of size 500 ltr or 1000 ltrs water storage tank complete all as specified and directed. |
| 35 | S&F in repair PVCseat cover forEWC of white colour complete all as specified and directed. |
| 36 | S&F in repairHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 37 | Taking up or down steel tubing 15mm and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 38 | Taking up or down steel tubing 20 mm and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 39 | S&F in repair15mm bore steel water tubing medium grade galvanized with all fittings for fixed to walls, floors, roof ceiling etc including thread, soluvent and etc complete all as specified and directed. |
| 40 | S&F in repair, 20mm bore steel water tubing medium grade galvanized with all fittings for fixed to walls, floors, roof ceiling etc including thread, soluvent and etc complete all as specified and directed. |
| 41 | S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 42 | All as per item No. 41here- in- before but 600mm long. |
| 43 | Disconnecting existing tanks, exc. 250 Ltr but not exc 500 ltr, Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 44 | Disconnecting existing tanks, exc. 500 ltr but not exc 1000 ltr, Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 45 | S & F for 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoistedand fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 46 | S & F for 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoistedand fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 47 | M & L for preparation of old decorated plastered surfaces of walls and applying one coat of white wash complete all as specified and directed. |
| 48 | M & L for Preparation of old decorated plastered surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of distemper oil emulsion complete all as specified and directed. |
| 49 | M & L for Preparation of old painted wooden surface of any descriptionover10 cms widths or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 50 | M & L for Preparation of old painted steel surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 51 | M & L for Preparation of old painted steel surfaces of water tanks of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.Note: Rate for Staging of water tanks for painting up to 6 Mtr height is deemed to be included in quoted rate of this item. |
| 52 | S&F in repair 32mm dia PVC waste pipe for wash basin and kitchen sink complete all as specified and directed. |
| 53 | S&F in repair 40mm dia PVC waste pipe for wash basin and kitchen sink complete all as specified and directed. |
| 54 | S&F in repair, 500 ltr capacity rotational mounded polythylene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position including disconnecting unserviceable PVC/Cement water storage tank of 500 Ltr capacity complete all as specified and directed. |
| 55 | S&F in repair 1000 ltr capacity rotational mounded polythylene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position including disconnecting unserviceable PVC/Cement water storage tank of 1000 Ltr capacity complete all as specified and directed. |
| 56 | S&F in repairbutt hinges med weight cold rolled MS, size 100 mm long complete all as specified and directed. |
| 57 | All as above item No 56 but 75 mm here-in-before. |
| 58 | Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed. |
| 59 | M & L for 15 mm thick renderingof brick work or stone masonry surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 60 | M&L rendering 15mm thick on fair faces of brick or concrete surfaces with cement mortar 1:6 finished even and smooth with out using extra cement complete all as specified and directed. (Note : Execute in patch work also.) |
| 61 | M&L for preparation of new plastered surfaces and applying two coats of Oil Bound Distemper over a coat of primer complete all as specified and directed. |
| 62 | M&L for preparation of new plstered surfaces of walls and applying two coat of cement base paintover acoat of primer complete all as specified and directed. |
| 63 | Taking down Chowkhats or framesnot exc 1.5 Sqm each(without taking off shutters from the frames) complete all as specified and directed. |
| 64 | Taking downchowkats & shutters without taking offshutters from the frame, size of openingexc. 1.50 sqm but not exc 4 sqmeach complete all as specified and directed. |
| 65 | M&L for Solid PVC door frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification and drawing complete all as specified and directed. |
| 66 | S&F for factory made solid panel PVC door shutter 30mm thick (stile), consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification and drg complete all as specified and directed. |
| 67 | S&F in repair 10 Ltr capacityPVC valveless, syphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets complete all as specified and directed. |
| 68 | Demolition of Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 69 | M&L for Hardcore of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface etc complete all as specified and directed. |
| 70 | M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate, 100 mm thick as in floor etc complete all as specified and directed. |
| 71 | M&L for Machine pressed precast concrete interlocking paver blockwith grey colour any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade as in floor over 25 mm thick sand cushioningcomplete all as specified and directed. (Sand cushioning shall be measured and paid seperately) |
| 72 | M&L for Sand filling under floors or in foundations including watering and consolidation to match complete all as specified and directed. |
| 73 | Removing excavated material to a distance n exc. 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 74 | Demolition of brick work built in cement mortar complete all as specified and directed. |
| 75 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 using old size bricks as in manholes, etc complete all as specified and directed. |
| 76 | M&L for Plain Cement Concrete 1:2:4 type B-1 (using 20 mm graded granite stone aggregate) as in cills, benching and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and directed. |
| 77 | S&F in repair vitreous china squatting pan of orissa pattern long pan size 580 mm x 440mmwhite including flushing pipe etc complete all as specified and directed. |
| 78 | S&F in repair Vitreous China wash down water closet pan (Pedestal Pattern), white including white plastic seat cover with mild steel CP hinging device, suitable brass CP wash jet, flush pipe fixed as in repair complete jointing, connecting and making good the disturbed surfaces complete all as specified and directed. |
| 79 | S& F for Grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40gms) complete all as specified and directed. |
| 80 | M & L in repair vitreous chhinaware one piece EWC of size 620x350x725mm including seat cover of make PARRYWARE (EDEN) or equivalent in Cera / Hindware / Jaquar complete all as specified and directed. |
| 81 | S&F in repair 15 mm Brass CP sinkmixer with, cast copper alooy with capstan head chromium plated screwed down, high pressure with or without lettered hot or cold mix with long screwed shank and fly nuts screwed down for iron pipe and fixed complete all as specified and directed. |
| 82 | Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed. |
| 83 | M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 84 | M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed. |
| 85 | M/L for machine pressed precast conctete interlocking paver block of any shape and size conforming to IS-15658-2006 of 80mm thickness M-40 grade fixed with grey cement and no pigment complete all as specified and directed. |
| 86 | M&L for high strength epoxy concrete (FOSROC - Expocrete EC) filling for area prepared, epoxy concrete prepared by cutting manualy or mechanically/cleaning/drying by blower, epoxy conctrete prepared by mixing of mixing of prepacked Expocrete EC having base (B), hardner (H), fine filler (FF) with 6-10 mm graded stone aggregate (CA) at site in the specified proportion by weight (B:H : FF : CA- 4.537 : 2.145 : 20.818 : 30) as per manufacturer\"s instructions . The epoxy concrete shall be appliedto prepared and primed surface within 30 minutes ofmixing, finished with a steel trowel to fair and even surface complete all as specified and directed. |
| 87 | Preparation of old treated horizantal concrete or bituminous roads, pavements surfaces exceedings 10 cm in width or girth with wire brushes etc and painting lines, dashes, strips, circles and other marking with one coat of water thinable/ matt finished road marking paint white / orange/ yellow / black or any other colour as approved by GE complete all as specified and directed.Make : Apcotrack manufactured by Asian paints/ Guide line of Berger or equivalent make as approved by GE.Note: Runway paint to be carried out on the same surface at a interval of 03 to 04 month/ as and when required by user. |
| 88 | M&L for painting lines, dashes, arrow, letters etc on roads, pavements and the like exc 10 cm wide road marking paint ,aqua based white or golden yellow including preparation of old painted surfaces by rubbing andwashing complete all as specidfied and directed. |
| 89 | M&L for racking of joints/ removing old sealing compound, dirt etc from Dummy /Construction of 10mm wide and 28 mm deep, cleaning the joints sides properly by mechanical means with diamond cutter, filling the joint with closed cell, medium density, cross linked polyethene foam back up rod of 12mm dia and applying bond breaker tape on top of backup rod for complete width of the joints, priming top with specified primer suitable for polyurethene sealing compound and filling polyurethene sealent including using marking tape on edges of joints to avoid accidental spillage of sealant on top of surface of pavements complete all as specified and directed. |
| 90 | M & L for racking of joint/removing old any sealing compound, dirt from Expansion joint 20mm wide and 40 mm deep cleaning the joint sides properly by mechanical means with diamond cutter, filling the joint with closed cell ,medium density cross linked polyethene foam backup rod of 25 mm dia and applying bond breaker tape on top of backup rod for complete width of the joints priming top with specified primer suitable for polyurathene sealing compound and filling polyurathene sealentincluding using marking tape on edges of joints to avoid accidental spillage of sealent on top of surface of pavements complete all as specified and directed. |
| 91 | De-watering of septic tanks and soakage wells by manually or with pumping set and draining out the same out of cantt area complete all as specified and directed. |
| 92 | Taking out sludge from septic tanks incl inlet and outlet chambers, removing and depositing the sludge in a pit at a distance of minimum 50m from nearby living accn and covering the sludge in the pit with earth and finally spraying unslaked lime, dry, around the septic tank and over the pit complete all as specified and directed. (Cost of earth work in the pit is deemed to be included in the unit rate quoted by the tenderer. |
| 93 | Cleaning of blocked drain pipes (SGSW/humepipe) up to 100/150 /200mm bore by rodding from manholes and well flushing with water after cleaning the same all as required including disposing off the deposited sludge, etc inside pipes to a distance exc 50m & n.exc200 m, burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.20 kg / Sqm and dressing of surplus soil around slope complete all as specified and directed. |
| 94 | Cleaning of manholes including taking out accumulated semi liquid, sludge and other deposits such as broken bricks , silt etc from manholes of depth n.exc 1.5 m, cleaning as directed and removing the same to a distance n. exc 50 m and burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft loose soil and returnig, filling in including sprinking of bleaching powder at the rate of 0.20 kg / Sqm and dressing of surplus soil around to slope complete all as specified and directed. |
| 95 | Demolition of brick work, built in cement mortar complete all as specified and directed. |
| 96 | Demolition of RCC n.exc 15cm thickness in any position complete all as specified and directed. |
| 97 | M&L for precast reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slab of manholes, septic tank etc,set in cement mortar 1:4 including necessary form, moulds etc and including taking out/removal of existing unserviceable cover slab from manholes /septic tank complete all as specified and directed. Note :- Reinforcement shall be measuredand paid separately. |
| 98 | M&L for Mild steel TMT bars 6 to 8mm dia as in reinforcement cut to length bent to shape required including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia complete all as specified and as directed. |
| 99 | Demolition and breaking up 150 mm bore drain pipes (SGSW/AC/RCC) set in cement mortor complete all as specified and directed. |
| 100 | Demolition and breaking up 100 mm bore drain pipes (SGSW/AC/RCC) set in cement mortor complete all as specified and directed. |
| 101 | Cleaning of blocked EWC by using rubber hand pump and opening the eye and making the line clear for smooth function complete all as specified and directed. |
| 102 | Cleaning of blocked IWC by using rubber hand pump and opening the eye and making the line clear for smooth function complete all as specified and directed. |
| 103 | Cleaning of blocked nahani trap in bathroom / kitchen or blocked gully trap by using rubber hand pump and opening the eye and making the line clear for smooth function complete all as specified and directed. |
| 104 | S&F in repairs, 75 mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 105 | S&F in repairs, 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed. |
| 106 | S&F in repairs, 110 mm bore, PVC (SWR) junction single, (Single T)equal or unequal complete all as specified and directed. |
| 107 | S&F in repairs, 110 mm bore, PVC (SWR) junction double, (Double T)equal or unequal complete all as specified and directed. |
| 108 | S&F in repairs 110 mm bore, PVC (SWR) Soil, waste and vent pipes single socketed, in any length with rubber ring joints laid in floors or trenches etc complete as required and as specified and directed. |
| 109 | S&F in repairs 75 mm bore, PVC (SWR) Soil, waste and vent pipes single socketed, in any length with rubber ring joints laid in floor or trenches etc complete as required complete all as specified and directed. |
| 110 | All as per Item No 109 above but fixed to walls. |
| 111 | Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide in Hard/dense soil for foundations etc and getting out complete all as specified and directed. |
| 112 | Returningfilling in incl spreading, levelling watering and well ramming in layers n.exc 25cm in soft/disintegrated rock complete all as specified and directed. |
| 113 | Removing excavated material to a distance exc 250m and nexc 500m and depositing where directed at a level n.exc 1.5m above the starting point in soft disintegrated rocks complete all as specified and directed. |
| 114 | Demolition of cement concrete (un-reinforced) of any description and in any position such as in bed for drain pipe etc complete all as specified and directed. |
| 115 | M&L 150 mm dia Reinforced concrete pipes, class NP3, laid and jointed with collars complete all as specified and directed. |
| 116 | M&L PVC (SWR) pipes 150mm single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 117 | S&F 75 mm PVC (SWR) floor trap, plainwith grating including jointing with solvent cement complete all as specified and directed. |
| 118 | S&F 125/110 mm PVC (SWR) gully trap,jointing with solvent cement complete all as specified and directed. |
| 119 | M&L for preparation of old plastered on unplastered surfaces of walls by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat exterior emulsion paint 100% acrylic, in camouflage pattern, any tinted, including washing floors, cleaning glass, joinery, electrical fittings, wiring etc or drops and splashes complete all as specified and directed. |
| 120 | M&L for preparation of old painted steel and iron surfaces of any description, not otherwise description over 10 cm width or girth and painting one coat with synthetic enamel paint in (camouflage pattern) including cleaning, stopping and rubbing down and removing all drops etc complete all as specified and directed. |
| 121 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces, in cement and sand mortar 1:4 using water liquid water proofing compound @200 ml per bag or cement or as per manufacturer\"s instructions and top surfaces finished even and fair without using extra cement complete all as specified and directed.Note : WPC shall be measured and paid separately. |
| 122 | Supply only water proofing compound ISI marked conforming to IS-2645-2003 complete all as specified and directed. |
| 123 | M&L for preparation of newly surfaces of walls and applying acrylic based emulsion (exterior grade) two coats, in camouflage pattern any tinted over a coat of suitable primer including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashed complete all as specified and directed. |
| 124 | M&L for taking down Cassete type air conditioner 3 TR,servicing, cleaning completely the cooling coil intially with hand blower,spraying with soap water solution and finally clean with clean water and refixing at same location with complete all as specified and directed. |
| 125 | Material and labour for dismantling indoor and outdoor covers of split type air conditioners, servicing, cleaning completely the condenser coil and cooling coil intially with hand blower, spraying with soap water solution and finally clean with clean water and refixing at same location with complete testing complete all as specified and directed. |
| 126 | Split type AC of capacity 1.5 TR |
| 127 | Split type AC of capacity 2.0 TR |
| 128 | Carrying out pressure leak test by nitrogen gas pressure for detecting leak in condensing unit refigerant pipe and repairing the leak by the welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe transporting & carrying out&required at site for work of following capacity ACs, water coolers & refrigertors & deep freezers all as specifed and diretced Notes :- Refrigeration gas charging as per existing type/ model / make after repairs is measured and paid seperately under revelant item. |
| 129 | Winodw type AC of capacity 1.5 TR |
| 130 | Split type AC of capacity 1.5 TR |
| 131 | Split type AC of capacity 2.0 TR |
| 132 | Cassete Type ACcapacity 3 TR |
| 133 | Refrigerator of capacity upto 220 ltrs |
| 134 | Refrigerator of capacity more than 220 ltrs upto 310 ltrs |
| 135 | Deep freezer of capacity upto120 Ltrs |
| 136 | S&F in repair compressor for window / split type / watercooler / refrigerator / deep freezezcomplete all as specified and directed. |
| 137 | Sealed unit rotary type for split type AC of capacity 1.5 TR |
| 138 | Sealed unit rotary type for split type AC of capacity 2.0 TR |
| 139 | Cassete Type ACcapacity 3 TR |
| 140 | For refrigerator of capacity upto 220 ltrs |
| 141 | For refrigerator of capacity more than 220 ltrs upto 310 ltrs |
| 142 | Labour only for collecting the complaints of various wards/ departments etc pertains to summer cooling applinaces (window acs / split acs / refrigerators / deep freezers) of any make / model/ type,from concern JE E/M of AGE E/M, attendending these at site to assess the actual fault after opening of cooling appliances and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user to concern JE complete all as specified and directed.Note:- Spares parts shall be measured and paid seperately under appropriate items as supply and fixed. |
| 143 | Supply only capacitor running 2.5 mfd |
| 144 | Supply only capacitor running 4.0 mfd |
| 145 | Supply only capacitor running 15 mfd |
| 146 | Supply only capacitor Running 36 Mfd |
| 147 | Supply only capacitor Running 45 Mfd +_ 4 Mfd |
| 148 | Supply only capacitor Running 50 Mfd +_ 6 Mfd |
| 149 | Supply only capacitor Starting 80/100 Mfd |
| 150 | Supply only capacitor Starting 100/120 Mfd |
| 151 | Supply only capillary tube copper as per existing size |
| 152 | Supply only filter strainer as per existing size |
| 153 | Supply only starting relay as per existing size |
| 154 | Supply only contactor relay as per existing size |
| 155 | Supply only open type relay as per existing |
| 156 | Supply only fix drain pipe as per existing |
| 157 | S&F in repair swing motor for air conditioners as per existing type/ make /model complete all as specified and directed. |
| 158 | Split type AC of capacity 1.5 TR |
| 159 | Split type AC of capacity 2.0 TR |
| 160 | Dismatling of blower fan motor cutting burnt coils and taking out from the AC Unit, cleaning and rewinding using supper enamaled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as specified and directed. |
| 161 | Split type AC of capacity 1.5 TR |
| 162 | Split type AC of capacity 2.0 TR |
| 163 | S&F in repair blower motor for air conditioners as per existing type/ make /model complete all as specified and directed. |
| 164 | Winodw type AC of capacity 1.5 TR |
| 165 | Split type AC of capacity 1.5 TR |
| 166 | Split type AC of capacity 1.5 TR invertor type indoor unit |
| 167 | Split type AC of capacity 2.0 TR invertor type indoor unit |
| 168 | S&F in repair PCB board for air conditioners as per existing type/ make /model complete all as specified and directed. |
| 169 | Split type AC of capacity 1.5 TR |
| 170 | Indoor unit PCB for Invertor type split AC of capacity 1.5 TR |
| 171 | Indoor unit PCB for Invertor type split AC of capacity 2.0 TR |
| 172 | Outdoor unit PCB for Invertor type split AC of capacity 1.5 TR |
| 173 | Outdoor unit PCB for Invertor type split AC of capacity 2.0 TR |
| 174 | Indoor unit PCB for cassete type AC of capacity 3.0 TR |
| 175 | Outdoor unit PCB for cassete type AC of capacity 3.0 TR |
| 176 | S&F in repair display assembly for air conditioners as per existing type/ make /model complete all as specified and directed. |
| 177 | Split type AC of capacity 1.5 TR |
| 178 | Split type AC of capacity 2.0 TR |
| 179 | S&F in repair copper condenser fins type for air conditioners as per existing type/ make /model / capacity complete all as specified and directed. |
| 180 | Split type AC of capacity 1.5 TR |
| 181 | Split type AC of capacity 2.0 TR |
| 182 | Supply and charging refrigeration gas R-22/R-32 for summer cooling appliances complete all as specified and directed. |
| 183 | Supply and charging refrigeration gas R-410 for summer cooling appliances complete all as specified and directed. |
| 184 | Supply and charging refrigeration gas R-134A for summer cooling appliances complete all as specified and directed. |
| 185 | Labour only for dismantling, shifting and refixing of split type AC (indoor and outdoor unit complete)of any capacity /make / model including proper arrangement to keep outer unit (angle iron with nut bolt) complete all as specified and directed. |
| 186 | Taking down outdoor unit in repairs of any type /make /model/ capacity split ac, removing unserviceable AC stand/angle iron bracket fixing new AC stand/angle iron bracket (including two coats of paint over a red oxide primer) fixing to wall by foundation bolts refixing the outdoor unit at any height with connecting the suction and discharge line complete with testing and running complete all as specified and directed by the engineer-in- charge. |
| 187 | Dismatling of existing old unserviceable copper tubes and supply and fixing in new matching to exist one including all connection, testing etc complete all as specified and directed. |
| 188 | 5/8\" copper tube |
| 189 | 1/4\" copper tube |
| 190 | 1/2\" copper tube |
| 191 | Taking down damaged copper tubes insulation and supply and fixing in new complete all as specified and directed. |
| 192 | 5/8\" copper tube insulation |
| 193 | 1/4\" copper tube insulation |
| 194 | 1/2\" copper tube insulation |
| 195 | Taking down unserviceable voltage stablizers, rewinding of isolation transformer unit with heavy duty super enamelled copper winding wire of existing gauge including all insualtion materials, varnishing, heating etc and replacement of defective parts required to maintain constant voltage complete all as specified and directed. |
| 196 | Capacity up to 3 KVA |
| 197 | Capacity 4 KVA |
| 198 | Capacity 5 KVA |
| 199 | Capacity 7.5 KVA |
| 200 | S&F in repair / replacement ofswitch socket & plug combined in LM6 cable termination box in LM6, 25A, 2P+earth, 230V complete all as specified and directed |
| 201 | S&F in repair / replacement ofmodular switch 1 way 16 Amps, 1 module, 230 volt, as per existing make/type complete all as specified and directed. |
| 202 | S&F in repair / replacement ofmodular socket 1 way 6/16 Amps, 3/3 pin combined, 2 module, 230 volt,as per existing make/type complete all as specified and directed. |
| 203 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |