Tender For Addn Altn And Spl Repair Of Rsoi At Umroi Mil Stn Under Ge Umroi, umroi-Meghalaya

Military Engineer Services has published Tender For Addn Altn And Spl Repair Of Rsoi At Umroi Mil Stn Under Ge Umroi. Submission Date for this Tender is 15-07-2025. Cleaning Rags and Cloths Tenders in umroi Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

49827982
Tender For Addn Altn And Spl Repair Of Rsoi At Umroi Mil Stn Under Ge Umroi
Tender
Indian
Meghalaya
Umroi
15-07-2025

Tender Documents

Tender Details

Tender For Addn Altn And Spl Repair Of Rsoi At Umroi Mil Stn Under Ge Umroi; 1 Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed. 2 Material and labour for 15 mm thick rendering in cement mortar (1:6) onfair faces of brick work or concrete surfaces,finished even and smooth without using extra cement all as specified. 3 Material and labour for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces in two layers (10mm thick 1st layer + 5mm thick finishing layer) of walls, chajja, fins, facia etc. any height mixed with water proofing compound (for 5mm thick finishing layer only) @ 200 ml per 50 kg of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified and directed.Note: (i) Liquid water proofing compound will be measured and paid separately(ii) Cost of scafolding, any height are deemed to be inclusive in the quoted rate. 4 Supply only Liquid water proofing compound. 5 Material and labour for 5 mm thick rendering in cement mortar (1:3) on concrete surface as in ceiling/chajja finished even and smooth without using extra cement complete all as specified and directed. 6 Material and labour for preparation of new plastered surfaces and applying two coat of oil emulsion distemper (any colour/tint) on ceiling surfaces complete all as specified and directed. 7 M&L for preparation of new plastered surfaces and applying two coats of oil emulsion distemper (any colour/tint)over a coat of primer and 1mm thick wall care putty complete all as specified and directed. 8 M & L for complete removal of existing finishes and treating with two coats of oil emulsion distemper (any colour/tint) over a coat of primer and 1mm thick wall care putty complete all as directed and specified. 9 Material & Labour for preparation of new plastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. 10 Material & Labour for preparation of old plastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and as directed. 11 M&L for preparation of old plastered ceiling surfaces and applying two coat of oil emulsion distemper (any colour/tint)on ceiling surfaces, complete all as specified and directed. 12 Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil all as specified anddirected. 13 Material and labour for providing Plain Cement Concrete (1:4:8) type D2 using 40 mm graded aggregate as in foundation, filling and mass concrete complete all as specified and directed. 14 Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm in soft/loose soil all as specified and directed. 15 Removing surplus excavated materials (soils) upto a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. 16 Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. 17 M&L for precast cement concrete block masonry 1:3:6 type C1 (20 mm graded stone aggregate) with solid blocks, exc 10 cm in width and setting in CM 1:6 complete all as specified and as directed. 18 Material and labour for 15 mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and fair complete all as specified and directed. 19 M & L for RCC 1:2:4 type B-1(Nominal Mix) ( using 20mm graded stone aggregate) in foundation, including raft footings, foundation beams, plinth beams, bases for column etc., basement slabs, underreamed piles and mass concrete etc. complete all as specified and as directed. 20 M & L for RCC 1:2:4 type B-1(Nominal Mix ) ( using 20mm graded stone aggregate)in beams, cantilevers, bressummers, lintels over 1.5m span etc. complete all as specified and as directed. 21 M & L for RCC 1:2:4 type B-1(Nominal Mix ) ( using 20mm graded stone aggregate)in columns, pillars, piers, posts and struts etc. complete all as specified and as directed. 22 S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. 23 M&L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. 24 Use and waste of formwork to sides of column, pillars, posts, stanchions for rough finished surface complete all as specified and as directed. 25 Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams; and similar work; vertical or to batter(flat) complete all as specified and as directed. 26 Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 27 M&L for Green Marble 18 to 20mm thick(table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble over and including 15mm thick screed bed/bedding layer in CM 1:4 complete all as specified and directed. 28 M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. 29 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. 30 M&L for vitrified ceramic tiles light shade 8 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42Sqm but not exceeding 1 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. 31 M & L for 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor tiles, etc. complete all as specified and directed. 32 Material and labour for coloured glazed ceramic tiles in vertical surfaces 350 x 250 x 7mm/450 x 350 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering (backing coat) in CM 1:4complete all as specified and directed. 33 Taking down chowkhats or frames with shutters (without taking off shuttersfrom the frames) exceeding 1.5 Sqm but not exceeding. 4.00 sqm each complete all as specified and directed. 34 S & F anodised aluminium frame, powder coated (minimum thickness 50 micron)for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 35 S & F Anodised aluminium powder coated (minimum thickness 50 micron) door shutters, aluminium section weighing 0.75 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, lock, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed. 36 Supply & fixing sheet glass ordinary quality 5.50m thick glazing in square/ rectangle not exc 0.50 sqm each pane with oil putty or aluminium beads fixed to steel frame, etc. completeall as specified and as directed. 37 M & L for medium density fibre board, 12mm thick, exterior grade, fixed to aluminium framework with screws/Aluminium cleat etc. completeall as specified and as directed. 38 Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or on the side of waist slab with suitable arrangement complete all as specified and as directed. 39 Taking down wall panelling, false ceiling and similar work complete all as specified and as directed. 40 S&F Hollow PVC Wall Lining consisting of 5mm thick PVC sheetany colour inclusive of solvent cement and fixing at site on suitable frame work as per specifications and as per direction of Engr-in-charge. 41 S & F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling sectionof 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre etc. complete all as specified and as directed. 42 S&F 10mm thick PVC insulation panels with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of GI frame work as per specification and drawing complete all as specified and as directed. 43 Material and labour for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust etc and applying roof treatment with the following steps and specifications:- a) Applying cement slurry over concrete surfaces @3kg/sqm. b) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound @ 3% by weight of cement or @ 200ml per 50 Kg of cement or as per manufacturers instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof (levelling course).c) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @0.25 litres per sqm conforming to IS : 3384-1986.d)Applying evenly one coat of blown hot bitumen of grade 85/25@ 1.20Kg square metre on primed surfaces.e) A layer of APP based polymeric membrane, 3mm thick(minimum), weighing 3.5 kg/m2 reinforced with polyster non woven fabric (weighing not less than 160gms/Sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. f) Applying evenly one coat of aluminium paint @ 0.10litre per square metre over the APP based polymeric membrane. 44 Taking down eaves gutters, sewage lines andrainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swannecks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. 45 M & L for 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in floors complete all as specified and directed. 46 S & F 110 mm bore PVC (SWR) bends any radius with access door complete all as specified and directed. 47 S&F for 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal with access door including necessary scafoldingupto any height complete all as specified and directed. 48 M&L for 100mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, including making good disturbed area/surfaces with cement concrete/cement mortar 1:2:4 etc including taking down old unserviceable Nahani/Floor trap complete all as specified and directed. 49 S&F in repairs 15mm dia Bib tap, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. 50 S&F in repairs wall mixture tap, 15 mm dia chromium plated, fancy type, with long shank and cup cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and directed. 51 S&Fin repair 15 mm size stop valve, fancy type, chromium plated, cast copper alloy, long shank, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union & fixed complete all as specified and directed. 52 S&F in repairs wash hand basin mixture tap, 15 mm dia chromium plated, fancy type, cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and directed. 53 Taking up or down steel tubing 15mm boreand connections including cleaning for refixing or removal to store complete all as specified and directed. 54 Taking up or down steel tubing 20mm boreand connections including cleaning for refixing or removal to store complete all as specified and directed. 55 S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. complete all as specified and directed. 56 S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. complete all as specified and directed. 57 S&F in repairs 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers compete all as specified and directed. 58 S&F Brass mortice lock, vertical type of size 100 mm, 4 levers complete all as specified and directed. 59 S F in repair Vitreous china premium/1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern including all necessary accessories like rag bolts/ gel gasket, seat cover, etc (excluding flushing cistern & flush pipe) but including fixing bolt and necessary connection with existing pipes complete all as specified and directed. 60 S&Fin repairs brass chromium plated shower rose 125mm size, including fixing to steel pipe or union complete all as specified and directed. 61 S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. 62 S&F 10 litres CapacityPVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets & flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern & fixing/connecting to pipes complete all as specified and directed. 63 Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls etc complete all as specified and directed. 64 M & L for 75mm thick cement concrete 1:4:8 type D2(using 40mm graded stone aggregate) as in sub base of floor complete all as specified and directed. 65 M & L for endura tiles of size 300mm x 300mm x 10mm thick, suitable for hi-turf external tiles, anti skid, scratch resistance and neutral to UV rays and acid/alkali resistance as in floor over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. 66 S & F in repair Vitreous China bowl urinal flat back, size of 590x400x380mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern) including flushing pipe and outgoing pipes complete all as specified and directed. 67 Dismantling water tanks exc 250 litres capacity and n.exc 500 litres capacity and removing to store complete all as specified and directed. 68 Supply and fix rotational moulded, multilayer HDPE water storage tank of 500 litres capacity( tripple layer wall construction, cylindrical vertical with closed top)ISI marked, hoisted and fixed in position all as specified in SSR Part I including 02 Nos 20 mm bore full threaded GI nipple of required size including ball valves 20 mm bore high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm - 210gms) and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed 69 S&F Factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet complete all as specified and directed. 70 Supply and fix Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2 mm thick Moulded PrelamPVC sheet on the front face & 2mm plain colour PVC sheet on back face, andfixing in frame at site as per specification and drawings complete all as specified and directed. 71 S&F 100 mm long butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. 72 S&F 100 mm long extruded aluminium alloy handles, fabricated type, anodizedcomplete all as specified and directed. 73 S&F 100 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. 74 S&F in repair PVC connection of size 15 mm dia, 450 mm long with PTMT nuts complete all as specified and directed. 75 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. 76 Material and labour for concealed modular point wiring with 1.5 Sqmm PVC insulated and unsheathed multi stranded (FRLSH) flexible copper conductor cable inand including rigid PVC conduit concealed /PVC surface conduit withmodular cover plate and sunken boxofadequate size for one light or one fan point controlledby one switch including 1.5 Sqmm (FRLSH) PVC insulated andunsheathed multi stranded flexible copper conductor cable as earth wire(green colour) connecting to common earth dolly complete all as specified and directed. Notes: (i) The quoted rate shall deemed to be inclusive for cutting chases and making good the existingsurfaces for complete concealed wiring. (ii) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan, etc with proper fixing clips all as directed and rate for the same are deemed to be inclusive in the unit quoted rate. 77 All as per serial item No 76 here in before but for one 3 pin 5 Amp socket outlet on independent board. 78 All as per serial item No 76 here in before but for one 3 pin 5 Amp socket outlet on same board. 79 Material and labour for concealedmodular point wiring with 4.0 sqmm PVC insulated and unsheathed multi stranded (FRLSH) flexible copper conductor cable drawn in and including rigid PVC concealed conduit medium grade of suitable size with modular cover plate and sunken box of adequate size with suitable thickness plastic laminated sheet cover for one 3 pin socket outlet 15 Amp on independent board including continuous 4.0 sqmm copper conductor cable (FRLSH) (multistranded) PVC insulated and unsheathed cable as earth wire connecting to common earth dolly complete all as specified and directed.(i) The quoted rate shall deemed to be inclusive for cutting chases and making good the existingsurfaces for complete concealed wiring. (ii) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan, etc with proper fixing clips all as directed and rate for the same are deemed to be inclusive in the unit quoted rate. 80 M&L for Modular cover plate with frame and Modular metal flush box 6 module complete all as specified and directed. 81 M&L for Modular cover plate with frame and Modular metal flush box 4 module complete all as specified and directed. 82 M&L for Modular cover plate with frame and Modular metal flush box 3 module complete all as specified and directed. 83 M&L for Modular cover plate with frame and Modular metal flush box 2 module complete all as specified and directed. 84 M&L for Modular cover plate with frame and Modular metal flush box 1 module complete all as specified and directed. 85 M&L for ceiling rose surface bakelitetwo to three terminal isolated body fixed on PVC round block complete all as specified and directed 86 M&L for Modular switch 6 Amp one way switch white complete all as specified and directed. 87 M&L for Modular socket 6 Amp 2/3 pin combined 2 module complete all as specified and directed. 88 M&L for Modular socket6 Amp /16 Amp2/3 pin combined2 module complete all as specified and directed. 89 M&L for Modular switch 16 Amp one way white complete all as specified and directed. 90 Supply and fixing in repair 25 Watt warm white energy saving environmental friendly, long life, corrosion resistant, decorative recessed luminaries with PMMA diffuser and extruded aluminium housing complete all as specified and directed . Note: Old serviceable lights to be deposited to MES Store. 91 Supply and fixing in repair LED picture light fitting 1x 7 Watt ( Warm White) , 2 ft , 100 lm/W complete all as specified and directed. 92 Supply and fixing in repair/replacement MCB DB 4 way vertical sheet metal enclosure suitable for fixing MCB of appropriate capacity as incomer and SP for outgoing, 415 volts, 50 Hz, with IP-43 protection, double door with200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and directed. 93 Supply and fix in repairs of MCB SPN DB 8 way double door, IP 43 protection, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09 complete all as specified and directed. 94 Supply and fixingin repair/replacement MCB distribution board, 240 volts single pole andneutral, double door, sheet steel enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. 95 Supply and fixing RCBO with earth leakage, over load and short circuit protection, DP, 240 Volts, 32 Amps, 30 mA senstivityincluding taking down old one complete all as specified and as directed. 96 S&F MCBs SPN, 6 to 32 Amps with 10 KA breaking capacity C series confirming to IS/IEC 60898-1 (ISI marked), complete all as specified and directed. 97 S&F for MCBs SP, 6 to 32 Amps with 10 KA breaking capacity of C series confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed. 98 S&F in repair/replacement existing sub main wiring concealed with three run of single core (FRLSH) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area6.0 Sqmm drawing into and including PVC non metallic rigid conduit of adequate size with proper colour coding and making electric connections, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed. Note:- (i) The quoted rate shall deemed to be inclusive for cutting chases and making good the existingsurfaces for complete concealed wiring. (ii)Three run of6.00 sqmm single core (FRLSH) PVC insulated copper conductor cable and one run of PVC conduit of suitable size will be measured as one run. 99 S&F in repair/replacement of existing sub main wiring concealed with three run of single core (FRLSH) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 1.5 Sqmm drawing into and including PVC non metallic rigid conduit of adequate size with proper colour coding and making electric connections, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed. Note :- (i)The quoted rate shall deemed to be inclusive for cutting chases and making good the existingsurfaces for complete concealed wiring. (ii)Three run of1.5 sqmm single core (FRLSH) PVC insulated copper conductor cable and one run of PVC conduit of suitable size will be measured as a one unit. 100 Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to earth lead wire 4 mm dia by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execuation and earth works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I complete all as specified and directed. 101 S&F for 32 mm dia GI tubing( light grade) bracket over all 1.2 m long with cutting as required and bend to shape with flat iron clamp of size 32 mm 2 Nos, suitable size of nut bolts and washers for fixing street light fittings on electric poles including taking down old unserviceable fully rusted existing one complete all as specified and directed. 102 S&Fin repair LED street light fittings in aluminium PDC housing, toughened glass cover, individual LEDs with secondary optics covered with IP66 protection of capacity 30W/35W complete all as specified and directed. 103 S&F Sleek design 18 W LED warm white ceiling lighthaving wide voltage protection (160V-300V) and Surge protection complete all as specified and directed . 104 Material & Labour for cutting of circular/square hole on any type of wall and suitable size for fixing of exhaust fan of size250mm sweep, grouting04 Nos 100mm long 12mm dia stud bolt including,making good to disturbed surfaces of wall to match as per the existingcolour complete all as directed by engineer-in-charge. 105 Supply and fix exhaust fan, fibre body AC single phase, 230V of size 250mm sweep with, blades, frame and louvers complete all as specified and directed by Engr-in-charge. 106 Supply and fix electric water heater, storage type. steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, non return valve, connection piece etc complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 77000.0 /-
Tender Value
INR 38.50 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail