On-grid Electrification of Households under DA-JGUA in District Poonch (UT of Jammu and Kashmir) for JPDCL under the Revamped Reforms-based and Results-linked, Distribution Sector Scheme (RDSS)= 1 8 Mtr. Long Pole (ST-410 SP15) 2 9 Mtr. Long Pole(ST-410 SP33) 3 11 Mtr. Long Pole(ST-410 SP56) 4 30 mm² ACSR Conductor 5 50 mm² ACSR Conductor 6 11/0.433-0.250KV;50Hz,25 KVA Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment. 7 11/0.433-0.250KV;50Hz, 63 KVA Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with xternally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings. Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) 8 11/0.433-0.250KV;50Hz, 100 KVA Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with xternally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings. Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) 9 LT Distribution Box for 25 kVA DTR withMCCB for incomer & Outgoing Circuits 10 LT Distribution Box for 63 kVA DTR withMCCB for incomer & Outgoing Circuits 11 LT Distribution Box for 100 kVA DTR withMCCB for incomer & Outgoing Circuits 12 Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type 13 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type 14 11 kV Horn GapFuse Set 3 Phase 200A 15 GI V cross-arm with top Bracket including clamp 16 GI Channel X-arm including clamps and braces 17 GI Channel/Angle/Flat of sizes including clamps 18 Galvanized Nuts and Bolts 19 PG Clamps for 50 mm² ACSR Conductor 20 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 21 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 22 25 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type 23 70 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type 24 50 mm² Cable (2Ckt) , 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type 25 GI Rod 20mm 2.5 mtr long through GI Strip. 26 Earthing of substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 27 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete 28 Danger Plates with Clamps 29 Anti-Climbing Device with Clamps 30 Red Oxide 31 Aluminium Paint 32 Aluminium Jointing Sleeves 33 GI U-Clamps for Shackle Insulators 34 16kN Polymer Shackle Insulators 35 LT Line Spacers 36 32/63 amps TPN Switch Disconnector Fuse Unit 37 Sundry items like aluminium lugs, Jumpers, binding Tape, 38 Wedge Connectors / PG Clamps 39 3-Ø, 4-Wire Trivector Meter with CT 40 Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole 41 Cement bottoming 1:2:4 mix as per REC standards .5cum /pole 42 GI Barbed Wire for Anti Climbing Device