| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group c |
| 3 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 4 | Group c |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. |
| 6 | 2 x 1.5 Sqmm + 1 x 1.5 Sqmm earth wire |
| 7 | 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire |
| 8 | 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 10 | 25 mm medium class PVC conduit |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 12 | 5/6 amps switch |
| 13 | 15/16 amp switch |
| 14 | 3 pin 5/6 amp socket outlet |
| 15 | 6 pin 15/16 amp socket outlet |
| 16 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 17 | 2 Module |
| 18 | 3 Module (100mmX75mm) |
| 19 | 6 Module (200mmX75mm) |
| 20 | 12 Module (200mmX150mm) |
| 21 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.(1 run) |
| 22 | Single Run of cable |
| 23 | Supplying and fixing of RJ 45 connectorfor CAT 6 connectioni/c punching etc as reqd |
| 24 | Supplying and fixing of RJ 11 telephoneSocketwith accessories & cable punching for telephone wire for the telephone services etc. as reqd.( Make : D-Link/ Anchor ) |
| 25 | Supplying and fixing of RJ 45 Computer Socket IO with accessories & cable punching for local area networking of computers through database servers etc. as reqd.( Make : D-Link/ Anchor Roma) |
| 26 | LED Panel light 1x1 ft., (System lumen efficacy >120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 1x1 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), DCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). (Make: M/s Phillips / Havells / Wipro) |
| 27 | 22w, 6500K, 300x300 mm recessed LED panelin plastic body, 1650 lumens |
| 28 | LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 degcentigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), DCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). (Make: M/s Phillips / Havells / Wipro)CRCA Sheet Body (Thickness ≥ 0.50 mm) |
| 29 | 36Watt |
| 30 | LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt )Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Opencircuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be ofelevant BIS standard and trade mark certificate ( T.C.). anufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). (Make: M/s Phillips / Havells or Wipro)Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 31 | 5-7watt |
| 32 | 11-15 watt |
| 33 | Supply and fixing of 250MM FRESH AIR FAN following type suitable for operation i/c dismantaling/ refixing, minor civil works if reqd. making connection testing and commissioning etc complete as reqd. (Make: Almonard/ Crompton/ Havells/ Usha/ Orient) |
| 34 | SITC of following type BLDCceilng fan suitable for operation on 230V, 50 Hz single phase AC Supply complete as reqd. (Make: Atomburg Ikano / Havells/ Kuhl or SS make and model) |
| 35 | 1400 mm sweep, Ceiling fan |
| 36 | SITC of following type heavy duty exhaust/ wall/ ceiling/ pedestal fans suitable for operation on 230V, 50 Hz single phase AC Supply complete as reqd. (Make: Almonard/ Crompton/ Havells/ Usha/ Orient) |
| 37 | 400 mm sweep, 1350 rpm, Plastic body wall fan |
| 38 | Supply & laying of 3.5x35 Sq.mm size of PVC insulated, PVC sheathed armoured, aluminium conductor power cable of 1.1 kV grade i/c connections etc complete as reqd.(Havells / Finolex / Polycab make). |
| 39 | Supply & fixing following sheet steel MCBDB,on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 40 | 6 way , 240v SPN, Double door |
| 41 | 4 way (4+12), 415v, Horizontal, TPN, Double door |
| 42 | Supply & fixing 5 A to 32 A rating, 240/415 volts, 10 kA, \"C\" curve,MCBsuitableforinductiveloadof following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (M/s Crompton / Havells / lndokopp / MDS Legrand/ L&T / Schneider Electric/ Siemens / Sandard/ABB/ HPL ) |
| 43 | Single Pole |
| 44 | Double Pole |
| 45 | Supply & fixing following isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (M/s Crompton / Havells / lndokopp / MDS Legrand/ L&T / Schneider Electric/ Siemens / Sandard/ABB/ HPL ) |
| 46 | 40 A, Double Pole, 240 V |
| 47 | 63 A, Four Pole, 415 V |
| 48 | Supplying/fixing of single Blanking plate in the existing DB etc as reqd |
| 49 | Supplying and fixing of Double USB charger socketas reqd.( Make : D-Link/ Anchor Roma/legrand) |
| 50 | Dismantling of the completelight/ fittings/ ceiling fans/Distribution board (DB\"s)from the recess/ cables etc complete of the area i/c 3/4 Nos split AC unitscomplete with disconnection, collection at common location and shifting to the safe place in the premises etc complete with cleaning of surface complete as reqd. |
| 51 | Less Credit for dismantled material obtained from all above items of Sub Head-II which will be the property of the Contractor.(-) |