| 1 | Operation and Routine Maintenance of Sub-station equipment having Dry type transformers1500 KVA-2 Nos(11 KV/415 V Indoor type) i/cHT panel, L.T. panels, capacitor panels & floor panels etc. and 2 x 1250 KVA D.G. sets with PLC/SCADA system i/c other allied panels etc. as per additional condition, inventory & schedule of routine maintenance is given in Annexure \"A\" and \"B\". etc complete as required. (For TT Building) Operation shall be done by deploying, following staffa) Electrician cumOperator- 3 Nos. (One No. in each shift total 3 shifts. i.e.06 AM to 02 PM, 02 PM to 10 PM & 10 PM to 06 AM ).b) Khallasi - 1 No.( one in general shift) |
| 2 | Operation and Routine Maintenance of Sub-Station equipment having Oil type transformers 1250 KVA - 2 Nos. (11 KV/415 V Indoor type) i/c HT panel, L.T. panels, capacitor panels & floor panels etc. and 1 No. of 750 KVA D.G. setsi/c other allied panels etc. as per additional condition, inventory & schedule of routine maintenance is given in Annexure \"A\" and \"B\". etc complete as required.(Training Venue)Operation shall be done by deploying, following staffa) Electrician cumOperator- 3 Nos. (One No. in each shift total 3 shifts. i.e.06 AM to 02 PM, 02 PM to 10 PM & 10 PM to 06 AM ).b) Khallasi - 1 No.( one in general shift) |
| 3 | Servicing (B-Check Maintenance) of 1250 KVA DG set by deploying authorise mechanical engineer from Cummins Svam Sales & Service Ltd. including supply and replacement of following sparesas required.A) Seal , O Ring (Cummins Item code - 3010937) ....................................2 Nos.B) Inhibitor, Corrosion(Cummins Item code -3167218) ........ ..................1 No. C)Strip Test ( CumminsItem code- 4912590)............ ............................1 No.D) Premium Blue 140 liter Oil (Cummins Code - PB 15W40210)................1 No. E) Element Lub Oil Filter (Cummins Item Code - KIT3238204)..................4 Nos. F)KIT Fuel Filter and Ring (Cummins Item Code - KIT3238493)..............2 Nos.G)KIT Super By Pass Filter Element (Cummins Code - KIT3879488)....- 2 Nos. H) kit Air Cleaner elements (K,QSK,V series).........................................2 Nos.I) Endicator restriction (3872813)J)Radiator cleaning / D scaling :-........................................................... 1 No. K)Radiwash 3 ltr (AX1013359) :-...........................................................15 NosL) B-check maintenance service charges for Cummins DG set (Cummins Item Code - CSSER1010TO1500)......................................................................... 1 job. |
| 4 | Servicing (B- Check maintenance) of 750 KVA DG Set by deploying authorized Machanical Engineer from Cummins Svam Sales & Service Ltd.including supply and replacement of following spares as required. A) Element Lub Oil Filter (Cummins Item Code - KIT3238204)......................4 Nos. B) KIT Fuel Filter and Ring (Cummins Item Code - KIT3238493).............. ....2 Nos. C) KIT Super By Pass Filter Element (Cummins Code - KIT3879488)..........2 Nos.D)Inhibitor, Corrosion(Cummins Item code -3167218) ................................1 No.E) Seal , O Ring (Cummins Item code - 3010937) .......................... .......... ....2 No.F) kit Air Cleaner elements (K,QSK,V series)................. ...............................2 Nos.G) Premium Blue 90 liter Oil (Cummins Code - PB 15W40210).....................1 No. H) Radiator cleaning / D scaling......................................................................1 job. I)Radiwash 3 ltr (AX1013359) :-...................................................................10 NosJ) Strip Test ( CumminsItem code- 4912590)................................................1 No K) the B-check maintenance service charges for Cummins DG set (Cummins Item Code - CSSER1010TO1500)..........................................................................1 Job |
| 5 | Supplying and making straight through joint with heat shrinkable kit includingferrules and other jointing materials for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1KV grade as reqd. |
| 6 | 3½ Cx300 sq.mm |
| 7 | 3½ Cx240 sq.mm |
| 8 | 3½ Cx185 sq.mm |
| 9 | Charges for detection of cable fault in the existing underground LT cable of different sizes i/cpin pointing in the same by FLC equipment etc. complete as reqd. |
| 10 | Digging of Pit for providing cable joint as per site located by fault Locator machine including refilling of soil complete as required. |
| 11 | Running Maintenance & Operation of fire fighting i/c sprinkler system and fire alarm system including routine & preventive checking/ maintenance (as per annexure - C) etc. as per inventory and additional terms and conditions enclosed by deploying the following staff :-a) Operator – 3 Nos.(1 No. in each shift total 3 shifts i.e. 6 AM to 2 PM & 2 PM to 10 PM & 10PM to 6AM)b) Khallalsi– 3 Nos.(1 No. in each shift total 3 shifts i.e. 6 AM to 2 PM & 2 PM to 10 PM & 10PM to 6AM) |
| 12 | Refilling of different type of fire extinguisher Minimax make including cartage, loading, unloading and testing etc. complete as reqd. |
| 13 | 10 kg. DCP type |
| 14 | 5 kg. DCP type |
| 15 | 4.5 kg CO2 type |
| 16 | 9 liters Mechanical Foam type |
| 17 | 9 liters water type gas cartridge |
| 18 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
| 19 | Stainless Steel (Grade 304) |
| 20 | Supply &Replacement, Installation, testing and commissioning of Edward make Photo cum heat detector modal SIGA 2PHS + Base complete as required |
| 21 | Supply &Replacement, Installation, testing and commissioning of Edward make Manual Call Point Modal SIGA 271/278 complete as required. |
| 22 | Operation of 6 Nos. liftsas per inventory enclosed as per terms & conditions by deploying following staff :-i)Rescue Operator (for lift): 1 No. (1 No. in general shift i.e.9 AM to 5 PM) |
| 23 | (Operation of Bio Composter machine )Operation and Maintenance of Bio Composter machine (Capacity- 500 Kg). as per inventory enclosed as per terms & conditions by deploying following staff :-i) Operator: 1 No. (1 No. in general shift i.e.9 AM to 5 PM) |
| 24 | (Maintenance & operation of IEI and Submersible Pump )Running, Maintenance & operation of internal electrical installations, external lightingand high mast lighting, PLC/SCADA & submersible pump sets as per inventory and Additional conditions enclosed by deploying following staff.i) Electrician cum operator - 3 Nos.( one in each shift total 3 shifts.)ii) Khallasi - 2 Nos.( one in each shift total 2 shifts.)All tools and plants including tower wagon suitable to maintained fittings mounted up to height 12 mtrs. shall be made available at the site throughout the contract period.And alsomaintenance including routine/ preventive maintenance, repairs and replacement of defective components/ accessories of PLC Panels and SCADA System of Sports Lighting of Match Court/ Show court as per additional conditions and Annexure enclosed etc. completeas required. |
| 25 | Supplying and Replacement (including deduction of cost for replaced item) of FRLS PVC insulated copper conductor wire offollowing sizein the existing surface/ recessed conduit i/c connection, testing etc.as required. |
| 26 | 1x 1.5 sq.mm |
| 27 | 1x 2.5 sq.mm |
| 28 | 1x 4.0 sq.mm |
| 29 | Supply and Replacement (including deduction of cost for replaced item) following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 30 | 5/6 Amp Switch |
| 31 | 15/16 Amp Switch |
| 32 | 3 pin 5/6 Amp Socket outlet |
| 33 | 6 pin 15/16 Amp socket outlet |
| 34 | Supplying and Replacement (including deduction of cost for replaced item) following rating, 240/415 V, 10 kA, \"C\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB/ Electrical Panel Board/ feeder pillar/ street light pole complete with connections, testing and commissioning etc. as required. |
| 35 | 5 to 32 AmpSP MCB \"C\" series |
| 36 | 40 AmpTPN MCB \"C\" series |
| 37 | 40 AmpDP MCB \"C\" series |
| 38 | 16 to 32 AmpDP MCB \"C\" series |
| 39 | 63 Amp four pole MCB \"C\" series |
| 40 | Providing and Replacement (including deduction of cost for replaced item) following rating and breaking capacityand pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 41 | 100 A, 16 KA, TPMCCB with Terminal spreaders |
| 42 | 125 A, 16 KA,TPMCCB with Terminal spreaders |
| 43 | 250 A, 35 KA,TPMCCB with Terminal spreaders |
| 44 | Supplying and Replacement (including deduction of cost for replaced item) following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 45 | 63 A |
| 46 | Supply of PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable (As per IS 7098 (Part-1) of 1.1 KV gradein existing DWC pipe i/c connection testing etc.as required. |
| 47 | 2 x10 sq.mm |
| 48 | 2 x 16 Sqmm |
| 49 | Lifting out of submersible pump set from the existing bore well up to the required depth along-with existing G.I. pipes and accessories etc. i/c dismantling of G.I pipe and disconnecting the sub. cable etc. complete as reqd. |
| 50 | Lowering of sub. pump set in the existing bore well up to the required depth along with existing G.I pipe and sub. Cable etc, water proof jointing of sub. cable. Replacement of reqd. nuts, bolts, washers and packing, nipple, reducer, connection testing, etc. complete as reqd. |
| 51 | Supplying of copper conductor flat submersible cable offollowing sizei/c testing etc. complete as reqd. |
| 52 | 3 x 2.5 sq.mm |
| 53 | 3 x 4 sq.mm |
| 54 | 3 x 6 sq.mm |
| 55 | Supplying of following size of double G.I. flanged (ISI marked ) GI pipe \"B\" class duly threaded & welded with necessary pipe fittings, bends, elbow etc. complete as reqd.a) 65 mm dia. |
| 56 | Supplying of following size of double G.I. flanged (ISI marked ) GI pipe \"B\" class duly threaded & welded with necessary pipe fittings, bends, elbow etc. complete as reqd.a) 50 mm dia. |
| 57 | Repairing and rewinding of Submersible motorsof following capacity with cartage, dismantling, reassembling i/c supply &replacement/ repairing of all damaged parts of motors and making good for operation i/c connection, testing, painting etc. complete as required. |
| 58 | Upto 2 HP single/ three PhaseSubmersible motor |
| 59 | 5 HP/7.5HP three Phase Submersible motor |
| 60 | 10 HPthree Phase Submersible motor |
| 61 | Repairing of Submersible Pump 3 Phase of following stages & dia. with cartage, dismantling, reassembling i/c supply &replacement/ repairing of all damaged parts of pump and making good for operation i/c connection, testing, painting etc. complete as required. |
| 62 | Upto all stage 4\" dia. Submersible pump set |
| 63 | Upto all stage 6\" dia. Submersible pump set |
| 64 | Supply and Replacement of following Control Gear/ accessories in the existing installation for the Electric Panel of submersible pump set i/c connection with suitable size thimbles and fixing the panel in the existing feeder with nut bolts after drilling etc. complete as required. |
| 65 | Single Phase Preventor |
| 66 | D.O.L. Starter (9-14 Amp.) |