Housing Urban and Rular Development Government Departments Closing in 0 days TDR #49804448

Construction Of Sewage Treatment Plant (Stp) In Bomdila In West Kameng, A.P

Issued by Government Departments · West kameng, Arunachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Jul 2025
0 days left
EMD
7.11 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
West kameng → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Sewage Treatment Plant (Stp) In Bomdila In West Kameng, A.P

BOQ

Name of Work:Const. of Sewage Treatment Plant with Co-Treatment of Faecal Sludge/Septage with capacity of 0.80 MLD at Bomdila, AP
Sl. No. Item Description
1Construction of Sewage Treatment Plant - 0.80 MLD
2Construction of RCC elevated Platform for screen channel and Grit Chamber
3Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m in all types of soils for footings
4Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m 10% of the Total Qty
5Filling with sand including watering, ramming, consolidating and dressing complete.Below CC bed Below CC bed
6Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC Bed
7Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Footings
8Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Pedastal
9Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
10Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Plinth BeamBracing Tie Beam @ 4m heightRoof Beam
11Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Roof Slab
12Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC Bed FootingsPedastal
13Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.Columns upto GLColumns Above GL
14Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.Roof BeamRoof Beam BottomRoof Beam Sides
15Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).Roof SlabRoof BottomRoof Sides
16Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelFootingsPedastalColumns upto GL Columns Above GL Plinth Beam Bracing Tie Beam @ 4m height Roof Beam Roof Slab
17Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksfor Lader
18Construction of RCC channel for Grid Chamber Fine Screen & Medium Screen
19Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)RCC Walls
20Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.RCC Walls
21Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelReiforcement in BaseReinforcement of RCC Walls
22Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).Coarse ScreenWeight of SS Coarse Screen in - Kg/SqmMedium Screen Weight of SS Medium Screen in - Kg/SqmTotal Weight of Coarse & Medium Screen
23Construction of RCC Grit Chamber
24Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)RCC Walls
25Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.RCC Walls
26Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel Reiforcement in Base Reinforcement of RCC Walls
27Construction of RCC Primary Settling Tank
28Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
29Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
30Filling with sand including watering, ramming, consolidating and dressing complete.Sand Bed below CC bedFor FootingsFor walls
31Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC BedFor FootingsFor walls
32Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).FootingsPedestal For Base slab
33Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
34Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)For RCC walls Circuferance length
35Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Plinth BeamRoof Beam
36Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). For inspection track along the wall
37Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC BedFootingsPedestal
38Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.Plinth Beam BottomPlinth Beam Sides
39Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). For inspection track along the wallRoof BottomRoof Sides
40Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.For Base slab For RCC walls
41Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
426 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.inner side of the structure
43Applying Two coats of Corroseal Epoxy Resin based Coatingin one base coat and One top coats over the thoroughly prepared interiorsurfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of workAs per plastering Qty (Q)
44Providingand fixing of FRP Hand railings with Vertical Post of size 50 x 50x 5 mm speacing of at every 1000mm c/c with 1000mm height,andMiddle Tube 25mm x 30mm, Top rail of 65 x 45 mm. Resin Polymer +UV Grade with Hardware : SS304 (As Per design), Yellow color or other as per approved. Includingcost of all materials,fittings, machinery, labour, etc., finsished item of work as per direction of engineer incharge.on both sides of the inspection Walkway slab
45Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelBase slabWallsSlab
46Construction of RCC Bio Tower
47Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
48Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m % of the above Quantity.
49Filling with sand including watering, ramming, consolidating and dressing complete.Sand Bed below CC bedFor FootingsFor walls
50Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC BedFor FootingsFor walls
51Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).FootingsPedestal For Base slab
52Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
53Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)For RCC walls side length
54Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Grid Tie Beam Spacing @ 0.9m C/C at 1.2m heightRoof Beam
55Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). For inspection track along the Roof beam
56Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC BedFootingsPedestal
57Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.Grid Tie Beam Spacing @ 0.9m C/C at 1.2m heightRoof Beam BottomRoof Beam Sides
58Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). For inspection track along the Roof beamRoof BottomRoof Sides
59Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.For Base slab For RCC walls
60Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
616 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.inner side of the structure
62Applying Two coats of Corroseal Epoxy Resin based Coatingin one base coat and One top coats over the thoroughly prepared interiorsurfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of workAs per plastering Qty (Q)
63Providingand fixing of FRP Hand railings with Vertical Post of size 50 x 50x 5 mm speacing of at every 1000mm c/c with 1000mm height,andMiddle Tube 25mm x 30mm, Top rail of 65 x 45 mm. Resin Polymer +UV Grade with Hardware : SS304 (As Per design), Yellow color or other as per approved. Includingcost of all materials,fittings, machinery, labour, etc., finsished item of work as per direction of engineer incharge.on both sides of the inspection Walkway slab
64Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steelBase slabWallsSlab
65Construction of RCC Secondary Settling Tank
66Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
67Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
68Filling with sand including watering, ramming, consolidating and dressing complete.-Filling with sand including watering, ramming, consolidating and dressing complete.-Sand Bed below CC bed-For Footings-For walls
69Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed-For Footings-For walls
70Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Footings-Pedestal -For Base slab
71Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Columns upto GL-Columns Above GL
72Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-For RCC walls -Circuferance length
73Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Plinth Beam-Roof Beam
74Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).- For inspection track along the wall
75Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed-Footings-Pedestal
76Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-Plinth Beam Bottom-Plinth Beam Sides
77Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).- For inspection track along the wall-Roof Bottom-Roof Sides
78Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-For Base slab -For RCC walls
79Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
806 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.-inner side of the structure
81Applying Two coats of Corroseal Epoxy Resin based Coatingin one base coat and One top coats over the thoroughly prepared interiorsurfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of work-As per plastering Qty (Q)
82Providingand fixing of FRP Hand railings with Vertical Post of size 50 x 50x 5 mm speacing of at every 1000mm c/c with 1000mm height,andMiddle Tube 25mm x 30mm, Top rail of 65 x 45 mm. Resin Polymer +UV Grade with Hardware : SS304 (As Per design), Yellow color or other as per approved. Includingcost of all materials,fittings, machinery, labour, etc., finsished item of work as per direction of engineer incharge.-on both sides of the inspection Walkway slab
83Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-Base slab-Walls-Slab
84Construction of RCC channel for Fecal sludge collection Chamber Fine Screen & Medium Screen
85Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
86Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
87Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed for RCC drain
88Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed for RCC Drain
89Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Foundation Base Slab
90Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-RCC Walls
91Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed for RCC Drain-Foundation Base Slab
92Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-RCC Walls
93Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-Reiforcement in Base-Reinforcement of RCC Walls
9425 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).-Coarse Screen-Medium Screen
95Construction of RCC Fecal Sludge collection Chamber
96Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
97Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
98Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed for RCC Grit Chamber
99Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed for RCC Grit Chamber
100Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Foundation Base Slab
101Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-RCC Walls
102Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed for RCC Grit Chamber-Foundation Base Slab
103Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-RCC Walls
104Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-Reiforcement in Base-Reinforcement of RCC Walls
105Construction of Chlorination Tank
106Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
107Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -% of the above Quantity.
108Filling with sand including watering, ramming, consolidating and dressing complete.-Sand Bed below CC bed
109Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed
110Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-For Base slab
111Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-For RCC walls
112Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Top Slab-Deduct Manhole
113Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed-For Base slab -For RCC walls
114Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-For RCC walls
1156 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.-Intternal Platering-External Plastering
116Applying Two coats of Corroseal Epoxy Resin based Coatingin one base coat and One top coats over the thoroughly prepared interiorsurfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of work-As per plastering Qty (Q)
117Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new workto give an even shade.-External Painting above GL
118Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-For Base slab -For RCC walls -Top Slab
119Construction of Office Room of Size 5.5m x3.0m
120Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
121Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in Hard rocky soils
122Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
123Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in Hard rocky soils
124Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:a) Foundations and plinth-Columns Footings-for foundations of Basement-Flooring-Flooring of office room-Ramp portion
125Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Column footing.
126Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Pedastals
127Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Plinth Beam
128Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Columns up to 3.66 Mtsunsupported height above GL
129Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Lintals
130Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 ( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-RCC M20for Sun shades of 0.60M width, 75mm th. at fixed end and 50mm th. at free end
131Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Beams
132Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Slab - 125mm thick
133Coursed rubble masonry (first sort) with hard stone in foundations and plinth in cement mortar 1 : 6 (1 cement : 6 fine sand).-Ist Step below G.L(foundations)-2nd Step above GL(basement)
134Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).-Right round the building
135Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4coarse sand) in foundation and plinth.-Partiton wall-Parapet wall
1366 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).-to ceiling and bottom and sides of beams
13712 mm cement plaster 1 : 3 (1 cement : 3 fine sand).-Internal long walls-Internal short walls-Partiton wall
13815 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall.-External long walls-External short walls-Sun shades on both faces-both sides of the parapet wall
139Colour washing such as green, blue or buff on new work (two or more coats) including abase coat of white washing with lime to give an even shade.-Qtyas ceilingplastering-Qty as per Internal Plastering
140Colour washing such as green, blue or buff on new work (two or more coats) including abase coat or white washing with whiting to give an even shade.-Qtyas externalplastering
141Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone shingle 20mm nominal size) finished with a floating coat of neat cement.b) 50 mm thick-office room
142Entry / Exit Door Shutters :- Providing and fixing 37 mm thick factory made PVC Doorshutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) withinbuilt beading on one side, the styles and rails mitred cut and joint at corners byinserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with crosssection size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, railsand reinforcements to be fusion welded together. Only hinge side vertical style to beeinforced with PVC profile reinforcement in full length. Printed and laminated PVC lockrail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be weldedhorizontally with the vertical styles after inserting PVC profile reinforcement as in stylesand rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed &laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both sidethreaded and tightened with check nuts and washers complete, all as permanufacturer\"s specification and direction of engineer-in-charge.-Doors
143Window / Ventilator Shutters:- Providing and fixing factory made uPVC white colour casement/ casement cum fixed glazed windows comprising of uPVC multi chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges,zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners,mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)-Windows
144Providing precast cement concrete jali M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) reinforced with 1.6 mm dia mild steel wire including, roughening, cleaning, fixing and finishing in cement mortar 1 : 3 (1 cement : 3 fine sand) etc complete upto floor two level excluding plastering of the jams, sills and soffits.a) 50 mm thick-
145Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-Column footing.-Pedastals-Plinth Beam
146Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.-Columns up to GL-Columns aboveGL up to plinth beam top level-Columns aboveplinth beam top level to slab top level-Columns Aboveslab level
147Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-over windows-Roof Beams
148Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).-Roof Slab - 125mm thick
149Reinforcement of RCC work including bending, binding and placing in position complete.
150Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-Basement
151Providing and instalation of water supply & Sanitory to office room
152Providing and instalation of internal electrification
153Construction of Electrical Panel Room of Size 3.0m x3.0m
154Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
155Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in Hard rocky soils
156Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
157Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in Hard rocky soils
158Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shutteringin:a) Foundations and plinth-Columns Footings-Flooring
159Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Column footing.
160Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Pedastals
161Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Plinth Beam
162Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Columns up to 3.66 Mtsunsupported height above GL
163Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Lintals
164Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 ( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-RCC M20for Sun shades of 0.60M width, 75mm th. at fixed end and 50mm th. at free end
165Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Beams
166Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Slab - 125mm thick
167Coursed rubble masonry (first sort) with hard stone in foundations and plinth in cement mortar 1 : 6 (1 cement : 6 fine sand).-Ist Step below G.L(foundations)-2nd Step above GL(basement)
168Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).-Right round the building-for internal duct to Run the cable from Panel Board to generatorsets
169Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4coarse sand) in foundation and plinth.-Parapet wall
1706 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).-to ceiling and bottom and sides of beams
17112 mm cement plaster 1 : 3 (1 cement : 3 fine sand).-Internal long walls-Internal short walls-for Ducttop of bricks and Flooring of Duct (2x0.23)+(0.54)=1m-for Ductwalls
17215 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall.-External long walls-External short walls-Sun shades on both faces-both sides of the parapet wall
173Colour washing such as green, blue or buff on new work (two or more coats) including abase coat of white washing with lime to give an even shade.-Qtyas ceilingplastering-Qty as per Internal Plastering
174Colour washing such as green, blue or buff on new work (two or more coats) including abase coat or white washing with whiting to give an even shade.-Qtyas externalplastering
175Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone shingle 20mm nominal size) finished with a floating coat of neat cement.b) 50 mm thick-Generator room-Ramp portion-Deduct Duct portion
176Supplying and fixing rolling shutters of approved make, made of 80 x 1.25 mm MS laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of the top cover and spring. .-Doors
177Window / Ventilator Shutters:- Providing and fixing factory made uPVC white colour casement/ casement cum fixed glazed windows comprising of uPVC multi chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges,zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners,mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)-Windows
178Providing precast cement concrete jali M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) reinforced with 1.6 mm dia mild steel wire including, roughening, cleaning, fixing and finishing in cement mortar 1 : 3 (1 cement : 3 fine sand) etc complete upto floor two level excluding plastering of the jams, sills and soffits.a) 50 mm thick-
179Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-Column footing.-Pedastals-Plinth Beam
180Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.-Columns up to GL-Columns aboveGL up to plinth beam top level-Columns aboveplinth beam top level to slab top level-Columns Aboveslab level
181Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-over windows-Roof Beams
182Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).-Roof Slab - 125mm thick
183Reinforcement of RCC work including bending, binding and placing in position complete.
184Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-Basement
185Providing and instalation of internal electrification
186Providing and installation of Generator set
187Supply, Transportation, erection andcommissioning (Excluding Foundation) of 3 Phase, 415, 50Hz, water cooled multi cylinder diesel generator set with alternator of - - - KVA/ - - - - - KW out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete without control panel having IP-52 protection, Acoustic Enclosure as per CPCB norms , sound absorbing material,t to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB norms etc as per following specifications mentioned below. A. Alternator : Kirloskar / Stamford / Crompton Greaves / Leroy Somer make. The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21.B.DieselEngine:Kirloskar/Cummins/Mahindra& Mahindra Diesel Engine start, developing suitable -------------- BHP output at 1500 RPM withmechanical /electronic governing so as to enable the alternator to give- - - - -KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every11 Hrs of continuous runningat full load. The engine with 1st filling ofoiland Diesel etc. 01. Exhaust pipe of required size and length with insulation orclading. 02. Diesel tank suitable for 8 to 12 Hoursrunning capacity.03. ResidentialSilencer.04.SMFBatterieswithleadsaspertheManufacturer standards
188C. AMF Control Panel:- AMF control panel shall be fabricated with 16SWGCRCA sheet shall be totally enclosed with dust and Vermin proof, floor mounted / wall mounted type and shall be comprising the following.01. Voltmeter with selector switch.02. 4 Pole MCCB incomer of ----------A rating of Schenieder / L&T make for EB and DG.03. Ammeter with selector switch with CTs.04. PF Meter and frequency Meter.05. Indicator lamps (set Run, Load ON) with fuses.06. KWH Meter of required rating.07. Set of control fuses and current transformer.08. Input Terminal board and output Terminal Board.09. Battery charger with transformer rectifier unit.10. Alternator supply air break contactor of L&T make.11. Main supply air break contactor of L&T make.12. Audio Visual announciation.13. Main supply voltage set of control relays and timers with one mode selector switch, set of push buttons.14.Control cable up to 15 Mtrs 2.5Sqmm 6 Core
18915 KVA, 3 Phase, 415, 50Hz, 19BHP, water cooled multi cylinder diesel generator set with alternator of 15 KVA out put continous rating at 0.8 p.f, Batteries .15 KVA
190Supply of 185 Sqmm of 3.5core XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI /Finolex / Payal / RR kable / Beljin /Ollvin / Finecab / RPG / V - Guard / Orbit/ Fortune Arrt / Gemscab / Bonton / SPM/ Unistar / Windsor/Avocab / Pawancab/ Nakoda / Suncab
191Earth work excavation in all soils, laying of UG cables from 70 Sqmm to 400 Sqmm on sand cussion, covering the cable with bricks and back filling the trench duly providing route indicator embedded in CC including cost and conveyance of all material and all labour charges etc, complete.
192Filling with sand including watering, ramming, consolidating and dressing complete.-BelowBed Concrete
193Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-for foundation of Generator bed
194Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth-for Generator bed
195Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel-at 35Kg/ 1 Cum
196Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.-Earthing
197Leveling of site by cutting and filling of earth
198Earth work in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layers and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 50 m and lift upto 1.50 m.
199Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Details of cost for 10 Cu.m
200Supply, Delivery, Installation Testing of Pumps Sets at Bio Tower
201SUBMERSIBLE SEWAGE NON-CLOG VERTICAL PUMPSupply, delivery, installation, testing and commissioning of Submersible sewage, Non clog vertical type pump suitable for working on Air filled Dry type motor, three phase, 50 Hz +/-3%, 415V +/- 10%, AC supply, 1500 RPM synchronous speed with 3 core flat copper cable from pump to starter panel with cable end terminations (4) all supports, clamps, pipe fittings along with mechanical seal, bearing bush, strainer, arrangements for lifting for maintenance, guide pipes etc. complete set & following M.O.C: Casing CI, SS CF8M impeller, Bronze: wearing ring & Bearing bush, TC mechanical seal, CS/S.S. bearing, S.S shaft with sleeve, SS strainer & MS motor body,including compatible panel board consisting ofAuto Transformer Starter suitable for local & remote pump control application consisting of Auto Transformer (vacuum impregnated, air cooled having three (3) tappings at 50%, 65% and 80%), incomer MCCB / MPCB, overload relay and contactors as per Type II coordination including digital MFM with RS 485 communication port, analogue type ammeter with selector switch, run hour meter, required protective relays & control accessories.STANDARD ACCESSORIESSupply, Delivery and Installation of Standard accessories including Power cable of PVC+Cu length 5mtrs, Pedestal auto rail coupling of Cast Iron(CI),Single Rail GR pipe of SS304 length 10Mtr and along with GRP coupler, Lifting chain with bow shackles and control panel including auto transformer starter Including Suction pipe dilavery pipe up to manifold sutuable Valves ,NRV,Pressure Gauge,Manifold etc.
202For Recirculation
203Inlet to Bio tower
204Supply and Delivery of HDPE tank including installation on gound
205Providing Filter Media at Bio Tower with sprinkling system, piping arrangements including valves, Bends, Tees etc complete item of work
206Construction of Wet well of 2m dia and 6.5m depth
207Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils
208Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty-EWE from 3 to 6 metres by Mechanical means
209Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty-EWE from above 6 metres by Mechanical means
210Filling with sand including watering, ramming, consolidating and dressing complete.-For WET WELL (π/4x3.4^2)
211Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-For WET WELL (π/4x3.4^2)
212Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Base Slab
213Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-1st Step 0.4m Sidewalls of WET WELL (πx2.4) Below Ground
214Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Sidewalls from 5.5 to 4.5m Below GL
215Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-2nd Step 0.3m Sidewalls of WET WELL (πx2.3) Below Ground
216Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Sidewalls from 3.5 to 2.5m Below GL
217Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-3rd Step 0.2m Sidewalls of WET WELL (πx2.2) Below Ground
218Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Floor level Beams at +1.0m
219Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-Floor Roof Slab 150 thick @1.0m Height ( Half of the Dia)
220Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-PCC Below Base Slab-For WET WELL (π/4x3.4^2)
221Extra for shuttering in circular work. -Add 20% of the rate of respective item of centring and shuttering.
2223rd Step 0.2m Sidewalls of WET WELL (πx2.2) Below Ground-1st Step 0.4m Sidewalls of WET WELL (πx2.4) Below Ground-2nd Step 0.3m Sidewalls of WET WELL (πx2.3) Below Ground-3rd Step 0.2m Sidewalls of WET WELL (πx2.2) Below Ground
223Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
224Centring and shuttering including strutting, propping etc and removal of form work for c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).-Floor Roof Slab 150 thick @1.0m Height ( Half of the Dia)-For WET WELL (π/4x2.8^2)-For Slab Sides
225Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-Floor level Beams at +1.0m- B1 (300x450)
226Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel
2276 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams.-Internal Plastering-External Plastering above GL
228Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering.
229Applying Two coats of Corroseal Epoxy Resin based Coatingin one base coat and One top coats over the thoroughly prepared interiorsurfaces as directed by departmental officers, with each coat not exceeding 60 microns in dry film thickness and total film thickness to 240 microns including cost and conveyance of all materials to site, all labour charges ,curing and all other incidental charges etc complete for finished item of work-As per plastering Qty (Q)
230Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new workto give an even shade.-External Painting above GL
231Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works-for Lader
232Construction of I&D Structures
233Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.)-Girth from 300 mm to 600 mm
234Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.)-Girth from 600 mm to 900 mm
235Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.)-Girth from 900 mm to 1800 mm
236Demolishing brick work in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.-Dismantling of existing structure
237Demolishing RCC work including stacking of steel bars and disposal of un-serviceable materials within 50 metres lead.-CC Walls, beds etc,.
238Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils for footings
239Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
240Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed for RCC drain
241Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed below foundation
242Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Foundation Base Slab-Weir
243Reinforced cement concrete in walls (any thickness) including attached pillasters,buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)-RCC Walls
244Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed below foundation-Foundation Base Slab
245Centring and shuttering including strutting, propping etc and removal of form work for b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.-Weir-RCC Walls
246Reinforcement of RCC work including bending, binding and placing in positioncomplete.b) Tar/TMT steel-Reiforcement in Base-Reinforcement of RCC Walls
24725 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).-Coarse Screen-Medium Screen
248Construction of elevated RCC Bridge with RCC NP2 Pipe
249Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -in all types of soils for footings
250Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m -10% of the Total Qty
251Filling with sand including watering, ramming, consolidating and dressing complete.-Below CC bed
252Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.-CC Bed
253Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Footings
254Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Pedastal
255Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Columns upto GL-Columns Above GL
256Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Beam
257Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).-Roof Slab
258Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete-CC Bed -Footings-Pedastal
259Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.-Columns upto GL-Columns Above GL
260Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc.-Roof Beam-Roof Beam Bottom-Roof Beam Sides
261Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).-Roof Slab-Roof Bottom-Roof Sides
262Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel
263Providing and Layng light duty non-pressure NP2 Class RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement : 2 fine sand) including testing joints etc complete.-250mm dia RCC Pipe (NP2)
264Providing and Layng light duty non-pressure NP2 Class RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement : 2 fine sand) including testing joints etc complete.-300mm dia RCC Pipe (NP2)
265Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.-Manhole Chamber
266Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works-MS Flat for Anchoring
267Internal & External electrification with Transformer
268Fabrication and Supply of M.S. Poles for garden posts with \"B\" class 6 mtrs long 60.25mm outer dia with base plate and suitable pole cap including cost and conveyance of all material including fixing of luminaire and labour charges etc., complete. 6Mtrs \"B\" Class M.S. pipe of 60.25mm dia with base plate and suitable pole cap
269Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
270Supplying and drawing (following size) of FRLS PVC insulated copper conductor single core cable in existing surface / I recessed steel /PVC conduit as required.
271Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required.
272Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
273Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 A TP&N
274Providing and fixings 4 pole MCCB 100 amp. 16 KA in existing cubicle panel board including drilling holes in cubicle panel & making connection etc. as reqd.
275Earthing with G.I. earth pipe 4.5m long 40mm dia i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or cokeL and salt) as read.
276Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
277Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.1 output per phase and suitable for single phase supply
278New generation energy saving andenvironmental friendly long life LED street light made up of pressure die castaluminum housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07.70 W LED
279Providing of 10mmsqm 2-core& 6mmsqm 2-core PVC/XLPE Cables,Indicating Lamp,Voltmeter range 0-500 volts,Ammeter range 0-200 volts,Current transformer coil range 0-200 amp,Hinges for panel door,Panel door locksSelector switch for ammeter & voltmeter etc
280Erection of 25 KVA Transformer
281Providing and installation of Porta Cabin for Security Room
282Supplying and installation of MS Fabricated Portable Cabin With complete insulation, electrical & Plywood claddings etc, complete as per direction engineer incharge with followingTechnical Specifications: Portable Security Cabin ( both side finish ) Material- MS, ACP & particle Bord. Size – 6 Ft x 6 Ft Height– 7Ft Colour – White & Blue Aluminum Sliding Window -2 NosDoor – 1 NosElectrical Switch Socket Board – 1 NosTechnical Specification1) 18 mmcement Boardfor floor2) 1mm MS sheet for outer3) 9mm Particle Board for interior4) 50 x 50 mm MS pipe structure 5) 40 x 20 mm MS Pipe 6) 1mm PVC carpet on floor7) Internal electrical fitting
283Providing 3.5m wide CC Road with 1m earthen shoulders on either side
284Excavation in Soil using Hydraulic Excavator CK 90 and Tippers with disposal upto 1000 metres. (Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers,trimming bottom and side slopes, in accordance with requirements of lines,grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m)-EWE in ordinary soils- total Qty
285Construction of Embankment with Material Deposited from Roadway Cutting (Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)-for formation of road 90% total Qty
286Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)-for formation of road
287Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) for grading- IMaterial-for the formation of new road
288Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
289Cement Concrete Pavement (Construction of un-reinforced, dowel jointed,plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383,maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, for M40 Grade having minimum 28 days flexural strength of 4.5 Mpa, using approved admixtures, transported to site, laid with a fixed form or slip form paver,spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip,dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing. )
290Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)
291Construction of Compound wall with Chain Link Fencing and MS Gate
292Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m in all types of soils for footings
293Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m 10% of the Total Qty
294Filling with sand including watering, ramming, consolidating and dressing complete.Below CC bed
295Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC Bed
296Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Footings
297Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Pedastal
298Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL
299Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concreteCC Bed FootingsPedastal
300Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc.Columns upto GLColumns Above GL
301Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel Footings Pedastal Columns upto GLColumns Above GL
302Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksfor MS Gate
303Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.for foundations of MS fencing posts - Mainfor foundations of MS fencing posts - Inclined support at every 30m
304Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.for foundations of MS fencing posts - Mainfor foundations of MS fencing posts - Inclined support at every 30m
305Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).for foundations of MS fencing posts - Mainfor foundations of MS fencing posts - Inclined support at every 30m
3061.20 m high welded steel wire fencing with 1.80 m RCC posts of standard design placed at every 3 m apart embedded in cement concrete blocks 45 x 45 x 60 cm of mix 1 : 5 : 10(1 cement : 5 fine sand : 10 stone aggt. 40 mm nominal size), corner end and every 10th post to be strutted and embedded in cement concrete blocks of 70 x 45 x 50 cm of same mix provided with welded steel wire fabric 0.90 m wide, rectangular mesh 75 x 25 mm size weighing not less than 7.75 kg per Sq.m. fixed between the two posts fitted and fixed with GI staples on wooden plugs or tied to 6 mm bar nibs with binding wire including earth work in excavation, concrete work and cost of posts, struts etc complete.Area as per the Drawing- Longitudinal length x Height
307Supply, Delivery, Installation, Testing of Pumps Sets at Wet well 20KW-2Nos (1 Working 1 Standby)
308SUBMERSIBLE SEWAGE NON-CLOG VERTICAL PUMPSupply, delivery, installation, testing and commissioning of Submersible sewage, Non clog vertical type pump suitable for working on Air filled Dry type motor, three phase, 50 Hz +/-3%, 415V +/- 10%, AC supply, 1500 RPM synchronous speed with 3 core flat copper cable from pump to starter panel with cable end terminations (4) all supports, clamps, pipe fittings along with mechanical seal, bearing bush, strainer, arrangements for lifting for maintenance, guide pipes etc. complete set & following M.O.C: Casing CI, SS CF8M impeller, Bronze: wearing ring & Bearing bush, TC mechanical seal, CS/S.S. bearing, S.S shaft with sleeve, SS strainer & MS motor body,including compatible panel board consisting ofAuto Transformer Starter suitable for local & remote pump control application consisting of Auto Transformer (vacuum impregnated, air cooled having three (3) tappings at 50%, 65% and 80%), incomer MCCB / MPCB, overload relay and contactors as per Type II coordination including digital MFM with RS 485 communication port, analogue type ammeter with selector switch, run hour meter, required protective relays & control accessories.STANDARD ACCESSORIESSupply, Delivery and Installation of Standard accessories including Power cable of PVC+Cu length 5mtrs, Pedestal auto rail coupling of Cast Iron(CI),Single Rail GR pipe of SS304 length 10Mtr and along with GRP coupler, Lifting chain with bow shackles and control panel including auto transformer starter Including Suction pipe dilavery pipe up to manifold sutuable Valves ,NRV,Pressure Gauge,Manifold etc. Total Head 18m
309Add Carriage Charge
310Add 5 years (Operational & Maintenance) cost

AI Tender Summary

OUR REF NO 49804448
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 07-07-2025
Authority
Authority Name Urban Development And Housing Department
Work Description Construction Of Sewage Treatment Plant (Stp) In Bomdila In West Kameng, A.P
Basic Detail
Tender No EE/BUD/W-21/2024-25
Bidding Type Tender
Location
City West kameng
State Arunachal Pradesh
Key Dates
Publish Date 23 Jun 2025
Submission Date 07 Jul 2025
Open Date 07 Jul 2025
Finance
Tender Value Ref. Documents
Tender Fee 10000
EMD 7.11 Lakhs
Exemption Not Available
Document List
2bf1d646-46a3-4d59-be4e-af9a5a974b38.html
STP_BDL.pdf
Tendernotice_1.pdf
BOQ_2791.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 23, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 07, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 07, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

2bf1d646-46a3-4d59-be4e-af9a5a974b38.html

pdf

STP_BDL.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_2791.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender