}

Tender For Sitc Of 3-Phase 500 Kva Digital Micro Controlled Servo Stabilizer At Bakhira Pump Canal-Ii - Sitc Of 500 Kva ( Including Fabrication Of Tinshade And Foundation For Scvs), Free-Standing Floor Mounting, Outdoor Type, Copper-Bound Servo-Controlled, gorakhpur-Uttar Pradesh

Irrigation Department has published Tender For Sitc Of 3-Phase 500 Kva Digital Micro Controlled Servo Stabilizer At Bakhira Pump Canal-Ii - Sitc Of 500 Kva ( Including Fabrication Of Tinshade And Foundation For Scvs), Free-Standing Floor Mounting, Outdoor Type, Copper-Bound Servo-Controlled. Submission Date for this Tender is 07-07-2025. Voltage Stabiliser Tenders in gorakhpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

49795197
Tender For Sitc Of 3-Phase 500 Kva Digital Micro Controlled Servo Stabilizer At Bakhira Pump Canal-Ii - Sitc Of 500 Kva ( Including Fabrication Of Tinshade And Foundation For Scvs), Free-Standing Floor Mounting, Outdoor Type, Copper-Bound Servo-Controlled
Tender
Indian
Uttar Pradesh
Gorakhpur
07-07-2025

Tender Documents

Tender Details

Tender For Sitc Of 3-Phase 500 Kva Digital Micro Controlled Servo Stabilizer At Bakhira Pump Canal-Ii - SITC of 500 KVA ( including fabrication of tinshade and foundation for SCVS), free-standing floor mounting, outdoor type, copper-bound servo-controlled voltage stabilizer (SCVS), naturally oil cooled (including first filling of oil), suitable for voltage range of input phase voltage (voltage range 150-260 volt, i.e, 230 Volt), should be maintained at 230 volt 1% with a speed of correction not less than 7-8 v/sec—phase to neutral voltage. The SCVS shall have an output voltage range of 415-440 volts and shall be supplied with a Digital voltmeter and ammeter with a selector switch to read input/output voltage and currents. Auto/manual control selector switch, sensitivity control LED indication lamps within fuses and controls, and protection against OVER/UNDER voltages. OVERLOAD, Single phasing, and protection for sensing elements. SCVS shall have all accessories like cable and boxes, oil gauge, silica gel breather,earthing terminal, and complete as required. The SCVS shall conform to IS: 9815 (with the latest amendment). The SCVS shall be suitable for unbalanced loads and unbalanced input voltage with individual correction in all three phases. The SCVS shall be provided with the following protection: Overload, Short Circuit, Earth fault, Over voltage, Under voltage, Single phase prevention, High Temperature Spike, and Surge CONTROL AND Indication. The following alarm and annunciation shall be provided: Alarm 1, Low/High voltage (out of input range) 2. Single-phase prevention alarm, 3. High temperature alarm indication, LED indication for input voltage, High/Low DEGREE OF PROTECTION: The Degree of protection for the enclosure shall be IP65 for an outdoor installation. COOLING METHOD: The Cooling method shall be oil-cooled. TESTS: All routine tests as per standards shall be conducted for proper functioning of the Equipment in the presence of a Departmental representative. Note: The Firm will be responsible for maintenance, including the cost of spare parts, labour, and T&P for 2 years from the date of completion of work.Installation structure for SCVS (including all cast of material and T&P) (A) E/Work for in canal embankment/ Marginal embankment/ flood embankment /flood work/ Trenches with its proper disposal & their dressing within 30 meter lead & 1.5 mtr lift i/c refilling the trenchetc. (0.6 Cum)(B)Cement Concrete 1:4:8 with 40 mm gauge brick ballast, cement, and coarse sand in the foundation.(1.5 Cum)(C) Brick Work in 1:4 C.M. (0.90 Cum)(D) C.C 1:1.5:3 with chopan coarse sand F.M <2 andCrushed coarse aggregate 4.75 to 20 mm. / cum.(1.70 Cum) (E) 12mm thick plaster in 1:4 CM with coarse sand.(2.00 Sqm)(F) fabrication of MS gate, door, window & ventilators.(690 Kg)(G) M.S.Roof truss work with 60x60x4 mm ms sq. tube @6.71kg/mtr ( 318 Kg)(H)providing of iron roofing 0.8mm thick fixed with iron J or I hook bolts 08 mm dia with Bitumen and GI limpet washer or with GI limpet washers filled with white lead and including a coat of approved steel primer and two coat of approved paint on overlapping of steel complite up to pitch of 600 and excluding the cost of purlin rafter and truses for class of sheet(12.24 Sqm) (I) Applying priming over new steel and metal surface i/c material, labour & T&P. (33 Sqm)(J) Painting first coat over priming coat on steel work.(33 Sqm)As per the direction of Engineer -in- Charge at the site.

Key Value

Document Fees
INR 854 /-
EMD
INR 35000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail