}

Work Of Turfing Of Switch Yard, Plinth Repairing Of Power T/FS & Repairing Of Cable Trench At 33/11 Kv S/S Itbt Under Edsd Gadarpur Under Electricity Distribution Division, Rudrapur-Ii Under The Head O&M.(Rates Quoted Without Gst) (Gst Will Paid Extra), rudrapur-Uttarakhand

Uttarakhand Power Corporation Limited has published Work Of Turfing Of Switch Yard, Plinth Repairing Of Power T/FS & Repairing Of Cable Trench At 33/11 Kv S/S Itbt Under Edsd Gadarpur Under Electricity Distribution Division, Rudrapur-Ii Under The Head O&M.(Rates Quoted Without Gst) (Gst Will Paid Extra). Submission Date for this Tender is 08-07-2025. Switch Yard Tenders in rudrapur Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

49795125
Work Of Turfing Of Switch Yard, Plinth Repairing Of Power T/FS & Repairing Of Cable Trench At 33/11 Kv S/S Itbt Under Edsd Gadarpur Under Electricity Distribution Division, Rudrapur-Ii Under The Head O&M.(Rates Quoted Without Gst) (Gst Will Paid Extra)
Tender
Indian
Uttarakhand
Rudrapur
08-07-2025

Tender Documents

Tender Details

Work of Turfing of Switch Yard, Plinth repairing of power T/Fs & Repairing of Cable Trench at 33/11 KV S/s ITBT under EDSD Gadarpur under Electricity Distribution Division, Rudrapur-II under the head O&M.(Rates Quoted without GST) (GST will paid extra)= 1 Annexure -A ( Works ) 2 Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth andsludge or manure and mixing excluded) 3 Earth filling under floor and in sub-station area including cost of earth. Earth to be obtained from outside the corporation area including its cartage and ramming, watering, dressing in 20 cms thick layers including cost of earth with all lead and lift etc. 4 Providing and fixing 35mm x 6mm G.I strip on surface or in recess for connections etc. As required. 5 Providing of Gravel & spreading in switch yard area with 20mm nominal size in required thickness as directed by Engineer-In-Charge. 6 Excavation in Soil in Hilly Area/River Bed by Mechanical means i.e. backhole loader. 7 Cleaning, Dressing and labling of Switch yard and carry out from yard to out side. 8 Earth Work in Excavation by Mechnical means/ manual means over areas CC/Hardrock. 9 Providing and Laying in position cement concrete of specified grade excluding the cost of centering and shuttering- all works upto plinth level 1:4:8 (1-Cement; 4-Coarse sand and 8-Graded Stone agrregate 40 MM nominal size) (For Foundation, Footings, Bases of columns etc for Mass Concrete). 10 Providing and Laying in position cement concrete of specified grade excluding the cost of centering and shuttering- 1:2:4 (1-Cement; 2-Coarse sand and 4-Graded Stone agrregate 20 MM nominal size) (For Road Repairing/Other work). 11 Providing and Laying in position specified grade of Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All works upto plinth level (I) 1:1.5:3 (1-Cement; 1.5-Coarse sand and 3-Graded Stone agrregate 20 MM nominal size)(For Road Repairing/Other work). 12 Brick work with common burnt clap bricks with cement mortar 1:4. 13 Cement Plaster work as per direction of Engineer in charge. 14 Making of foundation and cable trench for 990 KVA CSS. 15 Earthing of distribution transformer including digging of pit of size 2.5 Mtr depth and make hole of size 150 mm. Placing of earthing electrode (to be supplied by contractor), connecting the same with G.I.Strip (to be supplied by contractor) of size 35x6 mmfor a minimum length 6 m. treatment of soil with highly condctive substance as per IS 30343 complete in all respect, result of earthing resistance to be recroded in M.B. before and after installation of earthing. Theearth resistance after earthing should be less than 1 Ohm. 16 Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod to proper depth and connecting the earth electrode with the help of G.I. wire as per construction manual. 17 Painting of yard Isolator/LA/CT/Structure complete. 18 Cement Plaster on DTR Plinth side walls in 1:4 ratio 19 Mounting and Fixing of Lightning arrestor set (3 Nos.) on double pole structure including making allconnections by G.I. strip size35x6 mm to earth point complete work (excluding cost of G.I.Strip) 20 Cartage of the 33/11 CT/PT/Isolator from store center to construction site with loading and unloading at both points.(Distance 21-50 Km) 21 Erection of (8,5) MVA T/F at transformer plinth & erection of all accessories i.e. radiators, conservator tank, vent pipee etc., with the help of special type of T&P / crane etc. fitting cable etc. and refilling the fresh oil in radiator and conservator. 22 Excavation of earth for erection of structure (2x1.1x0.3x0.3) 23 Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. 24 Earthing of G.I. Pipe Pole dia 1.5 Inch (Length 18-20 Feet) by M.S. Earthing Rod 20x250 mm 25 Fixing of 33 KV line Isolator Vertical type on ST Pole. 26 Installation of 33 KVCT PT combined unit. 27 Fabrication of MS Channel Angle Iron etc. for making T/F Base, in requried sizes with drilling of holes upto good finish of top channel, bracing and special type bracket etc as per RESPO schedule as per direction of Engineer in charge. 28 Laying of Control cable of all sizes through trench, proper connection at both ends outside in switchyard equipments and inside control room in VCB, control and relay Panels with proper marking, lugs , labelling and ferrules etc 29 Painting of Transformer as per direction of Engineer in charge. 30 Repair work of damage Control cable trench cover. 31 Work of fixing jaal as the top of the surface of cement, concrete after maintaining earthing cover of the ground. 32 Providing and Spreading of 7mm to 20mm dia round Size of gravel stone in out door switch yard in depth 50mm. 33 Repairing of old damaged trench including fabrication, fixing of MS angle 50/40X6 mm size (excluding cost of MS angle/ MS bar) on side edge with all excavation, CC work, brick work, fixing of cable support angle one/two tier as required with stopper arrangement at 0.5 mtr gap throughout the length of the trench, making of cable trench covers with MS Bar welded mesh angle frame with lifting hooks, fixing of perforated tray complete including cost of sand, cement, bricks, metal etc. as per direction of Engineer in charge. 34 Annexure - B ( Supply ) 35 Supply of 33 KV Isolator Conn. Clamp for Panther with N&B 36 Supply of Bolts & Nuts off size 37 Supply of PG Clamp ACSR Panther to ACSR Dog 38 Supply of PG Clamp for Panther 39 Supply of GI Strip 50x6 mm 40 Supply of Earth Electrode 41 Supply of Connector Suitable Panther for VCB

Key Value

Document Fees
INR 2360 /-
EMD
INR 98000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail