Restoration And Provision Of Medical Equipment For The Polyclinic At The Academy Of Armed Forces, Tashkent, Uzbekistan; 1. Labomed Microscope •Microscope Type - Pathological binocular non hinged type with built in light and with light intensity regulator. •Eye piece Type - Compensating. •Eye Piece with magnification – Set of Two For Binocular 10x •Objective Type - achromatic. • Objective Magnification - 10 x • Numerical Aperture of Objective - 1.25. •Warranty - 5 year 1 Set (one Set ) 2. Semiautomatic optical coagulomet er Semi–automatic desktop coagulometer with one optical channel. Should be able to determine prothrombin time (PV), activated partial thromboplastin time (APTT), fibrinogen concentration, D-dimer concentration and clotting time. The device should allow to perform qualitative and quantitative measurements and should enable the automatic registration of the time of clot formation. Should have Low reaction volume of 150 μ and Incubation count down with alarm 1 Set (one Set ) 3. 2 Channel Real-time PCR cycler Light Source:- LED, Detector:- PMT Tubes, System should offer 2 Channels + HRM Channel, Open system for all available real- time chemistries including SYBR Green, dual-labelled and MGB probes, FRET probes and Molecular Beacons, System should work with air based technology and should offer sample range from 36 & 72 Format, Reaction volume:- 10 to 50 Microliter. System should be open system for Plasticware (0.2ml and 0.1ml Strip tubes Tubes), Passive Reference: - System should not require any passive reference dyes (like ROX) or software colour compensation, Software must have In-built Analysis Modes: - Standard curve quantification, Relative quantification by 2 standard curves, relative quantification, Comparative quantification, Melt analysis, HRM analysis, End-point analysis, Allelic discrimination, Scatter plot analysis, Concentration analysis, Thermal Uniformity of the system: -System Should have Temperature uniformity (well to well variation) :- should be minimal ideally around ±0.01°C, Temperature accuracy (difference between programmed and actual temperature inside tube):- should be minimal ideally around ±0.25°C, Temperature resolution: - should be minimal ideally around ±0.02°C, Temperature equilibration time: - Minimal, ideally Zero seconds, Ramp Rate: - >10°C/second heating; >10°C/second cooling, Software should have unlimited user licenses and individual user management and should be as per MIQE 1 Set (one Set) 4. Clinical Chemistry Analyser (Semi Automatic Biochemistry analyzer) • User Interface - Mechanical Key board. • Flow Cell Type - Permanent Flow Cell • Wavelength Section & Measurement range (wavelength). Interference filters with minimum 06 filters covering standard wavelength in the range of 340 to 670nm in order to analyse serum and plasma glucose, urea, creatinine, uric acid, cholesterol, bilirubin, protein, albumin, AST, ALT, ALP, GGT, CPK, CKMB, Amylase, LDH & microprotein in CSF and urine, PT & APTT in coagulation tests. • Should have halogen light source. • Absorbance range0 to 3 unit. • Measurement Range (temperature). 25,30,37 degree Celsius with 1 degree increment peltier. 1 Set (one Set) • Memory of storing test results, sufficient for : 200 test results and 5000 patient results. • Heat Dissipation ability : Analyzer shall maintain nominal temperature, with suitable heat dissipation/cooling mechanism. • Number of programmable channels for chemistries: 100 to 200 • Assay/Calculation types available in analyzer : End point with factor or standard , Fixed time with factor or standard, Kinetic; Enzyme kinetics with factor or standard, Absorbance, Sample blanking, Differential mode with factor of standard, coagulation tests. • Calibration types available : Linear factor, Multi Point, Point to Point, Log-Logit, Spline, 1-point calibration, 2-point calibration, Polygonal Multi standard (Calibration Curve). • 3 level control facility with day to day Levy-Jennings curve stored and displayed to be available. • Flow cell material: Quartz. • Flow cell volume (Minimum): 18 microliter • Flow cell optical Path : 10mm • Flow cell washing system should be available • Aspiration volume :200- 1000 microliter • Power Source: Compatible with electric power from by 220V-240V 50Hz(+/-10%) AC source • Power back up with provision of UPS (with maintenance free batteries) for each equipment under: Open system. • Operating & Storage Conditions: The equipment Should be suitable for operating continuously in ambient room temperature of 8 degree C to 37 degree C and relative humidity of 15 to 90% • Part of the Device that are designed to come into contact with the patient sample or the operator should be suitable for easy disinfection. • Printer Facility: Yes, in-built Thermal Printer with printer roll (1 dozen to be provided). • Computer interface: By RS232 port/USB/HDMI port facility USB interface for PC or external printer • Certification available for the product : CE Europe 5. Automatic urine analysis system. Machine should analyse both sediment and chemical parameters simultaneously in the sample The machine should be able to Report following parameters: RBC, WBC, WBCC, BACT, YST, EC, SRC, CRYS, HYAC, UNCC, MUC. Phase parameters RUO and RBC:POl. Chemical parameters: GLU, PRO, BLD, BIL, pH, KETVitC, URO, NIT, LEU. 11/14 reporting parameters with HS-11/HS-14 strips. Bandwidth. Hybrid mode/Element mode: >40 t/h, should be able to download 200 strips samples. Should have LAN port. Sample Loading 50 samples with Sample Volume Hybrid mode: 1.25 mL Formed Element mode: 1 mL Chemistry mode: 0.75 mL 1 Set (one Set) 6. Semiautomatic hematology analyzer The machine should be compact and suitable for standard general blood tests, It should be able to monitor: leukocytes with differentiation into 3 subpopulations (monocytes, lymphocytes, granulocytes) (% and #); red blood cells; hemoglobin; hematocrit; average volume of red blood cells; SGE (average hemoglobin concentration in erythrocyte); width of erythrocyte distribution; platelets; average platelet volume; thrombocrit; anisocytosis of erythrocytes; Throughput 30 samples per hour, Color LCD display Resolution: 800 x 600, Automatic clog removal and recount function 1 Set (one Set) 7. Laboratory refrigerator Should have uniform storage temperature for storage of pharmaceuticals, medicines, vaccines, and other temperature-sensitive applications. Volume 165 litters, temperature range +2 to +14 degrees Celsius. Should have minimum 3 wire shelves with 20 Kg load taking capacity of each shelf. Should have built in LED light. 1 Set (one Set) 8. Ultraportable Light Weight USG Scanner with Colour Doppler • The equipment should be a high performance unit capable of supporting convex and linear probe. • Display mode should include B mode, M-Mode, Colour and pulse wave doppler. Control Panel and software • Should have alphanumeric keyboard, electronic track ball or equivalent control. • The knobs, buttons and controls should be user friendly and ergonomically positioned. • Should provide multiple Pre and Post processing functions. • It should have gay scale. • Magnification of image should be possible. • Standard measurements such as distance, circumference area and volume should be possible. • A DVD/hard drive based image encyclopedia for training purpose should also be provided. Onsite training should also be provided. • Should have facility for either DVD or USB transfer of data. • Frame rate of >100 frames / sec • It should have 2 probes (7-9 Hz probe and 3-5 hz probe) General points • Display Monitor Integrated 15 inches or more, wide angle LCD screen. • The weight of ultrasound machine should be less than 10Kg in weight. • System should have a built in battery backup system with minimum 45 minutes backup facility. • The equipment should be mounted on an argonomically designed, height adjustable mobile trolley. • The system complete with probe and accessories Including battery and power adapter will be provided • An up time of 95% is to be ensure during the warranty period. • The system should have US FDA/ EU CE approval. 1 Set (one Set) 9. Portable Digital X-ray Machine Portable continuous operations X-ray machine should provide excellent image quality for diagnosing all parts of the human body, including the group. cage, pelvis, stomach, arms, legs for adults and children while having low exposure radiation. The setup time should be less than 1 minute and image accusation time should be less than 3 seconds. It should have adjustable active area collimator and with reduces leakage and scatter radiation. Should have Tube kV/mA 40~70 kV / 2~6 mA , Focal spot of 0.4 mm. Power output: 420 W, Power input: 100-240 VA - 50/60 Hz, 1.5 A, Rechargeable battery: DC 22.2 V / 1.800 mAh, Size - Weight: 165.3x176x255.6 mm - 2.4 kg, Protection: Class II, type B. Should have LED and laser guided Beam function to help users to identify accurate exposure area. 1 Set (one Set) 10. Portable dental x-ray kit The portable x-ray machine should be operatable by one hand and should weigh not more than 1.5 Kg. The built in battery should be Li-polymer 22.2 VDC, 1,000 mAh and system should have sleep mode to conserve battery. The system should have 0.4 mm focal spot 1 Set (one Set) ..... more in document