| 1 | Supply & errect Steel Tubular Swaged Poles Type 410-SP-22 (8.5 Metre long) complete with cast iron base plate, finial taper plug, cap, mild steel bolts, screws, etc. including applying two coats of black bituminous paint internally and externally upto planting depth and applying alternative black and white strips of 30 cm width upto 1.5m above ground level and applying two coats of aluminium paint over a coat of red oxide primer (externally from top of PCC copping) including writting MES Pole No. with synthetic enamel paint (first grade quality) complete all as specified and directed.Note:-(a) Earthwork and PCC will be measured and paid under relevant items in this BOQ.(b) Volume occupied by Steel Pole shall be deducted to derive the quantity of PCC. |
| 2 | S & F LED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 4900 lm and system wattage not less than 35W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. |
| 3 | The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2.The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including with necessary brackets / pipes clamps & nuts & bolts for holding the street light fitting and three core copper flexible cable of 1.5 Sqmm as required at site complete all as directed. |
| 4 | Supply & installation of Galvanized Steel High Mast lighting system for 16 meter hight mast in two shafts with 20 sided polygon cross section (top 166 mm & bottom 410 mm bore min) and sheet thickness 3mm for top & 4mm for bottom (min), hot dip galvanised (confirming to IS 4270)and suitable for wind velocity as per IS 875, Part-III with all it\"s standard accessories including head frame, luminaries carriage size of base plate should be Suitable to install 09 Nos 120 Watt light fittings and double drum winch with 3 Nos steel wire rope system of min 6 mm dia, 4.0 sqmm 6 core trailing cable with copper conductor, connectors, integral power tool motor of suitable capacity with rising/lowering mannual system comprising of handle, junction box, lightning, anchoring, foundation bolts size M24 X 1200 mm, Aviation Obstruction Light (AOL) fixing arrangement and other accessories.Note: (i) (Rates of Excavation, RCC foundation as per the approved design of OEM are exclusive of above item which will be measured and paid separetly). (ii) Material Specifications a)Mast & pole shaft- BSEN 10025, ASTM A572, IS 5986 b)Foundation : IS 2062/E250Ac)Base Plate : IS 2062 d)Galvanisation : IS:4759/2629 & ASTM A123 |
| 5 | S & F LED based Flood light, housing made up of pressure die cast aluminium Alloy with of pressure die cast aluminium Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 120 lumen/ Watt and a minimum system lumen output of 14400 lumens and minimum system wattage of 120 Watts. The LEDs used shall be 50000 Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07. The fixture driver should have an operating voltage range of 140-270 V, In - built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminair shall have 10 KV SPD bolted inside the luminaire. The luminaire driver & SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accridited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The successful bidder must submitt the NABL accreditation certificate for Luminaire manufacturer along with Spec/Make Approval. The LED Luminaire & it\"s driver both should be BIS registered withwarranty of Min 3 years. Successful bidder shallsubmit the following reports along withSpecs/Make Approval - LM79 issued by LED manufacturer, Type test Certificate for luminaire as issued by NABL accrdited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED luminaire & Driver. |
| 6 | Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured heavy duty confirming to relevant IS specifcations with stranded aluminum conductor of size 16 sqmm 4.0 core complete all as specified and as directed. |
| 7 | Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured heavy duty confirming to relevant IS specifcations with stranded aluminum conductor of size 25 sqmm 4.0 core complete all as specified and as directed. |
| 8 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for taking out/for laying under ground cables/pipes etc and getting out any type soil complete all as specified and directed |
| 9 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 10 | Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 11 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed. Note :- Only punned down sand shall be measured. |
| 12 | Supplying and laying un- reinforced precast concrete cable cover, class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed |
| 13 | Boring of holes under road, pavement, hard standing by trenchless technologytechnique for 40-80 mm dia pipe all as specified and as directed. |
| 14 | Material & Labour for GI pipe light grade ofsizes 40mm dia, ISI marked with all fitting for cable protection, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc all as specified and as directed. |
| 15 | Material & Labour for cement concrete type B1 1:2:4 using 40 mm graded crushed stone aggregate for making good surfaces in road cutting, pole foundation, stay concrete complete all as specifed and directed. |
| 16 | Material & Labour for cement concrete type B2 1:2:4 using 40 mm graded crushed stone aggregate for making good surfaces in road cutting, pole foundation, stay concrete complete all as specifed and directed. |
| 17 | Material & Labour for plain cement concrete type C1(1:3:6) using 20 mm graded crushed stone aggregate as in coping including necessary form work and finishing exposed surface/white washing complete all as specifed and directed. |
| 18 | Supply and fixing thermo plastic cable terminal box of size not less then 250x200x100mm including3 Phase terminals PVC connector for cable with suitable glands with locking arrangments including necessary mounting arrangement of any steel tubular with suitable size of clamps nuts bolts washer etc. fixed with poles including one single pole MCB of capacity 6-32A. complete all as specified and directed. |
| 19 | Supply & fixing wheather proof copper three core cable of size 1.0 Sqmm drawn in and including UPVC conduit medium grade fixed to pole/wall with suitable size clamps or fixing accessories complete all as specified and directed. |
| 20 | Supply & fixing street light bracket single arm fixing on the pole,made of GI pipe light grade pipe size not less than 1.5 Mtr, 32/40 mm dia as per sample and fixed with suitable size of MS clamps, nut, bolt, washers, welding work as required etc to poles/walls complete all as directed. |
| 21 | Supply and Instal LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made CPRI approved out of 3.15 mm thick CRCA sheet of size not less then 900mm x 900mm x 450mm and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting locking arrangement and painted to both internal and external surfaces with powder coating paint in heatprocess in grey colour, the rate quoted by tenderer also includes to fix the legs of the panel box in PCC (1:3:6) pot hole foundation 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. complete all as specified and as directed and comprising the followings:-(a) Aluminium bus bar of minimum capacity 100 Amps- 01 (set of 04)(b) MCCB, 4P, 63 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No (as Incoming)(c) MCCB, 4P, 32 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos(d) Digital timer switch (24 hrs operation) - 01 No (e) Contactor 32 Amps capacity three phase, 415 Volts 50 Hz (f)LED R-Y-B indicating lamps (Set of Three)- 01 set |
| 22 | Material & Labour for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.Note : - Length of earth lead and protection pipe in above mentioned item is considered upto 7.50 m. Additional length required shall be measured and paid separately. |
| 23 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways completeall as specified & directed.Note : - Length of earth lead and protection pipe in above mentioned item is considered upto 7.50 m. Additional length required shall be measured and paid separately. |
| 24 | Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 8 KW (10 KVA),415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tankwith mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Dinjan (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB-IV guidelines and Comprising of followings:- |
| 25 | (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, 6 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering8 KW(10 KVA) atoutdoor atmospheric conditions at Dinjan, (Taking all derating factor into consideration),12/24 Volt (as per manufacturer recommendations) electric battery start incl suitable size battery, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc .(ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 8 KW(10 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \"H\", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.(iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition .(v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M(vi)Diesel storage tank of capacity adequate for storage of diesel as per manufacturer specification.(vii) AMF Panel: -Microprocessor / Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum bas bar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete.(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW,frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d)All standard relays, circuitsand protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. |
| 26 | (ix) First fill of Lubricants, Coolant & Fuel: -First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn.Note: PCC foundation for DG Setshall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(d) One set of latest Spare part catalogue with price, exploded view of parts and user\"s manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer\"s drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level |
| 27 | Design, Supply, Erection, Testing and commissioning including comprehensive maint for 5 years of Ground Top Solar Power Generation Plant of capacity 7.5 KWp (AC) at output Voltage 415 Volt, 50Hz, ON GRID Hybrid solar roof top with batteries back up for captive use not less than three times the rated power as per specification & complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, 2. DC junction, Distribution & combiner boxes, AC junction & combiner boxes,lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications complete all as specified and directed |
| 28 | Material & Labour for Plain Cement Concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |