}

Supply Installation Testing And Commissioning Of Air Conditioner Machine Split Type 100 Percent Copper 2.0 Tr,Inverter Type With Remote Controller To Be Installed In The Smart Class Room ,4Th Floor Of New Buildingl At Djftyijt, University Of Calcutta. , , Kolkata-West Bengal

University Of Calcutta has published Supply Installation Testing And Commissioning Of Air Conditioner Machine Split Type 100 Percent Copper 2.0 Tr,Inverter Type With Remote Controller To Be Installed In The Smart Class Room ,4Th Floor Of New Buildingl At Djftyijt, University Of Calcutta. , . Submission Date for this Tender is 27-06-2025. Air Conditioner Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

49759381
Supply Installation Testing And Commissioning Of Air Conditioner Machine Split Type 100 Percent Copper 2.0 Tr,Inverter Type With Remote Controller To Be Installed In The Smart Class Room ,4Th Floor Of New Buildingl At Djftyijt, University Of Calcutta. ,
Tender
Indian
West Bengal
Kolkata
27-06-2025

Tender Details

supply installation testing and commissioning Of Air Conditioner Machine Split Type 100 Percent Copper 2.0 Tr,Inverter Type With Remote Controller To Be Installed In The Smart Class Room ,4Th Floor Of New Buildingl At Djftyijt, University Of Calcutta. , Sitc Of3 Star Rating Split Air Cinditioner Machine With R32 Gas Including Remote Controller Of Following Capacity Suitable For Operation On 230V +/- 10% Volt,50Hz Single Phase Ac Supply With Air Cooled Evaporator With Copper Coil,Fan And Fan Motor.Air Cooled Copper Condenser, Hermetically Sealed Copper Compressor,Propeller Fan Control Panels Incl Wirings,Necy Power Cable Connections From Unit To Power Socket,Refrigerant Pipe Of Appropriate Size Between Indoor And Outdoor Unit Upto 3 Mtr Length. Both Suction & Delivery Incl. Gas Charging,Complete As Required Make ;Necy Ply Wood Board Of 19 Mm To Be Fixed For Installation Of The Machine,Duly Painting As Per Wall Colour Make.Hitachi,Daikin,Blue Star,2.0 Tr , Providing And Fixing Copper Pipe With Nitrile Rubber Insulation Not Less Than 0.6Mm Thickness Suitable Size Required For Suction And Return Refrigerant With Suitable Insulation For Above Ac S Complete In All Aspects As Required In Excess Of 3Mtrs / Machine , Supply And Laying 20Mm Dia Isi Markedflexiblepvc Pipe Along With Accessories On Surface Of The Wall To Drain Out Condensate Water From Indoor Unit5 To10mm Thickness 3 Dia.3 Thickness 5-10 Mm , S And F Factoryfabricated Ms Structure For Placing The 1.5Tr Capacity Split Outdoor Uniton Existing Building. By Ms Fastner , S Andf 4C Flexib;E Copper Cable Of 4Sq.Mm From Indoor To Outdoor Unitc L.Connection, Commissioing Testing Etc As Reqd , Disrtibution Wiring In 1.1Kv Single Core Stranded Fr Pvc Insulated & Unshe Athed Copper Wirein 20Mm Size Pvc Rigid Conduit Fr…As Required A)2X84/0.3(6Sq.Mm)+1X56/0.3(4Sqmm) Ecc [Logic Circuit] , S&F 240V,25A Mod Type Socket,25A Mod Type Starter With 25A Mod Switch Type Dp Mcb &6 Mod Gi….Earth Continuity Wire Etc[Logic Timer]

Key Value

Document Fees
Refer document
EMD
INR 2100.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail