Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #49751329

Tender For Supply And Installation Of Transfarmer, Dg Set And Connection Accessories Work In Convention Center At Polytechnic Ground Jhansi.

Issued by Local Bodies · jhansi, Uttar Pradesh
Tender Value
1.18 Crore
Estimated cost
Bid Submission
30 Jun 2025
0 days left
EMD
2.36 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jhansi → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Supply And Installation Of Transfarmer, Dg Set And Connection Accessories Work In Convention Center At Polytechnic Ground Jhansi.

BOQ

Name of Work: Supply & Installation of Transfarmer, DG Set & Connection Accessories work in Convention Center at Polytechnic Ground Jhansi.
Sl. No. Item Description
1Name of Work: Supply & Installation of Transfarmer, DG Set & Connection Accessories work in Convention Center at Polytechnic Ground Jhansi.Note :-(1)-GST Excluded on the aforesaid work.
2Supply, installation, testing and commissioning of following capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) ,11/0.433 KV step down, 3 Phase,50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked and as per CPWD specifications complete in all respects etc as required at site. 1000 KVA DSR 2025 Item no 3.6 & 3.6.1 DSR 2025 Item no 3.6 & 3.6.1
3Supply, installation, Testing & Commissioning of \"Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo-Tag of manufacturing location, rating plate as per relevant IS Code etc. 250 KVA DSR 2025 Item no 6.1 ^ 6.1.11DSR 2025 Item no 6.1 ^ 6.1.11
4500 KVA 6.1.156.1.15
5SITC 3 way VCB 11KV HT panelMRMR
6SITC of Synchronization panel for Sink the power of both DG setsMRMR
7supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. (a)300sqmm DSR E&M 10.4 & 10.4.4DSR E&M 10.4 & 10.4.4
8Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 300sqmm DSR E&M 10.5 & 10.5.4DSR E&M 10.5 & 10.5.4
9Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 300sqmm DSR E&M 10.6 & 10.6.4DSR E&M 10.6 & 10.6.4
10Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.185 sq. mm x 3-1/2 coreSOR 2024 (20a.1.17)SOR 2024 (20a.1.17)
11300 sq. mm x 3-1/2 core(20a.1.19)(20a.1.19)
12Supply and laying of2.5 sq. mm x 4 core Copper Cable Stock Issue 2024-25 Stock Issue 2024-25
13Supply 11 KV HT XLPE Cable 3C x 185 Sq.mm uppcl cost data (annexure-9)uppcl cost data (annexure-9)
14Laying of one number of PVC insilated & PVC sheathed / XLPE power cable of 11 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sqmm and upto 400 sqmmDSR E&M 8.1 & 8.1.2DSR E&M 8.1 & 8.1.2
15Supply and fixing ofcore brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge(q) 185 sq. mm 3-1/2 core SOR 2018- 503 SOR 2018- 503
16300 sq. mm 3-1/2 core (s)(s)
17Supply and fixing ofplain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.(I) 185 sq. mm SOR 2018- 504 SOR 2018- 504
18300 sq. mm (n)(n)
19Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. DSR E&M 5.4DSR E&M 5.4
20Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.DSR E&M 5.6DSR E&M 5.6
21Providing and Fixing25MM x 5MM Copper Flat Strip on surface or in recess for Connection etc as requiredDSR E&M 5.14DSR E&M 5.14
22Providing and Fixing25MM x 5MM GI Flat Strip on surface or in recess for Connection etc as requiredDSR E&M 5.15DSR E&M 5.15
23Supply, receive at site, store, unpack, assemble and connect Exhaust pipe with Class-B MS pipewith flanges, fire fly gaskets, hardware, Rockwool and aluminium sheet cladding etc. inclusive of all supports of wall/ceiling etc. For 1 x 200 mm - 250 MM DIA, MS Class B Pipe WALL THICKNESS as per IS Standardfor each DG Set or as per Manufacturers recommendated size Straight Horizontal + Vertical Exhaust pipe including Bends as required with two coats of zinc chromate painting & Rockwool of standarddensity finished with 24 Guage aluminium sheet cladding per DG Set with Rain Cowl with supports for PipeMRMR
24Supply, receive at site, store, unpack, assemble and connect Exhaust pipe with Class-B MS pipewith flanges, fire fly gaskets, hardware, Rockwool and aluminium sheet cladding etc. inclusive of all supports of wall/ceiling etc. For 350 MM DIA, MS Class B Pipe WALL THICKNESS as per IS Standardfor each DG Set or as per Manufacturers recommendated size Straight Horizontal + Vertical Exhaust pipe including Bends as required with two coats of zinc chromate painting & Rockwool of standarddensity finished with 24 Guage aluminium sheet cladding per DG Set with Rain Cowl with supports for PipeMRMR
25MS SUPPORT STRUCTURES FOR EXHAUST - Supply, fabrication and erection of Hot Dip Galvanised [100+ Micron] steel structure , with required Nut Bolt & Accessories. SOR 2022 civil502SOR 2022 civil502
26RCC Foundation for Exhaust Structure with foundation bolt MRMR
27Making Plinth for Transformer & DG Set complete as per Direction of Engineer in ChargeMRMR
28Providing and fixing of lightning conductor finial made of 25mm dia 300mm long. G.I. tube having single prong at top with 85mm dia 6mm thick G.I. base plate including holes etc. Complete as required. DSR E&M 6.2DSR E&M 6.2
29Jointing copper / G.I. tape ( with another copper/ G.I tape , base of the final or any other metalic object ) by Riveting / nut bolting / sweating & soldering etc as required.DSR E&M 6.4DSR E&M 6.4
30Providing and fixing testing joint, made of 20mmx 3mm thick G.I. strip, 125mm long, with four no. of G.I. bolts, nuts, chuknuts & spring washers etc copmlete as required.DSR E&M 6.12DSR E&M 6.12
31providing & Laying copper /G.I. tape 32mmx 6mm from earth electrod directly in ground as required.DSR E&M 6.14DSR E&M 6.14
32Supply and installation of Aviation Light at the top of Chimney structure including wiring and UPS connection complete in all respectMRMR
33Yard Fencing with Wire Mesh Chain Link 100MM x 100MM x 10MM Wire with Civil Work & Gate complete in all respect as per direction of the Engineer-Incharge.MRMR
34Supply & Fixing of MS Febricated Steel with two Cote Redoxide & 1 Cote of Black Enamel Paint complete in all respect as per direction of the Engineer-InchargeMRMR
35Supply & Fixing 11 KV Danger Board with clamp as per Direction of Engineer in Chargeuppcl cost data (annexure-17)uppcl cost data (annexure-17)

AI Tender Summary

OUR REF NO 49751329
AUTHORITY Local Bodies
TENDER VALUE 1.18 Crore
LAST DATE 30-06-2025
Authority
Authority Name Jhansi Development Authority
Work Description Supply And Installation Of Transfarmer, Dg Set And Connection Accessories Work In Convention Center At Polytechnic Ground Jhansi.
Basic Detail
Tender No 450/JDA/2025-26
Bidding Type Tender
Location
City jhansi
State Uttar Pradesh
Key Dates
Publish Date 19 Jun 2025
Submission Date 30 Jun 2025
Open Date 30 Jun 2025
Finance
Tender Value 1.18 Crore
Tender Fee 11800
EMD 2.36 Lakhs
Exemption Available
Document List
66fde46e-e82e-4db1-8f55-0df8c819012a.html
FinalUpload.pdf
Tendernotice_1.pdf
BOQ_1908584.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 19, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 30, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 30, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

66fde46e-e82e-4db1-8f55-0df8c819012a.html

pdf

FinalUpload.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_1908584.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders