| 1 | M&L for dewatering the complete water from surface mounted sedimentation tank of filtration plantNo-Iof size: 14.50 meters long,9 meters width and 5 meter deep with the help of electric driven pumping set after that remove all silt, sediments and other foreign material from the tank and remove all material from the siteexceeding 50 metersdepositing where directed at a level n exc. 1.5 m above from the starting point & than clean complete inside wall with the help of wire brush and bleaching powder and finally washing with clean water complete all as specified and directed.Location:MES Pump House Happy valley.Note : 1. The pump set along with fuel (diesel / petrol) required for dewatering shall be arranged by the contractor without any extra cost to the department.The rate quoted shall bedeemed to be included for the same.(a) Draining out reserved water by opening drain out valve/ dewatering system.(b) Removing all scale, dirt, mud inside the tank by using TERBACK G10 Chemical and Scrubbing the wall of tank all complete.(c) Cleaning inside sufaces of the tank with Fresh water by high speed jet pumpall complete.(d) First bacteria screening for sterilisation by using TERBACK all complete.(e )Cleaning the floor of the water tank by heavy duty industrial vacuum cleanerall complete.(f)Second bacteria screening for sterilisation by using UV rays all complete.(g) Third bacteria screening for sterlisation by using TERBACK G65.Note : - (1)The entire cleaning work should be carried out be TANKCLEAN process by any franchises or any other MES approved firm having equivalent technology.(2) Entire T&P should be arranged by the Contractor at their own. Only electric power & water shall be supplied by MES at the stipulated rate.(3) \"Date of cleaning\" should be written over the outer surface of tank by synthetic enamel paint with lettering not less than 100 mm height. Cost of the same is deemed inclusive in the quoted unit rate of cleaning of tank. |
| 2 | All as per item No. 01 hear in before but of size 15 mtrs long, 8.5mtrs width and 5 Mtrs long, Filtration plant No:II |
| 3 | All as per item No. 01 hear in before but of size 14 mtrs long, 8.5mtrs width and 5 Mtrs longFiltration plant No:III. |
| 4 | M&L for dewatering the complete water from surface mounted sedimentation tank of size: 16 meters long,12.60 meters width and 3.50 meter deep with the help of electric driven pumping set after that remove all silt, sediments and other foreign material from the tank and remove all material from the siteexceeding 50 metersdepositing where directed at a level n exc. 1.5 m above from the starting point & than clean complete inside wall with the help of wire brush and bleaching powder and finally washing with clean water complete all as specified and directed.Location:MES Pump House Happy valley.Note : 1. The pump set along with fuel ( diesel / petrol) required for dewatering shall be arranged by the contractor without any extra cost to the department.The rate quoted shall bedeemed to be included for the same. |
| 5 | M&L for dewatering the complete water from surface mounted sedimentation tank of size: 18 meters long,17 meters width and 3.50 meter deep with the help of electric driven pumping set after that remove all silt, sediments and other foreign material from the tank and remove all material from the siteexceeding 50 metersdepositing where directed at a level n exc. 1.5 m above from the starting point & than clean complete inside wall with the help of wire brush and bleaching powder and finally washing with clean watercomplete all as specified and directed.Location:MES Pump House Happy valley.Note : 1. The pump set along with fuel ( diesel / petrol) required for dewatering shall be arranged by the contractor without any extra cost to the department.The rate quoted shall bedeemed to be included for the same. |
| 6 | M&L for dewatering the complete water from underground Clear water sump of size: 16.50 meters long, 5.50 meters width and 3.5 meter deep with the help of electric driven pumping set after that remove all silt, sediments and other foreign material from the tankthan clean complete inside wall with the help of wire brush and bleaching powder and finally washing with clean water complete all as specified and directed. Location:Pump House Happy valley.Note : 1. The pump set along with fuel ( diesel / petrol) required for dewatering shall be arranged by the contractor without any extra cost to the department.The rate quoted shall bedeemed to be included for the same. |
| 7 | All as per item No. 06 hear in before but of size: 6 meters long, 3 meters width and 3.5 meter deep, Location: MESPump House Happy valley |
| 8 | All as per item No. 06 hear in before but of size: 12meters long, 7.50 meters width and 3.5 meter deep,Location: MESPump House Happy valley. |
| 9 | M&L for dewatering the complete water from underground clear water sump of capacity 600000 Gallon with the help of electric driven pumping set after that remove all silt, sediments and other foreign material than clean complete inside tiles fitted on inside wall with the help of wire brush/Steel wool/scotch bright and bleaching powder and finally washing with clean water complete all as specified and directed. Location: Pump House Happy valley. SIX tank, 58 GTC Near 11EWU.Note : 1. The pump set along with fuel ( diesel / petrol) required for dewatering shall be arranged by the contractor without any extra cost to the department.The rate quoted shall bedeemed to be included for the same. |
| 10 | All as per item No. 9 hear in before but of overhead, PS Tank of capacity 40000 Gallon,Location: 58 GTC near Disco mode. |
| 11 | All as per item No. 9 hear in before but offrom overhead, PS Tank of capacity 50000 Gallon, Location:58 GTC near Soltee Hall. |
| 12 | All as per item No. 9 hear in before but ofoverhead, RCC Tank of capacity 50000 Gallon,Location: 58 GTC near MI Room. |
| 13 | All as per item No. 9 hear in before but ofoverhead, RCC Tank of capacity 50000 Gallon,Location: 58 GTC near Trg Bn. |
| 14 | All as per item No. 9 hear in before but ofoverhead, RCC Tank of capacity 75000 Gallon,Location: Near MES Qtrs ARC. |
| 15 | All as per item No. 9 hear in before but of overhead, RCC Tank of capacity 50000 Gallon. Location: Near State bank of India ARC. |
| 16 | All as per item No. 9 hear in before but of overhead, PS Tank of capacity 40000 Gallon. Location: Near State bank of India ARC. |
| 17 | All as per item No. 9 hear in before but ofoverhead RCC Tank of capacity 100000 Gallon. Location: Trg. Bn. ARC (Tagra Raho). |
| 18 | All as per item No. 9 hear in before but of overhead, RCC Tank of capacity 75000 Gallon.Location: Officers Mess ARC. |
| 19 | All as per item No. 9 hear in before but ofoverhead, RCC Tank of capacity 50000 Gallon. Location: Near FAFA Qtrs ARC. |
| 20 | All as per item No. 9 hear in before but of overhead, PS Tank of capacity 40000 Gallon. Location: Near FAFA Qtr ARC (Nerula). |
| 21 | All as per item No. 9 hear in before but of overhead, PS Tank of capacity 30000 Gallon. Location: Near ARC Officer Mess. |
| 22 | All as per item No. 9 hear in before but of overhead, RCC Tank of capacity 30000 Gallon. Location: Near ARC (Nerula). |
| 23 | All as per item No. 9 hear in before but of overhead, PS Tank of capacity 5000 Gallon. Location: Near Boxing Hall 58 GTC. |
| 24 | All as per item No. 9 hear in before but of overhead, PS Tank of capacity 20000 Gallon. Location: Near 11 WEU. |
| 25 | M&L for cleaning of Underground/semi underground sumps of 1 Nos of 10000 Gallon capacity through 7\" stage mechanical tank cleaning process by involving the following six (7) stages of cleaning process complete all as specified and as directed by Engr-in-Charge. Location : SE Falls |
| 26 | All as per Item No. 25 above complete but for RCC Overhead Reservoir upto 30 ft high staging of 30000 Gallon capacity . Location : SE Falls |
| 27 | All as per Item No. 26 above complete but for RCC/PS Overhead Reservoir upto 30 ft high staging of 10000 Gallon capacity. Location : SE Falls |
| 28 | M&L for PCC 1:3:6 type C2 (Using 40 mm graded stone aggregate) after levelling the area around filtration plant / sedimentation tankcomplete all as specified and directed . |
| 29 | M&L for PCC 1:2:4 type B-1 (Using 20 mm graded stone aggregate) as in coping/benching incl. sheathing slightly chamfered on edge and finishes exposed surfaces even smooth with out using extra cement including necessary from work/Road cutting/complete all as specified and directed . |
| 30 | Supply and fix in replacement MCCB 630Amps,50 KA, 4 pole inclusive all incoming and outgoing electric connection & takingout old one complete all as specified and directed. |
| 31 | Supply and fix in replacement Changeover Switch 630Amps,50 KA, 4 pole inclusive all incoming and outgoing electric connection & takingout old one complete all as specified and directed. |
| 32 | Supply and fix in replacement MCCB 400 Amps,36 KA, 4 pole inclusive all incoming and outgoing electric connection & takingout old one complete all as specified and directed. |
| 33 | Supply and fix in replacement over load relay, type MN, directmounting, relay rang 24-40Amps, inclusive all incoming and outgoing electric connection & takingout old one complete all as specified and directed. Make: L&T or equivalent in ABB/BCH |
| 34 | Supply and fix in replacement Post top for 360 degree , LED land scape lighting with IP-65protection 1X60W, 230 Volts,completeinclusive all incoming and outgoing electric connection & takingout old one complete all as specified and directed. |
| 35 | Supply and fix in replacement copper cable 50 Sqmm, single core, multistranded, heavy duty, 1100 volts grade completeinclusive all incoming and outgoing electric connection with copper cable lugs& takingout old onecomplete all as specified and directed. |
| 36 | Supply and fix in replacement copper cable 25 Sqmm, single core, multistranded, heavy duty, 1100 volts grade completeinclusive all incoming and outgoing electric connection with copper cable lugs& takingout old onecomplete all as specified and directed. |
| 37 | Supplyand fixing or laying in replacement GI Tubing \" Light grade\"50 mm bore for passing, LT, UG/ fixing post top LED light fittingincluding all fittingssuch aselbow, bend, socket, socket reducer, tees etc. complete all as specified and directed. by Engr-in-Charge. |
| 38 | S&F in replacement XLPE insulated screened PVC bedded, galvanized steel strip of wirearmoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core including taking downcomplete all as specified and directed. |
| 39 | S&F in replacementXLPE insulated screened PVC bedded, galvanized steel strip of wirearmoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core including taking downcomplete all as specified and directed. |
| 40 | S&F in replacement XLPE insulated screened PVC bedded, galvanized steel strip of wirearmoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core including taking downcomplete all as specified and directed. |
| 41 | Labour only for cleaning of upper Dam/ Lower dam of area 10meter long, 05mtrs width and 2 mtrs deep inclusive all necessary cleaning and safety equipments such as Axes picks, crowbar, showel etc. Note: Per job five labours are requiredcomplete all as specified and directed. |
| 42 | Supply & fixingin replacement ofLED street light fitting35 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K,LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range-10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs :LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular poleincl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. |
| 43 | Cleaning and removing all scale and dirt etc from PVC/RCC/MS overhead tanks by using wire brush, bleaching powder or lime etc of required quantity and washing with clean water from tank and mouth of circulating pipe after disconnecting existing tanks, setting aside (or lowering if required) for repair, cleaning, etc and hoisting if required, reconnecting and refixing in position of capacity exc 500 n.exc 1000Ltrs incl writing \"TC on -DD/MM/YY\" with white synthetic enamel paint with 5 cm font in capital letters etc complete all as specified and directed.Note:- Proper record of cleaning of tank done under subject item shall be maintained in a register by sub division ,duly authenticated by user or user repand Engineer-in-charge and shall be produced at the time of claiming any payments. |
| 44 | Cleaning and removing all scale and dirt etc from PVC/RCC/MS overhead tanks by using wire brush, bleaching powder or lime etc of required quantity and washing with clean water from tank and mouth of circulating pipe after disconnecting existing tanks, setting aside (or lowering if required) for repair, cleaning, etc and hoisting if required, reconnecting and refixing in position of capacity exc 1000 n.exc 2000 Ltrs incl writing \"TC on -DD/MM/YY\" with white synthetic enamel paint with 5 cm font in capital letters complete all as specified and directed.Note:- Proper record of cleaning of tank done under subject item shall be maintained in a register by sub division ,duly authenticated by user or user repand Engineer-in-charge and shall be produced at the time of claiming any payments. |
| 45 | S&F in replacement Rotational moulded HDPEpolyethylene 500 ltrs capacity water storage tanks three layered, (ISI marked) (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball valves 20 mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball including 20mm dia GI medium grade over flow pipe, approx lenght 1.5 mtr, 25 mm dia wash out pipe with pluged at one end including taking down complete all as specified and directed. |
| 46 | S&F in replacement rotational moulded polyethylene 1000 ltrs capacity water storage tanks , three layered, (ISI marked) (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball valves 20mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball including 20mm dia GI medium grade over flow pipe, approx lenght 1.5 mtr, 25 mm dia wash out pipe with pluged at one end including taking down complete all as specified and directed. |
| 47 | S&F in replacement 20mm ball valve, high pressure of PTMT, with epoxy coated aluminium rod and high density plasic ball screwd for iron pipe (min wt 20mm-210 gms) complete, screwed for iron pipe including taking down complete all as specified and as directed. |
| 48 | S&F in replacement 25mm ball valve, high pressure of PTMT, with epoxy coated aluminium rod and high density plasic ball screwd for iron pipe (min wt 25mm-455 gms) complete, screwed for iron pipe including taking down complete all as specified and directed |
| 49 | S&F in replacement PVC lid (cover) suitable for water tank of capacity (500/1000 ltrs) all as specified and directed |
| 50 | S&F in replacement PVC nipple of size 20mm dia bore suitable for HDPE water storage tank etc complete all as specified and as directed. |
| 51 | S&F in replacement PVC nipple of size 25mm dia bore suitable for HDPE water storage tank etc complete all as specified and as directed. |
| 52 | Taking out / Lowering carefully submersible pump set 7.5/5 HP from 300 to 340 feet deep wellafter disconnecting all incoming and outgoing electric and water pipe line connectionand keep the all pipe and cable in safe custody for reuse at same work for lowering the submersible pump set complete all as specified and as directed by Engr-in-charge.Note:-(i)Before lowering the pump all flanges must be proper welding.(ii) The repairs part of pump and motor will be measured andpaid separately. |
| 53 | M&L in replacement Motor Rewinding of submersible pump 7.5 Hpincluding replacement of bush/bearing, check nuts, connector complete. |
| 54 | M&L in replacement Motor Rewinding of submersible pump 5 Hpincluding replacement of bush/bearing, check nuts, connector complete all as specified and as directed. |
| 55 | M&L in replacement Pump repair complete including replacement of bush, bearing, impeller of capacity 7.5 HP complete all as specified and as directed. |
| 56 | M&L in replacement Pump repair complete including replacement of bush, bearing, impeller of capacity 5 HP complete all as specified and as directed. |
| 57 | S&F in replacement Stay wire rope steel, 10 Sq mm including taking down old unserviceable complete all as directed by Engineer-in-Charge. |
| 58 | S&F in replacement copper cable 3 core flat suitable for submersible pump set 10 Sqmm including taking down old unserviceable complete all as directed by Engineer-in-Charge. Make: Havells. |
| 59 | S&F in replacement Supporting clamps made out of flat iron 6mm thick and 65mm width suitable for up to 50mm bore pipe including taking down old unserviceable complete all as directed by Engineer-in-Charge |
| 60 | S&F in replacement Bore Cover suitable for 200mm dia pipe including taking down old unserviceable complete all as directed by Engineer-in-Charge. |
| 61 | S&F in replacement GI tubing 80 mm dia medium gradeincluding taking down old unserviceable complete all as directed by Engineer-in-Charge. |
| 62 | S&F in replacement Adaptor including taking down old unserviceable complete all as directed by Engineer-in-Charge. |
| 63 | Supply and fix in replacement star delta starter 7.5 HP complete inclusive all incoming and out going electric connection and testing complete all as specified and as directed by Engr-in-charge |
| 64 | Supply and fix in replacement star delta starter 5 HP complete inclusive all incoming and out going electric connection and testing complete all as specified and as directed by Engr-in-charge |
| 65 | Development of existing bore well by flushing out with compressed air at 10 Kgs/Sqcm appx for removing of sand and silt for obtaining portable water including discoconnection ofall electric and water connectionof existing submerssible pump set up to 12.50 HP cap of three phase AC supply and taking out carefully 50/80 mm dia GI pipe with submercible cable from borewell and dismantling of each length carefully to bring out the submercuible motor and re-loweringcomplete all as specified and and directed. Note - (a) unserviceable / srusted GI pipe taking out from the borewell to be replaced by GI pipe of suitable size given in items as supply only of this schedule. (b) flushing of bore should not less than 12 hrs for each bore. |
| 66 | Taking outold burnt100/90 HP induction motor 415 volts, 3 phase after disconnectingall incoming and outgoing electric connection, foundation bolts, decupling from pump & transporting to workshop, dismantling it completely, removing the burnt out winding & rewindingsamesize super enamelled copper wire & replace all defective parts such as bearing etc and fixing on same position & testing complete all as specified and as directed by Engr-in-charge |
| 67 | Taking outthe worn- out 100/90 HPpumping setafter disconnecting the all incoming and outgoing150mm bore CIpipe connection including 150mm NRV, Sluice valve , bend, electric connection, foundation bolts, decupling withelectric motor& transporting to workshop, dismantling it completely, replacing theall deteriorated partssuch as bearing, impeller, pump shaftetc and fixing on same position & testing complete all as specified and as directed by Engr-in-charge |
| 68 | Taking outold burnt40 HP induction motor 415 volts, 3 phase after disconnectingall incoming and outgoing electric connection, foundation bolts, decupling from pump & transporting to workshop, dismantling it completely, removing the burnt out winding & rewindingsamesize supper enamelled copper wire & replace all defective parts such as bearing etc and fixing on same position & testing complete all as specified and as directed by Engr-in-charge |
| 69 | Taking outthe worn- out 40 HPpumping setafter disconnecting the all incoming and outgoing100mm bore CIpipe connection including 100mm NRV, Sluice valve , bend, electric connection, foundation bolts, decupling withelectric motor& transporting to workshop, dismantling it completely, replacing theall deteriorated partssuch as bearing, impeller, pump shaftetc and fixing on same position & testing complete all as specified and as directed by Engr-in-charge |
| 70 | Taking up or down the defective Monoblock pump set of any make 415 volt 3 phase 05 HP by dismantling the electrical connections, removing the motor by decoupling with pump, transporting to workshop, dismantling it completely, removing the burnt out winding, rewinding the same with super enameled copper wire of existinggauge replacementof unserviceable part includingbearing and with necessary insulating material, varnishing, backing and re assembling the serviceable motor completely withall connections complete all as specified and as directed by Engr-in-charge.Note : (i)Burnt out removed winding wire shall be property of contractor and shall be paid under schedule of credit. |
| 71 | Taking up or down the defective Inductionmotor of any make 415 volt 3 phase 7.5 HP by dismantling the electrical connections, removing the motor by decoupling with pump, transporting to workshop, dismantling it completely, removing the burnt out winding, rewinding the same with super enameled copper wire of existinggauge replacementof unserviceable part includingbearing and with necessary insulating material, varnishing, backing and re assembling the serviceable motor completely withall connections complete all as specified and as directed by Engr-in-charge.Note : (i)Burnt out removed winding wire shall be property of contractor and shall be paid under schedule of credit. |
| 72 | Repair and maintenance of 100/90 HP Pumping set for replacing Bearing, Bush, Gland packing, Connector etc complete all as specified and as directed by Engr-in-charge. Note Spare parts will be measured and paid separately. |
| 73 | Supply only Ball Breading 6309 Make: Tata/SKF/NBC |
| 74 | Supply only Ball Bearing7309 Make: Tata/SKF/NBC |
| 75 | Supply only Gland Packing 20 mm Heavy Duty complete all as specified and as directed. |
| 76 | Supply only Rubber coupling bush complete all as specified and as directed. |
| 77 | Repair and maintenance of 40/25 HP Pumping set for replacing Bearing, Bush, Gland packing etc complete all as specified and as directed by Engr-in-charge. Note:Spare parts will be measured and paid separately. |
| 78 | Supply only Ball Bearing6307 complete all as specified and as directed.Make: Tata/SKF/NBC |
| 79 | Supply only Rubber cupling bush complete all as specified and as directed. |
| 80 | Repair and maintenance of 100/90 HP Electric motor, three phase for replacing Bearing, Connector etc complete all as specified and as directed by Engr-in-charge. Note:Spare parts will be measured and paid separately. |
| 81 | Supply only Ball Bearing6312 complete all as specified and as directed.Make: Tata/SKF/NBC |
| 82 | Supply only Ball Bearing6314 complete all as specified and as directed. Make: Tata/SKF/NBC |
| 83 | Supply only Ball Bearing6316 complete all as specified and as directed. Make: Tata/SKF/NBC |
| 84 | Repair and maintenance of 40/25 HP Electric motor, three phase for replacing Bearing, Connector etc complete all as specified and as directed.Spare parts will be measured and paid seeprately. |
| 85 | Supply only Ball Bearing6304 complete all as specified and as directed.Make: Tata/SKF/NBC |
| 86 | Supply only Ball Bearing4064 complete all as specified and as directed.Make: Tata/SKF/NBC |
| 87 | Supply and Fixing Mild steel coupling suitable for 100/90 HP pumping set complete all as specified and as directed by Engr-in-charge. |
| 88 | Dismantling of existing 90 HP pumping setfrom the foundation after disconnecting all incoming and out going electric & water supply connectionincluding sluice valve, non return valve, bend etc. and keep the pumping setin safe custody after that dismantling existing foundation with the help of power hammer drill machine and construction of new foundation on same place as per existing size inclusive of foundation bolt & nuts & fix the same pump in same position and testing complete all as specified and as directed by Engr-in-charge |
| 89 | M&L in replacement of Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with a 15 cm thick layer of char coal dust and common salt, and using galvanised iron strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and connected to earth test point, earthing protected by galvanized iron pipe light grade 15 mm. bore and water pipe 20 mm. bore GI light grade with funnel and wire mesh PCC chember in cement concrete 1:3:6 type C-2 & RCC cover including taking down of old earthing materials complete all as specified & and as directed ( Note-:If the earthing result will be not proper as per disered specification than earthing will be redone without any extra cost.) |
| 90 | S&F in replacement Motor terminal suitable for 100 / 90 HP Motor including necessary electrical connection complete. |
| 91 | S&F in replacementMotor terminal suitable for 40 / 25 HP Motor including necessary electrical connection complete. |
| 92 | S&F in replacement Bushing suitable for 100/ 90 HP Motor including necessary electrical connection complete. |
| 93 | S&F in replacement Bushing suitable for 7.5 / 5 HP Motor including necessary electrical connection complete. |
| 94 | S&F in replacement gland plate including full threaded nut & bolt for pump capacities 90/100 HP complete all asdirected by Engineer-in-Charge. |
| 95 | S&F in replacement gland plate including full threaded nut & bolt for pump capacities 7.5 / 5 HP complete all asdirected by Engineer-in-Charge. |
| 96 | M&L for preparation of old deteriorated surfaces of iron and applying after making good surface one coat of redoxide primer two coat of synthetic enamel paint complete all as specified and directedby Engr -in- Charge. |
| 97 | S&F in repairs four pole 415 volts, 80 Amps contactorfor 40 HP motor starter complete all as directed by Engineer-in-Charge. |
| 98 | S&F in repairs thermal over load relay (Auto/manual reset) relay range 66-110 Amps for motor starter all as directed. |
| 99 | S&F in repairs thermal over load relay (Auto/manual reset) relay range 22-30 Amps for motor starter all as directed. |
| 100 | S&F in repairs thermal over load relay (Auto/manual reset) relay range 48-70 Amps for motor starter all as directed. |
| 101 | S&F Single phase preventor electronic type with tripping system against single phase & Phase reversal suitable for protection of electric motor 3 phase 415 volt AC 50 Hz complete all as specified and directed including taking down old unserviceable one. |
| 102 | S&F MCCB, 4 pole, 415 Volts, 200 Amps, 36 kA breaking capacity with thermal and magnetic release including taking down old unserviceable one. |
| 103 | S&F MCCB, 4 pole, 415 Volts,125Amps, 25 kA breaking capacity with thermal and magnetic release including taking down old unserviceable one. |
| 104 | S&F Booster pump pressure switch complete all as specified and as directed.Make-Danfoss or equivalent. |
| 105 | Taking up or down the defective booster pump of any make 240 volt single phase 01 HP by dismantling the electrical connections, removing the motor by decoupling with pump, transporting to workshop, dismantling it completely, removing the burnt out winding, rewinding the same with super enameled copper wire of existinggauge replacementof unserviceable part includingbearing and with necessary insulating material, varnishing, backing and re assembling the serviceable motor completely withall connections complete all as specified and as directed by Engr-in-charge.Note : (i)Burnt out removed winding wire shall be property of contractor and shall be paid under schedule of credit. |
| 106 | Taking up or down the defective Centrifugal pump of any make 415 volt Three phase 05 HP by dismantling the electrical connections, removing the motor by decoupling with pump, transporting to workshop, dismantling it completely, removing the burnt out winding, rewinding the same with super enameled copper wire of existinggauge replacementof unserviceable part includingbearing and with necessary insulating material, varnishing, backing and re assembling the serviceable motor completely withall connections complete all as specified and as directed by Engr-in-charge.Note : (i)Burnt out removed winding wire shall be property of contractor and shall be paid under schedule of credit. |
| 107 | M&L for Brim media for iron removal plant used with black granular filter material for removal of iron or manganese from water in pressure or gravity system from 12000 LPH plant including two coats of synthetic aluminium paint above one coat of red oxide primer complete all as specified and as directed. |
| 108 | M&L for Brim media for iron removal plant used with black granular filter material for removal of iron or manganese from water in pressure or gravity system from 5000 LPH plant including two coats of synthetic aluminium paint above one coat of red oxide primer complete all as specified and as directed. |
| 109 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and directed. |
| 110 | Material and labourfor spraying herbicide on area to remove unwanted vegitation/grass at various locations as directed by Engr-in-Charge |
| 111 | Supply only steel wire brush 90 Cm long and 7.5 cm width, PVC/ wooddenhandle to clean the surface area of filteration plant complete all as directed. |
| 112 | Material and labour for vibratory compactive,precast cement concrete rubber moulded, coloured ( except grey colour), interlocking designer paver blocksin Milano shape, comfirming to IS-15658-2006 of 60 mm thickness, M-35 grade, as in path, hardingstanding, etc laid over and including 25 mm compacted sand cushioning, including 75 mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate including surface excavationover area n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil and removing excavated soil exc. 50 mtr but n. exc. 250 mtr, complete all as specified and directed by Engineer-in-charge. |
| 113 | Supply and laying in replacement ductile iron pipe, S/S including special class K-9, 250mm dia complete including fittings andtaking down old/damaged pipe line complete all as specified and directed by Engr-in-charge. |
| 114 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed. |
| 115 | M&L cutting/ boring of existing road/hard standing// footpath surfaces for laying of GI water tubing complete all as specified and as directed. |
| 116 | Returning,filling intrenches including spreading,leveling,watering and well ramming in layers not exceeding 25 Cm thickasinsoft/loose/hard/dense soil complete all as directed by Engr in Charge. |
| 117 | Removing excavated materials to a distancenot exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting pointcomplete all as directed by Engr in Charge. |
| 118 | Material and labour sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cmsdeep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and as directed. |
| 119 | Supply and lay bricks, common burnt clay, sub class \"B\", old size, laid in vertical direction to cable as cable protection complete all as specified and as directed. |
| 120 | M& L in replacement of RCC Over head water level indicator suitable for RCC/ PS Over head water tank (20 Mtr height) consists scale board , pointer, pulley, connection pipe, wire rope, float, guiding flange, anchor plate etc including all accessories complete all as specified and directed |