Tender for Supply of equipment / material, design, erection, testing, commissioning for providing S.O.P. to newly constructed residential building at NIFT Campus Chebb at Kangra under ESD No. I HPSEBL, Kangra-Material/Erection of 11/0.4KV,250 KVA S/Stn. 2 Prov.Distribution Transformer (Ordinary), 11/0.4 kV,250 KVA 3 Prov.Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) 4 Prov.X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 5 Prov.MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LAs 6 Prov.X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 7 Prov.X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for Transformer Bed 8 Prov.X-Arm [Channel Iron (100x50x5 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer] 9 Prov.MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos 10 Prov.MS Angle Iron (35X35x6 mm), Length : (460 ) x 2 Nos 11 Prov.MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing 12 Prov.MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos 13 Prov.MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos 14 Prov.GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm 15 Prov.D.O Fuse Unit 16 Prov.Surge Arrester, 9 kV Station Class(Porcelain Type) 17 Prov.Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12kV, 90 kN) including Dead End Clamps etc.) 18 Prov.Pipe Earthing Set 19 LT Distribution Panel Box with MCCB(630A, 50 kA, 3P,1 no) and MCCB(250 A, 36KA, 3P, 3 No.) 20 Prov.Half Clamp (M.S. Flat 50X6 mm) 21 Prov.Full Clamps (M.S. Flat 50X6 mm) 22 Prov.Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more(with flat and spring washers)] 23 Aluminium Thimble 24 Copper Thimble 200 Amp 25 Danger Plate 26 Prov.Barbed Wire 27 Prov.Energy Meter (3-Phase,4-wire)DLMS compliant 400/5A CT Type 28 Prov. Aluminium Paint. 29 Prov.AAAC 7/3.15mm² Conductor for Earthing 30 Erection charges complete in all respect 31 Transportation charges complete in all respect 32 (B)Material/Erection of 11 KV HT Line 33 Prov AAAC 7/3.15mm² Conductor (50mm²) {Includes Cutting and wastage} 34 Prov. Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) 35 Prov.M.S. C.I.X-Arm (1500x100x50x5 mm), Long for single pole 36 Prov.M.S A.I X-Arm (1800x50x50x6 mm),Long For Single Pole 37 Prov M.S A.I X-Arm (50x50x6 mm), Length (2x750) mm Long For Single Pole 38 Prov M.S A.I X-Arm (50x50x6 mm),Length (2x600) mm Long For Single Pole 39 Prov.M.S C. I Cross Arm (75x40x5 mm), Length (2400) mm For G.O Switch & D.O Fuses 40 Prov.Belt Set - MS A.I 50x50x6, Length [2400 mm x 2 No.] for Double Pole 41 Prov.X-Bracing Set - MS A.I 50x50x6, Length [2700 mm x 2 No.]for Double Pole 42 Prov 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN) 43 Prov Disc insulator ,1 No Disc (12 kV, 90 kN) including Dead End Clamps etc. 44 Prov HT Earthing set complete 45 Prov Double Continous Earth wire (GI, 8 SWG) @ 0.102 kg/m 46 Prov Danger Plate (250X200X1.6 mm) 47 Prov Nuts and Bolts of Various Sizeswith flat and spring washers 48 Prov Barbed Wire 49 Prov Aluminium Paint 50 Prov.Full Clamps (M.S. Flat 50X6 mm) 51 Prov.Xerox for Chebb S/Stn for SCADA 52 Prov.D.O Fuse Unit 53 Erection charges of 9 mtr ST Polecomplete in all respect 54 Erection charges of Stay Setcomplete in all respect 55 Erection charges of Coil earthing complete in all respect 56 Erection charges of G.O. switch complete in all respect 57 Erection charges of Sagging AAAC 7/3.15mm²Conductor 58 Sagging of Continous Earth Wire (GI, 8SWG) @ 0.102 kg/m complete in all respect 59 Transportation charges complete in all respect 60 commissioning of a 250 KVA DTR plinth and fencing 61 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 62 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) 63 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 64 Providing and laying cement concrete 1:2:4( 1 cement, 2 sand, 4 graded stone aggregate 20mm NS) and curing complete in plinth and foundation 65 Providing mild steel/Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level. 66 Centering and shuttering including strutting, propping etc and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 67 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 68 Extra for providing and fixing expanded metal mesh of size 20x60 mm and strands 3.25 mm wide 1.6 mm thick weighing 3.64 kg per sqm for encasing of rolled steel sections in beams, columns and grillages, excluding cost of hangers. 69 Painting (two coats) excluding priming coat onnew steel and steel based surface after and i/c preparing the surface by thoroughly cleaning, oil, grease, deit and other foreign matter sand papering and stopping with ready mixed paint other than white 70 P/F oxidised M.S. sliding door bolt anodized colour & shade with bolts & nuts screws etc. complete (250*16mm) 71 P/F oxidised M.S. handle with necessary screws etc. complete (125mm)