Tender For Special Repair To Lt Overhead Line To Lt Ug Cable With Steel Tubular Poles And Its Connected Items At Bhalukmara Under Ge Jorhat., jorhat-Assam

Military Engineer Services has published Tender For Special Repair To Lt Overhead Line To Lt Ug Cable With Steel Tubular Poles And Its Connected Items At Bhalukmara Under Ge Jorhat.. Submission Date for this Tender is 09-07-2025. Overhead Line Tenders in jorhat Assam. Bidders can get complete Tender details and download the document.




Tender Notice

49748187
Tender For Special Repair To Lt Overhead Line To Lt Ug Cable With Steel Tubular Poles And Its Connected Items At Bhalukmara Under Ge Jorhat.
Tender
Indian
Assam
Jorhat
09-07-2025

Tender Documents

Tender Details

Tender For Special Repair To Lt Overhead Line To Lt Ug Cable With Steel Tubular Poles And Its Connected Items At Bhalukmara Under Ge Jorhat.; 1 Excavation in trenches, not exc. 1.5 m wide and not exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying pipe, cable, etc. n exc 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft/ loose soil, complete all as specified and directed. 2 Returning filling in soft/ loose soil, including spreading, levelling, watering and well ramming in layers not exc. 25 cm, complete all as specified and directed. 3 Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed. 4 Material and labour for, sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed.(NOTE : For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for). 5 Material and labour for, sub class B brick, well burnt, old size, flat, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and directed. 6 Labour only for manual horizontal boring under a depth of 0.65m for passing of GI cable protection pipe upto 50mm bore dia, under road/ foot path not exc. 6.00m in a single length, complete all as directed. 7 Supply, laying, testing commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 2 core, complete all as specified and directed. 8 Supply, laying, testing and commissioning of XLPE insulated, screened, PVC badded, galvanised steel strip or wire,armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm 4.0 core, complete all as specified and directed. 9 Supply, laying, testing and commissioning of XLPE insulated, screened, PVC badded, galvanised steel strip or wire,armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 4.0 core, complete all as specified and directed. 10 Supply, laying, testing and commissioning of XLPE insulated, screened, PVC badded, galvanised steel strip or wire,armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm 3.5 core, complete all as specified and directed. 11 Supply, laying, testing and commissioning of XLPE insulated, screened, PVC badded, galvanised steel strip or wire,armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm 3.5 core, complete all as specified and directed. 12 Supply, laying, testing and commissioning of XLPE insulated, screened, PVC badded, galvanised steel strip or wire,armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm 3.5 core, complete all as specified and directed. 13 Supply and fix for, 100 watts LED high bay light made of pressure die cast aluminium housing with integrated polycarbonate IP lens cover, IP66 protection, cradle and eye bolt both arrangements should be provided for mounting with additional safety chain and system efficacy should be greater than 130 Lumen per watt and LM79 report should be provided from NABL accredited lab. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection and external 10KV surge protection inside luminaire housing for trouble free service life. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till lifeall as per Cat No.SLE RSB 100W ORION PRO of M/s Surya Pvt Ltd or equivalenr model of make specified in PS. Warranty should be 5 years and warranty certificate should be provided on OEM letterhead at the time of delivery including provision of ladder upto 16 metres height for fixing of light, complete all as specified and directed. 14 Supply and fix in repairs for, LED street light fittings of 70W made of pressure die cast aluminium housing with toughened glass cover, IP66 protection, high power LEDs with secondary lenses and system efficacy should be minimum 110 Lumen per watt and LM79 report should be provided from NABL accredited lab. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection and external 10KV surge protection inside luminaire housing for trouble free service life all as per Cat No.SLE UL 70W IP66 NGL of M/s Surya Pvt Ltd or equivalenr model of make specified in PS . THD shall be <10%, Power Factor >0.95, CCT 5700K and Brand name should be embossed/engraved on the LED fitting for traceability till life. Warranty should be 2 years and warranty certificate should be provided on OEM letterhead at the time of delivery, complete all as specified and directed. 15 Supply and fix for, 200 watts LED flood light made of pressure die cast aluminium housing with integrated polycarbonate IP lens cover, IP66 protection and system efficacy should be greater than 120 lumen per watt and LM79 report should be provided from NABL accredited lab. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection and external 10KV surge protection inside luminaire housing for trouble free service life. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till life all as per Cat No.SLE FL 200W IP66 RADIANCE of M/s Surya Pvt Ltd or equivalenr model of make specified in PS. Warranty should be 02 years and warranty certificate should be provided on OEM letterheadat the time of delivery, complete all as specified and directed. 16 Supply and fix for, street light bracket, fabricated out of 40mm bore GI tubing medium grade, 1.5m length bend to the shape, mounting with MS clamp of flat iron size 40 x 5mm of suitable length 2 pairs including nut and bolts etc suitable size as directed, complete all as specified and directed. 17 Material and labour for, PVC insulated multicore FR PVC sheathed 1.5 sqmm 3 core multi stranded copper conductor for connection of security light from Junction Boxto security light, complete all as specified and directed. 18 Supply and fix for, sub main wiring with two runs of single core 2.5 Sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed, 1100 volts grade IS-694 marked drawn through and including not less than 20mm dia rigid PVC conduit, (heavy duty) (ISI marked)surface type withall accessories such as junction boxs, bends, tees etc. including one run of single core 2.5 Sqmm (nominal area) PVC insulated copper conductor FRLSH, unsheathed strandedas continuous earth wire, complete all as specified and directed. Notes: (i) All runs of copper conductor and one run of conduit shall be measured as one unit length.(ii) Extra length of cables/ wire required for connection to MCBs/ DBs shall not be measured and the unit rate quoted by contractor shall be deemed to be included. 19 Supply installation, testing and commissioning including providing all necessary electrical connection, factory made LT feeder pannel boad (CPRI Approved), outdoor type, double door, made out of 3.15mm thick MS sheet of size 1.5 m x 1.2 mx 0.60m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 Nos legs of 0.6m above the ground with cable entry and exit circular hole with cable gland and gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick, fixing lugs, bolts, screws etc., complete all as specified and directedand comprising of the following accessories:- (a) Copper bus bar of capacity 500 Amp - 03 Nos (R-Y-B) and 250 Amp - 01 No. (Neutral)(b) MCCB of 4 poleof capacity 320 Ampswith breaking capacity of 50 KA (Thermal setting 100%, Magnetic setting upto 70%) - 01No(c) MCCB 160 Amps (fixed type), 415 Volts 3 pole, 35 KA - 01 No (d) MCCB 63 Amps (fixed type), 415 Volts 3 pole, 25 KA - 01 No (e) MCCB 40 Amps (fixed type), 415 Volts 3 pole, 10 KA - 04 No (f) MCB TPN 6 Amps, 10 KA, C curve - 01 No (g) 3 Phase LED digital multifunction meter, Model C, Class 1- 01 No.(h) Time switches 415 volt three phase of 20 Amps rating with contactor and RPN MCB 20Amp fitted inside steel enclosure - 01 Set 20 Supply installation, testing and commissioning including providing all necessary electrical connection, factory made LT feeder pannel boad (CPRI Approved), outdoor type, double door, made out of 3.15mm thick MS sheet of size 0.75 m x 0.60 mx 0.60m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 Nos legs of 0.6m above the ground with cable entry and exit circular hole with cable gland and gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick, fixing lugs, bolts, screws etc., complete all as specified and directedand comprising of the following accessories:- (a) Copper bus bar of capacity 200 Amp - 03 Nos (R-Y-B) and 100 Amp - 01 No (Neutral)(b) MCCB 160 Amps (fixed type), 415 volts, 3 pole, 25 KA - 01 No (In coming)(c) MCCB 80 Amps (fixed type), 415 volts, 3 pole, 16 KA - 02 Nos (d) Indicator lamp LED type (set of three red,yellow, blue) - 01 No.(e) 3 Phase LED digital multifunction meter, Model B, Class 1- 01 Nos 21 Supply and fix for, LT electrical bus bar box of size 600 x 600 x 450 mm factory made cubicle of thickness 3.15 mm CRCA, copper bus bar of size 400 Amps , (R, Y, B, N) duly insulated with proper colour code base frame with 04 Nos MS iron angles, sloping canopy top roof,floor mounted, dust and vermin proof both side openable hinged double door with pad lock arrangement, front side operatable detchable gland plate at bottom for cable entry/ exit, all opening will be covered with rubber gasket, danger notice plate M.S 200 x 150 x 1.6 mm, RAL- 7032 shade internal wiring all complete with following accessories:- (a) Provision of 01 No. MCCB 250 Amps,25KA capacity - 01 No. (b) Indication LED lamp (R,Y,B) - 01 Set 22 Supply and fix for, LT electrical bus bar box of size 600 x 600 x 450 mm factory made cubicle of thickness 3.15 mm CRCA, copper bus bar of size 200 Amps , (R, Y, B, N) duly insulated with proper colour codebase frame with 04 Nos MS iron angles , sloping canopy top roof, floor mounted, dust and vermin proof both side openable hinged double door with pad lock arrangement, front side operatable detchable gland plate at bottom for cable entry/ exit, all opening will be covered with rubber gasket, danger notice plate MS 200 x 150 x 1.6 mm, RAL- 7032 shade internal wiring all complete with following accessories:- (a) Provision of 01 Nos of MCCB 160 Amps,25KA capacity - 01 No. (b) Indication LED lamp (R,Y,B) - 01 Set 23 Supply and fix for, sheet metal enclosure for DBs when MCBs to be used, TPN 415 volts, 4 way 200 Amps rated bus bar, metal double door type IP-43, complete all as specified and directed.Note:- MCBs will be measured and paid seperately under relevant item. 24 Supply, fixing, testing andcommissioning for, 6 to 32 Amp, SP 240 volts 10KA C curve miniature circuit breaker (MCB),complete all as specified and directed. 25 Supply, fixing, testing andcommissioning for, 100 Amp, TPN 415 volts 10KA C curve miniature circuit breaker (MCB),complete all as specified and directed. 26 Supply and fix for, 50 mm dia HDPE pipe, PN-10 for cable protection on pole/ wall/ floor or in trenches and drain/ culvert etc. complete with necessary clamp, nuts, bolts, washers, sockets etc., complete all as specified and directed. 27 Supply and fix for, 75 mm dia HDPE pipe, PN-10 for cable protection on pole/ wall/ floor or in trenches and drain/ culvert etc. complete with necessary clamp, nuts, bolts, washers, sockets etc., complete all as specified and directed. 28 Supply and fix for, steel tubing of size 25 mm dia , light grade with all fittings for cable protection, fixing on street light poles including GI clamps, nuts & bolts and washers, complete all as specified and directed. 29 Material and labour for, cutting the road/ hard standing (hard/ dense soil) at the road crossing for the fixing of pipe, complete all as directed. 30 Material and labour for, PCC (1:3:6) type (using 40 mm graded stone aggregate) for making good the disturbed surfaces for fixing of pipe at road cutting portion, complete all as directed by Engr-in-charge. 31 Material and labour for, earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.50 metre below normal ground level connected to galvanised steel earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised steel and connected to main switch boardor main control board as directed and including provision of concrete earth pit in PCC (1:3:6) type C1, 50mm thick pre-cast RCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) cover slab (Reinforced with 8mm dia TMT bar @15cm centre to centre bothways and suitable handle made of 10mm dia), provision of funnel, wire mesh, 20mm bore galvanised steel tubing (medium grade) for watering, charcoal or coke and salt in alternate layers of 15cm (compacted thickness), 15mm bore galvanised steel tubing (light grade) for protection of earth lead connection, necessary excavation and earth work in any type of soil complete all as specified and indicated on electrical plate No.3 of SSR Part-I (2009) including testing on completion.(Note: GI earth wire and protection pipe upto 7.5metres shall be deemed to be included in the unit quoted rate). 32 Material and labour for, earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.50 metre below normal ground level connected to galvanised steel earth lead strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanised steel and connected to main switch boardor main control board as directed and including provision of concrete earth pit in PCC (1:3:6) type C1, 50mm thick pre-cast RCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) cover slab (Reinforced with 8mm dia TMT bar @15cm centre to centre bothways and suitable handle made of 10mm dia), provision of funnel, wire mesh, 20mm bore galvanised steel tubing (medium grade) for watering, charcoal or coke and salt in alternate layers of 15cm (compacted thickness), 40mm bore galvanised steel tubing (light grade) for protection of earth lead connection, necessary excavation and earth work in any type of soil complete all as specified and indicated on electrical plate No.3 of SSR Part-I (2009) including testing on completion.(Note: GI earth wire and protection pipe upto 7.5metres shall be deemed to be included in the unit quoted rate). 33 Supply and fix for, cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrinkable type and accessories suitable for 3 ½ / 4 core XLPE, armoured, aluminium conductor cable of size 35 to 70 sqmm, indoor/ uutdoor type all as specified and directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 58000.0 /-
Tender Value
INR 29 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail