}

Construction Of Water Supply Scheme Langate Town Under Amrut 2.0 Town Under Amrut -2.0, Baramulla-Jammu And Kashmir

Public Health Engineering Department has published Construction Of Water Supply Scheme Langate Town Under Amrut 2.0 Town Under Amrut -2.0. Submission Date for this Tender is 24-06-2025. Water Supply Project Tenders in Baramulla Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

49740084
Construction Of Water Supply Scheme Langate Town Under Amrut 2.0 Town Under Amrut -2.0
Tender
Indian
Jammu And Kashmir
Baramulla
24-06-2025

Tender Details

Construction of Water Supply Scheme Langate Town under Amrut 2.0 Town under AMRUT -2.0- 1 Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains,pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspitsand the like not exceeding 10 sqm on plan,including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: 2.9.1 All kinds of soil : 2 Ordinary Rock 3 Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth asdirected: 4 Ordinary Rock 5 Earth work in bulk excavation by mechanical means(hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) includingdisposal of excavated earth lead upto 50meters and lift upto 1.5 m,as directed by Engineer-in-Charge. 2.7.1 All kinds of soil : 6 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 7 Providing and laying S&S Centrifugally Cast (Spun)/ Ductile Iron Pipes conforming to IS : 8329 19.63.1 100 mm dia Ductile Iron Class K - 7 Pipes 8 150mm dia ductile iron Class K-7 pipes 9 200mm dia 10 300mm dia 11 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately).80mm dia 12 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately).Class ii 100mm dia 13 150mm dia 14 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately). 80 mm dia. 15 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paidseparately).300mm dia 16 200mm dia 17 Providing and laying D.I. Specials of Class K-12 suitable for push-on jointing as per IS : 952319.59.1 Upto 600 mm dia. 18 Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps etc (Heavy class) 19.19.1Up to 300 mm dia. 19 Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 20 50mm GI pipes 21 25mm 22 80mm 23 Making connection of G.I. distribution branch with G.I. main offollowing sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 50 to 80 mm nominal bore 24 Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket.300mm dia 25 200mm dia 26 100mm dia 27 150mm dia 28 Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material :2.10.1 All kinds of soil : 29 Providing and laying of stone soiling incl. ramming consolodating and levelling all complete 30 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 31 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 32 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and strutsupto floor five level including curing but excludingcost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 33 Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. 34 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 35 Suspended floors, roofs, landings, balconies and access platforms. 36 Lintel, beams, plinth beams, girders, bressumers and cantilevers 37 Arches, domes, vaults upto 6 m span 38 Extra for arches, domes, vaults exceeding 6 m span 39 Extra for shuttering in circular work (20% of respective centering and Shuttering items) 40 Foundations fittings basis of columns etc for mass concrete 41 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 42 Arches, domes, vaults upto 6 m span 43 Extra for arches, domes, vaults exceeding 6 m span 44 Lintel, beams, plinth beams, girders, bressumers and cantilevers 45 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured).Suspended floors, roofs, landings, beams and balconies (plan area to be measured) 46 Providing and mixing water proofing material in cement concrete work in doses by weightof cement as per manufacturer’s specification.(1 kg of water proofing material in 50 kg of cement) 47 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 48 Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 49 12mm Cement plasterfinished with a floating coat of neat cement of mix: 1 : 4 ( 1 cement : 4 fine sand) 50 12mm Cement plaster finished with a floating coat of neat cement of mix:1 : 3 ( 1 cement : 3 fine sand) 51 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. 5.34.1All works upto plinth level 52 All works above plinth level upto floor V level 53 Add or deduct for using more or less cement in the items of design mix over and above thespecified cement content therein 54 Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. 55 Providing and fitting steel welded mesh incl. all fittings and carriage complete 56 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). 100 mm dia. 57 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 58 Surface dressing of the ground including removing vegetation and in-equalitiesnot exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil. 59 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 4.4.1DELETED 4.4.21:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) 60 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) 61 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 62 Providing & laying damp-proofCourse 40 mm thickwith cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete 63 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) 64 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level 65 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gram/m2 66 Providing of PGI sheets at construction joints incorporating complete job 67 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) 68 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 69 Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 70 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Second class kail wood 71 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). Second kail wood 72 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Second Class kail wood 73 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm) 74 Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 75x63x3.2 mm 75 Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x63x4 mm 76 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm 77 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :200x10 mm 78 Providing and fixing aluminum round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-charge Anodized (AC 15) aluminum 79 Providing 40x5 mm flat iron hold fast 40 cm long with cement concrete block 30x10x15 cm 1:3:6 mix 80 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 9.40.1 2nd class teak wood 9.40.1.150 x 12 mm 81 Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete.With 2nd class teak wood beading 62x19 mm 82 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. 83 Providing and installing UPVC pipes (working pressure) 4kg/cm2) single socketed pipe 110mm dia pipe with all necessary arrangements and fittings incl. TEES, elbows and end caps where ever required complete job 84 Providing and fixing brass bib cock of approved quality 20mm nominal bore 85 Providing and fixing brass stop cock of approved quality. 86 Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors whereverrequired: 18.3.1 W.C. pan with ISI marked white solid plastic seat and lid. 87 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever required :White Vitreous China Surgeon type wash basin size 660x460mm with a pair of 15 mm C.P. brass pillar taps with elbow includingoperated levers. 88 Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C waste fittings complete: 32mm dia 89 Bottle Trap 90 Fixing white vitreous china pedestal for wash basin. 91 providing and installing 25 Ltr gysrer /water heater with all necessary arrangements complete 92 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as perI.S. 13983 with C.I. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the wallswherever required : 510x1040mm bowl depth 200mm 93 Construction of Septick Tank as directions by Site Engineer complete job 94 Carriage of materials by mechnincal means savg lead 20km Cement , GI/CI/AC Staineless Steel andCC pipes below 100mm dia stone blocks and other heavy material stone blocks GI/CI/AC Staineless Steel andCC pipes below 100mm dia and other heavy material 95 Carriage of material by mechanical transport avg lead 20km 96 Stone Soiling 97 Stone aggrgate 40mm45km 98 Stone aggrgate 20mm45km 99 Bricks 100 Carriage of materisl by mechanical transport incl. laoding unloading and stacking 15km avg lead 101 RCC pipes AC pipes steel cylender Rc pipes GI pipes Di pipes Ms pipes Ci pipes and un raeinforced cement pipe 30mm dia ductile iron pipe 102 200mm dia 103 Carriage of materials by manual labour incl. laoding unloading and stackign avg lead 300mtr200mm dia DI 104 300mm dia DI 105 RCC pipes AC pipes steel cylender Rc pipes GI pipes Di pipes Ms pipes Ci pipes and un raeinforced cement pipe 30mm dia ductile iron pipe 106 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required Group B 107 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 108 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 109 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 110 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required (32MM) 111 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 112 5/6 A switch 113 3 pin 5/6 A socket outlet 114 15/16 A switch 115 6 pin 15/16 A socket outlet 116 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 117 Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ianored) 118 Installation, tèsting and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq mm FRLS PVC insulated, copper conductor, single core cable etc as required. 119 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. 120 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as requiredUpto 450 mm sweep 121 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required 122 32A TP&N 123 63A TP&N 124 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 6 way , Double door 125 Providing & Installing 8W Round Led Ceiling Light Complete job. 126 Providing & Installing 200mm Exhaust Fan| Cut Out Size: 9.4x9.4 square inches| Watt: 32| RPM: 1350| Air Delivery: 520| Suitable for Kitchen, Bathroom, and Office 127 Providing & Installing Electric Ceiling Fan | 1200mm BEE Star Rated Ceiling Fan 128 Operation & Maintenace Charges@5% of Adv Cost of Quantities (Civil & Mechanical Components) 129 For Ist Year 130 For 2nd Year 131 For 3rd Year 132 For 4th Year 133 For 5th Year

Key Value

Document Fees
INR 1000 /-
EMD
INR 1457460.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail