Replacement/ Installation Of Air Conditioners At Various 765 Kv And 400 Kv Gss Of Jaipur Zone Replacement/ Installation Of Air Conditioners At Various 765 Kv And 400 Kv Gss Of Jaipur Zone , Supply , Installation, Testing And Comissioning Of Air Cooled Cassette Typeair Conditioners Complete With Indoor Unit(Idu), Out Door Unit (Odu), R-32/R410a Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230V, +/- 10% 50 Hz ,1 /3 Phaseacsupply, Apable Of Performing Cooling, Dehumidification,Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll /Rotary/Twin Rotary Compressor. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . Inverter Type 3.8 / 4.0 Tr (E-22.27.1.7) , Supply , Installation, Testing And Comissioning Of Air Cooled Cassette Typeair Conditioners Complete With Indoor Unit(Idu), Out Door Unit (Odu), R-32/R410a Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230V, +/- 10% 50 Hz ,1 /3 Phaseacsupply, Apable Of Performing Cooling, Dehumidification,Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll /Rotary/Twin Rotary Compressor. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . Inverter Type3.0 Tr(E-22.27.1.7) , Supply , Installation, Testing And Comissioning Ofinverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And50 Hz , Single Phaseacsupply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr .2.0 Tr Iseer Not Less Then 4.6 (E-22.24.8) , Supply , Installation, Testing And Comissioning Ofinverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And50 Hz , Single Phaseacsupply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . 1.5 Tr Iseer Not Less Then 4.6 (E-22.24.4) , Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping Withfittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing,Support With Ms Hanger On Ceiling Or Recessed In Wallwith Chasing & Plastering With 6 Mmthickclosedcellelastomeric Nitrile Rubberinsulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . 20 Mm (E-22.40.1) , Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrialplug Top Making Connection Etc Complete In All Respect.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . 5 Kva (E-22.41.3) , P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 Forlower Watt Loss , Oxygen Freefor Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5,Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr.2.5 Sq.Mm 3 Core Flat / Round(E-4.7.2) , Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 100 Mm Dia Per Running Inch Length (E-22.42.2) , Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . (E-22.45) , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load Andsite Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Ofclass 3 As Per Iec,Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted Inexisting Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Ratingincluding Making Connections, Testing Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Reports& All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Single Pole Mcb (With B/C Curve Tripping Characteristics)6 A To 32 A Rating (E-6.1.1.2) , Sitc Of3 /4Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Materialhaving Following Current Rating, Short Circuitbreaking Capacityat 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Frontface And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator,Line Load Interchangeability,Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree,Pollution Degree 3, Having Positive Isolation Capability, Push(Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Imp =8 Kv, Rated Insulation Voltage690 V.Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connectionsetc. As Required.Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 3 Pole Mccb With Thermal Magnetic Release Up To 100 Amp , 10 Ka, Fixed O/L & Fixed S/C Setting (E-9.3.1.2) , P&F Metal Clad / Plastic Industrial Plug Top & Socket Unit With Pin And Sleeve Type Contact On Porcelain/ Bakelite Base In Recessed/Surface Mounting Heavy Duty Enclosure Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted (Without Mcb) Including Making Connections, Testing Etc.As Required.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 20 Amp, 2 Pin + Scrapping Earth, 1 Module (E-6.13.1) , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 Forlower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5,In Existingsurface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. (E-4.1.14) , S&F Following Sizesof Isi Marked ( Is:14927 P - Ii ) Virgin Materialupvc Trunking Along With Accessorieslike Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surfacewithscrews, Expansionfastenersas Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 32 Mm X 12 Mm (E-3.4.3) , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmouredaluminiumcable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv Withh4- Grade Electrolyticaluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Includingtesting Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 16 Sq Mm 3 Core(E-11.2.4.2) , Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . (A)12.7 Mm O.D., Wall Thinkness = 0.8Mm (Insulation – 13 Mm Thick) 22.39.9 , Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . ( B) 15.9 Mm O.D., Wall Thinkness = 0.8Mm (Insulation – 13 Mm Thick) 22.39.8 , Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . (C) 6.40 Mm O.D., Wall Thinkness = 0.8Mm (Insulation – 13 Mm Thick) E22.39.11 , Supply & Fixing Ms Powder Coated Stand Suitable For 2.5/3.0/4.0 Tr Outdoor Type Of Split/Ductable/Tower Ac.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . 22.46 , E-6.13.3P&F Metal Clad / Plastic Industrial Plug Top & Socket Unit With Pin And Sleeve Type Contact On Porcelain/ Bakelite Base In Recessed/Surface Mounting Heavy Duty Enclosure Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted (Without Mcb) Including Making Connections, Testing Etc.As Required.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 20 Amp, 3 Pin + Scrapping Earth, 4 Module , E-6.2.1.2 Providing & Fixing Of 240/415 V Isolatorisi Marked Is:13947-Iii/Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage,True Contact Indication,Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting,Minimum Phase Termination Capacity Of 35Sq.Mm.Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheetincluding Making Connections, Testing Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Reports& All As Per Pre Approved Byengineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Double Pole Isolator 63 A Rating , Replacement Of Defective Compressor By Company Repaired Compressor As Per Oem Recommendationsof Following Gadgets Including Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 2.0 Tr A.C .E-26.43.3