| 1 | 2024-25 Sustainability support to Kuntar WSS |
| 2 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 3 | 13.37.1 : White washing with lime to give an even shade:New work (three ormore coats) |
| 4 | 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 5 | 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 6 | 13.71 : Lettering with black Japan pint of approved brand and manufacture |
| 7 | 22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 8 | 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 9 | Sustainability Support to Vivekananda WSS |
| 10 | od51918/2024_2025 : Suitable HP (IS; 8034) borewellsubmerssible 3phase electric driven motor pumpset working at 360 voltage with bronze impeller and stainless steel shaftwith suitable ISI marked accessories such as starter(best quality ISI marked fully automatic electronic Star Delta ), main switch ,fuse, capacitor, ELCB, adequate length of best quality suitable size flat submerssible cable, reflux valve, sluice valve, pressure gauge, earthing materialsconforming to IS 3043/2000 as amended to date, ammeter, volt meter, selector switch, flickering lamps, dry running preventer cum no voltage wire, conveying and erecting the motor pumpset and panel board and giving all connections, earthing etc. as per KSEB/EI rules and regulations. Conveying and fixing suitable GI pipe medium pipe as suction and delivering pipes including connections with pumpset delivery to the common pumping main of suitable size using suitable T/Y connections etc,.Trial run should be given for 7 days. Any documentation required for proper electric connection shall be arranged by the contractor at their own cost etc. complete as per direction of site in charge of the work. |
| 11 | 18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore |
| 12 | 13.37.1 : White washing with lime to give an even shade:New work (three ormore coats) |
| 13 | 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 14 | 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 15 | 13.71 : Lettering with black Japan pint of approved brand and manufacture |
| 16 | 22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 17 | 100.98.192 : Supply of PE Pipe, PE100, PN16, 63mm dia, conforming to IS 4984/2016. |
| 18 | 100.9.6 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials).63 mm nominal outer dia pipes. |
| 19 | Providing and fixing of good quality water level indicater with proper markings |
| 20 | 2024-25 Sustainability support to Kaithode SC WSS in Karadukka GP |
| 21 | od60590/2024_2025 : Suitable HP (IS; 8034) borewellsubmerssible 3phase electric driven motor pumpset working at 360 voltage with bronze impeller and stainless steel shaftwith suitable ISI marked accessories such as starter(best quality ISI marked fully automatic electronic Star Delta ), main switch ,fuse, capacitor, ELCB, adequate length of best quality suitable size flat submerssible cable, reflux valve, sluice valve, pressure gauge, earthing materialsconforming to IS 3043/2000 as amended to date, ammeter, volt meter, selector switch, flickering lamps, dry running preventer cum no voltage wire, conveying and erecting the motor pumpset and panel board and giving all connections, earthing etc. as per KSEB/EI rules and regulations. Conveying and fixing suitable GI pipe medium pipe as suction and delivering pipes including connections with pumpset delivery to the common pumping main of suitable size using suitable T/Y connections etc,.Trial run should be given for 7 days. Any documentation required for proper electric connection shall be arranged by the contractor at their own cost etc. complete as per direction of site in charge of the work. |
| 22 | od60624/2024_2025 : Supplying and fixing Water Meter, Indian Standard, Class B, Multijet, 15mm ( 1/2 inch )<br>including the Surface box in the existing house connection and making the loop for fixing<br>the water meter - tracing, locating and exposing the service line at the required place<br>including earth work excavation, cutting and removing the service line portion and making<br>the connection functional including cost of all specials, labour charges etc complete.<br> |
| 23 | 100.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR) |
| 24 | 100.98.229 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 20mm. |
| 25 | 100.98.231 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 32mm Dia. |
| 26 | 100.98.233 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 50mm Dia. |
| 27 | 100.98.235 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 75mm Dia. |
| 28 | 100.9.1 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).20 mm nominal outer dia pipes. |
| 29 | 100.9.3 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).32 mm nominal outer dia pipes. |
| 30 | 100.9.5 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes. |
| 31 | 100.9.7 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials).75 mm nominal outer dia pipes. |
| 32 | 18.12.7 : Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore |
| 33 | 18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore |
| 34 | 100.98.192 : Supply of PE Pipe, PE100, PN16, 63mm dia, conforming to IS 4984/2016. |
| 35 | Tank maintanace works |
| 36 | 13.37.1 : White washing with lime to give an even shade:New work (three ormore coats) |
| 37 | 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 38 | 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 39 | 13.71 : Lettering with black Japan pint of approved brand and manufacture |
| 40 | 22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 41 | Pump House |
| 42 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 43 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 44 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 45 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size |
| 46 | Hydrogeological survey |
| 47 | Drilling of borewell of caising pipe 180mm |
| 48 | Good quality cable for motor |
| 49 | Providing and fixing MS sheet,sheet frame , roof sheet for pump house |
| 50 | 2024-25 Sustainability support to Koyakudlu SC WSS |
| 51 | od60462/2024_2025 : Supplying and fixing Water Meter, Indian Standard, Class B, Multijet, 15mm ( 1/2 inch )<br>including the Surface box in the existing house connection and making the loop for fixing<br>the water meter - tracing, locating and exposing the service line at the required place<br>including earth work excavation, cutting and removing the service line portion and making<br>the connection functional including cost of all specials, labour charges etc complete.<br> |
| 52 | od60463/2024_2025 : Suitable HP (IS; 8034) borewellsubmerssible 3phase electric driven motor pumpset working at 360 voltage with bronze impeller and stainless steel shaftwith suitable ISI marked accessories such as starter(best quality ISI marked fully automatic electronic Star Delta ), main switch ,fuse, capacitor, ELCB, adequate length of best quality suitable size flat submerssible cable, reflux valve, sluice valve, pressure gauge, earthing materialsconforming to IS 3043/2000 as amended to date, ammeter, volt meter, selector switch, flickering lamps, dry running preventer cum no voltage wire, conveying and erecting the motor pumpset and panel board and giving all connections, earthing etc. as per KSEB/EI rules and regulations. Conveying and fixing suitable GI pipe medium pipe as suction and delivering pipes including connections with pumpset delivery to the common pumping main of suitable size using suitable T/Y connections etc,.Trial run should be given for 7 days. Any documentation required for proper electric connection shall be arranged by the contractor at their own cost etc. complete as per direction of site in charge of the work. |
| 53 | 100.60.12.3.2 : Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of consumables, hire charges for tools and labour charges etc. complete, but excluding cost of materials and as per the direction of departmental officers. |
| 54 | 100.98.234 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 63mm Dia. |
| 55 | 100.9.6 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials).63 mm nominal outer dia pipes. |
| 56 | 100.98.192 : Supply of PE Pipe, PE100, PN16, 63mm dia, conforming to IS 4984/2016. |
| 57 | Pump Houe |
| 58 | 12.1.2 : Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating less than 275 gm/m2 |
| 59 | 4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 60 | 50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 61 | Providing and fixing good quality ISI marked HDPE tank including foundation |
| 62 | Drilling of bore well of caising pipe dia 180mm |
| 63 | Providing and fixing good quality cable for motor |
| 64 | Hydrogeological survey |