}

Tender For Work Of Installing High Mask Lights In Harpalsar - Supply Installationtesting&Commissioningof Highmasf Lighting System(Asperplg07 Of Ilpuktechinicalreportno7ofileukis:875Par 1-2015//B Sen10025/Andis:2062)Consistlingoftotallyhot Dipgalvanisedbyp, Churu-Rajasthan

Panchayat Raj Department has published Tender For Work Of Installing High Mask Lights In Harpalsar - Supply Installationtesting&Commissioningof Highmasf Lighting System(Asperplg07 Of Ilpuktechinicalreportno7ofileukis:875Par 1-2015//B Sen10025/Andis:2062)Consistlingoftotallyhot Dipgalvanisedbyp. Submission Date for this Tender is 23-06-2025. Street Lighting Tenders in Churu Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

49677074
Tender For Work Of Installing High Mask Lights In Harpalsar - Supply Installationtesting&Commissioningof Highmasf Lighting System(Asperplg07 Of Ilpuktechinicalreportno7ofileukis:875Par 1-2015//B Sen10025/Andis:2062)Consistlingoftotallyhot Dipgalvanisedbyp
Tender
Indian
Rajasthan
Churu
23-06-2025

Tender Documents

Tender Details

Tender For Work Of Installing High Mask Lights In Harpalsar - Supply installationtesting&Commissioningof highmasf lighting system(asperPLG07 of ILPUKtechinicalreportno7ofILEUKIS:875Par 1-2015//B SEN10025/andIS:2062)consistlingoftotallyhot dipgalvanisedbypiecewisesingledippedmethodhighmast, lanterncarriagesuitableforupto12nosluminarieswithweldedarm(excludingluminares),mastheadfr ameassemblywithfullcover, including1No.LED15Wattsaviationobstructionlights, double drum types, double drum types self-sustaining winch, integral power to accessible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightning finial, Stainless steel 6 mm dia.wire ropes (AIS| 316, 7 /19costruction3no. ropefor lanterncarrage&2no. ropeforwinchassembly) foundationbolt, torque limiter, EPRinsulatedPCPsheathed5corex2.5Sq. mmtrailingcable, including an outdoor type control panel for auto on/off, reverse/forward motor operation.Themas tis constructed from mild steel plates(asperis59 6Gr. 510) cut and folded to form a polygonal section, telescopicjointedandweldingasper BS5135etc.asrequiredonExistingFoundation. (SeetableP- 03forspecs.)OEMMusthaveTypetest certificateforwindtunneltest. AllasperpreapprovedbyEnginerincharge.Alasperpreapproredby Engineer charge, For additional technical parameters of products/work , refer Annexure A attached with this BSR , 20.0 Mtr Hm (in 2 section) suitable for 12 No. Luminaries 3 Providing and Laying RCC Foundation for Octagonal /ConicalStreetLightpoles,HighmastPolesasper DrawingattachatTableP-4withFollowingProcedure&AllasperpreapprovedbyEn gineerincharge.For additional technical parameters of products/ work , refer Annexure A attached with this BSR. A)Excavation of Pit for Foundation Size upto required depth from Ground levelB)DressingofPitandDrystonepitching200mmthickincl udingsupplyofstonesandpreparingsurface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD)Reinforcement forR.C.C.workwithTMTbars includingstraightening, cutting, bending, placing in position and binding all complete.E)Centringandshutteringincludingstrutting.proppinge tc.andremovalofformworkforFootingand PedestalF)Providing&Flxingof2no.RequiredSizePLBHDPEPipe &FoundationBoltwithtemplateasperOEM Recommendations.G)ProvidingandLaying ReinforcecementConcreteofM- 25gradeinFootingandPedestal including Curing the foundation for 7 days. 4 Providing&FixingofIK08IP-66protectedhighpowerLEDfloodlightsystemwithsingl epiecePressurediecastaluminiumhousing,toughenedglassdiffuserwit hsuitablelensesonLEDtoachievevariousbeamangles,ofhighpowerLEDof3to5watteach.Integratedpotteddriv erasauniqueBISRnumber havingefficiencymorethan85%andincompliancetoBIScertifie dandTrademark certificate.TheSystemlevelLuminaireefficacy>=125lm/wt.LEDdriver InputVoltageAC120to270VACwithHighvoltageCutoff@>=300VACandAutoresettingSafety.PowerFactor>0.9 5,THD(1)<10% ,drivercurrent<=750mA.drivershouldbePhasetophaseprotectionof440Vfor4Hr s.ElectricalConnector,SurgeProtectionMin>=4KVinternal and10KVexternalbut insidedrivercompartment, Systemlifeof50000Burninghourswith70%oflnitialLumensmaintained,CRl>70andCCT57 00K+355K.ManufacturesWordMark/NameEngraved/EmbossirggScreeenpintiriondiiecastousin gtoallowtraceability/authenticityFixtureshallbelS10322Complianced.OEMMusthaveitsowninhouse NABLlabsetupforalltestingfacilitiesforEEfixtures. 5 High Power LED Flood Light Minimum lumen output 43750 Im 6 Contengency 2%

Key Value

Document Fees
INR 500 /-
EMD
INR 10280.0 /-
Tender Value
INR 5.14 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail