|
| 1 | S&F in replacement Air Release Valve 40 mm double action with two air outlets , ISI marked including jointing materials such as flanges, nuts, bolts, washers, rubber gasket and fixing up in cast iron pipe of any size complete allas specified and as directed. |
| 2 | S&F in replacementcast iron body Non Return Valve, swing horizontal type with rubberised steel ball , flangedtype , fixed between existingpump and delivery pipe line complete all as specified and directed of the following sizes :- |
| 3 | 100 mm bore |
| 4 | 150 mm bore |
| 5 | 200 mm bore |
| 6 | 250 mm bore |
| 7 | S&F in replacementBip taps of size 15 mm, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed including necessary GI fittings complete all as specified and directed. |
| 8 | S&F in replacementFoot Valve ball typewith rubberised steel ball and CI body flanged at the end of the suction line complete all as specified and directed of the following sizes :- |
| 9 | 80 mm bore |
| 10 | 100 mm bore |
| 11 | 150 mm bore |
| 12 | 200 mm bore |
| 13 | 250 mm bore |
| 14 | S&F in replacementSingle core multi stranded copper conductor PVC insulated heavy duty cable of 50 sqmm complete all as specified and directed. |
| 15 | S&F in replacementSluice Valve cast iron body, double flanged, ISI marked (IS-14846), heavy duty, class PN-1.6 gun metal, with non rising spindle of stainless steel, bronze body seat ring and operating handle, including rubber gaskets, nuts, bolts, washers etc \" complete all as specified and directed of the following sizes: - |
| 16 | 80 mm bore |
| 17 | 100 mm bore |
| 18 | 150 mm bore |
| 19 | 200 mm bore |
| 20 | 250 mm bore |
| 21 | 300 mm bore |
| 22 | M&L for construction of valve chamber (in replacement)1200 x 1200 x 1200 mm (internal dimensions), 6 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40x40x6mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in cement mortar (1:6),PCC bed (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) 150 mm thick, cement plastering 15 mm thick in cement mortar (1:4) and applying two coats of synthetic enamel paint over a coat of primer to the steel surfaces including dismantling and removal of old unserviceble valve pit complete all as specified and directed. |
| 23 | All as per Item No7.00 above but of size 900 x 900 x 900 mm (internal dimension) |
| 24 | S&F in replacementMS Pipes with double flanged including bends and fittings of size upto 400 mm dia, 6 mm thick complete for fixing with pump sets suction & delivery line and integrating with main existing Header line including using of gas welding for provision of bends, tees, and other minor modification works required at site complete all as specified and directed. |
| 25 | S&F in replacementMS Pipes with double flanged including bends and fittings of size upto 200 mm dia, 6 mm thick complete for fixing with pump sets suction & delivery line and integrating with main existing Header line including using of gas welding for provision of bends, tees, and other minor modification works required at site complete all as specified and directed. |
| 26 | S&F in replacement butterfly valves gear operated having epoxy coated cast iron body, PN 1.6,ISI marked SGI disc with integral seat of nitrle rubber complete all as specified and directed of the following sizes:- |
| 27 | 80 mm bore |
| 28 | 100 mm bore |
| 29 | 150 mm bore |
| 30 | 200 mm bore |
| 31 | 250 mm bore |
| 32 | 300 mm bore |
| 33 | M&L for rectification of leakages to water supply distribution lines 15 mm to 25 mm dia GI tubing by necessary excavation, returning / filling, removing and dewatering as required tightening of loose joints and all GI fittings as required including threading where required including replacement of all type of GI fittings like Union, sockets , nipple, elbow etc. where required compete all as specified and as directed. |
| 34 | All as per Item No 12.00 above but for GI tubing of size 40 mm to 50 mm dia bore. |
| 35 | All as per Item No 12.00 above but for GI tubing of size 80 mm to 100 mm dia bore. |
| 36 | M&L for attending routine complaints of external water supply like \"No water\", including rectification of minor defects by taking down of existing GI tubing upto 25 mm dia, cutting/ threading and making joints where necessary, cleaning for blockage, opening of float valve of service tanks cleaning and repairing and refixing the same, replacement of jumper valve / packing sheet of gate valves or replace the unsv gate or Globe valves and replacement of UNSV GI fittings where required complete all as specified and as directed |
| 37 | All as per Item No 16.00 above but for GI tubing of size 40 mm to 50 mm dia bore. |
| 38 | Note for item No 12.00 to 16.00:- (i) Complaints pertaining to the above works shall be received and duly recorded by the contractor or their representative in the complaint register at the Water Supply Complaint Cell of AGE E/M No. 1,Filtration Plant. Tradesmen shall be deployed at this location to attend to the complaints (ii) All required stationery such as complaint books, job cards, etc., shall be arranged by the contractor. (iii) Necessary tools and equipment, including ladders (wooden/steel/aluminium of appropriate size), required for attending to the above complaints shall be arranged by the contractor. (iv)All complaints shall be resolved within 12 hours of registration, including Sundays and holidays. In case the contractor fails to rectify the complaint within the stipulated time, a recovery at the rate of Rs. 1500.00 per day per complaint shall be made from the RAR/ Final Bill/ or the next due payment.(v) The cost of excavation and earthwork shall be deemed included in the quoted unit rate. (vi) GI pipe exceeding 1.00m in length (including taking down), when incorporated as part of the rectification work, shall be measured and paid for separately under the relevant items of the BOQ.(vii) The cost of GI pipe upto 1.00m, GI fittings, flanges, socketed clamps, and other accessories required to be replaced during the execution of the job shall be included in the quoted rates. No extra payment shall be made to the contractor on this account. (viii) The rate quoted by the contractor for the above works shall be deemed inclusive of the requirements mentioned above. No extra payment shall be admissible on this account. |
| 39 | M&L for attending breakdown of water supply pipe line and repairs to CI water mains of size 80 mm to 200 mm dia at a given notice including neceassary excavation and earthworkby using T&P such as JCB etcand menpower. Dewatering from the trenches by using pumps etc. rectification of leakages if any, rectify the same by cocking of lead wool, or replacement of run lead joints or replacement of CI Specials or broken pipes etc. complete all as specified and as directed. |
| 40 | All as per item No 17.00 above but for CIwater mains of sizes 250 mm to 400 mm dia |
| 41 | Note for item No 17.00 to 18.00:-(i) The CI Specials, Lead joints cutting of CI pipes etc. shall be measured and paid seperately.(ii) (iv)All complaints shall be resolved within 12 hours of registration, including Sundays and holidays. In case the contractor fails to rectify the complaint within the stipulated time, a recovery at the rate of Rs. 1500.00 per day per complaint shall be made from the RAR/ Final Bill/ or the next due payment. (iii)The Cost of necessary earth work and repair to damaged road shall deemed to be included in the quoted rate by the contractor. No extra payment shall be admissible on this account. |
| 42 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in any type of soil for foundation, laying pipe etc. or for shafts, wells, cesspits, manholes, pier holes, etc. and getting out complete all as specified and directed. |
| 43 | Returning filling in soft/loose soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. |
| 44 | Removing excavated material (Soils) to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed. |
| 45 | Taking up or down existing GI tubing and connections including removal for the following size of pipes complete all as specified and directed :- |
| 46 | 100 mm bore |
| 47 | 80 mm bore |
| 48 | 50 mm bore |
| 49 | 40 mm bore |
| 50 | 25 mm bore |
| 51 | 20 mm bore |
| 52 | 15 mm bore |
| 53 | Supply, fixing, laying & jointing galvanised iron water tubes \"medium grade\" with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, check nuts, caps, plugs etc.and clips, wall hooks etc. laid in trenches, on ground or fixing on wall and testing complete all as specified and directed ofthe following sizes: - |
| 54 | 100 mm bore |
| 55 | 80 mm bore |
| 56 | 50 mm bore |
| 57 | 40 mm bore |
| 58 | 25 mm bore |
| 59 | 20 mm bore |
| 60 | 15 mm bore |
| 61 | M&L for CI fitting (in replacement) cast iron bends (any type, radius and angle), tapers any type, (straight, bend, increasing, decreasing or double sockets etc.) tee pieces single branch, \"Y\" junction, double branch, cross (all socket or spigot and socket) collers, caps and plug upto 150 mm bore for spigot and socket end pipes complete all as specified and directed. |
| 62 | M&L for CI fitting (in replacement) cast iron bends (any type, radius and angle), tapers any type, (straight, bend, increasing, decreasing or double sockets etc.) tee pieces single branch, \"Y\" junction, double branch, cross (all socket or spigot and socket) collers, caps and plug etc from size 200 mm bore to 300 mm bore for spigot and socket end pipes complete all as specified and directed. |
| 63 | S&F in replacement Gun mtal Gate Valve with iron wheel head, screwed both ends for iron pipe with necessary GI fittings and testing complete all as specified and directed of the following sizes:- |
| 64 | 50 mm bore |
| 65 | 40 mm bore |
| 66 | 25 mm bore |
| 67 | 20 mm bore |
| 68 | 15 mm bore |
| 69 | Taking up cast iron water main from trenches carefully without any damage (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed for the following sizes:- |
| 70 | 80 mm bore |
| 71 | 100 mm bore |
| 72 | 150 mm bore |
| 73 | 200 mm bore |
| 74 | 300 mm bore |
| 75 | Supply, laying and testing of centrifugally cast (Spun) ductile iron pressure pipe Class K-7with spigot and socket end pipes suitable for tyton joints duly applied with zinc coating with finishing layer of bitumen on external surfaces and cement mortar lining with bituminous seal coat on internal surfaces complete confirming to IS-8329 (2000) including EPDM gaskets, complete all as specified and directed by the Engineer-in Charge of following sizes :- |
| 76 | 100 mm bore |
| 77 | 150 mm bore |
| 78 | 200 mm bore |
| 79 | 250 mm bore |
| 80 | 300 mm bore |
| 81 | M&L for DI fittings (in replacement) bends (any type, radius and angle), tapers any type, (straight, bend, increasing, decreasing or double sockets etc.) tee pieces single branch, \"Y\" junction, double branch, cross (all socket or spigot and socket) collars, caps and plug up 80 to 300 mm bore for spigot and socket end pipes complete all as specified and directed. |
| 82 | M&L for servicing of sluice valves cast iron body/ Butterfly Valves by greasing/ oilingusing T&P as required as per manufacture instructions& providing glands rope of superior quality and rubber gaskets/packing where necessary to stop any leakage of sluice valve of size 80 mm dia to 200 mm dia complete all as specified and directed. |
| 83 | All as per item No 30.00 above but for bore size 250 mm to 400 mm dia |
| 84 | M&L for (in replacement) brass check nut as per existing size including opening head portion of the valve and refixing the same complete suitable for CI Sluice Valve of following sizes :- |
| 85 | 80 mm to 200 mm dia |
| 86 | 250 mm to 400 mm dia |
| 87 | Cutting existing CI pipes, laid in position for taking out branch connection by inserting new Tee, branches, collar etc. complete all as specified and directed for the following sizes:- |
| 88 | 80 mm bore |
| 89 | 100 mm bore |
| 90 | 150 mm bore |
| 91 | 200 mm bore |
| 92 | 250 mm bore |
| 93 | 300 mm bore |
| 94 | Burning out lead joint and taking out spun yarn carefully complete all as specified and directed for the following sizes of pipes :- |
| 95 | 80 mm bore |
| 96 | 100 mm bore |
| 97 | 150 mm bore |
| 98 | 200 mm bore |
| 99 | 250 mm bore |
| 100 | 300 mm bore |
| 101 | M&L for run lead Joint for cast iron pipes spigot and socket ends and cast iron special fitting with caulked spun yarn and leadcomplete all as specified and directed for following size:- |
| 102 | 80 mm bore |
| 103 | 100 mm bore |
| 104 | 150 mm bore |
| 105 | 200 mm bore |
| 106 | 250 mm bore |
| 107 | 300 mm bore |
| 108 | M&Lfor Rubber gasket Joint (Tyton Joints) suitable for DI pipe ofsize upto 300 mm dia bore complete all as specified and directedNOTE : The quoted rate for jointing of spigot and socket pipes and fittings shall be deemed to include the provision of EPDM gaskets of appropriate size |