Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-07-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-07-2025 |
| 2 | 05-07-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 12-07-2025 |
| Sl. No. | Item Description |
| 1 | Taking down existing non functional security/street light fittings from pole/wall/pipe of any type of LED fitting of any wattage for repairing by replacing of the street light including replacement/ unserviceable accessories like SPD,LED Driver etc & refixingthe same with & including connecting cable of 3core PVC sheathed Aluminium conductor not less than 4 Sqmm from light fitting to cable loping box & tightening of brackets, clamp by nut, bolts and washerincludingtesting complete all as specified and directed. NOTE : (i) Replacement and fixing of unserviceable component etc required will be measured & paid separately under respective items of this schedule.(ii) Fitting shall be connected with existing electric wire / cable, in case of existing wire / cable found unserviceable same shall be measured and paid in relevent items.(iii) Any type of Ladder or arrangement for dismantling of light from pole/hanger pole shall be arranged by the contractor. |
| 2 | Taking down old unsv street light fitting, Supply and fix in replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure diecastaluminumhosingandheatresistant complete with driver, lamp bracket with impactandcorrosionresistantincludingthermalmanagementinmultipleopticscompletewithIP 65/66 protection complete including making connection complete all as specified and as directed by Engr-In-Charge. |
| 3 | Taking down old unsv street light fitting, Supply and fix in replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecastaluminumhosingandheatresistantcomplete with driver, lamp bracket with impactandcorrosionresistantincludingthermalmanagementinmultipleopticscompletewithIP 65/66 protection complete including making connection complete all as specified and as directed by Engr-In-Charge. |
| 4 | Taking down old unsv street light fitting, Supply and fix in replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure diecastaluminumhosingandheatresistant complete with driver, lamp bracket with impactandcorrosionresistantincludingthermal managementinmultipleopticscompletewithIP 65/66 protection complete including making connection complete all as specified and as directed by Engr-In-Charge. |
| 5 | Taking down old unsv Flood light fitting, Supply and fix in replacement of LED Flood light fitting 100 watts to be fixed to channel and as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by Engr-In-Charge. |
| 6 | Taking down old unsv garden light, fitting, Supply and fix in replacement ofExtruded aluminium decorative luminaire for LEDis an ideal solution for Garden/pathways light of housing material powder coated Zn plated ERW MS tubular section , coloure temp cool white 6500K LED 15 watt completeincluding making connectioncomplete all as specified anddirected by Engr-in-Charge. |
| 7 | Dismantling and taking down the existing old rusted and weak mounting brackets of any size & type complete all as specified and directed. |
| 8 | Supply and fixing mounting bracket made out of medium grade GI tubing suitable size bent to street light shape including 02 Nos MS clamps, Nut bolts, washers etc all as directed by Engineer in charge. |
| 9 | S & F in replacement15 W LED solar street Light suitable for Solar pole Light complete all as specified and as directed by the Engineer-In-Charge. |
| 10 | S & F in repacementpost top lantern type light fitting (RUBY (CLEAR) - IP65 ) New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source.including making connection complete all as specified anddirected by Engr-in-Charge. |
| 11 | S & Fix in replacement of Decorative gate light made up of high grade unbreakable Doom Only 6\" to 15\") polycarbonate material suitable for retrofit including LED Lamp9W/10WLamp B22 base.complete all as specified |
| 12 | S & Fix in replacement of Decorative décor square shade 18 watts black Metal Exterior gate light,garden Lamp, outdoor light durable long life water & Rust proof Metalholder type B22 (normal 2 pin type) size 18Lx18Wx28H .complete all as specified |
| 13 | S & Fix in replacement of Varnet waterproof adjustable 5 to 10 watt outdoor garden LED Light aluminium die caste, rustproof lights for garden (colour as required) complete all asspecified and directed. |
| 14 | Taking down/erecting in replacementsteel tubular poles in vertical position/as strut poles sewaged 410-SP-31, 9 Mtr long,complete all as specified and as directed at site by the Engr-in-Charge. |
| 15 | Supply and fix in replacement Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0metres long) complete all as specified and as directed |
| 16 | Taking down of old U/S cable of any size any capacity of broken/damage all specified & directed by Engr-in-charge. |
| 17 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4.0 Core complete all as specified and directed. |
| 18 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4.0 Core complete all as specified and directed. |
| 19 | Boring under Road / PCC by using manual tool for insertingPVC/GI pipe of 40mm size for protection of cable complete all as specified and as directed by the Engineer-In-Charge. |
| 20 | Trimming of trees all as along the LT line in such a way that there is clear distance of 3 meter between tree and electric line.The work will be executed to the entire satisfaction of Engr-In-Charge irrespective of the size of the tree branches etc complete all as specified and as directed.Note : (i) Tree branches etc will be left as itias the wood belongs to Cantt board/DEO back as if the property of (ii) Contractor will employ sufficient labour to complete the full one job with in time consitant by directed by engr-in-charge.(iii) Contractor will only be responsible for any type of accident if take place while trimming the trees. (iv) Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply, however full asministrativeassistance will be provided by MES staff. |
| 21 | S & Fixing of lead acid power pack,180 AH, industrial heavy duty, 25/ 27 plates for DG set startingonly after disconnecting connection and taking down the unserviceable one complete all as specified and directed. |
| 22 | M&L Preparation of old (exposed) painted surface ofexisting (410 SP-31 ) Steel tubler poles /strut including cross clamps etc complete and applying two coat of aluminium paint above band/straps and painting of band/strap with paint of colour red post office and black numbering of pole at a height 1.5 m above GL as per existing having 15mm wide of poles at a heigth 1.5 M above GL as per existing having 15 mm wide and 50 mm bolt letter compete all as specified and directed . |
| 23 | M&L for replacement of cross arms. bracing supports. clamps back plates. fabricated from strucural steel sections including nut bolts washers . welding. bending cold or hot drilling holes for bolts in any shape orsize as indicated ordirectad and incclusive of twocoat of aluminium paint over one coat of redoxide . including taking down of unsv items all as specified and directed . |
| 24 | M&L PCC 1:4:8 type D2using 40mm stone aggregate for pole foundation complete all as directed |
| 25 | M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping around poles, including necessary form work finishing even and smooth complite all as specified and directed . |
| 26 | Excavationintrenchesnotexceeding1.5 M wideandnotexceeding1.5 Mindepthandgettingoutin soft/looseor any other type ofsoilfortakingup orlaying ofcableallasspecifiedanddirected. |
| 27 | Returning, filling inincludingspreading, levelling, wateringandwellramminginlayersnotexceeding25 cms complete all as specified and directed. |
| 28 | Removing excavatedmaterialnotexceeding50 Manddepositingwheredirectedatalevelnotexceeding 1.5 Mabovestartingpoint complete all as specified and directed. |
| 29 | Supply and laying new dry riversand laidintrenches 8cm below the cable and 15cm above the cable and punned to 18cmascablecushioningandcoveringall asdirected. |
| 30 | M&L for laying bricks, sub class\"B\" for protection of cable, in trenches, laid in dry flat across the cable with length of whole bricks complete all as specified and directed. |
| 31 | Supply and Fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed 10 sqmm 2 core in service connections , one twin core cable circular complete all as specified and as directed by Engr-In-Chage. |
| 32 | Supply and Fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed 6.0 sqmm 2 core in service connections suspended by insulatingone twin core cable circular complete all as specified and as directed by Engr-In-Chage. |
| 33 | Supply and Fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed 2.5 sqmm 2 core in service connectionscomplete all as specified and as directed by Engr-In-Chage. |
| 34 | Earthing complete with galvanised steel earth plate electrode60×60cm.× 6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate notless\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on complete all as specified and directed |
| 35 | Supply & filling distilled water in batteries as required at various DG set installations all as specified and directed. |
| 36 | Maintenance/ servicing of different capacity of DG sets by carrying outcheck as per manfacturers maintenance chart : (Note:Engine Oil and patrs shall be measured and paid seperately under respective item.) |
| 37 | (a)DG set30 KVA , Engine complete all as specified and as directed |
| 38 | (b)DG set40 KVA, Engine complete all as specified and as directed. |
| 39 | (c)DG set50 KVA, Engine complete all as specified and as directed. |
| 40 | (d)DG set63 KVA, Engine complete all as specified and as directed |
| 41 | M&L for PT pump & injector of 30 to 63 KVA DG Set by taking out carefully and refixing after caliberation at manufacturer dealer including replacement of u/s worn out parts complete all as specified and as directed. |
| 42 | M&L for taking out radiator assy from existing DG of cap 63 KVA and repair to radiator tank, cleaning complete radiator with anti corrosion chemical, rewelding/ soldering for tubes / tank and refixing complete including replacement of hose pipe set with clamp connected to upper and lower tank for making complete water leak of radiator complete all as specified and directed by Engineer in Charge. |
| 43 | Repair to oil cooler of capacity63 KVA DG Set Cummins/Kirloskar diesel engine water cooled with following parts:-(i) Element tube oil cooler- 02 Nos(ii) O\" ring-02 Nos(iiI) Retainer O\" ring-02 Nos(iv) Gasket-01 Set(v) Hose pipe -01 set(vi) Clamp hose-02 Nos |
| 44 | M&L for taking out FIP from DG Set of capacity 63 KVA and replace the unsv partsall specified and directed by Engr-in-charge. |
| 45 | M&L for reparing and rewinding of alternator of suitable parts of cap of DG Set 30 to 63 KVA all specified and directed by Engr-in-charge. |
| 46 | Supply and replacement of water circulating pump/water body suitable for 30 KVA to40 KVA capacity DG Sets complete all as specified and as directed. |
| 47 | Supply and replacement of water circulating pump/water body suitable for 50 KVA to63 KVA capacity DG Sets complete all as specified and as directed. |
| 48 | S&F diesel fuel inlet/ oulet, breaded flexible pipe of 20 mm dia. With clamps clips for DG Set any capacity all as specified and directed. |
| 49 | Dismentling the non functional turbo charger for63 KVA DG set 1500 rpm, any Make from engine and replacing with new turbo assy complete, assembling , testing and commissioning at site complete all as specified and directed. |
| 50 | Dismentling the non functional turbo charger for 40 KVA DG set 1500 rpm, any Make from engine and replacing with new turbo assy complete, assembling , testing and commissioning at site complete all as specified and directed. |
| 51 | S & Replacement of Auto Voltage Regulator complete with wire connection and connected to existing field coil, 24 Volt, DC for cap of DG set 30/40 KVA Make- Kirloskar / Cummins after taking out the unserviceable one complete all as specified and as directed. |
| 52 | S & Replacement of Auto Voltage Regulator complete with wire connection and connected to existing field coil, 24 Volt, DC for cap of DG set 63 KVA Make- Kirloskar after taking out the unserviceable one complete all as specified and as directed. |
| 53 | S & Replacement of alternator 24 Volt (for charging of battery) for 30 to 63 KVA DG Set Make Lucas after taking out the unserviceable one complete all as specified and as directed. |
| 54 | Taking down the u/s self starter and repairs with rewinding to self starter of capacity 12/ 24 Volt by taking out old burnt out copper winding wire with super enamelled copper wire same gauge including replacement of u/s pinion, bush, solenoid coil, carbon brushes & tension spring complete and the DG Sets and testing consider all as specified and directed. |
| 55 | M&L for replacement of air filter of DG set of Cummins/ kirloskar of Capacity 30 KVA complete all as specified and as directed |
| 56 | M&L for replacement of air filter of DG set of Cummins/ kirloskar of Capacity 40 KVA complete all as specified and as directed |
| 57 | M&L for replacement of air filter of DG set of Cummins/ kirloskar of Capacity 50 KVA complete all as specified and as directed |
| 58 | M&L for replacement of air filter of DG set of Cummins/ kirloskar of Capacity 63 KVA complete all as specified and as directed |
| 59 | M&L for replacementfillingthe Engine Oil DG set complete as specified and directed by Engineer in charge. |
| 60 | M&L for replacement of fuel filter of DG set of Cummins/ kirloskar of Capacity 30KVA complete all as specified and as directed |
| 61 | M&L for replacement of fuel filter of DG set of Cummins/ kirloskar of Capacity 40 KVA complete all as specified and as directed |
| 62 | M&L for replacement of fuel filter of DG set of Cummins/ kirloskar of Capacity 63 KVA complete all as specified and as directed |
| 63 | M&L for replacement of Lube oil filter of DG set of Cummins/ kirloskar of Capacity 30 KVA complete all as specified and as directed |
| 64 | M&L for replacement of Lube oil filter of DG set of Cummins/ kirloskar of Capacity 40 KVA complete all as specified and as directed |
| 65 | M&L for replacement of Lube oil filter of DG set of Cummins/ kirloskar of Capacity 50 KVA complete all as specified and as directed |
| 66 | S & F in replacementchangerover Switch 200 Ampto be fixed to channel and as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by Engr-In-Charge. |
| 67 | Supply and replacement of solenoid coil, 12/ 24 Volts , DC operated with lead and fixing clamps all as directed by Engr in Charge. |
| 68 | M&L for replacement of hose pipe set (water/ oil) complete with clamp and other fitting as required at site for 63 KVA DG Set of make Kirloskar/ cummins all as specified and directed. |
| 69 | M&L for replacement of hose pipe set (water/ oil) complete with clamp and other fitting as required at site for 40 KVA DG Set of make Kirloskar/ cummins all as specified and directed. |
| 70 | M&L for replacement of hose pipe set (water/ oil) complete with clamp and other fitting as required at site for 12.5 to 30 KVA DG Set of make Kirloskar/ cummins/ Atul Shakti all as specified and directed. |
| 71 | Supply and filling coolant for DG set as per DG set manufacturers recommendations all as specified. |
| 72 | M&L for renewal of battery terminal heavy duty made out of brass suitable for 12 V lead acid battery complete all as specified and as directed. |
| 73 | S&F in replacement taking out the old unserviceable sealed compressor unit from existing Split/window type AC 1.5 ton capacity of any make by cutting and replacing the same with new sealed unit from authorised OEM workshop/manufacturer and reconnecting the replaced sealed compressor unit to its original position ofair conditioner by brazing incl flushing out complete refrigerator system by applying CTC/nitrogen gas, charging the refrigeration systemwith and incl compressor oil and refrigerant R-134 gas to its full capacity after complete equating and cleaning the system reinstalling the air conditioner at site and testing on false load to its satisfactor performance complete all as specified and directed. |
| 74 | All as per item No 1 here-in-before but for capacity of air condition (2.00 ton)complete all as specified and directed. |
| 75 | Material and labour for detecting of leakages of gases in window type /Split Type AC unit of capacity 1.5/2 TR at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition complete all as specified and as directed. Note:- Refrigerant for toping up/ filling in will be measured and paid seperately under relevant items in the Schedule. |
| 76 | Taking downfor servicingof split type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. |
| 77 | Taking downfor servicingofWindow type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa andkeepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing positioncomplete all specified and as directed by Engineer-in-Charge.Notes for Ser Item No 4 & 5 :- (i) Replacement of defectivespares for making the AC units in satisfactory working conditionwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & refixing of new sparesshall deemed to be included in unit quoted rate. |
| 78 | Supply & fixing heavy duty copper pipe 6mm/12mm/15mm dia/ bore complete including insulation brazing, welding, nuts,bolts and screws of required size complete all as specified and directed by Engr-in-Charge. |
| 79 | Supply & fixing in repairs of suctionand discharge valve set of size 15mm (5/8\"\"), 6mm (1/4\"\") and 12mm (1/2\"\")for Split AC 1.5/2 TR capacity complete all as directed by Engr-in-Charge. |
| 80 | Taking down unserviceable insulation for copper pipe of any dia, supply and fixing new insulation for copper pipes suitabale for Split AC of capacity from 1.5 to 2.0 TR complete all as specified and directed by Engineer-in-charge. |
| 81 | Disconnection and removing of serviceable window type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer from its position and fixing the same in other location including all other fixing accessories and testing complete allas specified and directed by Engineer-in-charge. |
| 82 | Disconnection and removing of serviceable split type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer (Indoor & Outdoor Unit) from its position and fixing the same in other location including all other fixing accessories and testing complete allas specified and directed by Engineer-in-charge. |
| 83 | S&F in repairs for over load protector suitable for AC protector complete all as specified and directed. |
| 84 | S&F in repairs for condensor unit copper type suitable for split/window AC 1.5/2 ton capacitycomplete all as specified and directed. |
| 85 | S&F in repairs relay suitable for 1.5 Ton (window/Split type) air conditioner complete all as specified and directed. |
| 86 | S&F in repairs thermostat switch for AC complete all asspecified and directed. |
| 87 | S&F in repairs switch controlling knobs along with complete control panel for any make and any size of AC complete all asspecified and directed. |
| 88 | S&F in repairs running capacitor of required 36/45 MFDcomplete all asspecified and directed. |
| 89 | S&F in repairs starting capacitor of required 120 MFD complete all asspecified and directed. |
| 90 | M&L for repairing of voltage stablizer of any make and size of 3 KVA to 5 KVA by repairing/replacement of electric circuit and rewinding includinginsulatingmaterials complete all asspecified and directed. |
| 91 | S&F in repairs of PCB sutable size for window / split inverter type AC complete all asspecified and directed by Engr In Charge. |
| 92 | Taking of old unserviceable/sealed compressor unit from existing refrigerator of 200 to 300 ltrs capacity of any make by cutting replacing the same from authorized OEM workshop and re-connecting the sealed compressor unit to its original position of refrigerator by brazing incl flushing out complete refrigeration system by applying/using Nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134A gas to its full capacity reinstalling the refrigeration machine at site testing on full for its satisfactorily performance incl painting to complete body of refrigerator with two coats ofsynthetic enamel paint after preparation of dents complete all as specified and directed. |
| 93 | All as per item No 13 here-in-before but for capacity of refrigerator 165/175 ltrscomplete all as specified and directed. |
| 94 | Taking down for servicing of Refrigerator 200 to 300 ltrs capacitycomplete refrigeration systemby nitrozen/CTC gas after deleting leakage and repairing tube/linesby brazing and charging the unit withcompressor oil and refrigerant Gas-134 to its full capacityof refrigerator 300 lts/310 ltrs capacity of any make incl commissioning and testing for its smooth functioningcomplete all as specified and directed. |
| 95 | S&F rubber gasket of refrigerator door of any size and any makecomplete all as specified and directed. |
| 96 | Supply and replacement of thermostat switch of suitable size for any make and size of refrigeratorcomplete all as specified and directed. |
| 97 | S&F in repairs for starting to running capacitor 40 MFD capacity complete all as specified and directed. |
| 98 | S&F in repair for over load protector suitable for refrigerator protector complete allas specified and directed. |
| 99 | M &L for repair of freezer door of any make 310/300/165 ltrs size of refrigeratorscomplete all as specified and directed. |
| 100 | Repair to body of refrigerator of any size/capacity by welding of MS Sheet not less than 1.6 mm thich to match existing after receiving old rusted/unserviceable portion replacement of old nut bolt washers and hinges of top cover incl painting to complete body of refrigerator with two coat of synthetic enameled paint after preparation of surface and removing dents complete all as specified and directed. |
| 101 | Taking of old unserviceable/sealed compressor unit from existing deep freezer of 300/320/400 ltrs capacity of any make by cutting replacing the same from authorized OEM workshop and re-connecting the sealed compressor unit to its original position of refrigerator by brazing incl flushing out complete refrigeration system by applying/using Nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity reinstalling the refrigeration machine at site testing on full for its satisfactorily performance incl painting to complete body of refrigerator with two coats ofsynthetic enamel paint after preparation of dents complete all as specified and directed. |
| 102 | Taking out the broken legs & replacement from the base of refrigerator supplying and fixing new legs set of 4 to put the refrigerator of any capacity/make in to vertical position complete all as specified and directed. |
| 103 | S&F in repairs for condensor unit suitable for deep freezer of existing size anycapacitycomplete all as specified and directed. |
| 104 | M&L for repairing of voltage stablizer of any make and size of 2 KVA to 3 KVA by repairing/replacement of electric circuit and rewinding includinginsulatingmaterials complete all asspecified and directed. |
| 105 | Taking out the old unserviceble sealed compressor from existing water cooler of any capacity of any make 120/60 and 150 ltrs storage capacity by cutting, replacingthe same with new compressor from nanufacturer and re-connecting the replaced sealed comressor, unit to its original position of water cooler by brazingincl flushing out complete refrigeration system by applying/using CTCNitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity aftercomplete evacuating and cleaning the system reinstalling the water cooler at site andtesting on full for its satisfactorily performancecomplete all as specified and directed. |
| 106 | All as per item No 30here-in-before but for capacity of water cooler 40/60 ltrs complete all as specified and directed. |
| 107 | Flushing outcomplete refrigeration systembyCTC andrepairing the leaking pipe/joints by refrigeration brazing and charging the unit with compressor oil and refrigerant gas after evacuating and flushing to its full capacity of any size and make of water cooler complete all asspecified and directed. |
| 108 | S&F in repairs for condensor unit suitable for water cooler anycapacitycomplete all as specified and directed. |
| 109 | S&F in repairs for running capacitor of suitable size of water cooler of any make and size complete all as specified and directed. |
| 110 | S&F in repairs for startingcapacitor 80/100/120 mfd capacity complete all as specified and directed. |
| 111 | S&F in repairs for relay assembly 412Y/312Y complete all as specified and directed |
| 112 | S&Fin repairs for over load protector suitable for water cooler protector completeall as specified and directed. |
| 113 | S&F in repairs for thermostat for water cooler complete all as specified and directed. |
| 114 | S&F in repairs rubber bedding gasket for any make and size of water cooler tank cover upto 25mm bore complete all as specified and directed. |
| 115 | Repair to body of water cooler of any size/capacity by welding of MS sheet not less than 1.6mm thick to match existing agter receiving old rusted/unserviceable portion, replacement of old nut bolt washers and hinges of top cover including painting to complete body of W/C with two coat of synthetic enameled paint after preparation of surface and removing dents complete all as specified and directed. |
| 116 | S&F in Replacement of PVC copper cable 2.5 sqmm multistrand three core complete all as specified and directed. |
| 117 | M&L for repairing of voltage stabilizer of any make and size of 0.5 KVA to 1 KVA by repairing/replacement of electric circuit and re-winding including insulating materials complete all as specified and directed. |
| 118 | Taking down old unsv AC indoor and outdoor unit complete S & F in replacement ofinverter type latest star rating with 3 KVA voltage stablizer, Split AC unit 1.5 Ton capacity indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality on single phase AC supply including necessary interconnected refrigerent copper tubing insulated of required dia & length condence water PVC rigid piping not less than 19mm external dia and 2 mm thick, outer unit stand made out of stain less steel andleakage testing duly filed with CFC free gas for fixing of compressor as upto the required pressure as per manufacturer, directions required civil work ie making hole, PCC work, MS stand/bracket duly painted and connection etc complete all as specified. |
| 119 | Supply and Fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all asspecified and directed. |
| 120 | Material and labour for two single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as an earth continuity conductor complete all as specified. |
| 121 | Material and labour for two single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as an earth continuity conductor complete all as specified. |
| 122 | M&L for complete overhauling of desert cooler of any size and make including replacement of perished wiring oiling and greasing the blower motor exhaust fan and water lifting/tullu pump including replacement of plastic unserviceable spares susch as ben, water distributor and PVC pipe including replacement of wood pads, preventing leakage if any by welding, painting of water tank with rubber seal of any approved make and testing the same for its smooth functioning complete all as specified and directed. |
| 123 | M&L for Desert cooler fan/ exhaust fans any type 230 V, AC sup, Single phase dismantling the cooler fan/ exhaust fans and taking out complete burnt winding from cooler fan motor and rewinding the same with super enameled copperwinding wire of existing gauge and size incl throughly cleaning all the components of coolerfan, oiling and greasing painting with one coat of synthetic enamel paint after scrubbing and preparingthe old painted surfaces & testing etc complete all as specified and directed. |
| 124 | M&L for two coats of painting for desert cooler cover a coat of red oxide primer including preparation of old surfaces on complete body of desert cooler of existing colour after removing dents and preparing surface complete all as specified and directed. |
| 125 | supply and fixing in repairs front grill of desert cooler of approved make complete with 5 Amp switch , three speed regulator including lamp complete all as specified and directed. |
| 126 | S & F in repairs 3 pin plug top 5 amp, 230V for desert cooler complete all as specified and directed. |
| 127 | S&F in replacement of water submersible pump 40 watt (2.65 mtr water lifting) water pump for desert cooler (1.5 mtr power cord)type complete all as specified and directed. |
| 128 | S&F in replacement of wood wool for desert cooler of any size complete all as specified and directed. |
| 129 | Supply and fillingrefrigerant gas R-22/R-410A/R-32/R-134A in window type /Split Type AC unit of capacity 1.5/2 TR, Deep Freezer, Refrigerator, Water Cooler of any capacity complete all as specified and as directed. |
| 130 | Supply and Fixing Heating element ofcapacity 1.50 KW any type, ISI marked, suitable for geyser of capacity 25/50 Ltr complete all as specified and directed by Engineer-in-charge. |
| 131 | Supply and fixing capacitor Dry type 2.5 MFD 230 volts for Ceiling fan of any typecompleteall as specified and directed. |
| 132 | Supply and fixing capacitor Dry type 4 MFD 230 volts for Exhaust/cooler fan of any typecompleteall as specified and directed. |
| 133 | Supply and Fixing of fan blade for Desert cooler of any type and any size complete all asspecified and directed. |
| 134 | Supply and Fixing of fan blade for AC of any type and any size complete all asspecified and directed. |
| 135 | Supply and Fixing of fan blade for water cooler of any type and any size complete all asspecified and directed. |
| 136 | Supply and Fixing of fan blade for deep freezer of any type and any size complete all asspecified and directed. |
| 137 | Supply and fix in replacement of desert cooler electric driven body size height 38 inches, front 28 inches, back 24 inches, tank size 28x35x8 inches tank water capacity 80 ltr approx fitted with heavy duty fan & exhaust motor (single phase), having .made out of 0.65mm thick GI sheet including opening door shutter three side with two Nos door handle and tulu pump and other accessories complete all as specified and as directed by Engr-In-Charge |
| 138 | Supply and Fixing solar water heating element with auto cut thermostate ofcapacity 2KW any type, ISI marked, suitable for solar element of capacity 500 Ltr complete all as specified and directed by Engineer-in-charge. |
| 139 | M&L in replacement for Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick burried in a pit to a depth of 2.25mtrs below ground level with top edge of earth plate at a depth of not less than 1.50 meters below ground level, earth plate packed on all sides with charcol dust mixed with salt to a thickness of 15cm,.Connected with earthing lead of 32mmx6mm strip galvanised iron, watering pipe 20mm dia light grade and water filling funnel and mess complete all as shown in plate No 3 of MES schedule part II to the earthing test point, Including PCC Work complete including taking up of old UNSV earthing complete all as specified and directed by Engr-in-Charge. (Note :- Earthing lead beyond test point shall be measured separately) |
| 140 | Supply and laying in replacement of earthing strip GI 32 x 6 mm from earth test point to Electrical equipment including taking up of old UNSV earthing strip complete all as specified and directed by Engr-in-Charge. |
| 141 | Supply & Fixing MCCB, 3 Pole, 100 Amps, 415 Volt, 16 kA including connecting up using suitable size of lugs all as directed. |
| 142 | Supply & Fixing MCCB, 3 Pole, 125 Amps, 415 Volt, 16 kA including connecting up using suitable size of lugs all as directed. |
| 143 | Supply & Fixing MCCB, 4 Pole, 160 Amps, 415 Volt, 25 kA including connecting up using suitable size of lugs all as directed. |
| 144 | Supply & Fixing MCCB, 4 Pole, 200 Amps, 415 Volt, 25 kA including connecting up using suitable size of lugs all as directed. |
| 145 | Supply & Fixing MCCB, 4 Pole, 250 Amps, 415 Volt, 25kA including connecting up using suitable size of lugs all as directed. |
| 146 | Supply & Fixing MCCB, 4 Pole, 400 Amps, 415 Volt, 36 kA including connecting up using suitable size of lugs all as directed. |
| 147 | Supply, installation, testing and commissioning in replacement electrical cubical controlout doorcubical fedder pillarboxfactory assembledwheather and vermin proof fabricated of 3.15 mm CRCA MS sheetSuitable for ,3 phase 4 wire 415 Volt AC 50 Hz complete electric supplyduly painted with powder coating complete with locking arrangement, earthing terminals with suitable incoming/outgoing MCCB\"s,measuring instrument such as digital Volt meter,digitalAmmeter, Selector switchs,with suitable ratio CT\"s - 3 Nos , Phase indicator lamps with holder , toggle switches and backelite fuse cut outs etc including incoming and outgoing cables connections with suitable cable glands andgrouting of feeder pillar box 30 cm aboveand 30 cm below ground level by providing angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete including taking up of old UNSV feeder pilarbox complete all as specified and directed by Engr-in-Charge.( Feeder piller box shall be consisting the following in addition to the item mentioned here -in- before) |
| 148 | a)Cupper bus barproper insulated 03 Nos for phase (RYB) rating 400 Amp and 01 Nos neutral rating 400 Amp and mounting on porcelain support (b) MCCB 4 Pole 400 Amp repturing capacityrating 35 KA -01 Nos (Incomming)(c) MCCB 4 Pole 100Amp repturing capacityrating 25 KA - 03 Nos (Outgoing)Note : Cost for all itemsto be assembled in the panel are deemed to be included in item rate quoated |
| 149 | M&L for painting to overhead tanks in,out & over flow pipe line scrubing and two coat colour coding enimeled paintig of over head pipe line and marking of flow as all specified & directed by Enge-in-charge. |
| 150 | Supply and fixingin replacement of Pump House/Sump new energy saving LEDlight fitting 35 watt made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK07as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by E-In-C. |
| 151 | M & L for GI Bracket made out of 25 mm GI Pipe light grade 1.20 m length bend to shape including clamps, nuts bolt and washer and fixing to wall/ floor complete as directed by Engr - in - Charge. |
| 152 | M&L for painting of 3x2mtr surface of front side of power house/pump house one coat black paint & marking of namewhite paint ,MES Installation name of the power house ,pump hose /sump complete all specified & directed by Engr-in-charge. |
| 153 | M&L for painting of pannel and Motor/colume pipe line of the pump house two coat synthetic enamel paint incl prepration of surface complete all specified & directed by Engr-in-charge. |
| 154 | S&F in replacement of powder fire extinguisher ISI marked to capacity 5 kg complete with grip relese valve ,discharge pipe ,locking arragement pressure guage etc all as per reqd complete all specified & directed by Engr-in-charge. |
| 155 | S& F in replacement of fire hook with bamboo 3 mtr long ISI marke lcomplete all specified & directed by Engr-in-charge. |
| 156 | S& F in replacement of fire bitter with bamboo 3 mtr long ISI marke lcomplete all specified & directed by Engr-in-charge. |
| 157 | S& F in replacement of fire bucket iron 10 ltr capacity with both side handle for(sand & Water) ISI marke lcomplete all specified & directed by Engr-in-charge. |
| 158 | S&F in replacement of synthatic rubbe insulated mats 2.5 mm thick for electrical purpose as per ISI markedsuitable for electrical shock of size 2x1 mtr complete all specified & directed by Engr-in-charge. |
| 159 | S&F in replacement of single pointed air termination aluminum rod 12mm dia 300 mm long complete all specified & directed by Engr-in-charge. |
| 160 | S&F in replacement of GI pipe medium grade 40mm dia galvanised added on pcc block for fixing air termination rod 12mm complete all specified & directed by Engr-in-charge. |
| 161 | M&L for power house/pump house dangerous notice plate of size 200x200x2mm thick MS plate writing & painting & fixing front side of gate complete all specified & directed by Engr-in-charge. |
| 162 | Trimming of trees all as along the LT line in such a way that there is clear distance of 3 meter between tree and electric line.The work will be executed to the entire satisfaction of Engr-In-Charge irrespective of the size of the tree branches etc complete all as specified and as directed.Note : (i) Tree branches etc will be left as itias the wood belongs to Cantt board/DEO and they will be responsible for the wood.(ii) Contractor will employ sufficient labour to complete the full one job with in about 15 days. (iii) Contractor will responsible for any type of accident while trimming the trees. (iv) Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply, however full assistance will be provided by MES staff. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail