Electrical Relay Testing , Electrical Relays Testing And Calibration For Mills , Over Current & Earth Fault Relay Make : C&Stype : Iri-Pro-3I-Vei , Under Voltage -Over Voltage Relay Make : C&Stype : Iru-Pro-Uo/R , High Speed Tripping Relay Make :Cspc , Trip Circuit Supervision Relay Make : C&Stype : Mra-Pro-V2 , Convertor Tranformer -1 , Inter Trip Relay Make: Cspc , Auxiliary Relay Buchholz Relay , Winding Temperature, Oil Temperaturer (Trip Function) Make: Cspc , Fibrizer , Mrm Relay , Load Manager ,Conerve , Schneidr Model: Em6400 , Temperaturescanner Make: Nippon Technologies Model|: Vnsc08, 8 Chennal Input: Pt100 , S.No: 11190095 , Lt Transformer -1 & 2 , Over Current & Earth Faultrelay Make: Abb ,Type: Ni 41 , K51-1 ,Model-Irf , Master Trip Relay Make: Abb Pq8nch2js , Trip Circuit Supervision Relay Make: Abb Type:Tcs,Model: Imyn569697-E , 15Mw Cogen Relay , 27 Dc Supply Supervision Relay Make- Areva, Auxiliary Relay- Vaa, Vaa 11Ye8030ahch Vx1 110V Sl. No. -31811880/06/11,Vx2 - V, Rext. O , 60M - Metering Pt Fuse Fail Relay Mvapm Make- Areva,Mvapm 32D1aa2001a, Sl.No. 31750101/05/1P, Vx(1) 110-125 Dc, Vn 110Ac, Vx(2) 220-250Dc, 50Hz. , P441 Micomdist. Protn. Make - Areva, 2, 195, 295, 60, 95/86 Micom P441 (Schneider Electricals) , P127 Micomo/C, E/F Protn. Make - Areva, 50/51, 67/67N, 60Micom P127 (Schneider Electricals) , 96 - Bus Bar Trip Relay Make- Areva, Tripping Relay- Vaj, Vajhm23zg0752bba Vx 110-125V Sl. No. -31760210/05/11,Rext. O , Master Trip Relay Make - Areva, Tripping Relay-Vaj, Vajhm23zg0752bba, Vx 110-125V, Sl.No. 31803570/06/11, Rext.O , P923 Micom Freq Protn. Make - Areva, 81 Dv/Dt, Df/Dt,27, 59, Micom P923 , 86X - Trafo Protn Inter Trip Relay Make - Areva, Auxiliary Relay - Vaa,Vaa11ye8402ech, Vx1 110-125V, Sl.No. 31710118/03/11, Vx2 220-250V, Rext. O . , P632 Micom Main Protn. 87T, 64R, 50N, 95/86 Micom P632 , P341 Backup Protn. 50/51, 67/67N, 78.60 , Ar1 -Aux Relay - Vaa ( For Trafo. Faults) Make- Areva, Auxiliary Relay- Vaa, Vaa 33Zg8323bch Vx1 110-125V,Vx2 - V, Rext. O , Switch Yard Relays , P122, Main Zone B/B, Prot Make - Areva, Ct, Sup 87, 95 Micom P122 , 95Mx - Main Zone Ct Bus Wire Shorting Make - Areva, Tripping Relay- Vaj, Vajh13f0750bba, Vx 110-125V, Sl.No. 31771208/05/11 Rext. O , 95Cx - Chk Zone Ct Bus Wire Shorting Make - Areva, Tripping Relay - Vaj, Vajh13yf0750bba Vx110-125V, Sl.No. 31771211/05/11 Rext. O , Dcs Room Relaypanel , Voltage Balance Relay Exct Pt60c Make- Areva, Type- Mvapm,Model-Mvmpm 32D1aa200a Sl. No. 31647848,Vx1-110/125V Dc Vn110ac,Vx2-220/250V Dc 50Hz , Micom P343 Make- Areva,Model No-P343211e2m0350j,Sl.No-31578308.Test Id-578308T.Generator Protection Realy , Voltage Balance Relay Metg Pt60b Make- Areva,Type- Mvapm,Model-Mvmpm 32D1aa200a Sl. No. 31647861,Vx1-110/125V Dc Vn110ac,Vx2-220/250V Dc 50Hz , High Speed Trip Relay Gen 86G/T/L Make- Areva,Type- Vaj,Model-Vajhm23zg121b Sl. No. 31620118,Reset & Operating Volts 100-125V Dc , Supply Supervision Relay 80Dc Make- Areva,Type- Vaa, Model-Vaa 21Yf8013ahch ,S. No.31636365,Lh Volts 110Dc,Rh Volts 230-240V,50Hz. , Trip Circuit Supervision Relay Gen 95G Make- Areva,Type- Vax Mk.11, Model-Vax21zg8044bch ,S. No.31595537,Vx(A)110-125Vdc Vx(B) Nill Vx(C)110-125Vdc. , Trip Relay Supervision Grid 95L Make- Areva, Trip Circuit Supervision Relay,Type- Vax Mk.11, Model-Vax21zg8044bch ,S.No.31595542, Vx(A)110-125Vdcvx(B) Nill Vx(C)110-125Vdc. , Timer Rotor E/F Production 2/64F1 Make- Areva,Definite Time Relay,,Type- Vtt, Model-Vtt11zg8194bch ,S.No.31627450,Reset &Operating Volts 100-125V Dc,Timing Range 1-10Sec , Rotor 1 St E/F Production Make- Areva,Rotor Earth Fault Relay,,Type- Vaem Mk.11, Model-Vaem21af101d,S.No-31637416,Aux Volts230/240V Ac 50Hz,Rotor Volts0-550V Dc. , Reverse Reactive Power Production 32Q Make - Areva, Define Time Reverse Power Relay,Type-Ccum,Model No-Ccum21pf172a,Serial No-31507197,110V 1A 50Hz,Max Torque Phase Angle 30 Deg,Aux.Volts110-125Vdc,Timing Range 1-10Sec , Rotor 2 Nd E/F Production64f2 Make - Areva,Second Rotor Earh Faultrelay,Type-Caem,Model No-Caem33af101d,Serial No-31535464,Aux Volts 230-240Vac 50Hz,Rotor Volts 0-440V Dc. , Guard Relay Make- Areva,Type- Vaa,Model-Vaa21zg8502fch Sl. No. 31496040,Reset &Operating Volts 110-125/220-250V Dc. , Incoming Bus No Volt Relay Make- Areva,Type- Vag,Model-Vag11yf8011adch Sl. No. 31568353,Drop Off Volt:27.5/66Ac50hz,Normal Volts:110Ac 50Hz. , Check Synchronising Relay Make- Areva, ,Type- Ske, Model No-Ske11bf8012bch Sl. No.31574576,Rat Volts V1,V2:63.5/110V 50Hz Angle 20D Aux Volts 110-125V Dc,%Slip/T(Sec)-0.45/0.50,0.22/1.0,0.11/2.0,0.09/2.5,0.07/3.0. , Auxiliary Relay(Avr Priming) Type Vaa ,Make: Areva,Model No: Vaa11yf8402fch , Ht Switchgear Relays , Trip Circuit Supervision Relay - Mra -Pro-V2 ,Make C &S , Trip Circuit Supervision Relay - Tr1 Cspc Make,110 V Dc,Mra -Pro-V2 , O/C And E/F Relay -Tr1 Irc-Pro-3I-Ei,Make C&S , Trip Circuit Supervision Relay - Tr2 Cspc Make,110 V Dc , Neutral Displacemnt Relay Make C&S ,Iru-Pro-Uo/R-Export Feeder , High Speed Trip Relay- Clr-H3 110V Dc,Make Cspc,Export Feeder , Ht Switchgear Relays , Master Trip Relay Abb Make Pbnch2jsfor Tr1/Tr2 , O/C And E/F Relay Abb Make - Ni41 For Tr1 , Sf6 Breaker /Relay , Auxiliary Relay(Avr Priming) Type Vaa ,Make: Areva,Model No: Vaa11yf8402fch