| 1 | Taking downstorage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main point and carryout in MES store yard for repairing of capacity 25/50 ltrs of any type and make complete all as specified & directed by Engineer-in-charge. |
| 2 | Refixing storage type water heater storage type capacity 25/50 ltrs of any type, any make and the serviceablity of all parts of such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly complete (considered as one unit) and installing and testing the same as per the direction of Engineer-In-Charge.(Note :- Supply only for parts against unserviceable parts shall be measured and paid for separately under relavent items given below) |
| 3 | Supply & Fix for heating elements, 1.5 KW ISI marked 230 volts and including taking out existing heating elements complete all as specified and directed by Engineer-in-charge. |
| 4 | Supply & Fix for heating elements, 2 KW ISI marked 230 volts and including taking out existing heating elements complete all as specified and directed by Engineer-in-charge. |
| 5 | Supply & Fix for thermostat immersion point, Length 175 mm to 250 mm, Temperature 0 to 75 degree C, 230 volts/AC and including taking down existing thermostat immersion point complete all as specified and directed by Engineer-in-charge. |
| 6 | Supply & Fix of safety valve for 25/50 ltr geyser and including taking down existing safety valve complete all as specified and directed by Engineer-in-charge. |
| 7 | Supply & Fix of pressure releasing valve for 25/50 ltr geyser and including taking down existing pressure release valve complete all as specified and directed by Engineer-in-charge. |
| 8 | S & F sheet metal enclosure with two pin and earth metal clad plug and socket complete with one double pole MCB 20 Amp 240 V and including taking down existing metal clad plug complete all as specified and directed by Engineer-in-charge. |
| 9 | Supply & Fix for Three pin plug top, 16 amp capacity, 240 VAC, heavy duty and including taking down existing plug complete all as specified and directed by Engineer-in-charge. |
| 10 | Supply & Fix for MCB SP 16 Amps single pole, \"B\" curve, 230 volt, 50 Hz and including taking down existing MCB complete all as specified and directed by Engineer-in-charge. |
| 11 | Supply & Fix for Fastners screw for fixing Geyser storage capacity 25/50 ltrs of any type and make and including taking down existing fastners screwcomplete all as specified and directed by Engineer-in-charge. |
| 12 | Supply & Fix of PVC connection pipe dulychromium plated 8 mm dia both end threaded incl brass coupling bolt cone washer complete, length of pipe is not less than 450 mm suitable for Hot/ cold water system and including taking down existing PVC connection complete all as specified and directed by Engineer-in-charge. |
| 13 | Supply & Fix of PVC connection pipedulychromium plated 8 mm dia both end threaded incl brass coupling bolt cone washer complete, length of pipe is not less than 600 mm suitable for Hot/ cold water system and including taking down existing PVC connection complete all as specified and directed by Engineer-in-charge. |
| 14 | Supply & Fix of indicator lamp assembly for geyser andincluding taking down existing indicator lamp assembly complete all as specified and directed by Engineer-in-charge. |
| 15 | Supply & Fix of 3 core PVC insulated and sheathed cable with copper conductor of size 40/0.076 and including taking down existing cable complete all as specified and directed by Engineer-in-charge. |
| 16 | Supply & Fix of inlet & outlet assembly plate suitable for 25 ltrs capacity geyser as per existing pattern and including taking down assembly plate complete all as specified and directed by Engineer-in-charge. |
| 17 | Supply & Fix of inlet & outlet assembly plate suitable for 50 ltrs capacity geyser as per existing pattern and including taking down assembly plate complete all as specified and directed by Engineer-in-charge. |
| 18 | Supply & Fix for Inner tank of geyser of 25 Ltr capacity of made out of steel tank in replecement of leakage tank of geyser andincluding taking down existing inner tank complete all as specified and directed by Engineer-in-charge. |
| 19 | Supply & Fix for Inner tank of geyser of 50 Ltr capacity of made out of steel tank in replecement of leakage tank of geyser andincluding taking down existing inner tank complete all as specified and directed by Engineer-in-charge. |
| 20 | S&F, in repair, stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressurewith crutch or butter fly handle, screwedboth ends for 15mm bore iron pipe or for unions complete all as specified and directed by Engineer-in-charge. |
| 21 | S&F in repair,chromium plated, bib tap,cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge. |
| 22 | M&L for servicing of ETC/FPC type solar water heater of any capacity including taking down, cleaning and descaling of tubes, refixing of tubes, checking and prevention of any leakages, functioning of NRV & gate valves, cleaning of stainless steel hot water tank,checking and repair the heating coil connections, functioning of thermost etc complete all as specified & directed by Engineer-in-charge. Note :- Defective items replaced will be measured under respective items. |
| 23 | Dismantling old defective FPC solar water heater collector of any type any make complete all as specified & directed by Engineer-in-charge. |
| 24 | S&F MNRE registered/approved polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 500 LPD with minimum one year warranty complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F MNRE registered/approved polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 300 LPD with minimum one year warranty complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F MNRE registered/approved polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 200 LPD with minimum one year warranty complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F MNRE registered/approved polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 150 LPD with minimum one year warranty complete all as specified and directed by Engr-in-Charge. |
| 28 | S&F MNRE registered/approved polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 100 LPD with minimum one year warranty complete all as specified and directed by Engr-in-Charge. |
| 29 | Taking down of Old U/S hot water tank of any capacity any make complete all as specified & directed by Engineer-in-charge. |
| 30 | S & F MNRE registered/approved 500 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high densityPUF insulation with thermostat and heater coil 2/3 KW and suitable size ofMS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4for foundation/fixingall as specified and directed by Engr-In-Charge. |
| 31 | S & F MNRE registered/approved 300 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high densityPUF insulation with thermostat and heater coil 2/3 KW and suitable size ofMS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4for foundation/fixingall as specified and directed by Engr-In-Charge. |
| 32 | S & F MNRE registered/approved 200 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high densityPUF insulation with thermostat and heater coil 2/3 KW and suitable size ofMS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4for foundation/fixingall as specified and directed by Engr-In-Charge. |
| 33 | S & F MNRE registered/approved 150 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high densityPUF insulation with thermostat and heater coil 2/3 KW and suitable size ofMS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4for foundation/fixingall as specified and directed by Engr-In-Charge. |
| 34 | S & F MNRE registered/approved 100 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high densityPUF insulation with thermostat and heater coil 2/3 KW and suitable size ofMS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4for foundation/fixingall as specified and directed by Engr-In-Charge. |
| 35 | S & F MNRE registered/approved 200 LPD non pressurised ETC stainless steel hot water tank with inner tank material SS 304with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high densityPUF insulation with 20 tube holes of 58mm diameter and outer PPGI with 20 Nos of58x1800 mm tubes, thermostat and heater coil 2 KW and suitable size ofMS powder coated stand 25x3 mm angle frame with required PCC work 1:2:4for foundation/fixingall as specified and directed by Engr-In-Charge. |
| 36 | S & F MNRE registered/approved 150 LPD non pressurised ETC stainless steel hot water tank with inner tank material SS 304with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with 15 tube holes of 58mm diameter and outer PPGI PUF insulation with 15 Nos of58x1800 mm tubes with thermostat and heater coil 2 KW and suitable size ofMS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4for foundation/fixingall as specified and directed by Engr-In-Charge. |
| 37 | S & F MNRE registered/approved 100 LPD non pressurised ETC stainless steel hot water tank with inner tank material SS 304with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high densityPUF insulationwith 10 tube holes of 58mm diameter and outer PPGI with 10 Nos of58x1800 mm tubes with thermostat and heater coil 2 KW and suitable size ofMS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4for foundation/fixingall as specified and directed by Engr-In-Charge. |
| 38 | S&Ftubes of Evacuated tube collector (ETC) type 1800mm long tubes with inner dia 47mm and outer dia 58mm with frame and frame angle 30 degree complete all as specified and directed by Engr-in-Charge. |
| 39 | S&Ftubes ofEvacuated tube collector (ETC) type 2100mm long tubes with inner dia 47mm and outer dia 58mm with frame and frame angle 30 degree complete all as specified and directed by Engr-in-Charge. |
| 40 | Taking down old U/S , broken pipe of any type any size complete all as specified and directed by Engr-in-Charge. |
| 41 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete of size 20mm including union, bends and tees complete all as specified and directed by Engineer-in-charge. |
| 42 | S&F for heating element for solar water heating system of capacity 2/3 KW andincluding taking down existing heating element complete all as specified & directed by Engineer-in-charge. |
| 43 | S&F for thermostat 3 KW suitable for 100 to 500 litres capacity of solar water heater and including taking down existing thermostat complete all as specified & directed by Engineer-in-charge. |
| 44 | Dismantling & taking out the unserviceable Gun-metal, globe or gate valves of any size from geyser/solarconnection pipe complete all as specified & directed by Engineer-in-charge. |
| 45 | S&F for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends from iron pipe and fixed size 15 mm complete all as specified & directed by Engineer-in-charge. |
| 46 | S&F for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends from iron pipe and fixed size 20 mm complete all as specified & directed by Engineer-in-charge. |
| 47 | S&F for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends from iron pipe and fixed size 25 mm complete all as specified & directed by Engineer-in-charge. |
| 48 | S&F Ball brass valves, high pressure,with polythene float valve 20mm and flynut complete,screwed for iron pipe and including taking out existing valves complete all as specified & directed by Engineer-in-charge. |
| 49 | S&F 20/25 mm dia bore cast iron non return (reflux) valve both flanged ends in swing type design as per IS 5312 Part-1, PN-1.0, including taking out existing valves complete all as specified & directed by Engineer-in-charge. |
| 50 | Supply & Fix forrotational moulded synthetic (HDPE) water storage tankof capacity of 1000litre capacity triple layered, cylindrical vertical with closed top hoisted and fixed in position and including taking down existing tank all as specified in SSR Part-I complete all as specified & directed by Engineer-in-charge. |
| 51 | Supply & Fix forrotational moulded synthetic (HDPE) water storage tankof capacity of 500litre capacity triple layered, cylindrical vertical with closed top hoisted and fixed in position and including taking down existing tank all as specified in SSR Part-I complete all as specified & directed by Engineer-in-charge. |
| 52 | S&F for GItubing 20 mm dia medium grade galvanisedwith necessary fittings such as tees, elbows, bends, reducers, union etc laid in wall ceiling & Floor including all fittings and including taking out existing tubing complete all as specified & directed by Engineer-in-charge. |
| 53 | S&F for GItubing 15 mm dia medium grade galvanisedwith necessary fittings such as tees, elbows, bends, reducers, union etc laid in wall ceiling & Floor including all fittings and including taking out existing tubing complete all as specified & directed by Engineer-in-charge. |
| 54 | S & F sheet metal single pole and neutral enclosure with a two pin and eath plug and socket complete with one single pole MCB 20 Amp 240 V and including taking down existing plug complete all as specified & directed by Engineer-in-charge. |
| 55 | M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.00 Sqmm (FRLS) in PVC conduit including one run of PVC insulated multistrandedcopper conductor nominal cross sectinal area of 4.00 Sqmm (FRLS) of continous earth wire green in colour and including taking down existing submain wiring complete all as specified & directed by Engineer-in-charge.(Note :- Two runs of 4.00 Sqmm cable & one run of 4.00 Sqmm cable shall be paid as one unit length) |
| 56 | M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in PVC casing capingincluding one run of PVC insulated multistrandedcopper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour and including taking down existing submain wiring complete all as specified & directed by Engineer-in-charge.(Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length) |
| 57 | S&F in repair sheet metal enclosure MCB SPN DB 8 way IP 43 with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified & directed by Engineer-in-charge.Make: Legrand Cat pot No 507611or equivalent in Appx \"B\"list of makes. |
| 58 | S&F in repair sheet metal enclosure MCB SPN DB 4 way IP 43 with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified & directed by Engineer-in-charge.Make :- Legrand Cat pot No 507610 or equivalent in Appx \"B\"list of makes. |
| 59 | S&F in repair sheet metal enclosure MCB SPN DB 2 way 240 volts sngle door with magnitic locking system complete all as specified & directed by Engineer-in-charge. |
| 60 | S&F in repair MCB\"s single pole and neutral 32 Amps, 240 Volts,10 KA rapturing capacity \"C\" curve complete all as specified & directed by Engineer-in-charge. |
| 61 | Taking down of old U/S rusted MS structure of solar water tank any type any shape complete all as specified & directed by Engineer-in-charge. |
| 62 | Taking down of old U/S rusted MS structure of cold water tank any type any shape complete all as specified & directed by Engineer-in-charge. |
| 63 | S&F compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like includind caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates grade Fe-290 (Gde E-165), including all lattice bars, stiffeners, gusset plates etc welded together, anchor duly painted with two coats of synthetic enamel paint over and coat of red oxide primer and and forming PCC work and 12mm thick etc complete to avoidany deformation complete all as specified and directed by Engr-In-Charge. |