}

Tender For Procurement Of Medical Consumables Items For Use By The Department Of Cardiovascular And Thoracic Surgery, Goa Medical College, panaji-Goa

Goa Medical College has published Tender For Procurement Of Medical Consumables Items For Use By The Department Of Cardiovascular And Thoracic Surgery, Goa Medical College. Submission Date for this Tender is 03-07-2025. Medical Equipment Tenders in panaji Goa. Bidders can get complete Tender details and download the document.




Tender Notice

49648869
Tender For Procurement Of Medical Consumables Items For Use By The Department Of Cardiovascular And Thoracic Surgery, Goa Medical College
Tender
Indian
Goa
Panaji
03-07-2025

Tender Documents

Tender Details

Procurement Of Medical Consumables Items For Use By The Department Of Cardiovascular And Thoracic Surgery, Goa Medical College-Adult Membrane Oxygenatorwith hard shell Reservoir1. Should have Heparin free, hydrophilic polymer surface balance coating. 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 4000ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 7 ltr/min. 5. Should have priming volume less than 200ml 6. Should have high efficiency heat exchanger positioned in post pump configuration. 7. Venous return port 1/2 with rotating facility. 8. Should have an auto vent facility. 9. port size : arterial outlet, venous outlet 3/8 Venous inlet 1/2membrane surface area 1.8 to 2.5m2 10. Should have sampling port. 11. US FDA and CE approval is required. 2 Adult Membrane Oxygenator with hard shell Reservoir with integrated arterial filter1. Should have Heparin free, hydrophilic polymer surface balance coating. 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 4000ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 7 ltr/min. 5. Should have priming volume less than 200ml 6. Should have high efficiency heat exchanger positioned in post pump configuration. 7. Venous return port 1/2 with rotating facility. 8. Should have an auto vent facility. 9. port size : arterial outlet, venous outlet 3/8 Venous inlet 1/2membrane surface area 1.8 to 2.5m2 10. Should have sampling port. 11. US FDA and CE approval is required. 3 Small adultMembrane Oxygenator with hard shell Reservoir1. Should have a micro porous hollow fiber membrane Oxygenator 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 3500ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 4 ltr/min. 5. Should have priming volume less than 200ml 6. Should have high efficiency heat exchanger positioned in post pump configuration. 7. Venous return port 1/2 with rotating facility. 8. Should have an auto vent facility. 9. port size : arterial outlet, venous outlet 3/8 Venous inlet 3/8 10. Should have sampling port. 11. US FDA and CE approval is required. 4 Small adult MembraneOxygenator with hard shell Reservoir with integrated Arterial filter 1. Should have a micro porous hollow fiber membrane Oxygenator with integrated Arterial filter 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 3500ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 4 ltr/min. 5. Should have priming volume less than 200ml 6. Should have high efficiency heat exchanger positioned in post pump configuration. 7. Venous return port 1/2 with rotating facility. 8. Should have an auto vent facility. 9. port size : arterial outlet, venous outlet 3/8 Venous inlet 3/8 10. Should have sampling port. 11. US FDA and CE approval is required. 5 Paediatric Membraneoxygenatorwith hard shell Reservoir 1. Should have a micro porous hollow fiber membrane Oxygenator 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 3500ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 3.5ltr/min. 5. Should have priming volume less than 140ml 6. Should have high efficiency heat exchanger position in post pump configuration. 7. Venous return port 3/8 with rotating facility and reducers 8. Should have an auto vent facility. 9. pot size : arterial outlet, venous outlet 3/8 Venous inlet 3/8 with reducers 10. US FDA and CE approval is required. 6 Paediatric Membrane Oxygenator with hard shell Reservoir with integrated Arterial filter1. Should have a micro porous hollow fiber membrane Oxygenator with integrated Arterial filter 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 3500ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 3.5ltr/min. 5. Should have priming volume less than 140ml 6. Should have high efficiency heat exchanger position in post pump configuration. 7. Venous return port 3/8 with rotating facility and reducers 8. Should have an auto vent facility. 9. pot size : arterial outlet, venous outlet 3/8 Venous inlet 3/8 with reducers 10. US FDA and CE approval is required. 7 Neonatal Membrane Oxygenatorwith integrated Arterial filter1.Should have venous inlet 1/4. Arterial outlet port 1/4 tubing size. It should have least priming volume less than 60ml. Reservoir capacity should not less then 600ml.Should have reducers and inbuild Arterial filter 2.US FDA and CE approval is required. 8 Prosthetic Heart Valve Bileaflet Mitral Valve Prosthetic Heart Valve Bileaflet( Mitral) 1. Should have Bileaflet pyrolytic carbon disc valve 2. Should haveRadioopaque disc to be visualizes disc to be visualizes on x-ray & fluoroscopy and disc should be MRI compatible. 3. Should be of low profile & thromboresistance Characteristics and Patented Pivot design . 4. Should have Opening angle should be 80 - 85 5. Should have wide range of sizes for mitral 25mm to 35 mm. 6.Should have easy torque rotation and intraoperative adjustment should be possible. 7. Should haveSewing cuff should contain suture marker for accurate placement. 8.Should have Valve to be CE & USFDA approved 9 Prosthetic Heart Valve BileafletAortic ValveProsthetic Heart Valve Bileaflet( Aortic) 1. Should have Bileaflet pyrolytic carbon disc valve 2. Should haveRadioopaque disc to be visualizes disc to be visualizes on x-ray & fluoroscopy and disc should be MRI compatible. 3. Should be of low profile & thromboresistance Characteristics. 4. Should Opening angle should be 80 - 84 5. Should have Wide range of sizes for mitral 17 to 35 mm. 5. Should have Wide range of sizes for mitral 17 to 35 mm. 6. Should Easy torque rotation and intraoperative adjustment should be possible. 7. Should have Sewing cuff should contain suture marker for accurate placement. 8. Valve to be CE & USFDA approved 10 Prosthetic Heart Valve Bileaflet( Mitral) 1. Should have Bileaflet pyrolytic carbon disc valve 2. Should haveRadioopaque disc to be visualizes disc to be visualizes on x-ray & fluoroscopy and disc should be MRI compatible. 3. Should be of low profile & thromboresistance Characteristics. 4. Should Opening angle should be 80 - 84 5. Should have Wide range of sizes for mitral 23 to 35 mm. 6. Should Easy torque rotation and intraoperative adjustment should be possible. 7. Should have Sewing cuff should contain suture marker for accurate placement. 8. Valve to be CE & USFDA approved 11 Prosthetic Heart Valve Bileaflet (Aortic ) 1. Should haveBileaflet pyrolytic carbon disc valve 2. Should haveRadioopaque disc to be visualizes disc to be visualizes on x-ray & fluoroscopy and disc should be MRI compatible. 3. Should be of low profile & thromboresistance Characteristics. 4. Should haveOpening angle should be 80 - 84 5. Should have Wide range of sizes for Aortic 16 to 27 mm. 6. Should have Easy torque rotation and intraoperative adjustment should be possible. 7. Should have Sewing cuff should contain suture marker for accurate placement. 8. Valve to be CE &USFDA approved 12 introducer sheath 8.5FRintroducer sheath to match SG/Cco/CEDV/SVO2/REF Catheters 13 Peritonial Dialysis fluid 14 Peritonial Dialysis catheter 5 Fr 15 Disposable cautery hand switch pencil (valley lab) 16 Disposable Patient Cautery Pad with cable- ADULT(Valley Lab ) 17 PAED. DISP CAUTERY PATIENT PADS(Valley Lab) 18 Neonatal DISP CAUTERY PATIENT PADS(Valley Lab) 19 non absorbable braided polyster2-0 ½ circle double armtc 75 cms suture book 5 white 5 green 25/26 mm with pledgets6 x 3 x 1.5 mm SUTURE BOOK ( FOIL )6foils /box (10 sutures in a foil) 20 Pad roll 4 159 cms 21 CRRT Femoral Cathter 22 Drug Iintravenous sildenafil 23 Injection Levosimendon 12.5g 24 Injection Soda Bi Carbonate 8.5% 25 inj Papavarine 2ml ( 30mg papavarine/ ml ) ampoule 26 Multiple electrolyte solution ( PH;704) 1000ml

Key Value

Document Fees
INR 1000 /-
EMD
INR 1000000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents-1 0 KB
Click here to download tender document Tender Documents-1 0 KB
Click here to download tender document Tender Documents-1 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail