}

Tender For E-Procurement Tender For Fire Safety System Work, Bangalore-Karnataka

Bangalore Bioinnovation Centre has published Tender For E-Procurement Tender For Fire Safety System Work. Submission Date for this Tender is 20-06-2025. Fire Fighting Service Tenders in Bangalore Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

49642969
Tender For E-Procurement Tender For Fire Safety System Work
Tender
Indian
Karnataka
Bangalore
20-06-2025

Tender Documents

Tender Details

E-Procurement Tender For Fire Safety System Work - Supply And Installation Testing And Commissioning Of Pressure Gauge,Supplying And Laying Of Pvc Conduit Long With Accessories In Recess Includin Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. Size - 20 Mm (Ground Floor),Supply Of Addressable 4 Loop Panel (Ground Floor),Supply And Installation Of Relay Module (Ground Floor),System Programming Testing And Commissioning Charge (Ground Floor),Supply And Installation Of 2 Core X 1.5 Mm2, Unarmoured, Frls Outer Sheathed Pvc Insulated Copper Conductor Cable To Connect All Fire Alarm Devices Into Facp (Ground Floor),Supply And Installation Of Manual Call Point (Break Glass Type) With Back Box (Ground Floor),Supply And Installation Of Addressable Type Hooter With Base (Ground Floor),Supply And Installation Of Optical (Photo Electric) Smoke Detector With Base, Junction Box And Other Accessories As Required (Ground Floor),Existing Pipe And Valves Dismandling And Refabrication Work (Ground Floor),Supplying, Installing, Testing And Commissioning Ci Motorized Butterfly Valves 50Mm Dia (Ground Floor),Supplying, Installing, Testing And Commissioning Ci Motorized Butterfly Valves 40Mm Dia (Ground Floor),Supplying, Installing, Testing And Commissioning Ci Motorized Butterfly Valves 100Mm Dia (Ground Floor),Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes 100Mm Dia (Ground Floor),Master Control Unit For Monitoring The Health Of The System,Fire Status Dual Red Led,Having Dual Tone Buzzer To Indicate Fire Status, Construction Of Panel-(20 Swg) C.R Sheet,Finishing Red,Cable Entry Bottom Top Entry 19 Mm Knock Out, Dimension (105X190x80)Mm,Current Consumption 25 Watts,Type Of Tone Dual Tone,90-100 Db At 1 Meter Distance,Output 1 Set Of Potential Free No Nc Com Only, Contact Rating 1A/120V Ac & 2A/24V Dc,Indication Green Led (On) Red Dual Tone Flashing Type,Heat Sensing Tube Red Hr Grade Heat Sensing Tube Red Hr Grade, Single Layer Special Modified Polyamide Material, Tube Id 4Mm Od 6Mm, Operating Pressure 15-18 Bar, Maximum Pressure 30 Bar At Maximum Temperature Of +65 Degree C, Burst Temperature 125 Degree C, Service Life 3-4 Years, Long Term Application, Max Bend In Installation 140Mm, Max Space Between Tubes 250Mm,Ms Cylinder 4 Kg Dlp Assembly With Automatic Valve 4 Kg Ms Cylinder, Dlp Assembly With Automatic Valve,Fk-5-1- 12 Ul Listed Clean Agent, Mounting Bracket, Spring Top Connector , Pressure Switch , End Of Line Adaptor.,Supplying And Laying Of Pvc Conduit Long With Accessories In Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. Size - 20 Mm (External),System Programming Testing And Commissioning Charge (External),Supply And Installation Of 2 Core X 1.5 Mm2, Unarmoured, Frls Outer Sheathed Pvc Insulated Copper Conductor Cable To Connect All Fire Alarm Devices Into Facp (External),Installation Of Old Mcp (External),Supply And Installation Of Manual Call Point (Break Glass Type) With Back Box (External),Installation Of Old Hooter (External),Supply And Installation Of Addressable Type Hooter With Base (External),Installation Of Smoke Detector (External),Supply And Installation Of Booster Amplifier Including Necessory Control Wires, Jacks Etc. Complete.,Supply And Installation Of 6W Celing Mounding Speaker (Pa Systems),Supply And Installation Of 2 Core X 1.5 Mm2, Unarmoured, Frls Outer Sheathed Pvc Insulated Copper Conductor Cable To Connect All Fire Alarm Devices Into Facp (Pa Systems),System Programming Testing And Commissioning Charge (1St Floor),Supply And Installation Of 2 Core X 1.5 Mm2, Unarmoured, Frls Outer Sheathed Pvc Insulated Copper Conductor Cable To Connect All Fire Alarm Devices Into Facp,Supply And Installation Of Relay Module,Supply And Installation Of Manual Call Point (Break Glass Type) With Back Box,Supply And Installation Of Addressable Type Hooter With Base,Supply And Installation Of Optical (Photo Electric) Smoke Detector With Base, Junction Box And Other Accessories As Required,Supply Of Mechanical Foam,Mechanical Foam Tank 2000 Ltr (Civil Work Clint Scope),Foam Water Sprinkler,Supplying, Installing, Testing And Commissioning Ci Motorised Butterfly Valves ( Pn 16) Slim Seal Standared Lever Operated Type Confirming To Bs - 5155 With Required Flanges,Nuts, Bolts Etc. Complete. 40Mm Dia,Supplying, Installing, Testing And Commissioning Ci Motorised Butterfly Valves ( Pn 16) Slim Seal Standared Lever Operated Type Confirming To Bs - 5155 With Required Flanges,Nuts, Bolts Etc. Complete. 50Mm Dia,Supplying, Installing, Testing And Commissioning Ci Motorised Butterfly Valves ( Pn 16) Slim Seal Standared Lever Operated Type Confirming To Bs - 5155 With Required Flanges,Nuts, Bolts Etc. Complete. 80Mm Dia,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 25Mm Dia,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 32Mm Dia,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 40Mm Dia,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 50Mm Dia,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 65Mm Dia,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 80Mm Dia

Key Value

Document Fees
INR 500 /-
EMD
INR 376250.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail