Tender For Rectification Of Cable Fault,Electrical Wiring At Civil Camp Office,Other Allied Works At Kalyaneswari Headworks Site Under Rcfa Part-I Water Supply Scheme. Sl. No. Item Description 1 Electrical Wiring Portion (Supply And Delivery Of Foll, Paschim Bardhaman-West Bengal

Public Health And Engineering Department has published Tender For Rectification Of Cable Fault,Electrical Wiring At Civil Camp Office,Other Allied Works At Kalyaneswari Headworks Site Under Rcfa Part-I Water Supply Scheme. Sl. No. Item Description 1 Electrical Wiring Portion (Supply And Delivery Of Foll. Submission Date for this Tender is 02-07-2025. Tree Cutting Tenders in Paschim Bardhaman West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

49638139
Tender For Rectification Of Cable Fault,Electrical Wiring At Civil Camp Office,Other Allied Works At Kalyaneswari Headworks Site Under Rcfa Part-I Water Supply Scheme. Sl. No. Item Description 1 Electrical Wiring Portion (Supply And Delivery Of Foll
Tender
Indian
West Bengal
Paschim Bardhaman
02-07-2025

Tender Documents

Tender Details

Tender For Rectification of cable fault,electrical wiring at civil camp office,Other allied works at Kalyaneswari Headworks site under RCFA Part-I Water Supply Scheme. Sl. No. Item Description 1 Electrical wiring portion (Supply and delivery of Following materials):- 2 4 ft. long 36 Watt LED Tubelight Slim LED batten with aluminium housing and polycarbonate diffuser is an ideal replacement solution for existing battens/fluorescent lamps with elegantly designed end caps with 4000 lumen Output.(Make-Approved Make) 3 14 Watt LED lamp with 1400 lumen output.(Make-Approved Make) 4 4 ft. long 22 Watt LED Tubelight Slim LED batten with aluminium housing and polycarbonate diffuser is an ideal replacement solution for existing battens/fluorescent lamps with elegantly designed end caps with 2200 lumen Output.(Make-Approved Make) 5 Supply and fitting, fixing of 32 Amp, Triple Pole with Neutral Link, 415 Vac, 50 Hz.(Make:-Havells) 6 Supplying and fixing 6-32 Amp, TP, MCB, 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. 7 Supply and fitting, fixing MCB Enclosure 4-way. 8 4 Core X 25 Sqmm, 1.1 KV Grade XLPE insulatedAl.Ar Cable as per IS:7098(Part-I)2011.(Make:-Approved Make) 9 Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. 10 Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works.-19 mm dia 3 mm thick polythene pipe without earth continuity wire. 11 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required-3 x 36/0.3 (2.5 sqmm) 12 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish-(2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC)-Average run 8 mtr. 13 On Board, 5 Amp, 3 Pin Plug Socket. 14 Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. 15 Supplying and fixing double door Horizontal 4 Way, TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Enclosure (DHDPTHODRW04)(Make:-Havells)(Just for replacement) 16 Wiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.-2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 17 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top coveron wall incl.necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] 18 Average run 10 mtr. 19 Average run 8 mtr. 20 Supply and fitting, fixing of 3 Blade 1200 mm Sweep ceiling fan, 220V-240V,50 Hz,AC. 21 Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cuttingbakelite/perspex top cover incl. making necy. connectionsetc. 22 Supply & fixing the A. C. starter 25 Amp, 25 Amp Plug top & socket & composite flush type 25 Amp 5 pin switch board(3 Module) with piano type switch( 25 A 1 Way Switch), 25 Amp MCB with Box(1 Module), as per requirement by engaging skilled electrician as per direction. (Make-Havells/Approved make). 23 Supplying and fixing 240/415 V, SP, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make:-L & K) 24 Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. 25 Fixing only Single LED Batten light fitting complete with all accessories directly on wall by screws etc. 26 Fitting & fixing of the indoor lighting luminaries along with new & old accessories to the pole etc as per direction of EIC. 27 Jungle cutting, cleaning compound premises or shrubs, plants, jungles etc. by cutting and removingas directed.(Specific permission of Engineer in Charge prior to execution will be necessary.) 28 Add GST @ 18% 29 Add CESS @ 1%

Key Value

Document Fees
Refer document
EMD
INR 16000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail