| 1 | Excavating in trenches, in any type of soilnot exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soilconcrete all as specified and directed. |
| 2 | All as per item No1.00 above but for each additional 1.5 m or part thereof in depth beyond the first 1.50m |
| 3 | M&L for Cement concrete1:2:4 type B 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed. |
| 4 | M&L for Cement concrete1:4:8 type D 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed. |
| 5 | M&L for Cement concrete1:3:6 type C 1 (using 20 mm graded stone aggregate) as in roof kerbs or pole coupling of size 300x300 mm or chamfered on edgesconcrete all as specified and directed. |
| 6 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm eachconcrete all as specified and directed. |
| 7 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting pointconcrete all as specified and directed. |
| 8 | M&L for Sand cushioning with fine dry unwashed sand in trenches for protection of cablesconcrete all as specified and directed.Note: Punned thickness shall be measured and paid. |
| 9 | Supply and layingflyash brick modular size, laid in trenches as cable covers concrete all as specified and directed. |
| 10 | S&F in repairs Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall concrete all as specified and directed. |
| 11 | S&F in repairs Steel tubes, galvanised, light grade, ISI marked 80 mm bore for protection of cable under floor, road and on wall concrete all as specified and directed. |
| 12 | M&Lfor dismantaling of old cracked /unserviceable PCC poles /MS pole struts any type and size incl deposited at a suitable locations not more than 50 RM away complete all as specified and as directed by Engr-In- Charge. |
| 13 | Supply and fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 ,9.00 metres long, erected to truely vertical position, painting externaly embedded portion in PCC with black bitumenous paint and externally exposed to view portion with aluminium paint in two coats, making five alternate strips 30cm wide with black and yellow paint in two coats, marking MES number with black paint completeall as specified and as directed. Note : Excavation and PCC will be measured and paid separately under respective items. |
| 14 | M&L for attending external electric complaints by opening / disconnecting the electrical connection of defective / burnt out underground LT cable of any size & any core from main switch / DB / junction box / LT panel / L T O/H line etc. and taking out therequired length of cable from existing loop and remove/ cut the defective cable,replace the same with new cable as per existing size including providing necessarythimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc. and make electic connection as functionable in all repspects including testing on completion all as specified and directed by Engineer-in-charge. |
| 15 | Note:- (A) The rate quoted shall deemed to be inclusive of the following:- (i) Necessary earth work excavation in any type of soil, returning, filling and removing extra soil.(ii) Existing bricks, sand,GI protection pipe etc. shall be removed carefully and stacks neatly near site and same shall be re- laid after attending fault/defect.(iii)Distrubed surface of road, floor etc. shall be make good to match with existing surface. (iv) Required numbers of electrician and helper shall be deployed for attending complaints regulerly on daily basis and contractor shall collect the complaints details from complaint cell of AGE E/M No.1 and same shall be rectified/ attanded within an hour and report shall be submitted to Engineer-in-charge or their authorised representative.(B) Please note that payment shall be made to contractor one time only for this items. if any fault/ default occured again on the same location/ DB/junction box/panel during currency of contract, the same shall be rectified by the contractor without any extra cost to Govt. in terms of condition 46 of IAFW of genral condition of contracts.(C) Additional bricks,sand,GI pipe etc. as required for cable protection and cushioning shall be measured and paid separetely under relevent item. |
| 16 | M&L for dismantling / disconnecting / removing the faulty / burnt out overheadconductor of any type / size from insulator of HT / LT pole any type by makingproper shutdown from department and removingof tree / branches if any fell on Over Head Line,loose the binding wire in each insulators and disconnecting cable connection as required, remove the burnt / damage conductor / earth wire and making necessary joint with new ACSR conductor of suitable size as per existing as directed, restretching all the loose spans of ACSR conductors, earth wire etc. with insulator and providing binding wire of existing size to tigheting and making LT/HT cable in existing position and make electric connection as functionable in all respects including testing on completion complete all as specified and directed by Engineer in charge. |
| 17 | NOTE:The rate quoted shall deemed to be inclusive of the following:-(i) Tools and plants such as ladder,rope, cutter, axes, knife etc. as required for cutting and removing tree/branches if any fall on OH line.(ii) Insulator,binding wire etc. as required in addition to existing shall be provided by the contractor.(iii) Required numbers of Elecrician and helper shall be deployed for attending complaint regularly on daily basis and contractor shall collect the complaint details from complaint cell of AGE E/M No. 1(iv) Additional ACSR conductor and earth wire shall be measured and paid separetely under relevantitems. |
| 18 | S&F in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer in charge. |
| 19 | S&F in replacement LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer in charge. |
| 20 | Supply only LED driver of capacity 60/70 watts rating 240 Volt, 50 Hz complete all as specified.Make:- Philips/ Bajaj/ Havells as approved by GE. |
| 21 | S&F in replacement all-in -one integrated solar street light 24/25 W compact ,Asthetic, Ecofriendly & Modern integrated solar streetlight in extruded aluminium construction with high efficiency monocrystalline silicon photo voltaic panel,high efficacy SMD LED 6500 K having secondary lens optics for street lighting distribution,high performance lithium battery, MPPT charge controller and intelligent control module/sensor with higher reliability, long service life,suitable for easy and quick installation. |
| 22 | Taking down old unserviceable capacitor of any capacity and replace with new Duca Power XD capacitor, withstand Harmonic overloads upto 4 Amp Max current, low losses0.2 watt/KVAR, three phase, temperature range (-) 25 degree centigrate to 70 degree centigrate of the following rating :- |
| 23 | (a) 5 KVAR |
| 24 | (b) 10 KVAR |
| 25 | (c) 25 KVAR |
| 26 | Trimming/pruning of tree branches touching to the LT over head line or near to the LT over head line as per direction of AGE E/M /JE in charge complete including removing the tree branches from site complete all as specified and directed.NOTE - (a) Prior shut-down shall be obtained from concerned JE / AGE E/M before taking out the trimming work , by contractor(b) span from one pole to next pole (30 to 50 m) will be considered and measured as a job. (c) T & P such as ladder , rope, cutter , axes and safety of workmen, will be provided by the contractor |
| 27 | S&F in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm complete all as specified and directed. |
| 28 | S&F in replacement XLPE insulated and PVCarmoured heavy duty electric cables with aluminum conductor, 1100 volt grade of size10 sqmm,4.0 core in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with suitable size aluminum lugs and testing complete all as specified & directed.Note : (a) Excavation shall be measured and paid seperately under respective items of Sch \"A\" . (b) Allredq lugs of suitable sizes according to laying of cable measured and paid seperately under respective items of Sch \"A\" /BOQ |
| 29 | All as above Item No. 23.00, but 16 Sqmm 4.0 core. |
| 30 | All as above Item No. 23.00, but 25 Sqmm 3.5 core. |
| 31 | All as above Item No. 23.00, but 35 Sqmm 3.5 core. |
| 32 | All as above Item No. 23.00, but 50 Sqmm 3.5 core. |
| 33 | All as above Item No. 23.00, but 70 Sqmm 3.5 core. |
| 34 | All as above Item No. 23.00,but 95 Sqmm 3.5 core. |
| 35 | All as above Item No. 23.00, but 120 Sqmm 3.5 core. |
| 36 | All as above Item No. 23.00, but 185 Sqmm 3.5 core. |
| 37 | S&F in repairs Aluminium lugs of size 16 sqmm |
| 38 | S&F in repairs Aluminium lugs of size 25 sqmm |
| 39 | S&F in repairs Aluminium lugs of size 35 sqmm |
| 40 | S&F in repairs Aluminium lugs of size 50 sqmm |
| 41 | S&F in repairs Aluminium lugs of size 70 sqmm |
| 42 | S&F in repairsAluminium lugs of size 95 sqmm |
| 43 | S&F in repairs Aluminium lugs of size 120 sqmm |
| 44 | S&F in repairs Aluminium lugs of size 185 sqmm |
| 45 | S&F in repairs Aluminium lugs of size 240 sqmm |
| 46 | S&F in replacementMCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified & directed. |
| 47 | All as above Item No. 33.00, but capacity of 125 amps. |
| 48 | S&F in replacementMCCB 3- pole, 415 volts, adjustable type 160 amps with breaking capacity 36 KA complete all as specified & directed. |
| 49 | All as above Item No. 35.00,but 200 amps. |
| 50 | All as above Item No. 35.00, but 250 amps. |
| 51 | All as above Item No. 35.00, but 350 amps. |
| 52 | All as above Item No. 35.00, but 400 amps. |
| 53 | S&F in replacementMCCB 4 pole, 415 volts, adjustable type 250 amps with breaking capacity 36 KA complete all as specified & directed. |
| 54 | All as above Item No. 40.00, but 350 amps. |
| 55 | All as above Item No. 40.00,but 400 amps. |
| 56 | S&F in replacement pin type polymer,insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified & directed. |
| 57 | S&F in replacement shackle type polymer, vitreous,insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 75 mm and max dia 90 mm suitable for working pressure 1100 volts grade complete all as specified & directed. |
| 58 | S&F in replacement disc insulator, polymer, 145 mm high and 255,, dia suitable forsingle disc asst for tension with tension clamps for conductors, working pressure 11000 volts grade complete all as specified & directed. |
| 59 | Fixing only (in repairs) of aluminium conductor steel re inforced, any sizes for replacement of broken over head line conductor of any type and length as required at site including removing of foreign objects/ obstacle, if any onthe over head line, complete all as specified and directed.Note:- New ACSR conductor used for replacementwill be measured (supply only) and paid separately. |
| 60 | Supplyaluminium conductor steel re-inforced, any sizes complete all as specified & directed. |
| 61 | Restringing ofloose over headconductor/GI earth wireof any size and typeafter untyeingbinding wire from insulators/cross arms to achieve permissible sag limit of over head lineincluding new binding wire of proper size and pruning of tree branches of concerned spans and jointing of jumpers properly complete all as specified and directed at site. Note:- (i) One job consist one span of 3-phase, 4-wire over head line.(ii) The distance of one span is approx 30 to 50m. |
| 62 | M&L for repalcement straight through joint ( Epoxy joint) for following size PVC insulated and sheathed aluminium cable complete for following sizes :- |
| 63 | (a) 3.5 core, 50 sq mm |
| 64 | (b) 3.5 core ,70 sqmm |
| 65 | (c)3.5 core , 95 sqmm |
| 66 | (d)3.5 core , 120 sqmm to 150 sqmm |
| 67 | (e)3.5 core , 185 sqmm |
| 68 | Disconnecting exiting incoming and outgoing cables from exiting old LT panel of required length after taking down power shut down and exiting all safety precautions for human safety , including reconnecting the all connections to bus bar after cleaning the dust from LT panel , change the aluminium lugs of suitable size , proper insulate the cable with high classof LT insulating tape with proper colour coding, complete with its accessories and setting side at safe place for further disposal complete all as specified and directed at site. NOTE-(a)All ammeter , voltmeter and selector switch must be functioning in proper way (reading should be matched with multimeter or clamp on meter up toerror 5 precent)(b) fuse or mcb seperatelly for ammeter and voltmeter in LT panel is supplied by contractor (c) all nut bolts with wiser of suitable size in LTpanel is supplied by contractor |
| 69 | M&L for painting and welding (both weldind and painting whenever required) of old exiting LT panel of any size with two coat of synthethic enemelled paintof approved colour internally and externally , after cleaning to rusted portion of paneland finishing the surfaces including one coat of primer by Skilled Painter complete all as specified and as directed. NOTE-Repairs to LTpanel boards complete incl. necessary welding works to door , replacement of unserviceable hings and all drop bolt , etc. |
| 70 | S&F in replacement ACthree phase keypad based, BIS marked pre-payment static Energy meter ,current rating 10-60 /20-100 A , 240 V (L-N) with bluetooth compatibility and mobile application complete all as specified and as directed. Make:- SECURE/L&T/HPL as approved by GENote :- Old electric meter shall be handed over to AGEE/M store Yard. |
| 71 | S&F in replacement AC single phase keypad based,BIS marked pre-payment static Energy meter ,current rating 10-60 /20-100 A , 240 V (L-N) With bluetooth compatibility and mobile application complete all as specified and as directed.Make:- SECURE/L&T/HPL as approved by GENote :- Old electric meter shall be handed over to AGEE/M store Yard. |
| 72 | S&F in replacementAC Single phase two wire static watt hour meter (Electronic KWH Energy meter) of rating 5-30 A, class 1.0,240 V,50 Hz,LCD Display complete all as specified and as directed. Make:- HPL Cat part No SPPB1310000000OC00 / SECURE / L&T as approved by GENote :- Old electric meter shall be handed over to AGEE/M store Yard. |
| 73 | S&F in replacementAC Three- phase, static watt hour meter (Electronic KWH Energy meter) of rating 10-60 A, class 1.0,240 V (L-N) ,50 Hz, LCD Display.Make:- HPLor equivalent in SECURE / L&TNote :- Old electric meter shall be handed over to AGEE/M store Yard. |
| 74 | S&F in replacement three phase contactor 5kW of load capacity 20-25 Amps, incoming-Outgoing MCB (03 Nos each) rating 20-25 Amps complete all as specified and as directed . Make:- ABB/L&T/Schneider as approved by GE |
| 75 | S&F in replacement Single phase contactor 5kW of load capacity 40 Amps, Incoming-Outgoing MCB rating 32-40 Amps & Circuit wiring minimum 10 Sqmm complete all as specified and as directed by Engr-in-Charge. Make:- ABB/L&T/Schneider as approved by GE |
| 76 | S&F in replacement MCB TPN, 415V, 40 Amps, \"B\" series complete incl all connections. |
| 77 | S&F in replacement MCB TPN, 415V, 63 Amps, \"B\" series complete includingall connections complete all as specified and as directed. |
| 78 | S&F in replacement MCB SPN, 32 Amps,240V, complete includingall connections complete all as specified and as directed. |
| 79 | S&F in replacement MCB SP 6 to 32 Amps 230 Volt complete all as specified and as direcetd by Engr-in-Charge. |
| 80 | M&L forPainting to street light pole of steel tubular swaged/ swan neck typewith two coat of aluminiumpaint after cleaning to rusted portion of pole and finishing the surfaces including one coat primer top to bottom, painting on cross arms/FI clamps/street liht brackets of any type including makingalternative blak and yellow strip with synthethic enemelled paintup to 1.5 Mtr height from ground level & writing of polenumbers with black paint onpoles complete all as specified and directed. |
| 81 | M&L for painting of LT PCC poles 9.00m. with acrylic paint after apply two coat of cement base primer and making the surface smooth including painting of cross arms, clamps, etc with two coat of aluminium paint and providing alternative strip of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 m height, writing of pole numbers in yellow circle 15 cm withblack paint on poles complete all as specified and directed. |
| 82 | Supply and Errecting (in replacement) LT Panel outdoor type mounted and fixed with PCC foundation , made out of MS sheet factory assembled and factory fabricated out of 3.15 mm thick sheet steel with suitable size MS angle duly spray painted with two coat of gray synthetic enamel paint over one coat of red oxide zinc chrome primer after preparation of surface , with required civil work & wiring with copper cable of suitable size, connecting including indication lamp LED type for each phase , Aluminium bus bar - 400 Amps rating - 03 Nos. for phases and 400 Amp rating - 01 No. for neutral, incl inbuilt industrial type locking arrangments , front openable incl necessary arrangments for fixing with suitable, clamps,nuts, bolts wahers etc, & incl Danger notice board , feeder marked,testing and commissioning , size 600 x600x 300 mm, complete all as specified and directed by Engr-in-Charge. |
| 83 | S&F in replacement cable path indicator made of MS sheet of size 200 mm x 150 mm x 3 mm thick and spot welding withangle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-1( using 12.5 mm graded granite stone aggregate) including providing one coat of synthetic enamlled black paint over one coat of red oxide primer and sign writing with white paint showing size of cable HT /LT complete all as specified & directed . |
| 84 | Cutting the Existing bituminouse road for passing of UG Cable in road crossing and making good the disturbed surgace of road to match the existing old surfaces complete all as specified and directed by Engr-in-Charge. |
| 85 | S&Fin replacementmoulding compound Street light junction box of size 250 mm x 200 mm x 105mm complete with shock and rust proof, termite resistant, tamper proof , front openable type and including suitable provisionfor single phase, two wire cable (size upto 25 Sqmm 2 Core) incomming & outgoing loop -in loop connection and including one no. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole / wallcomplete all as specified and directed by Engr-in-Charge.. Make - Sintex Cat part No GSJB 2520/Hensel/ABB as approved by GE |
| 86 | M&L for Earthing Supply, installation¸ testing & commissioning of waterless and maintenance free earthing with earth (grounding) electrodes and PCC pit with cover (in replacement) complete all as specified and directed:- (a) Earth Electrode: 17.2 mm dia copper bonded MS rod shall be in-situ cast in electrically conductive concrete earth enhancing material mixed with cement. Size of embedding of electrically conductive concrete earth enhancing material shall be 85 mm dia. The electrode of 3000mm should be able to withstand a fault current upto 35kA (Peak) for 1 second duly tested from recognized National Test laboratories like CPRI, ERDA, ERTL, MSME etc (not more than 18 months old).The ratio of mixing of conductive concrete to cement should be 3:1. Other hardware like nut, bolts and washers should be of stainless steel. connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 87 | M & L for Earthingin repairs complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.5 of MESSSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed. |