Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-06-2025 | Tender documents | Other | 03-07-2025 |
| Sl. No. | Item Description |
| 1 | M & L for Dewatering Water from Pressed Steel Storage Water Tank 46800 Litre Capacity, having 12.00 Metre High Steel Stagging, Cleaning and Removing all Mosses, Algae, Dirts, etc. from the Walls & Floor of Water Tank, Removal of Dirty Water with Sludges and disposed off from the Site as diredted, Rubbing Walls, Floor, Ceilling surfaces with Gunny Bag after sprinkling of Bleaching Powder and Wash thoroughly with Fresh Water including Cleaning of Outlet Pipes, Stop Valves, Gate Valves by Taking out Pipe Lines with Stop Valves, Gate Valves, etc. and all Accessories, Re-fixing the same after Cleaning including Float Valve with Float Arm to Original Position, Writing Letters \"TANK CLEANED ON : DD.MM.YYYY\" (i.e. Date of Cleaning), exc. 100mm but not exc. 200mm in height and 15mm in wide with White Paint on Black Back ground on the Front/ Road Side/Face of the Tank, complete all as specified and as directed.(NOTE :-(a) Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Steel Storage Water Tank will be arranged by the Contractor at his Own Arrangement & Cost and the same will be included in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.) |
| 2 | M & L for Preparation of oldpainted steel internal surfaces of Pressed steel water storage tank of any capacity at a height of 12m stagingincluding all connected accessories like GI pipes, valves and other fittings etc by removing rust etc from the surfaces by rubbing with wire brush etc and applying one coat of black bitumenous paint (For drinking purpose) complete all as specified and directed. |
| 3 | M & L for Preparation of oldpainted steel external surfaces of Pressed steel water storage tank of any capacity at a height of 12m staging and Iron Removal plant of any capacity including all connected accessories like steel staging, GI pipes, valves and other fittings etc by removing rust etc from the surfaces by rubbing with wire brush etc and applying two coats of aluminium paint complete all as specified and directed. |
| 4 | M & L for Dewatering Water from RCC overhead Water Tank 50000 Litre Capacity, having 12.00 Metre High Steel Stagging, Cleaning and Removing all Mosses, Algae, Dirts, etc. from the Walls & Floor of Water Tank, Removal of Dirty Water with Sludges and disposed off from the Site as diredted, Rubbing Walls, Floor, Ceilling surfaces with Gunny Bag after sprinkling of Bleaching Powder and Wash thoroughly with Fresh Water including Cleaning of Outlet Pipes, Stop Valves, Gate Valves by Taking out Pipe Lines with Stop Valves, Gate Valves, etc. and all Accessories, Re-fixing the same after Cleaning including Float Valve with Float Arm to Original Position, Writing Letters \"TANK CLEANED ON : DD.MM.YYYY\" (i.e. Date of Cleaning), exc. 100mm but not exc. 200mm in height and 15mm in wide with White Paint on Black Back ground on the Front/ Road Side/Face of the Tank, complete all as specified and as directed.(NOTE :-(a) Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside ofRCC overhead tank will be arranged by the Contractor at his Own Arrangement & Cost and the same will be included in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.) |
| 5 | M & L for cleaning of PVC Building service tanks of capacity 5000 litres situated at various places by removing the float valve of any size carefully and keeping it safe for refixing, inspecting the float valves, check nuts and nipples for serviceability, inspecting the tanks for cracks if any, bailing out the accumulated water at the bottom and removing the complete silt from the bottom of the tank and thereafter cleaning and rubbing inner surface using bleaching powder and wire brushes, taking out all scales, dirt etc. and cleaning of tank with fresh water including writing on the out side of the tank“CLEANDED ON: DD/MM/YY”with synthetic enamel paint with letter size 10cm high in white color, over a black background of appropriate size,refixing of float valve and check nuts etc including dismantling and reconnecting and refixing in psoition complete all as specified and directed. |
| 6 | M & L for Dewatering of RCC Semi underground sump for Raw/Treated water of size 17.5m x 5.6m x 3.5m, Cleaning and Removing all Mosses, Algae, Dirts, etc. from the Walls & Floor of sump, Removal of Dirty Water with Sludges and disposed off from the Site as directed, Rubbing Walls, Floor, Ceilling surfaces with Gunny Bag after sprinkling of Bleaching Powder and Wash thoroughly with Fresh Water including Cleaning of Outlet Pipes, Stop Valves, Gate Valves by Taking out Pipe Lines with Stop Valves, Gate Valves, etc. and all Accessories, Re-fixing the same after Cleaning including Float Valve with Float Arm to Original Position, Writing Letters \"TANK CLEANED ON : DD.MM.YYYY\" (i.e. Date of Cleaning), exc. 100mm but not exc. 200mm in height and 15mm in wide with White Paint on Black Back ground on the Front/ Road Side/Face of the Tank, complete all as specified and as directed. |
| 7 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 8 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 9 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting pointcomplete all as specified and directed. |
| 10 | Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 11 | Taking up or down 25 or 32 mm bore, Steel/PPR tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 12 | Taking up or down 40 or 50mm bore, Steel/PPRtubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 13 | Taking up or down 80/90mm bore, Steel/PPRtubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 14 | Taking up or down 100/110mm bore, Steel/PPRtubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 15 | M & L for cast iron fittings for spigot and socketed pipe, such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or socket andpigot) collars, caps and plugs etc upto 150mm bore including taking up/down existing unserviceable fittingscomplete all as specified and directed. |
| 16 | Supply, laying, connection and testing, 110mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed |
| 17 | Supply, laying, connection and testing, 90mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed |
| 18 | Supply, laying, connection and testing, 50mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed |
| 19 | Supply, laying, connection and testing, 32mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed |
| 20 | Supply, laying, connection and testing, 25mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed |
| 21 | Supply, laying, connection and testing 100mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 22 | Supply, laying, connection and testing 80mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 23 | Supply, laying, connection and testing 50mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 24 | Supply, laying, connection and testing 40mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 25 | Supply, laying, connection and testing 25mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 26 | Supply, laying, connection and testing 20mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 27 | S & F in repair 63 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed. |
| 28 | S & F in repair 25 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed. |
| 29 | S & F in repair Bib taps, medium, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and as directed. |
| 30 | S & F in repairs, 20 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 31 | S & F in repair 25 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 32 | S & F in repairs, 40 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 33 | S & F in repairs, 50 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 34 | S & F 80mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket including taking out existing one complete all as specified and directed. |
| 35 | S & F 100mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket including taking out existing one complete all as specified and directed. |
| 36 | S & F 150mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket including taking out existing one complete all as specified and directed. |
| 37 | S & F 200mm bore Cast iron sluice valve both end flanged class PN 1.6 conforming to rrelevant IS with iron wheel head and brass spindle including necessary joint with nuts bolt, washer, rubber or fiber board gasket, etc including taking down old one complete all as specified and directed |
| 38 | S & F 100 mm bore, Cast iron Non-return (reflux)valve, flange type with by-pass arrangement suitable for 100 mm dia water mains conforming to IS-5312 Part-I class PN 1.6 including takind down existing one complete all as specified and directed. |
| 39 | S & F 150 mm bore, Cast iron Non-return (reflux)valve, flange type with by-pass arrangement suitable for 150 mm dia water mains conforming to IS-5312 Part-I class PN 1.6 including takind down existing one complete all as specified and directed. |
| 40 | S & F 200 mm bore, Cast iron Non-return (reflux)valve, flange type with by-pass arrangement suitable for 150 mm dia water mains conforming to IS-5312 Part-I class PN 1.6 including takind down existing one complete all as specified and directed. |
| 41 | M & L for construction of brick masonry valve pit of size 75cmx75cmx90cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation &earth work in soft/loose soil and demolition of existing one complete as specified and directed all as per relevant TD drawing. (Note : Drawing not attached with the tender document.However, the same can be seen in GE/AGE E/M office during working hours) |
| 42 | M & L for construction of brick masonry valve pit of size 100 cm x 100 cm x 90 cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation &earth work in soft/loose soil and demolition of existing one complete as specified and directed all as per relevant TD drawing. (Note : Drawing not attached with the tender document.However, the same can be seen in GE/AGE E/M office during working hours) |
| 43 | S & F Mild steel column pipe, 65 mm bore, heavy duty, flanged type complete, (3 m long) with nuts, bolts, gaskets & washers andprovision of cable entry system and duly painted with two coats of black bitumenous paint (internally) and two coats of synthetic enamelled paint (externally) over a coat of red oxide zinc chrome primer including taking down old unserviceable pipe complete all as specified and directed.(Make : Jindal/Bansal/TATA) |
| 44 | Supply only High strength calcium Hypo Chloride, 65-70% chlorine content, Calcium based granular disinfectant for water treatment chemical complete all as per the following specifications:(a) Available chlorine: Minimum 65% by mnass(b) Stability: Maximum 1/15 loss of chlorine on the basis of available chloride(c) Particle size (passing through 1.70mm IS Sieve): Minimum 99.5% by mass(d) Water insoluble matter: Maximum 6%(e) Calcium hydroxide: 4% maximum (f) Sodium chloride: 15% maximum(g) Description/Appearance: Dry free flowing and free from lumps(h) Toxic & undesirable substance: Should not induce substances beyond acceptable limit as given in IS-10500 (2012) in treatment and disinfected water(j) Packing: 20-25 Kg/ 40-45 Kg drums(Note: Make shall be as per approved makes of E-in-C. Testiting certifcate of chemical shall be submitted by the contractor before supply). |
| 45 | Supply only Lime for water treatment chemical complete all as specified and directed. |
| 46 | Supply only Alum Crystal for water treatment chemical complete all as specified and directed. |
| 47 | Supply only Polymer INDFLOC 238 for water treatment chemical complete all as specified and directed. |
| 48 | M & L for servicing & painting complete the cylinderical shaped OXIDATION CHAMBER made out of MS sheet, fixed over PCC blocks at 60cm to 100cm height from ground level installed at water supply installations as componant of water treatment & iron removal plant of capacity @ 5000GPH bore well raw water treatment to potable water and arresting leakages by necessary welding patch works, replacement of old existing catalyst (MnO2) with using new life MnO2 compound including filling by taking out (unloading) after opening the top and side manhole covers by removing nuts, bolts & washers, de-scaling & prepairing the surfaces for painting the complete oxidation chamberthoroghly both inside & outside wall surfaces by using wire brush, sand papers etc, replacement of faulty pressure gauges, gate valves, butterfly valves of any size, piping network, butterfly valves, painting etc as directed, alum & soda pots etc with proper care and applying one coat of paint as per the existing specification on both internally and externally and re-fixing of manhole covers by tightning nuts, bolts, washers & new rubber packing sheets to the shape and size as per site requirement including removing the waste materials from water supply installations minimum50m away, spreading, levelling, rinsing & testing the newly filled MnO2 at least twice before water supply to the users complete in all respect all as specified and directed by the Engr-in-Charge.(Note :(i) Cost of minor spares i.e. cotton waste, nuts, bolts, washers, rubber packing sheet for re-fixing of manhole covers etc deemed to be included in the quoted rates.(ii) Cost of cleaning, brushing, de-scaling with sand paper and painting internally & externally incl piping network etc deemed to be included in the quoted rates.(iii) Cost of major spares/items i.e. new MnO2, pressure gauges, alum / soda pots, butterfly valves, gate valves of any size will be measured and paid seperataly under relevant item of BoQ as supply only). |
| 49 | All as per Serial item No. 48 above but for 10000 GPH bore well capacity complete and ditto |
| 50 | Supply only new MnO2 compound as catalytic media of size 1\" x 1/2\", free from any foreign materials suitable for drinking water treatment plant complete all as specified and diretced. |
| 51 | M & L for servicing & painting complete the cylinderical shaped IRON REMOVING PLANT made out of MS sheet, fixed over PCC blocks at 60cm to 100cm height from ground level installed at water supply installations as componant of water treatment capacity @ 5000GPH bore well raw water treatment to potable water and arresting leakages by necessary welding patch works, replacement of old existing filter media of any type & size alongwith sand and connected items and replacement with new filter media of gravel of various sizes and sand including filler by taking out (unloading) after opening the top and side manhole covers by removing nuts, bolts & washers, de-scaling & prepairing the surfaces for painting the complete IRON REMOVING PLANTthoroghly both inside & outside wall surfaces by using wire brush, sand papers etc and applying one coat of paint as per the existing specifications both internally and externally and replacement of faulty pressure gauges, gate valves, butterfly valves of any size, piping network, butterfly valves etc as directed, alum & soda pots etc with proper care and re-fixing of manhole covers by tightning nuts, bolts, washers & new rubber packing sheets to the shape and size as per site requirement including removing the waste materials from water supply installations minimum50m away, spreading, levelling, rinsing, testing and back wash the IRP at least thrice before water supply to the users complete in all respect all as specified and directed by the Engr-in-Charge.Note :(i) Cost of minor spares i.e. cotton waste, nuts, bolts, washers, rubber packing sheet for re-fixing of manhole covers etc deemed to be included in the quoted rates.(ii) Cost of cleaning, brushing, de-scaling with sand paper and painting internally & externally incl piping network etc deemed to be included in the quoted rates.(iii) Cost of major spares/items i.e. new Filter media pebbles & sand, pressure gauges, alum / soda pots, butterfly valves, gate valves of any size will be measured and paid seperataly under relevant item of BoQ as supply only) |
| 52 | All as per Serial item No. 51 above but for 10000 GPH bore well capacity complete and ditto |
| 53 | Supply only new filter media of gravel of size 3/4\"x1/2\", free from any foreign materials and washed with clean water before filling complete all as specified and directed by the Engr-in-Charge. |
| 54 | Supply only new filter media of gravel of size 1/2\" x 1/4\", free from any foreign materials and washed with clean water before filling complete all as specified and directed by the Engr-in-Charge. |
| 55 | Supply only new filter media of gravel of size 1/4\" x 1/8\", free from any foreign materials and washed with clean water before filling complete all as specified and directed by the Engr-in-Charge. |
| 56 | Supply only new filter media of fine agregate (sand) (16x32mm mesh) , free from any foreign materials and washed with clean water before filling complete all as specified and directed by the Engr-in-Charge. |
| 57 | Supply only PVC strainer nozzle for under bed plate, double nut type as per the existing specifications complete all as specified and directed |
| 58 | Supply only water pressure gauge diaphram type range 0-7 Kg/Sq cm 100 mm dia complete all as directed by Engineer-in-Charge. |
| 59 | Supply only 50mm bore, cast iron butterfly valve, both ends flanged type, PN 1.6 including necessary rubber gasket etc as per the existing specifications complete all as directed |
| 60 | Supply only 80mm bore, cast iron butterfly valve, both ends flanged type, PN 1.6 including necessary rubber gasket etc as per the existing specifications complete all as directed |
| 61 | Supply only 100mm bore, cast iron butterfly valve, both ends flanged type, PN 1.6 including necessary rubber gasket etc as per the existing specifications complete all as directed |
| 62 | Supply, install, testing & commissioning electromagnetic and diaphragm type chemical dosing pump, 6 Ltrs/Hr @ 4kg back pressure capacity with high pressure and adjustable precision fluid delivery from 0 to 100 PSI including all accessories as per manufacturer\"s instructions and taking out old unserviceable pump by dismantling electrical & mechanical connection and removing from site of work complete in all respect all as specified and directed. (Make : RMCO, Model No. RC-11 (Digital) or other equivalent as per list of manufacturer) |
| 63 | S & F in repair PVC pipe 10mm dia suitable for connection of chemical dosing pump to filtered water supply pumping/riser water line complete all as per the existing make or specifications and as directed. |
| 64 | S & F in repair PVC foot valve assembly suitable for PVC pipe 10mm dia complete all as per the existing make or specifications and as directed |
| 65 | S & F in repair integral avation light comprising of aluminium housing with polycorbonate enclosurewith LED lamps fixed in position on over head tank minimum height 30 meter staging with provisiong of 1.5Sq.mm 3 core multi stranded copper conductor cable passing through pvc conduit pipe with all fixing accessories complete all as specified. (Make : BAJAJ or equivalent or equivalent as per list of manufacturer\"s) |
| 66 | M & L for cleaning/carrying out compression of existing borewells, bore hole dia upto 250mm of any type (MS/PVC Pipe) casing pipe, depth upto 350 feet by using compressed air with adequate pressure after disconnecting all electrical & mechanical connections, taking out the submersible motor pump set of 7.5HP to 20HP, 3 phase, 415V, AC alongwith CI/GI tubings of size upto 80mm bore dia and their fittings, keeping submersible motor pump set and GI tubings, GI fittings, electrical cable aside in safe custody to re-use for lowering the submersible motor pump set after necessary borewell compression and yield testing complete in all respect. Compression of borewell should be carried out continuously as directed but not less than 04 hours. All requisite T&P, diesel for DG set / vehicle for carrying out air compressor & DG set, compressed air pipes, making necessary arrangment of water upto nearest drain or other requisite arrangements etc as required to complete the job work and all these should be arraged by contractor at his own expenditure. Making electrical and mechanical connections for lowering of submersible motor pump set alongwith water pipes and carry out necessary testing of submersible motor set after lowering complete in all respect to the satisfaction of Engr-in-Charge and also submit yield testing report for records.(Note : (a) Cost of all requisite T&P and material required for taking out submersible motor pumpset, compression & yield testing of borewell and lowering of submersible motor pumpset deemed to be included in the quoated rates and no any extra amount will be paid. (b) Cost of minor spares i.e. cotton waste, GI fittings (socket, union, elbow, flanges, nuts, bolts, washers etc), yarn & sealent for jointing GI tubings, rubber packing / gasket sheet required for connecting and lowering of submersible motor pump set deemed to be included in the quoated rates.) |
| 67 | S & F in repair water level indicator for over head tanksincluding all ball, rope, pulley andlevel indicator as per site requirementcomplete all as specified and directed. |
| 68 | S & F in repair auxilary contactorMNX 18 suitable for 7.5/5 HP induction motors complete all as specified and directed. (Make: L & T or equivalent of make as per List of manufacturer\"s) |
| 69 | S & F in repair auxilary contactor auxilary contactorMCX 13 with MNX-A1 complete all as specified and directed. (Make: L & T or equivalent of make as per List of manufacturer\"s) |
| 70 | M & L for dismantling & removing defective electric motor 3 HP capacity, 3 Phase,415 Volt, 50 Hz by disconnecting all electrical, water supply tubings and mechanical connections from its foundation and shifting to AGE E/M Store yard, opening & checking in Engr-in-Charge to ascertain the quantum of defects and repair works involves, cleaning motor as required, transporting defective motor to nearest workshop for necessary repairing & rewinding, Taking out burnt copper windings, cleaning of slots of the motor, rotor, re-winding motor with super enamalled copper insulated wire of suitable gauge and weight (as per existing) including necessary Insulation materials, varnishing, heating, complete, re-assembling the motor and testing for smooth functioning after necessay repairing, re-winding, transporting motor to worksite, re-installed at site and providing all connections and testing, complete all as specified and as directed. (Note: Spare parts, Ball bearing etc as required shall be measured and paid seperately as supply only under relevant item) |
| 71 | M & L for dismantling & removing defective electric motor 5 HP capacity, 3 Phase,415 Volt, 50 Hz by disconnecting all electrical, water supply tubings and mechanical connections from its foundation and shifting to AGE E/M Store yard, opening & checking in Engr-in-Charge to ascertain the quantum of defects and repair works involves, cleaning motor as required, transporting defective motor to nearest workshop for necessary repairing & rewinding, Taking out burnt copper windings, cleaning of slots of the motor, rotor, re-winding motor with super enamalled copper insulated wire of suitable gauge and weight (as per existing) including necessary Insulation materials, varnishing, heating, complete, re-assembling the motor and testing for smooth functioning after necessay repairing, re-winding, transporting motor to worksite, re-installed at site and providing all connections and testing, complete all as specified and as directed. (Note: Spare parts, Ball bearing etc as required shall be measured and paid seperately as supply only under relevant item) |
| 72 | M & L for lifting of Submersible Pump and Motor assembly 7.5 HP capacity alongwith complete Column pipes. Submersible cable, safety rope etc from the existing Borewell by emplying chain pulley block etc, dismantling column pipes by opeining nuts, bolts, pump & motor etc, seggregating & stacking of serviceable column pipes & other materials and keep in safe custody for re-use and carry out necesssary repair works under the respective items here-in-below and Re-Lowering down of Submersible Pump and Motor assembly upto 7.5 HP capacity after repair alongwith complete Column pipes, Submersible cable, safety rope in the existing Borewell by emplying chain pulley block etc, and T & P, testing on completion complete all as specified and diretced. |
| 73 | M & L for removing submersible pump and motor assembly 7.5 HP capapcity to AGE E/M Store yard, Opening/dismantling and checking in presence of Engr-in-Charge to ascertain the quantum of defects and repair works involves, cleaning of cover and parts as required, transportation of defective submersible pump and motor assembly to nearest workshop for repairs, repairing and replacement of unserviceable parts and re-assembling submersible pump and motor assembly after repair and servicing and transporting repaired submersible pump motor assembly back to work site complete all as specified and diretced.(Note: (a) Spare Parts required to be replace will be measured and paid as \"Supply only\" under relevent items and the cost of labour element involved for replacement of parts shall demmed to be included in the unit quoted rate.(b) Any Minor repairs involved to make the submersible pump and motor assembly functional, even if not notified by the Engr-in-Charge, the same shall be carry out by the contractor without any extra cost to the Department.(c) The cost of minor spares parts/ items viz, nuts, bolts, washer, gasket etc shall deemed to be included in the unit quoted rate.(d) Rewinding of submersible motor, herever involves will be measured and paid seperately under relevent item) |
| 74 | M & L for dismantling of Submersible Motor 7.5 HP capacity, taking out burnt windings, cleaning of slots of the motor and Rewinding the same with water proof super enamelled copper insulated wire of suitable guage and weight as per the existing one including necessary insulation materials, varnishing, heating, reassembling the same and testing for smooth functioning after rewinding complete all as specified and directed by the Engr-in-Charge. |
| 75 | M & L for lifting of Submersible Pump and Motor assembly 12.5/15 HP capacity alongwith complete Column pipes. Submersible cable, safety rope etc from the existing Borewell by emplying chain pulley block etc, dismantling column pipes by opeining nuts, bolts, pump & motor etc, seggregating & stacking of serviceable column pipes & other materials and keep in safe custody for re-use and carry out necesssary repair works under the respective items here-in-below and Re-Lowering down of Submersible Pump and Motor assembly upto 12.5/15 HP capacity after repair alongwith complete Column pipes, Submersible cable, safety rope in the existing Borewell by emplying chain pulley block etc, and T & P, testing on completion complete all as specified and diretced. |
| 76 | M & L for removing submersible pump and motor assembly 12.5/15 HP capapcity to AGE E/M Store yard, Opening/dismantling and checking in presence of Engr-in-Charge to ascertain the quantum of defects and repair works involves, cleaning of cover and parts as required, transportation of defective submersible pump and motor assembly to nearest workshop for repairs, repairing and replacement of unserviceable parts and re-assembling submersible pump and motor assembly after repair and servicing and transporting repaired submersible pump motor assembly back to work site complete all as specified and diretced.(Note: (a) Spare Parts required to be replace will be measured and paid as \"Supply only\" under relevent items and the cost of labour element involved for replacement of parts shall demmed to be included in the unit quoted rate.(b) Any Minor repairs involved to make the submersible pump and motor assembly functional, even if not notified by the Engr-in-Charge, the same shall be carry out by the contractor without any extra cost to the Department.(c) The cost of minor spares parts/ items viz, nuts, bolts, washer, gasket etc shall deemed to be included in the unit quoted rate.(d) Rewinding of submersible motor, herever involves will be measured and paid seperately under relevent item) |
| 77 | M & L for dismantling of Submersible Motor 12.5/15 HP capacity, taking out burnt windings, cleaning of slots of the motor and Rewinding the same with water proof super enamelled copper insulated wire of suitable guage and weight as per the existing one including necessary insulation materials, varnishing, heating, reassembling the same and testing for smooth functioning after rewinding complete all as specified and directed by the Engr-in-Charge. |
| 78 | M & L for lifting of Submersible Pump and Motor assembly 20 HP capacity alongwith complete Column pipes. Submersible cable, safety rope etc from the existing Borewell by emplying chain pulley block etc, dismantling column pipes by opeining nuts, bolts, pump & motor etc, seggregating & stacking of serviceable column pipes & other materials and keep in safe custody for re-use and carry out necesssary repair works under the respective items here-in-below and Re-Lowering down of Submersible Pump and Motor assembly upto 20 HP capacity after repair alongwith complete Column pipes, Submersible cable, safety rope in the existing Borewell by emplying chain pulley block etc, and T & P, testing on completion complete all as specified and diretced. |
| 79 | M & L for removing submersible pump and motor assembly 20 HP capapcity to AGE E/M Store yard, Opening/dismantling and checking in presence of Engr-in-Charge to ascertain the quantum of defects and repair works involves, cleaning of cover and parts as required, transportation of defective submersible pump and motor assembly to nearest workshop for repairs, repairing and replacement of unserviceable parts and re-assembling submersible pump and motor assembly after repair and servicing and transporting repaired submersible pump motor assembly back to work site complete all as specified and diretced.(Note: (a) Spare Parts required to be replace will be measured and paid as \"Supply only\" under relevent items and the cost of labour element involved for replacement of parts shall demmed to be included in the unit quoted rate.(b) Any Minor repairs involved to make the submersible pump and motor assembly functional, even if not notified by the Engr-in-Charge, the same shall be carry out by the contractor without any extra cost to the Department.(c) The cost of minor spares parts/ items viz, nuts, bolts, washer, gasket etc shall deemed to be included in the unit quoted rate.(d) Rewinding of submersible motor, herever involves will be measured and paid seperately under relevent item) |
| 80 | M & L for dismantling of Submersible Motor 120 HP capacity, taking out burnt windings, cleaning of slots of the motor and Rewinding the same with water proof super enamelled copper insulated wire of suitable guage and weight as per the existing one including necessary insulation materials, varnishing, heating, reassembling the same and testing for smooth functioning after rewinding complete all as specified and directed by the Engr-in-Charge. |
| 81 | Supply only PVC insulated, sheathed, flat stranded copper conductor of 6 Sqmm, 3 core, 1100 Volts Grade conforming to IS:694 water proof submersible cable cable complete all as specified and directed. |
| 82 | S & F in repair DOL starter, 7.5 HP, 415 Volts, 50 Hz with outgoing and incoming cable connections and testing on full load complete all as specified and directed.(Make: Havell\"s Cat No. IHHDOLMA*E or equivelant as per list of manufacturer) |
| 83 | S & F in repair Fully automatic star delta starter, 12.5 HP, 415 Volts, 50 Hz with outgoing and incoming cable connections and testing on full load complete all as specified and directed.(Make: Havell\"s Cat No. IHHASDTA or equivelant as per list of manufacturer) |
| 84 | S & F in repairs MCB TP, 63 Amps, 415 Volts, 10KA,C curve complete all as specified and as directed(Make :Havell\"s Cat part No. DHMGCTPF063 or equivelant of make as perList of manufacturer\"s) |
| 85 | S & F in repairs MCB TP, 32 Amps, 415 Volts, 10KA,C curve complete all as specified and as directed(Make :Havell\"s Cat part No. DHMGCTPF006-032 or equivelant of make as perList of manufacturer\"s) |
| 86 | S & F in repair Single phase preventorSDZ5, SPPR+ Timer, 360V complete all as specified and directed.(Make: L & T Cat No.XM818080000 or equivelant as per list of manufacturer) |
| 87 | S & F in repair Fully automatic star delta starter with NHD contactor, 5 to 10 HP HP, 415 Volts, 50 Hz, 3 phase with outgoing and incoming cable connections and testing on full load complete all as specified and directed.(Make: Havell\"s Cat No. IHSASAH1*A or equivelant as per list of manufacturer) |
| 88 | S & F in repair Fully automatic star delta starter with NHD contactor, 20 HP, 415 Volts, 50 Hz, 3 phase with outgoing and incoming cable connections and testing on full load complete all as specified and directed.(Make: Havell\"s Cat No. IHSASAN1*A or equivelant as per list of manufacturer) |
| 89 | S & F in repair DOL starter with NHD contactor, 2 to 3 HP, 415 Volts, 50 Hz, 3 phase with outgoing and incoming cable connections and testing on full load complete all as specified and directed.(Make: Havell\"s Cat No. IHSDOAH1*B or equivelant as per list of manufacturer) |
| 90 | S & F in repairon load Change over switch, general purpose with side handle, current rating 63Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. (Make: L & T Cat No. CO10630OOOO or equivelant approved make as per list of manufacturer) |
| 91 | S & F in repair on load Change over switch, general purpose with side handle, current rating 100Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. (Make: L & T Cat No. CO11000OOOO or equivelant approved make as per list of manufacturer) |
| 92 | S & F in repair LED ammeter, 0-50 Amps of dial size 96x96mm flush mounting with accuracy class 1.0, single phase, complete all as specified and directed. |
| 93 | S & F in repair LED voltmeter, 0-500 Volts of dial size 96x96mm flush mounting with accuracy class 1.0, single phase, complete all as specified and directed. |
| 94 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
| 95 | M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts,check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
| 96 | M & L for routine maintenance of DG Sets from 20KVA to 30KVA rating capacity, 3phase, 415V, 50Hz, AC supply, 1500RPM, air cooled of Kirloskar or any make and model consisting of normal repairs with periodical routine/preventive maintenance and testing of all the DG sets components / parts i.e. Engine, Alternator, AMF panel, AVR, primary & secondary filters, battery terminals, earthing, self starter, electrical cable lugs, indicators, ON/OFF switches, DG set running display board including control wiring, contactors, phase connectors, CT ratio, cylinder control fuzes upto 10Amps, FIP, radiators, hoses with clamps etc for tunning up & smooth functioning of DG sets including all consumables items like cotton, waste cloth, kerosene oil, \"O\" rings, CTC for cleaning, grease etc.. Maint will be carried out as and when ordered by Engineer-in-Chagre only and maintenance shedule also cover the followings scope :-(a) Replacement of all Filters, Lubricating Oil.(b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings(c) Carry out necessary Tappet Clearance, if required.(d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins.(e) Check functioning of Changing Alternator.(f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required.(g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required.(h) The Governor shall be Checked and Tuned for Proper Functioning.(j) Check for Leaks if any and shall be rectified.(k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues.(NOTE : (a) Replacement of Consumable Items such as Distilled Water, Lube Oil, Grease etc are deemed to be included in the unit quoted rate. (b) All Other Spare Parts (Quantitites mentioned under supply only items here-in-after are Provisional only) and will be Measured & Paid seperately as \"Supply only\" under appropriate Items. Labour element for the same shall deemed to be included in the unite quoted rate) |
| 97 | All as per serial item No. 96 above but for 50/62.5 KVA DG set complete ditto |
| 98 | All as per serial item No. 96 above but for 125 KVA DG set complete ditto |
| 99 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 20/30 KVA complete all as specified and as directed. |
| 100 | Supply only AVR (as per existing/ as approved) suitable for DG Set 20/30 KVA complete all as specified and as directed. |
| 101 | Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 20/30 KVAcomplete all as specified and as directed. |
| 102 | Supply only Bearing for cooling fan and fan belt (as per existing/ as approved) suitable for DG Set 20/30 KVAcomplete all as specified and as directed. |
| 103 | Supply only Cooling fan (as per existing/ as approved) suitable for DG Set 20/30 KVAcomplete all as specified and as directed. |
| 104 | Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 20 to 30 KVA complete all as specified and as directed. |
| 105 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 20/30 KVA complete all as specified and as directed. |
| 106 | Supply only PCB Card (as per existing/ as approved) suitable for DG Set 20 to 30 KVA complete all as specified and as directed. |
| 107 | Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 20 to 30 KVA complete all as specified and as directed. |
| 108 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 20/30 KVA complete all as specified and as directed. |
| 109 | Supply only V Belt (as per existing/ as approved) suitable for DG Set 20 to 30 KVA complete all as specified and as directed. |
| 110 | Supply only Governor assembly (as per existing/ as approved) suitable for DG Set 20 to 30 KVA complete all as specified and as directed. |
| 111 | Supply only Starter Field Coil (as per existing/ as approved) suitable for DG Set 20 to 30 KVA complete all as specified and as directed. |
| 112 | Supply only Piston assembly (as per existing/ as approved) suitable for DG Set 20 to 30 KVA complete all as specified and as directed. |
| 113 | Supply only Cylinder liner (as per existing/ as approved) suitable for DG Set 20 to 30 KVA complete all as specified and as directed. |
| 114 | Supply only Stainer switch (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed. |
| 115 | Supply only Relay (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed. |
| 116 | Supply only Crank shaft assembly (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed. |
| 117 | Supply only Main Bearing Set (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed. |
| 118 | Supply only CR Bearing Set (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed. |
| 119 | Supply only Idle Gear & Shaft (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed. |
| 120 | Supply only Gasket Set (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed. |
| 121 | Supply only Nozzle Pipe Set (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed. |
| 122 | Supply only Radiator Assembly (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed. |
| 123 | Supply only Piston Ring Set (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed. |
| 124 | Supply only Fuel Pump (as per existing/ as approved) suitable for DG Set 30 KVA complete all as specified and as directed. |
| 125 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 126 | Supply only AVR (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 127 | Supply only Bearing for cooling fan and fan belt (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 128 | Supply only Controler Model No. KG934(as per existing/ as approved) suitable for DG Set 50/62.5 KVAcomplete all as specified and as directed. |
| 129 | Supply only Cooling fan(as per existing/ as approved) suitable for DG Set 50/62.5 KVAcomplete all as specified and as directed. |
| 130 | Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 131 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 132 | Supply only Fuel pipe (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 133 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 134 | Supply only V Belt (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 135 | Supply only Stainer switch (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 136 | Supply only Relay (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 137 | Supply only Governor assembly (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 138 | Supply only Starter Field Coil (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 139 | Supply only Piston assembly (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 140 | Supply only Cylinder liner (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 141 | Supply only Main Bearing Set (as per existing/ as approved) suitable for DG Set 50/62.5 KVA complete all as specified and as directed. |
| 142 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 143 | Supply only AVR (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 144 | Supply only Bearing for cooling fan and fan belt (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 145 | Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 125 KVAcomplete all as specified and as directed. |
| 146 | Supply only Cooling fan(as per existing/ as approved) suitable for DG Set 125 KVAcomplete all as specified and as directed. |
| 147 | Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 148 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 149 | Supply only Fuel pipe (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 150 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 151 | Supply only V Belt (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 152 | Supply only Stainer switch (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 153 | Supply only Relay (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 154 | Supply only Governor assembly (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 155 | Supply only Starter Field Coil (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 156 | Supply only Piston assembly (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 157 | Supply only Cylinder liner (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 158 | Supply only Main Bearing Set (as per existing/ as approved) suitable for DG Set 125 KVA complete all as specified and as directed. |
| 159 | Supply only PCB Card (as per existing/ as approved) suitable for DG Set 50 to 125 KVA complete all as specified and as directed. |
| 160 | Dismantling the alternator of 20 to 125 KVA DG Set from its position after disconnecting all electric connections with help of chain pulley, removing the bearing with the help of bearing puller and shifting the alternator to authorised workshop for repair and servicing complete checking of connections, terminals, lugs, tightening of connections, replacement of bushes, making good copper coil winding if burnt complete and refixing again its own position and proper alingment complete all directed by the Engr-in-Charge. (Note: (a) Winding materials of copper coil with insulation materials shall be measured and paid seperately as Supply only. Labour element for re-winding shall deemed to be included in the unit quoted rate (b) Minor spare requireded for smooth functioning of alternator shall be provided by the contractor without any extra cost to the Govt) |
| 161 | Supply only Super Enamel Copper Winding Wires with Proper Guage Rewinding of Alternator/Armature etc Coils of any Capacity with Double Paper covering, conforming to IS:7404 (Part-I) : 1991 (as per existing Size, Turns and Insulation Class) including All Insulation Materials, Gasket, etc., suitable for 415 Volt Alternator complete all as specified and as directed. |
| 162 | S & F in repair heavy duty synthetic insulation mat of size 2mx1m/2.0mm thick conforming to IS:15652-2006 suitable for 1100 Volts, ISI marked complete all specification and directed. |
| 163 | Disconnecting & Dismounting of Self Starter, 12 Volts from the Engine of DG Set 20 KVA to 30 KVA, Transporting to nearest Authorised Workshop for Repairing, Replacement of Unservicable Parts, Servicing Complete, Transporting the same from Workshop to Site of Work and Re-fixing with DG Set, Testing, complete all as specified and as directed. (Note: Minor spare requireded for smooth functioning of starter shall be provided by the contractor without any extra cost to the Govt) |
| 164 | Disconnecting & Dismounting of Self Starter, 12 Volts from the Engine of DG Set 50 KVA to 125 KVA, Transporting to nearest Authorised Workshop for Repairing, Replacement of Unservicable Parts, Servicing Complete, Transporting the same from Workshop to Site of Work and Re-fixing with DG Set, Testing, complete all as specified and as directed. (Note: Minor spare requireded for smooth functioning of starter shall be provided by the contractor without any extra cost to the Govt) |
| 165 | S & F in repair Battery 12 Volt, 120 AH (as approved) and Providing all Electrical Connection complete all as specified and as directed.(MAKE : EXIDE XPRESS/LUMINOUS/AMRON) |
| 166 | S & F in repair Oil Safety Control (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up complete all as specified and as directed. |
| 167 | S & F in repair Solenoid Switch Assembly (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up complete all as specified and as directed. |
| 168 | S & F in repair Water Safety Control (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up complete all as specified and as directed. |
| 169 | S & F in repair Water Temperature Gauge (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting upcomplete all as specified and as directed. |
| 170 | M & L for Cleaning of Radiator of any Capacity after Opening all Nuts, Bolts, etc. by dismounting, Re-mounting after Cleaning with Chemical and Tightening of Nuts, Bolts, etc. including Straightening of Radiator Fins with suitable Tools, complete all as specified and as directed. |
| 171 | M & L for Repairing & Cleaning of Diesel Tank with suitable Materials after disconnecting Fuel Line, Opening of all Nuts, Bolts, etc., Re-fixing the same after satisfactory Repairing including necessary Welding (if required), etc., complete all as specified and as directed. |
| 172 | M & L for Disconnecting all Electrical Cable Connection from the Dynamo Assembly and Taking down the Dynamo Assembly for Carry out Repairs and Complete Overhauling the System including Replacing the Unserviceable Parts like Carbon Bushes, Bearings, Armature, Burnt out coils, etc., Re-assambling & Re-fixing the Dynamo Assembly to Original Position and re-connecting all Electrical Cable Connections & Testing for DG Set 20 KVA to 50 KVA of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed. |
| 173 | S & F in repair Battery Terminal of Copper/Brass (as per existing/ as approved) and connected complete all as specified and as directed. |
| 174 | S & F in repair Digital Battery Charger of 100 to 150 AH suitable for Charging Battery 12 Volt and Providing All Electrical Connections as required for BatteryCharging and Removing old Battery Charger to AGE E/M Store Yard and deposited complete all as specified and as directed. |
| 175 | Supply & Filling Coolant for Radiators as approved complete all as specified and as directed.(MAKE : KIRLOSKAR or equivalent Make as approved by GE) |
| 176 | Supply & Filling Engine Oil 20 W/ 40 Grade as approved, complete all as specified and as directed.(MAKE : CASTROL CRB PLUS or equivalent Make as approved by GE) |
| 177 | S & F in repairMCCB 415 Volt, 36 KA, 4 Pole, 160 Amps Capacity complete all as specified and as directed. |
| 178 | S & F in repairMCCB 415 Volt, 36 KA, 4 Pole, 200 Amps Capacity complete all as specified and as directed. |
| 179 | S & F in repairMCCB 415 Volt,25 KA,3 Pole,100 Amps Capacity complete all as specified and as directed. |
| 180 | S & F in repair contactor, 4 pole, AC supply for 11 KW/15 HP submersible pump complete all as specified and as directed. |
| 181 | S & F in repair contactor, 4 pole, AC supply for 7.5 KW/10 HP submersible pump complete all as specified and as directed. |
| 182 | S & F in repair indicator lamp, LED type of colour red, blue and yellow complete all as specified and directed. |
| 183 | S & F in repair Thermal over laod relay, 7 to 10 Amps, directly operated complete all as specified anddirected. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy