}

Tender For External Electrification Of Development Of Msme Cluster Park In District Mau - Sub Head -I Transformer 2 Sub Head -I Transformer 3 5 Mva 33/11 Kv Power Transformer Three Phase Crgo Cooper Wound As Per Uppcl Stock 4 10 Mva 33/11 Kv Power T, Mau-Uttar Pradesh

Uttar Pradesh Small Industries Corporation Limited has published Tender For External Electrification Of Development Of Msme Cluster Park In District Mau - Sub Head -I Transformer 2 Sub Head -I Transformer 3 5 Mva 33/11 Kv Power Transformer Three Phase Crgo Cooper Wound As Per Uppcl Stock 4 10 Mva 33/11 Kv Power T. Submission Date for this Tender is 25-06-2025. Gardening Tenders in Mau Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

49630659
Tender For External Electrification Of Development Of Msme Cluster Park In District Mau - Sub Head -I Transformer 2 Sub Head -I Transformer 3 5 Mva 33/11 Kv Power Transformer Three Phase Crgo Cooper Wound As Per Uppcl Stock 4 10 Mva 33/11 Kv Power T
Tender
Indian
Uttar Pradesh
Mau
25-06-2025

Tender Documents

Tender Details

External Electrification Of Development Of Msme Cluster Park In District Mau - SUB HEAD -I Transformer 2 SUB HEAD -I Transformer 3 5 MVA 33/11 KV Power Transformer Three phase CRGO cooper wound as per UPPCL Stock 4 10 MVA 33/11 KV Power Transformer Three phase CRGO cooper wound as per UPPCL Stock 5 LT Transformer 6 Supply, Installation, testing and commissioning of 250 KVA. 11/0.433 KV, 3Phase, 50Hz, Dyn 11, Oil type, ( UPPCL approved make) copper wound transformer with Off load tap changing arrangement on HV side in steps of +/- 2.50%, +/- 5% , having cable end boxes on HV sideand 500 Amp. bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to Part 5) & as per specification attached complete in all respects as required at site. 7 Note:Foundation work for transformer is not included in Electrical works it will come on Civil work. 8 11 KV DOUBLE POLE STRUCTURE 9 Supply, erection, testing and commissioning of 2 pole structure for providing 1 No. 11KV,200A GOS in accordance with IE rules, & local authority specification and drawings and comprising of the following. 10 a. 2 Nos. 11 mtr. long MS STEEL poles complete with, pole excavation, MS STEEL foundation, and back filling complete MS steel channel/angle iron etc. 11 b. 1 Set of cross arms, branching, clamps and painting complete with GI nut, bolts & washers as required (for GO & DO), LA connection. 12 c .1 set 11KV Insulator complete with spindles & hardware complete as required. 13 d .1 No. 11KV 400A TP Gang operated Air break switches complete with 25mm dia GI pipe operating machanism, handle & locking arrangement. 14 e. 1 set of 3 nos.11KV single pole drop out fuse complete with barrel fuses, and mounting arrangement. 15 f. 1 set (3 nos.) 11KV lightning arrestor and connecting to all phases. 16 g. 1 No. 150 mm dia GI pipe class B (for XLPE cable protection) as required. 17 h. 2 Set 50mm dia 3m long GI pipe earting with 25 x 6 mm GI earth strip complete as required (for GO & DO & LA) 18 i 1 nos. 11KV HT danger boards and 2 set of anticlimbing devices. 19 11 KV Double Pole Structure 20 11KV Disc insulators 45KN T & C Type 21 Disc Fitting (T&C Type) 22 11KV 8 panel board 24V DC operated with 1 No. I/C panel 23 11KV 8 panel board 24V DC operated with 6 No. O/G Panel and 1 No. Capcitor Control Panel 24 11KV Buscoupler 25 11KV Lightening Arrestor Sub-Stn type 10KA (heavy duty) 26 11KV NCTs 600/5A 27 11 kV automatically Switched Capacitorbank 1.8 MVAR, (with isolator, structure and all allied material ) 28 Support for11 KV overheaa line as per technical specification, approvea drawings and scot of work 29 STP-11M IS 410 SP-55 30 Pre-fabricated Hot dip Galvanised steel items liLeV cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, triuisiormer mounting structure etc made of MS Channels (l00x50x6mm),MS angle (65x65x6mm),MS dats (65x8mm) of given sizes forover head structures as per technical specification, approved drawings and scope of work. 31 11 KV Line Pole Top Bracket (8 No.) - 3.625 Kg. each 32 11KV Line V Cross Arm (8No.) - 15.94 kg. each 33 M.S. Channel (X-arm) 100x50x6mm-2200 mm for H-Pole (2 No.) - 17.38 Kg. each 34 M.S. Angle Iron 50x50x6mm-2400 mm for earthing (1 No.) - 10.8 Kg. each 35 M.S. Channel 100x50x6mm-1600 mm for earthing (8 No.) - 12.64 Kg. each 36 M.S. Angle 50x50x6mm-2860 mm for Bracing H-Pole (2 No.) - 12.87 Kg. each 37 Half Clamp (24 No.) - 1.47 Kg. 38 Full Clamp (10 No.) - 2.325 Kg. 39 MS Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work. 40 GI Nuts, Bolts & Washer off all required sizes - 10 Kg 41 Hot dip Galvanised Eye Screw Bolt 9x5/8 (19 No.) - 0.483 Kg. 42 Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (2 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work. 43 Insulator and hardware as per technical specification, approved drawings and scope of work. 44 11 KV polymeric Disc insulator 45 KN along with suitable hardware fittings 45 11 KV Polymeric Pin Insulators with GI PIN 46 ACSR Conductor 0.2 sq in(Panther) 47 C Wedge connectors for ACSR conductor 0.2 sq. inch. Panther (Nom. Al area 200 mm2 ) 48 11KV Single core XLPE cable 300mm2for Incoming Feeder 49 S/C 300 mm Sq.cable Termination Kit indoor 50 S/C 300 mm Sq.cable Termination Kit outdoor 51 11KV 3 core XLPE cable 185mm2 for O/G Feeders 52 11KV 3 core XLPE cable 300 mm2 for capacitor bank 53 11KV 3 core XLPE cable 70mm2 for S/Stn T/F. 54 3/Cx185MM Sq. outdoor Heat shrinkable Termination Kit for O/G 55 3/Cx185MM Sq. indoor Heat shrinkable cable box for I/G 56 3/Cx300 MM Sq. outdoor Heat shrinkable cable box for capacitor 57 3/Cx300 MM Sq. indoor Heat shrinkable cable box for capacitor 58 ACSR conauctor, Dog type (100 sq mm) 59 PG Clamps for 30/50/80/100 mm2 60 Barbed Wire 61 Danger Plate (Enamelled with Clamp) 62 Phase Indication Plates for each phase set of 3 (On H•Pole & d Pole) 63 ACSR conauctor, Dog type (100 sq mm) 64 PG Clamps for 30/50/80/100 mm2 65 Barbed Wire 66 Danger Plate (Enamelled with Clamp) 67 Phase Indication Plates for each phase set of 3 (On H•Pole & d Pole) 68 11 KV Cable boxes 3Cx50 mm2 Outdoor 69 PG Clamps for Panther conductor 70 MSNuts & Bolts off size 71 GI nuts & bolts off size 72 11 KV 400 Amps. GO Switch complete with handle, pipe & Sporting channel 73 11 KV LA type 9 KV Heavy Duty 74 SUB HEAD -V Earthing & Loop Earthing 75 Insulator and hardware as per technical specification, approved drawings and scope of work. 76 40 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, bentonite powder and other accessories complete 77 Spike Earthing 20mm solid Rod 78 Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing as required. 79 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 80 Earthing Rod Wt. 6.175 Kg 81 G.I. Pipe 40 mm dia 6 mtr. Long for earthing 82 Premier Insulating Mat - B Class as per IS 15652:2006 83 Earthing arrangement as per technical specificatons, approved drawings and scope of work. 84 40 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, bentonite powder and other accessories complete 85 Spike Earthing 20mm solid Rod 86 Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing as required. 87 Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. 88 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 89 Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosurewith cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ coke and salt as required. 90 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) 91 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm) 92 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required. 93 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. 94 Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing as required. 95 MS Channel galvanised of various size 96 MS Angle Iron galvanised50 X 50 X 6 mm 97 MS Flat galvanised 50 X 6 mm 98 MS Flat 75x8 MM for Earth mat in switch yard 99 100mm dia ISI marked GI Pipe with clamps 100 SUB HEAD -VI Cables 101 Supply & Stringing of LT AB Cable of 3x120+1x95+1x50sqmm 102 Supply & Laying of 4C X 25sqmm Al. Unarm. Cable 103 Supply & Installation of 3Phase Distribution Box 104 Supply & Installation of C- Type / Holding Clamp 105 Supply & Installtion of Eye hook Clamp 106 Supply & Installation of Nut & Bolts with washer 107 Supply & Installation of Suspension Clamp 108 Supply & Installation of Dead end Clamp 109 Supply & Installation of Piercing Connector 120Sqmm 110 Supply & Installation of Piercing Connector 95Sqmm 111 Supply & Installation of PG Clamp for ACSR Conductor 112 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules. 113 Providing, laying and fixing following dia RCC pipe NP2 class(light duty) in ground complete with RCC collars, jointing withcement mortar 1:2 (1 cement : 2 fine sand) including trenching(75 cm deep) and refilling etc as required. 114 300 mm dia 115 LT 3.5 core cable 95mm2 for LT Distribution Board 116 LT PVC cable 2C X 10 mm2 for yard light 117 un armoured Copper control cable 2C X 4mm2 RA-10 118 un armoured Copper control cable 2C X 6mm2 RA-11 119 un armoured Copper control cable 3C X 4mm2 RA-12 120 un armoured Copper control cable4C X 4mm2 RA-13 121 un armoured Copper control cable6C X 4mm2 RA-14 122 un armoured Copper control cable 7C X 2.5mm2 RA-15 123 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 124 Upto 35 sq. mm 125 SUB HEAD -VIIMain LT Panels 126 EXTERNAL LIGHT FEEEDER PILLAR 127 SITC of compartmentalised design, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated L.T panel complete as required with following incomming & outgoing as per detail below. 128 INCOMER 129 1 Nos. 400 AMP FP MCCB 130 BUSBARS 131 1 Nos. 500 Amp TPN busbars of aluminium alloy as per SLD. 132 OUTGOING 133 100 Amp.MCCB-3Nos. & 63 Amp.MCCB-2Nos. 134 INSTRUMENTS 135 1 Nos. 0 to 500 Volt digital voltmeter with Voltmeter Selector Switch & Protective 136 1 Sets breaker ON & OFF indicating lamp 137 1 Sets auto trip indicating lamp . 138 SUB HEAD -VIII Miscellaneous 139 1 No. Table, 4 No. Chair, Wall clock,Safety Charts, Safety Tool Kit & Medical Kit, earth stick-1 140 SUB HEAD -IX Safety Equipments 141 Fire Fighting/Safety eqpt for Control room 142 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 143 Supply and fixing of C02 type fire extinguisher 6.5 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 144 Fire Fighting/Safety eqpt for yard 145 Supply and fixing of fire extinguisher, ABC Type 9.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 146 CO2 type Fire extinguisher 22.5 Kgs 147 Fire Buckets (capacity) - 10 Ltrs 148 SUB HEAD -X External Lighting 149 Switch yard illumination system 150 Supply & fixing of 8mtr GI Octagonal Pole of approved make(top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with single arm bracket(1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 151 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and aboveProtection complete in all respect. CAT- AAA 152 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect. CAT- AAA 153 Supply & Installation of Single Arm Bracket for fitting of Street Light 154 LESS 5% FOR DEPARTMENT WORK

Key Value

Document Fees
INR 15425 /-
EMD
INR 653500.0 /-
Tender Value
INR 6.53 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail