Tender For Supply, installation, testing & commissioning Of Silent Dg Sets Of Different Capacity With Amf Panel Including Exhaust Pipe Line And Necessary Ei Work Against Different Important Buildings In The Premises Of Ipgmer - Sskm Hospital --------- S And D Of Dg Set For Upcoming Loads (Electrical Installation Work) Sl. No. Item Description 1 Dismantling of old damaged/derated LT cables/ defung feeder pillar box/panel/DB etc after necessary electrical testing & disconnectingthe all incoming & outgoing cables carefully and making temporary connection as per direction of the E.I.C. ( different locations of SSKM Hospital under jurisdiction of AE/SSKMHESD/P.W.Dte.). 2 Replacement of Panel :- 3 EXTENSION OF RAW PANEL AT SUB STATION - I : SITC offloor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C-1 1600A4P ACB - 1 No. and I/C-2 & B/C - 1250A 4P ACB - 2 Nos. incl Mechanical & Electrical Interlock, BBC 2500A 4 Bars- 1 Sets & Modification of existing bus bar,O/G : 800 A 4P MCCB --- 04 nos, 630 A 4P MCCB --- 04 nos [ Make : ABB / Schneider / Legrand / Siemens / LK]. 4 SUB PANEL AT SUB STATION - VI : SITCof floor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 1250A 4P ACB - 01 No. BBC 2000A 4 Bars- 1 Sets,O/G : 800 A 4P MCCB --- 03 nos, 630 A 4P MCCB --- 03 nos [ Make : ABB / Schneider / Legrand / Siemens / LK]. 5 RAW PANEL AT SUB STATION - II : SITCof floor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 1000A 4P ACB - 01 No. BBC 1600A 4 Bars- 01 Sets,O/G : 800 A 4P MCCB --- 02 nos, 630 A 4P MCCB ---- 04 Nos.,400A 4P MCCB --- 01 Nos. & 250A 4P MCCB - 01 Nos ] [ Make : ABB / Schneider / Legrand / Siemens / LK]. 6 SUB PANEL AT EASTERN & WESTERN SIDE OF UCM BUILDING :- SITCof floor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 630A 4P MCCB - 02 No. BBC 1000A 4 Bars- 01 Sets,O/G : 125A 4P MCCB --- 06 Nos. & 100A 4P MCCB - 04 Nos ] [ Make : ABB / Schneider / Legrand / Siemens / LK]. 7 SUB PANEL ATWESTERN SIDE (MCI) OF UCM BUILDING :-SITCof floor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 800A 4P MCCB - 02 No. BBC 1250A 4 Bars- 01 Sets,O/G : 400A 4P MCCB --- 02 Nos, 250A 4P MCCB --- 03 Nos. & 100-125A 4P MCCB - 04 Nos ] [ Make : ABB / Schneider / Legrand / Siemens / LK]. 8 SUB PANEL FOR PUMP & BSNL TOWER AT TRAUMA CARE CENTRE :-SITCof floor mounted Indoor type extensible cubical typeLT Panel,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 400A 4P MCCB - 02 No. BBC 640A 4 Bars- 01 Sets,O/G :100-125A 4P MCCB - 06 Nos &Fully Automatic Star Delta Stater - 04 Nos ] [ Make : ABB / Schneider / Legrand / Siemens / LK]. 9 PILLAR BOX AT ACADEMIC & EMERGENCY BUILDING :- SITCof floor mounted Indoor type cubical typeLTFeeder Pillar Box,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 800A 4P MCCB - 01 No. BBC 1280A 4 Bars- 01 Sets,O/G : 400A 4P MCCB --- 04 Nos, 200A 4P MCCB --- 02 Nos.][ Make : ABB / Schneider / Legrand / Siemens / LK]. 10 PILLAR BOX AT RONALD ROSS & CARDIOLOGY BUILDING :-SITCof floor mounted Indoor type cubical typeLTFeeder Pillar Box,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 800A 4P MCCB - 02 No. BBC 1280A 4 Bars- 01 Sets,O/G : 160A 4P MCCB --- 02 Nos, 125A 4P MCCB --- 04 Nos. & 100A 4P MCCB - 04 Nos ] [ Make : ABB / Schneider / Legrand / Siemens / LK]. 11 PILLAR BOXFOR PUMP IN FRONT OF RMO QUATER : SITCof floor mounted Indoor type cubical typeLTFeeder Pillar Box,fabricated by CPRI approved panel makeras per size,design & drawing to be approved by EIC and conforming to relevant ISwith latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[I/C 160A 4P MCCB - 01 No. BBC 250A 4 Bars- 01 Sets,O/G : 100/125A 4P MCCB --- 04 Nos. & Fully Automatic Star Delta Stater - 04 Nos ] [ Legrand / LK ] 12 Repairing of existing feeder Piller box by S&F of 3mm MS sheet including fabrication, S&F of door hinges and loocking arrangement. The Piller Box shouled be painted by approved paint after two coats of redoxide primar as per direction of EIC.(Back Side of Carmical Hostel). 13 Repairing of existing feeder Piller box if required includinge painting by approved paint after two coats of redoxide primar as per direction of EIC.(at different side). 14 S&F of following capacity 415V, 4-pole on-load changeover switch front hanle in SS enclosure with both side cable end box of suitable size on MS angle iron frame on wall (Make:-Legrand / LK/ Schneider). 15 415V, 4-pole, 630A 16 LT Cabling work: 17 S & Delivery of one number 1.1 KV GradeXLPE insulated andPVC sheathed aluminium conductor cable (Armoured) conforming to IS: 7098 / 1988 with its latest amendment of following size. [ Make Nicco / Fort Gloster /Havells/ Polycab/ RR Kable] 18 4 Core 300 Sq. mm² 19 4 Core 240 Sq. mm² 20 4 Core 185 Sq. mm² 21 4 Core 95 Sq. mm² 22 4 Core 70 Sq. mm² 23 4 Core 50 Sq. mm² 24 Layingof 1.1 KV GradeXLPE insulated andPVC sheathed aluminium conductor cable (Armoured)of following size in the existing Masonary trench as required andas per GS. 25 1 no. 4 Core 300 mm² 26 1 no. 4 Core 240 mm² 27 1 no. 4 Core 95 mm² 28 Laying of 1.1 KV GradeXLPE insulated andPVC sheathed aluminium conductor cable ( Armoured )of following sizeon existing cable tray/ supports as to GS. 29 1 no. 4 Core 300 mm² 30 1 no. 4 Core 240 mm² 31 1 no. 4 Core 185 mm² 32 1 no. 4 Core 95 mm² 33 1 no. 4 Core 70 mm² 34 1 no. 4 Core 50 mm² 35 Laying of 1.1 KV GradeXLPE insulated andPVC sheathed aluminium conductor cable ( Armoured )of following sizethrough RCC/Hume/G.I. pipe as to GS. 36 1 no. 4 Core 300 mm² 37 1 no. 4 Core 240 mm² 38 1 no. 4 Core 185 mm² 39 Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish 40 1 no. 4 Core 70 mm² 41 1 no. 4 Core 50 mm² 42 Straight through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC) as to GS for following: 43 3.5 / 4 Core 300 mm² Al cable 44 3.5 / 4 Core 240 mm² Al cable 45 3.5 / 4 Core 185 mm² Al cable 46 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 47 4 Core 300 mm 48 4 Core 240 mm² 49 4 Core 185 mm² 50 4 Core 95 mm² 51 4 Core 70 mm² 52 4 Core 50 mm² 53 Finishing the ends of single core . Ar / copper cable & S&F of copper socket , colour maching tape etc as to GS for following: 54 300 sq. mm² 55 240 sq. mm² 56 185 sq. mm² 57 95 sq. mm² 58 70 sq. mm² 59 50 sq. mm² 60 S&F of 80mm diamedium gauge GI Pipe ( ISI-Medium) for vertical cable protection with necessary fittings and jointing metarials as required. 61 S&F of 80 mm dia Heavy gauge PVC Pipe ( ISI-Medium) for horizontal cable protection with necessary fittings and jointing metarials as required. 62 S&F of special type angle Support for holding the cable by horizontally run. The above clamp made of 50 x 50 x 6 mm. angle iron with half round type MS clamp for rigidly holding the cable. The above clamp made of 40 x 3mm. thick flat iron patty incl. nuts, bolts & washers etc. The length of angle support as required for 4 Core 400/300/240/185/150 mm² XLPE, Ar./Al. cable. The total iron strucutre will be hot-dip Galvanized .The structure will be fixied on wall by proper grouting inside the wall and mending good the damagesas per direction of the EIC.[For 4 nos Cable run]. 63 S & Installation of Electro Zinc Galvanised Hot Dip Galvanised (105 / 400 mm outdoor type) Wiremesh cable Trayin accordance with standard BSEN 12329-2000 with all mounting accessories.Fire test certification should be published in accordance with the E30/E90 standard. Electrical continuity across a coupling should be demonstrated by means of a published test method and result.[MAKE: LEGRAND/eqv] 64 Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 65 300x50x1.25 mm (18SWG) with 25x25x6mm angle iron support. 66 400x50x1.25 mm (18SWG) with 35x35x6mm angle iron support. 67 Misc. Electrical works for different S/S & panel rooms: 68 S&F of Double Door Type 8 Way Vertical TPN PDB in S.S. enclosure with IP-42/43 protectionconsisting with 1 no160 A., 4-Pole MCCB (36KA) as incomer, 8 nos. 63A. TP MCB as outgoing. and both side cable end box complete with all connection with suitable size of Cu. wire with proper socketing on wall by suitable size of angle iron frame incl all accessories as per direction of E.I.C. (Make:-Legrand / LK/ Schneider) 69 S&F of Double Door Type 6 Way Vertical TPN PDB in S.S. enclosure with IP-42/43 protectionconsisting with 1 no125 A., 4-Pole MCCB (36KA) as incomer, 6 nos. 63A. TP MCB as outgoing. and both side cable end box complete with all connection with suitable size of Cu. wire with proper socketing on wall by suitable size of angle iron frame incl all accessories as per direction of E.I.C. (Make:-Legrand / ABB/ Schneider) 70 S&F of 240 V A.C. Exhaust Fan (EPC Electrical Pvt. Ltd. - Heavy Duty) incl. Cutting hole on wall with Nuts, Bolts, washers etc. on wall and mending good the damages to original finish as per direction of the EIC for following sizes:- 71 300 mm (12) sweep 1420 RPM 72 375 mm (15) sweep 970 RPM 73 S&F of L shape Cowl made of G.I sheet of suitable size having length 600mm with 4 nos 20x3mm MS flat support and S&F of wire mess at the ends of the said cowl with nuts, bolts etc as reqd. for following sizes exhaust fans:- 74 300 mm (12) sweep 75 375 mm (15) sweep 76 Marking of identification number/nomenclature of ACB/ MCCB/ Main switch/ VTPN/ HTPN / SPN DBs/ Starters etc after installation by suitable size identification plate or painted block letter matters as per direction of the EIC. 77 S&F of 240 V, 1200 mm Sweep, A.C. Ceiling Fan 5-star without Regulator & Down Rod incl. Canopy, Fan Blades etc. and engraving & Painting the Departmental Number (up to 14 digit) on Fan Body with black japan paint and interconnection complete in all respect. [Make: Crompton,/ Orient/Usha ] [for Sub-station rooms/ panel rooms] 78 S&F of 230 V., 18 (450mm) 4 (four) Blades Industrial type Air-Circulator Pedestal Fan complete with all accessories such as Regulator, Cord and 15 Amp. 3-pin Top(Make - E.P.C.Electrical Pvt. Ltd., Heavy Duty). 79 S&F of 90 Watt LED street light ( IP 66 ),Luminarie Efficacy-120 lm/W incl. 50,000 burning hrs @L70, aerodynamically designed with better thermal management with separate lamp housing with heatresistant toughened glass & control gear housing and potted driver provided with surge protection suitable for mounting on 50 mm dia (OD)existing Arm bracket [Make- Philip/ Osram/Wipro /crompton/ Bajaj) 80 S&F of 150 Watt LED street light ( IP 66 ),Luminarie Efficacy-120 lm/W incl. 50,000 burning hrs @L70, aerodynamically designed with better thermal management with separate lamp housing with heatresistant toughened glass & control gear housing and potted driver provided with surge protection suitable for mounting on 50 mm dia (OD)existing Arm bracket[Make- Philip/ Osram/Wipro /crompton/ Bajaj) 81 Supply & fixing of 300W , high power LED floodlight luminaire (IP 66/65), Luminarie Efficacy-120 lm/W incl. 50,000 burning hrs @L70 with built in-built Surge protection ( 4 KV) & External Surge protection (10 KV)and Operating Temperature 0°C to +50°C ( maintenance free system suitable for area lighting high mast with pressure die cast aluminium housing & toughened glass cover suitable for operation on 230V +/- 6%, 50 Hz A.C. supply, on High mast Pole including all accessories as per direction of EIC. [Make- Philip/ Osram/Wipro /crompton/ Bajaj) 82 Digital Multifunction meter for HV distribution & measurement of A, V, F, pf, KW, KVA, KVAR, KWH, Freq., Odd harmonics upto 15th with 2 DI & 2 DO and Class : 0.5, peak demand, battery backed up Real time clock, inbuilt dual Ethernet port and Data logging. The Meter will be fixed on fornt panel of existing Incomer & outgoing HT breakers at different Sub Station after disconnection & taken down the existing Ammeter including necessary cutting or blocking the cutout the existing meter posision by own tools & takels and wiring by suitable PVC copper wire (FRLS) with Termination and commissioning the MFM meter as per direction of EIC. The above meters will be communicated by the existing SCADA system of 33 KV Sub Station. (Make : Schneider/ Simens/ABB/L&K ). 83 Communicable Relay for existing Incomer & outgoing HT breakers at different Sub Station after disconnection & taken down the existing Relay including necessary cutting or blocking the cutout the existing Relay by own tools & takels and wiring by suitable PVC copper wire (FRLS) with Termination and commissioning the Relay. The specification of Reay same as above HT 4 panel mentioned in Separate GTP as per direction of EIC.The above Relays will be communicated by the existing SCADA system of 33 KV Sub Station. (Make : Schneider/ Simens/ABB/L&K ). 84 Dismantling the existing damaged LED indication lamps from front door of panels very carefully and refixing the new LED lamps (Red, Yellow, Blue, Green, Orange and White) including necessary connection as per direction of EIC. (Make :- Siemens / Schneider /ABB/ LK) 85 Voltage Range : 160 - 250 V AC. 86 a) RED 87 b) YELLOW 88 c) BLUE 89 d) GREEN 90 e) ORANGE 91 f) WHITE 92 Voltage Range : 24 V DC 93 g) RED 94 h) YELLOW 95 i) BLUE 96 j) GREEN 97 k) ORANGE 98 l) WHITE 99 Earthing work: 100 Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts (For Main LT Panel at SS-I & II) 101 Earthing with 50 mm dia GI pipe (TATA-M ) 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S &F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level incl Excavation of soil for installatio of earth electrode and filling & ramming (For Sub Panels & Pillar Box) 102 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with lockingrrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 103 Extra for treatment of soil by using salt & charcoal or coke for plate electrode 104 Excavation of soil for installation of Earth Electrode and filling& ramming. For Soft Soil 105 S&F of busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required 106 Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. 107 Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. 108 Necessary minor Civil/ Mechanical works : 109 Providing masonary cable trench extension after cutting all sorts of soil.The inside mearsurment of trench 600mm width x760 mm depth incl 250 mm thick brick work with 1st class brick cement mortorr (1:4) on both sides and bottom of the trench consisting with 100 mmthick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling 15mm thick (1:4) cement plaster to inside wall & 3mm thick neat cement furnish. 110 Providing detachable pre-cast RCC cover slabs (125 mm thick, 200 tonn load bearing capacity) over external portion of cable trench as per direction of EIC. 111 Supply, fabrication and placing/fixing MS checkered plate made of 6mm thick incl 30mm x 30mm x 6mm MS angle iron structure welded by fixing insert plates at 4 sides in cable trench top with 2 nos 3/8 TMT handle rodincl gas cutting, grinding & drilling with one coat of red laid primer and one coats of synthetic enamel paint as per direction of EIC. 112 Core cutting of 125mm thick RCC slab by suitable core cutting machine for passing necessary vertical run of Electrical Bus duct/ cables/ cable tray/ protection pipes/ earthing strip etc including mending good the damages as per direction of the EIC. 113 Minor civil works for cutting floor/ brick wall for passing electrical cables/ cable tray/ protection pipes/ earthing strip etc including mending good the damages as per direction of the EIC. 114 Supply, transporation & pouring of HSD Oil. 115 Less : Cost Item 116 Less : Cost for dismantling & unserviceableold LT Panel ( 1250A ACB-2 Nos, 1000A B/C-1,2000A Bus-Bar- 2 Sets, 250A - 630A SFU SFU - 12 Nos) installed at Gr Floor of Sub Station-IV as per direction of EIC 117 Less : Cost for dismantling & unserviceableold LT Panel ( 1600A ACB-1 Nos, 1250A ACB-1No & 1000A ACB -1 No.,2500A Bus-Bar- 01 Sets) installed at Gr Floor of Sub Station-I as per direction of EIC 118 Less : Cost for dismantling & unserviceableold LT Panel ( 400A SFU-2 Nos, 400A C/O-1No, 630A Bus-Bar, 63 - 125A SFU - 7Nos) installed at Gr Floor,Eastern side ofof UCM Building as per direction of EIC 119 Less : Cost for dismantling & unserviceableold LT Panel ( 400A SFU-2 Nos, 400A C/O-1No, 630A Bus-Bar, 63 - 125A SFU - 16 Nos) installed at Gr Floor, Western side side ofof UCM Building as per direction of EIC 120 Less : Cost for dismantling & unserviceableold LT Panel ( 400A SFU-1 Nos, 630A Bus-Bar, 125A - 250 SFU - 6 Nos) installed at Gr Floor,Eastern side ofof UCM Building as per direction of EIC 121 Less : Cost for dismantling & unserviceableold LT Panel ( 400A SFU-1 Nos, 630A Bus-Bar, 63 - 125A SFU - 6 Nos) installed at Gr Floor, Ronald RossBuilding as per direction of EIC 122 Less : Cost for dismantling & unserviceableold LT Panel ( 1250A SFU-1 Nos,200A Bus-Bar, 63 - 125A SFU - 4 Nos) installed at Gr Floor, Ronald RossBuilding as per direction of EIC 123 Less : Cost for dismantling & unserviceableold Feeder Pillar Box ( 125A SFU-1 Nos, 200A Bus-Bar, SFU unit & Starter) installed in front fo RMO Quater Gr Floor, Ronald RossBuilding as per direction of EIC 124 Less : Cost for dismantling & unserviceableold 250 - 63A SFU with enclosure installed at different places of Sub Station buildings in the campus of IPGME&R-SSKM Hospital as per direction of EIC 125 Terms and Condition: 126 The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. 127 Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. 128 If any refurbished material is supplied and installed, penal action will be taken as per existing rules 129 Defect Liability period 1 (One) Year 130 (Rates should be Quoted inclusive ofall taxes & duities and L.W.C. @ 1% as applicable)