Covering Structure Over Biofloc Unit And Allied Works At Rfdda Ghou Manhasan, Distt. Jammu.-- 1 Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 min width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavatedearth and disposal of surplus excavated earth as directed: 2 Providing and laying in position cement concrete 1 cement :5 fine sand :10 graded crushed stone aggregates 20mm size excluding the cost of centring and shuttering- all works upto plinth level. 3 Providing and laying in positioncement concrete 1 cement:3 fine sand:6 graded crushed stone aggregates 20mm size excluding the cost of centring and shuttering- all works upto plinth level. 4 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 5 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) 6 Extra for brick work with common burnt clay bricks in superstructure abpve plinth level upto floor five. 7 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class deodar wood 8 Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size withnecessary screws, excluding panelling which will be paid for separately, allcomplete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).Second class deodar wood 9 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked 10 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work 11 Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 12 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 13 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 5.22.1 Mild steel and medium tensile steel barsThermo-Mechanically Treated bars of grade Fe-500D or more.=13.50@120kg/no 14 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. 15 Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge second Class Deodar Wood 16 Centering and shuttering including strutting, propping etc. and removal of form work for: 17 Suspended floors, roofs, landings, balconies and access platforms. 18 Filling available excavated earth in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, 19 Providing and fixing electric points complete in all respects as per necessity at site including laying of PVC conduit pipes, junction box, module,MCB and laying of electric wires of a approved make and thickness and fixing of switches, installation and testing complete job. @LMR 20 Supplying and fixing of ceiling fan 1200 mm sweep of approved brands complete job 21 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length Sal Wood 22 Filling / RBM inside Plinth Sides. 23 CEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) 24 Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes 75 mm diametre 25 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 26 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete 2 mm thick 27 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 28 Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications 29 Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) 30 Providing and laying 60mm thick factory made cement conc. Interlocking Paver Block of M-30 grade made y block making machine with strong vibratory compaction and of approvedsizeand design/shape laid in required colours and pattern over and including 50mm thick compacted bed of fine sand, filling the jointswith coarse sand etc. all complete. 31 Providing corrugated G. S. sheet roofing including vertical/curved surfacefixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.25 mm thick with zinc coating not less than 275 gram/m2 32 carraiage of sand/ below 40 mm 33 carriage above 40 mmm 34 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-chargeInternal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 25mm nominal outer dia pipes.