Tender For Construction/Installation Of Porta Cabin For Vwdr At Court Campus Moradabad. - Puf Insulated 50mm wall panel with both side off white PPGI sheet puf having density 40kg/CBM Sheet AM/NS JSW Both side 0.5mm sheet. 2 Puf Insulated 40+30=70mm Corrugated roof panle with both side off white PPGI sheet PUG having Density 40kg/CBM/ AM/NS 3 Powder Coated sliding window size 1200x1200mm with mess including Rain Guard. 4 Supply & Installation 400x400 mm ventilator. 5 MS Structure with paint make Appolo with 2 coat primer & enamel paint 6 Puf Insulated door size 750x2100mm with hinges,T Bolt D handle door stopper, door closer, door lock. 7 Puf Insulated door size 1200x2100mm with hinges,T Bolt D handle door closer door lock. 8 Ridge Cover 9 PPGI Flashing U Channel, inner & Outer L silicon screw. 10 Installation puf panel with hardware Pop Revit silicon, fastner etc. 11 Providing & making false ceilling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceilling tiles of size 595x595 mm of approved texture desin and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987 Light reflectance of 85% (minimum) Non combustible as per BS : 476 (part-4) fire performance as per BS: 476 (part 6 & 7) humidity resistance of 100% thermal conductivity < 0.043 w/m K as per ASTM 518: 1991, in ture horizontal level suspened on inter locking metal powder coated T-Grid of hot dipped galvanished iron section of 0.40 mm thick on silhousette profile (White/black) comprising of main-T runners of size 15x42 mm od length 3000 mm cross T of size 15x42 mm of length 1200 mm and secondary intermediate cross T of size 15x42 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceilling using galvanised mild steel item, with 15 mm thick integral densified micro edge light weight calcium silicate false ceilling tiles DSR No. 26.23.1 excluding GST. 12 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid DSR No. 17.3.1 13 Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. DSR No. 17.7B 14 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 32 mm dia DSR No. 17.28.1 15 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR No. 17.31 16 Providing and fixing toilet paper holder : C.P. brass DSR No. 17.34.1 17 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore DSR No. 18.18.1 18 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore DSR No. 18.49.1 19 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore DSR No.18.51.1 20 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. DSR No. 18.48 21 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore DSR No. 18.52.1 22 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore DSR No. 18.53.1 23 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer dia Pipes. DSR No. 18.7.1 24 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia Pipes. DSR No. 18.7.2 25 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 2.6.1 All kinds of soil 26 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) DSR No. 4.1.8 27 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) DSR No. 4.1.4 28 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand). DSR No. 6.1.2 29 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand). DSR No. 13.4.1 30 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). DSR No. 5.1.2 31 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Mild steel and Medium Tensile steel bars. DSR No. 5.22A.1 32 Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. DSR No. 19.33 33 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete 2.25(a) 34 15 mm cement plaster : 1:4 (1 cement : 4 coarse sand). DSR No. 13.5.1 35 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. DSR No. 11.46.1 36 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). DSR No. 5.3 37 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). DSR No. 5.3 38 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more DSR No. 5.22.6 39 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. DSR No. 5.9.1