| 1 | Demolition of PCC in ground floor and paving not exceeding 15cm thick (below or above ground level) etc., complete all as specified and directed. |
| 2 | Material and Labour for Plain cement concrete 1:2:4, 50 mm thick, type B1, using 20mm graded stone aggregate as in sub-base/floor and finishing with broom or MS jalli whilst the concrete is green etc., complete all as specified and as directed. |
| 3 | Material and labour for coloured Non Skid industrial tiles, 20mm thick (square/ rectangular) area of each tile exceeding 0.18Sqm but not exceeding 0.36 sqm, laid in floors of pattern as approved over and including 20mm thick screed bed in Cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to matchall as specified and as directed. |
| 4 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed. |
| 5 | Excavating in post holes (or similar holes) each n.exc 0.5Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance n.exc 50cm and making good surface complete all as specified and as directed. |
| 6 | Supply and fix Pre-painted galvalume aluminum and zinc alloy coating steel based corrugated steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, cut as per site requirement, fixed with self drilling/self tapping screws with EPDM seal etc., complete all as specified by manufacturer specification and as directed. |
| 7 | Supply, fabricate and erection / fixing of Rolled mild steel sections as in main and cross beams, post, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Gde Fe 410-W (Gde- E-250) quality-A including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.all as specified and as directed. |
| 8 | Material and Labour for providing and fixing stainless steel railing made of hollow tubes, channels, plates etc., standard quality of grade AI SI-304, wall thickness not less than1.5mm (16 gauage) including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. complete all as specified and as directed.Note : The unit rate quoted shall be deemed to include ths cost of staging/Scaffolding and other supporting material. |
| 9 | Supply and Fix 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and as directed. |
| 10 | Material and Labour for rendering 15mm thick in Cement Mortar 1:4 on other than fair faces of brick wall or stone masnory and finished even and smooth without using extra cement complete all as specified and as directed. |
| 11 | Material and labour for Providing Gypsum board False ceiling using 8mm thick gyprex dew drop laminated gypsum ceiling tile of size 595 mmx 595 mm laminated with 0.07mm textured rigid poly Vinyl film white colour on the face side and 12 micron Metalized Polyester (MPL) film for diffusing heat & vapour on rear side with Square Edge (SE), Colour : White withLight Reflectance>80%, Humidity resistance up to RH 90% fixed with staples onpowder coated galvanized iron snap grid frame work of size 605 x 605mm using main and Cross \"T\" and angle sections (Main T Length: 3600 mm, Width 24mm, Height 38mm, Cross T Length :1200mm, Width: 24 mm, Height : 25mm and Cross T Length :600mm, Width: 24 mm, height 25mm) made out of 0.5mm thick PGI sheet, Class V, bent to shape requiredas in main member, secondary member, perimeter angle section including provn of Hanger bars 4mm dia rod/ G I wire suspender of size not less 4mm dia fixed to roof members with butterfly adjustable clip fixed to roof slabs as per manufacturer\"s instructions including taking down and refixing of electrical fittings etc., complete all asspecified and as directed .Note: The unit rate quoted shall be deemed to include the cost of taking down and refixing of the electrical fittings such as ceiling fan, light fittings etc., and refixing of the electrical fittings such as ceiling fan, light fittings etc, and keep in safe custody of same till refixing. |
| 12 | Material and Labour for applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of required shade and colour as approved over and including priming coat of inerior primer as per manufacturer\"s specification including preparation of newly plastered surface of walls, pilasters and cornices etc., complete all as specified and as directed. |