| 1 | M&L for Overhauling of incinerator unit at INS Shivaji comprising of the following repairs:-(a)General servicing of Eco flame burner-02 nos(b)Decarbonize the flame chute using long brushes, special scrubbers and remove the carbon deposits and deposit the carbon deposits away from the incinerator. (c) Replace the unserviceable sequence controller complete with new one-01 No(d) Replace the unserviceable transformer with new one - 01 No(e) Repair the cracked incinerator waste storage belly using fire bricks and cement mortar to the existing shape.(f) Remove and desilt the diesel tank and re-fix the same after removing all dust/foreign particles.(g) Clean the fuel Jet for free flow of fuel complete. |
| 2 | Material and Labour for comprehensive repair / replacement including total servicing/ overhauling of the Mechanical Laundary at INHS Kasturi comprising of the following Parts of Laundary Machine for maintenance complete (including all sprare parts ) all as specified and as directed. -a. Washer Extractor - 30 Kg Capb. Dryer Tumbeler - 30 kg Capc. Flat Iron / Calender Machine - 7 ftd. Air Compressore. Steam Boilerf. Steam Press with Table |
| 3 | M & L for disconnecting carefully and dismantling the pump set from motor unitand opening complete pump set, cleaning replacing of unserviceable parts such as gun metal bushes, rubber packing, MS Nut, Bolts, rubber coupling (spider), Air valve and worn out parts etc and reassembling, re-installing commissioning and testingfor satisfactory running complete all as specified and as directed for following capacity of pumps :-Note :- Spare parts replaced shall be measured and paid separately as \"Supply only\"Centrifugal pump set of 100 HP capacity.(cooling tower) |
| 4 | Centrifugal pump set of 30 HP capacity (ashoka swimming pool). |
| 5 | Centrifugal pump set of 10 HP capacity (old swimming pool) |
| 6 | Submersible pump set of 20 HP capacity |
| 7 | Submersible pump set of 10 HP capacity |
| 8 | M & L for overhauling of motor unit, 3 phase, 415 volts by dismantling and opening completely, cleaning internal parts thoroughly, replacing unserviceable minor parts like nut bolts, washers, terminal plate, cable lugs, greasing including insulating materials, varnishing, heating, reassembling reinstalling and testing complete all as specified and as directed for the following capacity of motor :-Note:- Unit rate quoted shall be deemed to include for minor unserviceable parts as mentioned/ required for repairs.All other major spares as specified hereinafter will be measured and paid separately as \"Supply only\". Centrifugal pump set of 100 HP capacity.(cooling tower) |
| 9 | Centrifugal pump set of 30 HP capacity (ashoka swimming pool). |
| 10 | Centrifugal pump set of 10 HP capacity (old swimming pool) |
| 11 | Submersible pump set of 20 HP capacity |
| 12 | Submersible pump set of 10 HP capacity |
| 13 | M & L for rewinding electric motor by dismantling from cable connection pump set and foundation, dismantling complete motor removing all parts thoroughly removing burnt copper wire with new one and rewinding motor 3 phase 415 with same gauge, same No of turns of super enamel copper wire including E class insulating material, varnishing, heating etc re-installing and testing etc complete all as directed by Engr-in-Charge for the following capacity:-Note :- Unit rate quoted shall be deemed to include for minor unserviceable parts as mentioned/ required for repairs.All other major spares as specified hereinafter will be measured and paid separately as \"Supply only\".Centrifugal pump set of 100 HP capacity.(cooling tower) |
| 14 | Centrifugal pump set of 30 HP capacity (ashoka swimming pool). |
| 15 | Centrifugal pump set of 10 HP capacity (old swimming pool) |
| 16 | Submersible pump set of 20 HP capacity |
| 17 | Submersible pump set of 10 HP capacity |
| 18 | Supply only following chemicals for treatment of swimming pool water Bleaching powder |
| 19 | Alum Potash crystal |
| 20 | Soda Ash |
| 21 | Copper sulphate |
| 22 | TCCA powder |
| 23 | HCL Acid |
| 24 | Sodium Hypo Chloride |
| 25 | Supply and fix ofCI Rising Spindle sluice valveMake-Kriloskar valve both ends flanged and drilled. Hand wheel made out of grey CI, complete valve confirming to IS 14846 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed of size 80 mm. |
| 26 | All as per item No 25 here in before size 100 mm. |
| 27 | All as per item No 25 here in before size 150 mm. |
| 28 | All as per item No 25 here in before size 2 00 mm. |
| 29 | Supply and lay on PCC pillars or on any position MS pipe of followingdia , Apply two coats with black paint over one coat of red oxide primer externally on the pipe line complete including welding, cutting as per site requrement of 5MM pipe well thickness, testing and commissioning to the satisfaction of Engr-in-Chargea . 250 mm |
| 30 | All as per item No 29 here in before size 150 mm. |
| 31 | All as per item No 29 here in before size 100 mm. |
| 32 | All as per item No 29here in before size 80 mm. |
| 33 | M&L for 150 mm dia MS Pipe fittings including Flange, rubber gasket packing suitable nuts, bolts, washers all fittings like brackets of any angle, short pices, welding the flanges to MS pipe complete. |
| 34 | S&F in replacement, contactor Type, ML-6, AC3-110A Amps complete all as specified and as directed. |
| 35 | All as per item no.28 but of size ML-3, AC3-40 A Amps |
| 36 | All as per item no.28 but of size MNX 32 AC3-32 A Amps |
| 37 | S & F in replacement star delta timer,operation voltage 230-415 Volt, 50 Hz complete all as specified and as directed. |
| 38 | S & F in replacement Single Phase Preventoroperation voltage 230-415 Volt, 50 Hz complete all as specified and as directed. |
| 39 | S& F in replacement push button (red,green)for motor complete all as specified and as directed. |
| 40 | All as per item No. 39 but of color yellow |
| 41 | S&F in replacement 3 Phase digital/analogue Volt meter, 0 to 500 Volt, complete all as specified and as directed. |
| 42 | S&F in replacement3 phase digital/analogue Ammetermeter, 0 to 150 Amps with CT coil of ratio 5/50 complete all as specified and as directed. |
| 43 | S&F in replacement MCCB TP 125 Amp capacity, 36 KA including disconnecting incoming cable, replacement of worn out lugs, crimping with new lugs complete all as specified and as directed.Make:legrand |
| 44 | All as per item no. 43 but of capacity 200A Make:-Legrand |
| 45 | All as per item no. 43 but of capacity 63A Make:-Legrand |
| 46 | M&LJoist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. cut to ordinary lengths i.e. within 20mm of the length indicated ( Fe-410-W(Gde-E-250) quality-A. |
| 47 | Taking up Cast iron water main of size any dia including all fittings for spigot and socket ends and lead joints including burning out lead joint and recovering lead complete all as specified as directed.Note :- (i) Excavation earthwork shall be measured and paid seperately |
| 48 | S&F cast iron Pipes with Spigot and Socket ends centrifugally cast, Class LA laid in trenches including reducing the length of required size complete all as specified as directed for following size of CI pipe :-Note :- (i) Excavation earthwork shall be measured and paid seperately. (ii) CI fitting will be measured and paid seperately.a. 250 mm bore. |
| 49 | All as per item No 48here in before size 200 mm. |
| 50 | All as per item No 48here in before size 150 mm. |
| 51 | All as per item No 48here in before size 100 mm. |
| 52 | All as per item No 48here in before size 80 mm. |
| 53 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft loose soil all as specified and directed |
| 54 | Returining, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed |
| 55 | Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceding 1.5 mtr abvoe the starting point all as specified and directed. |
| 56 | Supply, install, Design testing and commissioning of CPRI approved factory made and tested outdoor typedouble door floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved Copper bus bar of rating 160 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 2 mm SS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glandsand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified and directed and comprising of followings:- |
| 57 | (A) Incoming:- (a) Copper bus bar TPN 160 Amps - 01 Set (b) Voltmeter 3 phaseclass .5(L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter3 phaseclass1(L &T Model No-WL132020OOOO ) -01 Nos(d) Phase indicating lamp R, Y, B LED(L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 100X5 - 3 Nos (f) MCCB 200 A TPN 25 kA (Legrand) with thermal magnetic release ( Legrand Cat No 4200 55 ) -01 Nos (g)Danger notice plate/ sticker of suitable size on front panel board -01 No(B) Outgoing:- (a)MCCB 63A TPN 16 kA with thermal magnetic release ( Legrand Cat No 4200 03) -03 Nos, (b)MNX32 Contactor 3 Pole Current rating not less than 40 Amps -07 No,thermal overload Relay (L &T Cat No SS94142OOBO)-03 No ,star delta Timer (L &T Cat No 14SDT1S)-03 No, single phase preventor (L &T Cat NoMA51BC)-03 No (c) All out going LT feeders name with radium stickers -02 Nos |
| 58 | M &L for cleaning of over head reserviors underground sumps and other water storage tanks manually as described below ans all as directed by Engr-in-Charge for over head reserviors 50000 GLN capacity each at Rajendra Nagar,Pratap Nagar, INHS kasturi, victuling store.(a) Suitably blocking the incoming and outgoung and wash out pipes for avoiding mud and foreign materials deposited in the reservior getting in to pipes and chocking it prior to starting the cleaning.(b) Bail out complete water remaining in the over head reservior before cleaning the mud and other deposits.(c) Filling up the overhead reserviors full and feed the affected residential/OTM consumers enough water to sustain during the reservior cleaning period.(d) Clean the floor wall and dome of the reservoir by jetting water using rotary pressure jets, remove the sludge so deposited completely by rubbing the wall/floor with brushes and repeat removal and depositing. Approved detergent shall be used.(e) Disinfect the tank with FOA/WHO specified chemical and make the tank totally bacteria free.(f) Apply a coat of black bituminous paint on tank man hole covers including surface preparation.(g) Writing of the date of cleaining of the water tank with white letters on black background.(h) Remove the blockage from inlet/outlet/overflow pipes,refill the tank with water and supply water at supply timings ensure satisfactory distribution.Note: For Item No 58 to 65 contractor should complete tank cleaning within 5 hrs. |
| 59 | All as per item no. 58 but for 0.3 LG capacity OHT at 36 cpo\"s |
| 60 | All as per item no. 58 but for 0.2 LG capacity OHT at old kasturi tank |
| 61 | All as per item no. 58 but for 0.25 LG capacity semi U/G sump at 36 cpo\"s. |
| 62 | All as per item no. 58 but for 0.59 LG capacitysemi U/G sump at Tropo base pump house. |
| 63 | All as per item no. 58 but for 0.5 LG capacitybalancing tanks at new and old swimming pool. |
| 64 | All as per item no. 58 but for 1 LG capacitysemi U/G sump at Raw water pump house. |
| 65 | All as per item no. 58 but for 0.5 LG capacityFilteration O/H tank. |