}

Tender For Supply Of Arthroplasty Implants, dausa-Rajasthan

Medical Health And Family Welfare has published Tender For Supply Of Arthroplasty Implants. Submission Date for this Tender is 27-06-2025. Orthopedic equipment Tenders in dausa Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

49606299
Corrigendum : Tender For Supply Of Arthroplasty Implants
Tender
Indian
Rajasthan
Dausa
27-06-2025

Tender Details

supply of Arthroplasty Implants Arthroplasty Implants For Dh Dausa , Total Hip Replacement (Thr) – All Sizes Un Cemented: -(Metal On Poly) All Should Be Of Same Make Implant Should Be Usfda Approved Only , The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating/ Porous Coating. Coating Of Minimum 50-Micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed ( Optional ) , Incremental Neck Length Options, Two Offset Options Minimum And Made Up Of Ti6al4v Material. , The Acetabular Shell Should Ha Coated/ Porous Coating. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. , Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads. , Femoral Heads Should Be Cocr Metal Head With All Sizes 28Mm/32Mm/36Mm , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Total Hip Replacement (Thr) – All Sizes Un Cemented: -(Ceramic On Poly) All Should Be Of Same Make Implant Should Be Usfda Approved Only , The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating/ Porous Coating. Coating Of Minimum 50-Micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed ( Optional ) , Incremental Neck Length Options, Two Offset Options Minimum And Made Up Of Ti6al4v Material. , The Acetabular Shell Should Ha Coated/ Porous Coating. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. , Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads. , Femoral Heads Should Be Ceramic With All Sizes 28Mm/32Mm/36Mm. , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Total Hip Replacement (Thr) – All Sizes Cemented: - With Metal On Poly. Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda Approved Only , Cemented Femoral Stem Should Highly Polished, Double Tapered With Collarless Design. , The Cemented Cup Should Have Ultra-High Molecular Weight Polyethylene With Pmma Cement Spacer Easily Identifiable The Cup Position On An X-Ray. Cup Should Be Available In The I.D 28 /32 / 36 Mm With Od 46 – 60 Mm With Two Packets Of Bone Cement. , Femoral Heads Should Be Cocr Metal Head With All Sizes 28Mm/32Mm/36Mm , Total Hip Replacement (Thr) – All Sizes Hybrid ( Metal On Poly ) Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda Approved Only Note:- All Should Be Of Same Make Except Cement , The Acetabular Shell Should Ha Coated/ Porous Coating. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. , Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads. , Cemented Femoral Stem Should Highly Polished, Double Tapered With Collarless Design With Required Bone Cement. , Femoral Heads Should Be Cocr Metal With All Sizes 28Mm/32Mm/36Mm , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Total Hip Replacement (Thr) – All Sizes -Hybrid: (Ceramic On Poly) Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda Approved Only , The Acetabular Shell Should Ha Coated/ Porous Coating. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. , Cemented Femoral Stem Should Highly Polished, Double Tapered With Collarless Design With Required Bone Cement. , Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible Toaccommodate 28Mm, 32Mm, And 36Mm Heads. , Femoral Heads Should Be Ceramic With All Sizes 28Mm/32Mm/36Mm. , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Total Hip Replacement (Thr) Dual Mobility Uncemented– All Sizes ( Metal On Poly) Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only , The Acetabular Shell Should Ha Coated/ Porous Coating. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. The System Should Compose Of A Liner And Poly Insert. The System Should Incorporate The Following Dual Points Of Articulation- • 22.2Mm Or 28Mm Femoral Metal Head. • Large Polyethylene Insert That Mimics A Femoral Head , Dual Mobility Liner- • Dual Mobility Liner Should Be Made Of Cocr. • The System Should Have Inner Change Locking Mechanism And Positive Rotation Tabs • The Liner Should Come With Removal Tool Slot. • The Liner Should Be Available In All Sizes- 36 To58 , Poly Insert- The Insert Should Be Made Up Of Highly Cross Linked Polyethylene Which Should Be Wear Resistant , The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating/ Porous Coating. Coating Of Minimum 50-Micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed ( Optional ) , Incremental Neck Lengthoptions, Two Offset Options Minimum And Made Up Of Ti6al4v Material. , Femoral Heads Should Be Cocr Metal With All Sizes 22.2/ 28Mm , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Total Hip Replacement (Thr) Dual Mobility Uncemented– All Sizes ( Ceramic On Poly) Note: - All Should Be Of Same Make Implant Should Be Usfda Approved Only , The Acetabular Shell Should Ha Coated/ Porous Coating. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. A. The System Should Compose Of A Liner And Poly Insert. B. The System Should Incorporate The Following Dual Points Of Articulation- C. 22.2Mm Or 28Mm Femoral Ceramic Head. D. Large Polyethylene Insert That Mimics A Femoral Head , Dual Mobility Liner- A. Dual Mobility Liner Should Be Made Of Cocr. B. The System Should Have Inner Change Locking Mechanism And Positive Rotation Tabs C. The Liner Should Come With Removal Tool Slot. D. The Liner Should Be Available In All Sizes- 36 To58 , Poly Insert- A. The Insert Should Be Made Up Of Highly Cross Linked Polyethylene Which Should Be Wear Resistant , The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating/ Porous Coating. Coating Of Minimum 50-Micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed ( Optional ) , Incremental Neck Lengthoptions, Two Offset Options Minimum And Made Up Of Ti6al4v Material. , Femoral Heads Should Be Ceramic With All Sizes 22.2/ 28Mm , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Total Hip Replacement (Thr) Dual Mobility Cemented – All Sizes ( Metal On Poly) Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda Approved Only • Cemented Dual Mobilty Should Have Sizes 45 To 63 • Head Sizes 22 And 28 With 4 Option • Can Be Converted With Uncemented Dm With Same Instruments On Table , Total Hip Replacement (Thr) Dual Mobility Cemented – All Sizes ( Ceramic On Poly) Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda Approved Only • Cemented Dual Mobilty Should Have Sizes 45 To 63 • Head Sizes 22 And 28 With 4 Option • Can Be Converted With Uncemented Dm With Same Instruments On Table , Complex/ Revision Hip Replacement With All Type & Size Of Wedges & Cages Etc.Thr. Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda Approved Only , Revision Uncemented Stem Should Be Long And Length Should Be Between 180 - 380 Mm, Modular Or Distal Fixing Stem. , Revision Uncemented Acetabular Shell Have Multi Hole With Min. 8 Holes And Ha/ Highly Porous Coated. , Revision Uncemented Acetabular Shell Should Provide Dual Mobility Cup Which Composed Of Cocr Liner And Highly Crossed Linked Polyethylene Which Support 22- And 28-Mm Femoral Metal Head.(Optional) , Acetabulum Augments , Acetabulum Mesh. , Acetabulum Cages Various Sizes , Uncemented Acetabular Shell Especially Designed For Protrusion Which Is Peripherally Locking. , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Revision Cemented Stem Should Long And The Length Would More Than 200 Mm, With Bone Cements. , The Cemented Cup Should Have Ultra-High Molecular Weight Polyethylene With Pmma Cementspacer Easily Identifiable The Cup Position On An X-Ray. Cup Should Be Available In The I.D 28 /32 / 36Mm With Od 46 – 60 Mm. , The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating/ Porous Coating. Coating Of Minimum 50-Micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed ( Optional ) , Incremental Neck Length Options, Two Offset Options Minimum And Made Up Of Ti6al4v Material. , Femoral Heads Should Be Cocr Metal Head With All Sizes 22Mm/ 28Mm/ 32Mm/ 36Mm. , Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads. , Femoral Heads Should Be Ceramic With All Sizes 28Mm/32Mm/36Mm. , Total Knee Replacement Cemented(Tkr) – All Sizes Note: - All Should Be Of Same Make Except Cement Should Provide Option Both Ps And Cr Knee In Same Implant Implant Should Be Usfda Approved Only , Primary Cemented Tkr- Femoral Components Various Sizes, Gender Specific , Tibial Baseplate Various Sizes, Titanium, Anatomical Tibia Base Plate , Highly Crossed Linked Polyethylene Various Sizes, Should Have Option For High Fkex, Constrained Poly Inn Same Poly , Patellar Component Various Sizes , Bone Cement Note: - All Should Be Of Same Make Except Cement , Unicondylar Knee Replacement Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda Approved Only , Fix Bearing Various Sizes , Mobile Bearing Various Sizes , Complex Primary Knee Replacement All Size And Stems And Wedges Cemented Tkr Should Have Following Components Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda Approved Only , Femoral Components Compatible With Stem Extension , Tibial Baseplate Compatible To Stem Extension , Primary Highly Crossed Linked Polyethylene , Bone Cement Antibiotic/ Normal , Fluted Stem , Patellar Component , Revision Knee Replacement All Size And Stems And Wedges Semi Constraint Tkr Should Have Following Components Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda Approved Only , Femoral Component Compatible With Stem Extension. , Tibial Baseplate Compatible To Stem Extension. , Semi Constrained Polyethylene. , Distal Augments. , Posterior Augments , Offset , Tibial Wedges Various Options , Patellar Component , Fluted Stem , Bone Cement , Revision Knee Replacement All Size And Stems And Wedges Hinge Tkr Should Have Following Components Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda Approved Only , Femoral Component Compatible With Stem Extension. , Tibial Baseplate Compatible To Stem Extension. , Constrained Polyethylene. , Distal Augments. , Posterior Augments , Offset , Tibial Wedges Various Options , Patellar Component , Fluted Stem , Bone Cement , Reverse Shoulder Replacement Implants – All Sizes All Should Be Of Same Make Implant Should Be Usfda Approved Only . • Platform Based Should And Can Be Converted Total/Reverse And Even Revisionglenoid Hase A Same Stem • 3 Types Of Stems Trauma 11A And Cemented Stem Stem Made Of Titanium Alloy (Ta6v)And Coated With Hydroxyapatite. • Stem Is Available In 5 Sizes. Long Stem Available For Humeral Revision Cases Stem Has Mm Augment (For If The Stem Has Sunk Or Any Unseen Circumstances). • Hydroxy Apetitecouted Helical Glenoid Baseplate For Reverse Shoulder Arthroplasty. • Should Have Glenoid Glenosphere Has To He Revision Base Plate Option • Should Have Instrumens For Both Surgical Approaches Delto-Pectoral Or Supero-Lateral Approaches With Same Set Of Instrumets. • Humeral Cup Has 8 Inclination With 2 Sizes 32Mm And 37Mn And Humeral Cut Vaihe Anatomic Value Of 132O • Humeral Cup Liner Has 0.+ 25 And + 5Mm Three Options For Same Cup. Note - Note Should Provide Quotation For Individual Components , Total Shoulder Replacement (Tsr) Implants- All Sizes Implant Should Be Usfda Approved Only All Should Be Of Same Make • Should Have Pe Glenoid With At Least Three Sizes • Stem As Per Rsa Specs Note - Note Should Provide Quotation For Individual Components , Hemi Shoulder Replacement Implants – All Sizes Including Fracture Stem All Should Be Of Same Make Implant Should Be Usfda Approved Only • Should Have Five Humeral Head Option • Should Have Module With Offset Option • Should Have Trauma Stem • Stem Should Be Titanium With Proximal Porous Plasma Spray Coating. • It Should Be Convertible From Total To Reverse Shoulder. • Diameter Should Be In 1Mm Increment Or 2 Mm Increment With Fracture Stems. • Can Be Used With Or Without Bone Cement. • Fins With Holes Should Be Present To Tie The Tuberosity In Fracture Stems Note - Note Should Provide Quotation For Individual Components , Total Elbow Replacement (Ter) – Implants – All Sizes Implant Should Be Usfda Approved Only All Should Be Of Same Make Except Cement Total Elbow Replacement Set With Consisting Of Long Flange Plasma Spray Coated Humeral Stem And Side Specific Left/Right) Plasma Spray Coated Ulnar Stem Component With Antibiotic Bone Cement Usfda Fill Quality Assurance And Should Be Mri Compatible.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 16-06-2025 Date Extend Date 24-06-2025
2 18-06-2025 Items updagte and add BOQ 24-06-2025
3 24-06-2025 date extend Date 27-06-2025

Key Value

Document Fees
INR 2000 /-
EMD
INR 196000.0 /-
Tender Value
INR 98 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail