Supply, Erection, Testing and Commissioning of New Numerical Distance Relay P442 Type and (IEC61850) Over Current, Earth Fault Relay &Undervoltage and Overvoltagerelay under various substations of 220 KV S/S Div Panki Kanpur - Supply, Erection, Testing and Commissioning of New Numerical Distance Relay 2 supply, erection, testing & commissioning of newnumeric Undervoltage and Overvoltagerelayand Unbalance Relay of Siemens/ABB/ALSTOM Make on 33 kV triple feeder control and relay panel of 33 KV10 MVAR Cap Bank 3 feeder at 220 KV S/S Panki. Removal of old relays & housing of old relay from panel cabinet. Preparation of Panel cabinet by cutting & adding New Bakelite sheet/M.S. Sheet forplacement of housing of new numerical relay as per site requirement for new relay housing. Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of old and defectiverelay connection/termination as per new drawing submitted & approved by department.The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical relay, annunciation fascia and unbalance relayNote: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders. 3 supply, erection, testing & commissioning ofnumeric (IC 61850) over current, earth fault relay and High speed Master Trip Relayof Siemens/ABB/ALSTOM Make on 33 kV 10 MVAR Capacitorcontrol and relay panel of 33 KV10 MVAR Cap Bank 3 feeder at 220 KV S/S Panki. Removal of old relays & housing of old relay from panel cabinet. Preparation of Panel cabinet by cutting & adding New Bakelite sheet/M.S. Sheet forplacement of housing of new numerical relay as per site requirement for new relay housing & master trip relay with proper placement of new relay. Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of old and defective static relay connection/termination as per new drawing submitted & approved by department.The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical relay, annunciation fascia and unbalance relayNote: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders. 4 supply, erection, testing & commissioning ofnumeric (IC 61850) over current, earth fault relay andUnbalanceRelayof Siemens/ABB/ALSTOM Make oncontrol and relay panel of 132 KV40 MVAR Cap Bankfeeder at 220 KV S/S Panki. Removal of old relays & housing of old relay from panel cabinet. Preparation of Panel cabinet by cutting & adding New Bakelite sheet/M.S. Sheet forplacement of housing of new numerical relay as per site requirement for new relay housingwith proper placement of new relay. Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of old and defective static relay connection/termination as per new drawing submitted & approved by department.The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical relay, annunciation fascia and unbalance relayNote: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders. 5 supply, erection, testing & commissioning ofnumeric Undervoltage and Overvoltage relayand Unbalance Relay of Siemens/ABB/ALSTOM Make oncontrol and relay panel of 132 KV40 MVAR Cap Bankfeeder at 220 KV S/S Panki. Removal of old relays & housing of old relay from panel cabinet. Preparation of Panel cabinet by cutting & adding New Bakelite sheet/M.S. Sheet forplacement of housing of new numerical relay as per site requirement for new relay housing. Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of old and defective static relay connection/termination as per new drawing submitted & approved by department.The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical relay, annunciation fascia and unbalance relayNote: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders. 6 Supply, erection, testing & commissioning of numeric (IC 61850) over current, earth fault relay and High Speed Master Trip Relay of Siemens/ABB/Alstom Make on control and relay panel 220 KV Bus Coupler Bay feeder at 220 KV S/S Panki. Removal of old relays & housing of old relay from panel cabinet. Preparation of Panel Cabinet by cutting & adding New Bakelite sheet/M.S. Sheet for placement of housing of new numerical relay as per site requirement for new relay housing & master trip relay with proper placement of new relay. Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of old and defective static relay connection/termination as per new drawing submitted & approved by department. The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical Relay. annunciation fascia and unbalance relay. Note: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders. 7 Supply, erection, testing & commissioning of numeric (IC 61850) over current, earth fault relay and High Speed Master Trip Relay of Siemens/ABB/Alstom Make on control and relay panel 132 KV Bus Coupler Bay feeder at 220 KV S/S Panki. Removal of old relays & housing of old relay from panel cabinet. Preparation of Panel Cabinet by cutting & adding New Bakelite sheet/M.S. Sheet for placement of housing of new numerical relay as per site requirement for new relay housing & master trip relay with proper placement of new relay. Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of old and defective static relay connection/termination as per new drawing submitted & approved by department. The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical Relay. annunciation fascia and unbalance relay. Note: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders. 8 supply, erection, testing & commissioning ofnumeric (IC 61850) over current, earth fault relay ) and Master TripRelay of Siemens/ABB/ALSTOM Make oncontrol and relay panelof 33/11 KV 05 MVA Bay feeder at 220 KV S/S Panki. Removal of old relays & housing of old relay from panel cabinet. Preparation of Panel cabinet by cutting & adding New Bakelite sheet/M.S. Sheet forplacement of housing of new numerical relay as per site requirement for new relay housing & master trip relay with proper placement of new relay. Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of old and defective static relay connection/termination as per new drawing submitted & approved by department.The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical relay, annunciation fascia and unbalance relayNote: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders. 9 supply, erection, testing & commissioning ofnumeric (IC 61850) over current, earth fault relayand Master TripRelay of Siemens/ABB/ALSTOM Make oncontrol and relay panelof 132/33 40 MVA TF III Feederat 220 KV S/S Panki. Removal of old relays & housing of old relay from panel cabinet. Preparation of Panel cabinet by cutting & adding New Bakelite sheet/M.S. Sheet forplacement of housing of new numerical relay as per site requirement for new relay housing & master trip relay with proper placement of new relay. Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of old and defective static relay connection/termination as per new drawing submitted & approved by department.The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical relay, annunciation fascia and unbalance relayNote: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders. 10 supply, erection, testing & commissioning ofnumeric (IC 61850) Directional over current, earth fault relay as (SIEMENS make) and Master TripRelay of Siemens/ABB/ALSTOM Make oncontrol and relay panel of various 132 KV Line Feeders( Armapur I,II & Jawaharpuram) Feederat 220 KV S/S Panki. Removal of old relays & housing of old relay from panel cabinet. Preparation of Panel cabinet by cutting & adding New Bakelite sheet/M.S. Sheet forplacement of housing of new numerical relay as per site requirement for new relay housing & master trip relay with proper placement of new relay. Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of old and defective static relay connection/termination as per new drawing submitted & approved by department.The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical relay, annunciation fascia and unbalance relayNote: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders. 11 supply, erection, testing & commissioning ofnumeric Distance Protection RelayType P442 (SIEMENS/ABB/GEmake)onVarious 220 KV Line feeder control and relay panel at 220 KV S/S Panki. Removal of old relays & housing of old relay from panel cabinet. Preparation of Panel cabinet by cutting & adding New Bakelite sheet/M.S. Sheet forplacement of housing of new numerical relay as per site requirement for new relay housing with proper placement of new relay. Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of oldrelay connection/termination as per new drawing submitted & approved by department.The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical relay, annunciation fascia and master trip relayNote: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders. Autoreclose function will be enabled on all line feeders including all other necessary works including laying and termination of control cables if required from CB to Control and relay Panel and after that testing will be done for Autoreclose function also. 12 supply, erection, testing & commissioning of numeric Distance Protection RelayType P442 (SIEMENS/ABB/GEmake) and high speed master trip relay of Siemens/ABB/ALSTOM Make onVarious 220 KV Line feeder control and relay panel at 220 KV S/S Panki. Removal of old relays & housing of old relay from panel cabinet. Preparation of Panel cabinet by cutting & adding New Bakelite sheet/M.S. Sheet forplacement of housing of new numerical relay as per site requirement for new relay housing & master trip relay with proper placement of new relay. Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of old and defective static relay connection/termination as per new drawing submitted & approved by department.The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical relay, annunciation fascia and master trip relayNote: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders. Autoreclose function will be enabled on all line feeders including all other necessary works including laying and termination of control cables if required from CB to Control and relay Panel and after that testing will be done for Autoreclose function also. 13 Retrofitting ofnumerical over current, earth fault relay to different control & relay panels installed at 132 KV S/S Armapur and 220 KV S/S Panki.Preparation of Panel cabinet by cutting & adding New Bakelite sheet/M.S. Sheet forplacement of housing of new numerical relay as per site requirement for new relay housing . Preparation of interconnection drawing & modification in panel wiring for the new numerical relay to be installed on panels, in place of old and defective static relay connection/termination as per new drawing submitted & approved by department.The work also includes supply of 4A Double Pole 110 V DC MCB and its wiring and termination of Numerical relay, annunciation fascia and unbalance relayNote: All the replacement of relay work shall becompleted in one go there should not be any disturbance to the wiring of other feeders.