Operation And Maintenance Of Gap Filling Fund 2025-26 In Vadakku Valliyur Town Panchayat Providing Eb Service Connections, Panel Board (222 Shops) 34 Nos. Street Light, 12 Mtr Stage Highmast Light In Shandy.- 1 Supply, delivery and erection of 12 meter High Mast System totally Hot dip galvanized in2 Sections in dimentions of Base-450mm and Top section-200mm with Galvanization thickness for bottom-85 Microns and Top of 65 Microns, Double door and interlocking arrangements, Mast Bottom section thickness of 5mm and Top section of 4mm Suitable for 50Mtrs / sec wind velocity fixed Head frame with canopy movable Lantern carriage three/double drum winch, Hosting Stain Less Steel ropes, flexible Multicore Heat proof power cable capable of withstanding up to 50Mts / sec Air velocity including supply and fixing of 8Nos of 200watts LED Flood Light Luminaries energy saverfitting with COB diodes in die cast aluminium housing and IP 65 protection of reputed brand manufacturing in india with surge protection of 10kw and Supply and Fixing of Obstruction Aviation Light as specified in the Relevant ISS codes as per standard and as directed by the dept. officers.(SUB DATA -1) 2 Design and casting of pedestal type RCC Foundation to SBC of soil 10T/M2 including earth work excavation, RCC works with necessary RTS rods with standard designs, steel Centering, Foundation bolls & nuts manufactures in special steel with anchor plates and templates etc. as per standard and as directed by the dept. officers (SUB DATA -2) 3 Supply and Laying of 3 1/2 x 25 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (SD 659) 4 Supply and clarnping of 3 1/2 x 35 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps as per standard.etc., complete for Service connection usage. (SD 201) 5 Supply and providing cable end termination of 3-1/2 x 25sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. (SD 213) 6 Supply and providing cable end termination of 3 - 1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. (SD 214) 7 Supply and fixng of TNEB Meter Board suitable for 3 Phases 32A service connection in fabricated Powder coated sheet metal box made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2 x 1 1/2 x 1/4 rigidly fixed on EB Pole covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary MS Clamp sets, bolts and nuts and supply and fixing of 3 Nos 63A fuse units (500V) 1 No. Neutral link, copper earth flat of size 1 x 1/4 with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete.(SD 131A) 8 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. (SD 211) 9 Labour for cutting open road for laying water mains or sewer. B.T. Roads (or) Maccadam road (PWD Vol -II) WD-W0739 p.no 195 10 Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum 11 Refilling with excavated soil (other than sand) complyingwith standard specification for filling in foundation andbasement.SOR Vol 1 W-0075 P.No -29 12 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 13 Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., complete as per standard specification 14 supply and fixing of 65 mm dia. (2 -1/2) GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour . (SD 456) 15 Metering panel 1 With Kiosk Arrangements :Design, Procurement, Fabrication, Assembling, supply, installation, and Commissionh of the Metering Panel with Kiosk arrangements. The Specification as follows, Metering Panel Consists of Single phase metering Slot Suitable for Tangedco meter 32 No With 12 mm Metring Board andMIrror view arrangemnts,32A Porchelain FuseFor Each Chamber for for protection, 32A 100mA, Double Pole RCCBfor each chamber, 25 x 6 or Equlaient sizeCopper Bus Bar for Each Phase and Neutral with suitable heat shrinkable sleeve. 6 Sqmm Wired Interlinks (Phase and neutral)for Bus bar to EB Meter, Eb Meter to Fuse, Fuse to RCCB.with Suitable Copper Lugs. Panel Madeup of with SWG 18 gauge Sheet, withsiemens clour powder coating. Sheet will be tata sheet, RCCBwill be L&T or EqulaentAlomg with sitable size kiosk arrangements for the above metyering panel, Kiosk arrangemnt is made up of with 16 swg sheeted with suitable angle frame,Kiosk with suitable double door. Kiosk Cloured with Grey clour eneamalspray paint. Metering Panel Size L 4400 x H 1150 x W 250 MM 16 a. 32A Porcelin Fuse 17 b. 40A 100 MA Double Pole RCCB 18 c. 32A Neutral Link 19 d. Interconnection with 6 Sqmm PVC Insulated Cable 20 Metering panel 2 With Kiosk Arrangements :Design, Procurement, Fabrication, Assembling, supply, installation, and Commissionh of the Metering Panel with Kiosk arrangements. The Specification as follows, Metering Panel Consists of Single phase metering Slot Suitable for Tangedco meter 23 No With 12 mm Metring Board andMIrror view arrangemnts,32A Porchelain FuseFor Each Chamber for for protection, 32A 100mA, Double Pole RCCBfor each chamber, 25 x 6 or Equlaient sizeCopper Bus Bar for Each Phase and Neutral with suitable heat shrinkable sleeve. 6 Sqmm Wired Interlinks (Phase and neutral)for Bus bar to EB Meter, Eb Meter to Fuse, Fuse to RCCB.with Suitable Copper Lugs. Panel Madeup of with SWG 18 gauge Sheet, withsiemens clour powder coating. Sheet will be tata sheet, RCCBwill be L&T or EqulaentAlomg with sitable size kiosk arrangements for the above metyering panel, Kiosk arrangemnt is made up of with 16 swg sheeted with suitable angle frame,Kiosk with suitable double door. Kiosk Cloured with Grey clour eneamalspray paint. Metering Panel Size L 4400 x H 1150 x W 250 MM 21 a. 32A Porcelin Fuse 22 b. 40A 100 mA Double Pole RCCB 23 c. 32A Neutral Link 24 d. Interconnection with 6 Sqmm PVC Insulated Cable 25 Metering panel 3 With Kiosk Arrangements :Design, Procurement, Fabrication, Assembling, supply, installation, and Commissionh of the Metering Panel with Kiosk arrangements. The Specification as follows, Metering Panel Consists of Single phase metering Slot Suitable for Tangedco meter 22 No With 12 mm Metring Board andMIrror view arrangemnts,32A Porchelain FuseFor Each Chamber for for protection, 32A 100mA, Double Pole RCCBfor each chamber, 25 x 6 or Equlaient sizeCopper Bus Bar for Each Phase and Neutral with suitable heat shrinkable sleeve. 6 Sqmm Wired Interlinks (Phase and neutral)for Bus bar to EB Meter, Eb Meter to Fuse, Fuse to RCCB.with Suitable Copper Lugs. Panel Madeup of with SWG 18 gauge Sheet, withsiemens clour powder coating. Sheet will be tata sheet, RCCBwill be L&T or EqulaentAlomg with sitable size kiosk arrangements for the above metyering panel, Kiosk arrangemnt is made up of with 16 swg sheeted with suitable angle frame,Kiosk with suitable double door. Kiosk Cloured with Grey clour eneamalspray paint. Metering Panel Size L 4400 x H 1150 x W 250 MM 26 a. 32A Porcelin Fuse 27 b. 40A 100 mA Double Pole RCCB 28 c. 32A Neutral Link 29 d. Interconnection with 6 Sqmm PVC Insulated Cable 30 Metering panel 4 With Kiosk Arrangements :Design, Procurement, Fabrication, Assembling, supply, installation, and Commissionh of the Metering Panel with Kiosk arrangements. The Specification as follows, Metering Panel Consists of Single phase metering Slot Suitable for Tangedco meter 20 No With 12 mm Metring Board andMIrror view arrangemnts,32A Porchelain FuseFor Each Chamber for for protection, 32A 100mA, Double Pole RCCBfor each chamber, 25 x 6 or Equlaient sizeCopper Bus Bar for Each Phase and Neutral with suitable heat shrinkable sleeve. 6 Sqmm Wired Interlinks (Phase and neutral)for Bus bar to EB Meter, Eb Meter to Fuse, Fuse to RCCB.with Suitable Copper Lugs. Panel Madeup of with SWG 18 gauge Sheet, withsiemens clour powder coating. Sheet will be tata sheet, RCCBwill be L&T or EqulaentAlomg with sitable size kiosk arrangements for the above metyering panel, Kiosk arrangemnt is made up of with 16 swg sheeted with suitable angle frame,Kiosk with suitable double door. Kiosk Cloured with Grey clour eneamalspray paint. Metering Panel Size L 4400 x H 1150 x W 250 MM 31 a. 32A Porcelin Fuse 32 b. 40A 100 mA Double Pole RCCB 33 c. 32A Neutral Link 34 d. Interconnection with 6 Sqmm PVC Insulated Cable 35 Metering panel 5 With Kiosk Arrangements :Design, Procurement, Fabrication, Assembling, supply, installation, and Commissionh of the Metering Panel with Kiosk arrangements. The Specification as follows, Metering Panel Consists of Single phase metering Slot Suitable for Tangedco meter 18 No With 12 mm Metring Board andMIrror view arrangemnts,32A Porchelain FuseFor Each Chamber for for protection, 32A 100mA, Double Pole RCCBfor each chamber, 25 x 6 or Equlaient sizeCopper Bus Bar for Each Phase and Neutral with suitable heat shrinkable sleeve. 6 Sqmm Wired Interlinks (Phase and neutral)for Bus bar to EB Meter, Eb Meter to Fuse, Fuse to RCCB.with Suitable Copper Lugs. Panel Madeup of with SWG 18 gauge Sheet, withsiemens clour powder coating. Sheet will be tata sheet, RCCBwill be L&T or EqulaentAlomg with sitable size kiosk arrangements for the above metyering panel, Kiosk arrangemnt is made up of with 16 swg sheeted with suitable angle frame,Kiosk with suitable double door. Kiosk Cloured with Grey clour eneamalspray paint. Metering Panel Size L 4400 x H 1150 x W 250 MM 36 a. 32A Porcelin Fuse 37 b. 40A 100 mA Double Pole RCCB 38 c. 32A Neutral Link 39 d. Interconnection with 6 Sqmm PVC Insulated Cable 40 Metering panel 6 With Kiosk Arrangements :Design, Procurement, Fabrication, Assembling, supply, installation, and Commissionh of the Metering Panel with Kiosk arrangements. The Specification as follows, Metering Panel Consists of Single phase metering Slot Suitable for Tangedco meter 10No With 12 mm Metring Board andMIrror view arrangemnts,32A Porchelain FuseFor Each Chamber for for protection, 32A 100mA, Double Pole RCCBfor each chamber, 25 x 6 or Equlaient sizeCopper Bus Bar for Each Phase and Neutral with suitable heat shrinkable sleeve. 6 Sqmm Wired Interlinks (Phase and neutral)for Bus bar to EB Meter, Eb Meter to Fuse, Fuse to RCCB.with Suitable Copper Lugs. Panel Madeup of with SWG 18 gauge Sheet, withsiemens clour powder coating. Sheet will be tata sheet, RCCBwill be L&T or EqulaentAlomg with sitable size kiosk arrangements for the above metyering panel, Kiosk arrangemnt is made up of with 16 swg sheeted with suitable angle frame,Kiosk with suitable double door. Kiosk Cloured with Grey clour eneamalspray paint. Metering Panel Size L 4400 x H 1150 x W 250 MM 41 a. 32A Porcelin Fuse 42 b. 40A 100 mA Double Pole RCCB 43 c. 32A Neutral Link 44 d. Interconnection with 6 Sqmm PVC Insulated Cable 45 Metering panel 7 With Kiosk Arrangements :Design, Procurement, Fabrication, Assembling, supply, installation, and Commissionh of the Metering Panel with Kiosk arrangements. The Specification as follows, Metering Panel Consists of Single phase metering Slot Suitable for Tangedco meter 8 No With 12 mm Metring Board andMIrror view arrangemnts,32A Porchelain FuseFor Each Chamber for for protection, 32A 100mA, Double Pole RCCBfor each chamber, 25 x 6 or Equlaient sizeCopper Bus Bar for Each Phase and Neutral with suitable heat shrinkable sleeve. 6 Sqmm Wired Interlinks (Phase and neutral)for Bus bar to EB Meter, Eb Meter to Fuse, Fuse to RCCB.with Suitable Copper Lugs. Panel Madeup of with SWG 18 gauge Sheet, withsiemens clour powder coating. Sheet will be tata sheet, RCCBwill be L&T or EqulaentAlomg with sitable size kiosk arrangements for the above metyering panel, Kiosk arrangemnt is made up of with 16 swg sheeted with suitable angle frame,Kiosk with suitable double door. Kiosk Cloured with Grey clour eneamalspray paint. Metering Panel Size L 4400 x H 1150 x W 250 MM 46 a. 32A Porcelin Fuse 47 b. 40A 100 mA Double Pole RCCB 48 c. 32A Neutral Link 49 d. Interconnection with 6 Sqmm PVC Insulated Cable 50 Metering panel 8 With Kiosk Arrangements :Design, Procurement, Fabrication, Assembling, supply, installation, and Commissionh of the Metering Panel with Kiosk arrangements. The Specification as follows, Metering Panel Consists of Single phase metering Slot Suitable for Tangedco meter 32 No With 12 mm Metring Board andMIrror view arrangemnts,32A Porchelain FuseFor Each Chamber for for protection, 32A 100mA, Double Pole RCCBfor each chamber, 25 x 6 or Equlaient sizeCopper Bus Bar for Each Phase and Neutral with suitable heat shrinkable sleeve. 6 Sqmm Wired Interlinks (Phase and neutral)for Bus bar to EB Meter, Eb Meter to Fuse, Fuse to RCCB.with Suitable Copper Lugs. Panel Madeup of with SWG 18 gauge Sheet, withsiemens clour powder coating. Sheet will be tata sheet, RCCBwill be L&T or EqulaentAlomg with sitable size kiosk arrangements for the above metyering panel, Kiosk arrangemnt is made up of with 16 swg sheeted with suitable angle frame,Kiosk with suitable double door. Kiosk Cloured with Grey clour eneamalspray paint. Metering Panel Size L 4400 x H 1150 x W 250 MM 51 a. 32A Porcelin Fuse 52 b. 40A 100 mA Double Pole RCCB 53 c. 32A Neutral Link 54 d. Interconnection with 6 Sqmm PVC Insulated Cable 55 Junction BoxDesign, Procurement, Fabrication, Assembling, supply, installation, and Commissionhs of 800Aout door junction box.The Specification as follows.Junction box Consists of 800A HRC Fuse Holders - 3 Nos and 630 A HRC Fuse - 3 No. 1 Runs of 50mm x 10mm or EqulanetCopper Bus bar Suitable for 800A. Bus Bar Covered with Suitable Heat Srinkable Sleeves. The out going taken from suitable suitable copper bus bar. Junction Box 1 connected with 110 Single phase meters, Junction Box 2 Connected with 113 Single PHase Meters, Hunction Box Sixe L 1400 x H 1000 X W 400 MM Along With Covered With the GI Wired Fencing For Safety Fencing. And Door Arrangement with suitable Clambing Arrangements 56 Junction Box 1- 6Design, Procurement, Fabrication, Assembling, supply, installation, and Commissionhs of 300Aout door junction box.The Specification as follows.Junction box Consists of 800A HRC Fuse Holders - 3 Nos and 630 A HRC Fuse - 3 No. 1 Runs of 25mm x 10mm or EqulanetCopper Bus bar Suitable for 800A. Bus Bar Covered with Suitable Heat Srinkable Sleeves. The out going taken from suitable suitable copper bus bar. Junction Box 1 connected with 110 Single phase meters, Junction Box 2 Connected with 113 Single PHase Meters, Hunction Box Sixe L 1400 x H 1000 X W 400 MM Along With Covered With the GI Wired Fencing For Safety Fencing. And Door Arrangement with suitable Clambing Arrangements 57 Supply of 3 Mtr x 48 mm GIEarth Pipe with 50 kg backfilling earthing electrode including bolt and nut ( SD211) 58 Supply and Laying Of 8 SWG Copper Wire (SD 370) 59 Supply and Laying of 400Sqmm x 3.5C Alu. Arm. Cable (SD192) 60 Supply and Laying of 120 Sqmm x 4 C Alu. Arm. Cable (SD 187) 61 Supply and Laying of 95 Sqmm x 4 C Alu. Arm. Cable (SD 186) 62 Supply and Laying of 70 Sqmm x 4 C Alu. Arm. Cable(SD 185) 63 Supply and Laying of 50 Sqmm x 4 C Alu. Arm. Cable (SD 184) 64 Supply and Laying of 35 Sqmm x 4 C Alu. Arm. Cable (SD 183) 65 Supply and Fixing of brass Cable gland of 400Sqmm x 3.5 C Al. Arm Cable (SD 174) 66 Supply and Fixing of brass Cable gland of 120 Sqmm x 3.5 C Al. Arm Cable (SD 169) 67 Supply and Fixing of brass Cable gland of 95 Sqmm x 3.5 C Al. Arm Cable (SD 168) 68 Supply and Fixing of brass Cable gland of 70Sqmm x 3.5 C Al. Arm Cable (SD 167) 69 Supply and Fixing of brass Cable gland of 50 Sqmm x 3.5 C Al. Arm Cable(SD 166) 70 Supply and Fixing of brass Cable gland of 35 Sqmm x 3.5 C Al. Arm Cable (SD 165) 71 Supply and Termination of 400Sqmm x 3.5C Alu. Arm. Cable 72 Supply and Termination of 120 Sqmm x 4 C Alu. Arm. Cable (SD 218) 73 Supply and Termination of 95 Sqmm x 4 C Alu. Arm. Cable(SD 217) 74 Supply and Termination of 70 Sqmm x 4 C Alu. Arm. Cable (SD 216) 75 Supply and Terminationof 50 Sqmm x 4 C Alu. Arm. Cable (SD 215) 76 Supply and Terminationof 35 Sqmm x 4 C Alu. Arm. Cable (SD 214)