Drinking Water Supply and Sanitation Boards / Undertakings / PSU Closing in 0 days TDR #49575055

Tender For Repairing Of Flash Mixers, No-11And12 At 3Rd Filter House At Wazirabad Water Works.

Issued by Boards / Undertakings / PSU · wazirabad, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Jun 2025
0 days left
EMD
17900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
wazirabad → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repairing Of Flash Mixers, No-11And12 At 3Rd Filter House At Wazirabad Water Works.

BOQ

Name of Work: Repairing of Flash Mixers, No-11&12 at 3rd Filter House at Wazirabad Water Works.
Sl. No. Item Description
1Dismantling of Motor, Gear box from the foundation after disconnecting all electrical connections from the panel, opening the coupler & fan from the shaft & cutting rusted nut-bolts etc. and taking out all from the deep well.
2Dismantling of complete M.S jaal of the two wellThis also includes the M.S jaal of size 51 ft. x 11 ft. approx. for motor foundation area along with complete jaal of two raw water well of clarifier no11 &12 and chequered sheet and flash mixers all complete and deposition of all the scrap material to scrap yard as per direction of Engineer-in-charge.
3Dismantling of rusted worn out Motor platform/foundation from the flash mixture top chamber. The job includes removing of existing electrical panel, removing of rusted grill & cutting of rusted \"C\" channel with the help of gas cutter & taking it out with the help of heavy-duty manual labour arrangement etc.
4Safety equipments like gum boot, oxygen cylinder safety belt and safety helmet etc. all arranged to the safety of workers as the work has to be done in the top of flash mixture chamber. The same includes loading, unloading & cartage charges etc.
5Temporary arrangement of platform around the flash mixer well to execute the work including tool & tackles, plates, balli, jacks, chain block, chains etc. to & fro and its loading & unloading & its complete dismantling after completion of work
6Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DJB SOR 47.1.2
7Fabrication of new structure of Motor platform/foundation for the flash mixture top chamber made out from 200mm C-channel for mounting of motor & gear box of flash mixture. The size of frame is 4ft X 2.5ft approx. the job includes fixing of 8mm M.S. sheet on top of C-channel M.S structure.
8Fixing of M.S. structure on flash mixture top chamber. The job includes loading & unloading of complete frame with the help of heavy manual labour arrangement
9Overhauling of flash mixer motor and gear box including replacement of all gaskets, hardware items etc. all required during renovation must be replaced and gear box shaft for fixing of pulley as per site requirement
10Making and supply of G.M/S.S bush with bush holder as per sample.
11Making and supply of S.S shaft of size 50 mm x 2.45mtr as per sample.
12Making and supply of S.S coupler for joining of gear box with main shaft.
13Making and supply of fan suitable for above shaft as per sample.
14Providing & fixing of I-section beam of inside deep well for holding the G.M/S. S bush with bush holder for free movement of vertical shaft. The job includes fixing of M.S platesat both ends of I-section beam with the help of anchor bolts etc. as per site requirement.
15Providing and fixing of M.S angle inside deep well for holding the G.M/S. S bush with bush holder for free movement of vertical shaft. The job includes fixing of M.S plates of size as per required at both ends of .S. angle with the help of anchor bolts etc.as per site requirement.
16Re-fixing of all items like motor, gear box, shaft, plumber block/ pulley etc. & making proper alignment for smooth operation of the unit.
17Minor Civil Work and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement for R.C.C. work including straightening, cutting, ending, placing in position and binding all complete up to plinth level.1:1½:3(1Cement:1½coarsesand(zone-III):3graded stone Aggregate 20mm nominal size) as per DJB SOR 46.1.2
18Renovation/repairing of modular/combinable polycarbonate insulated outdoor type feeder panel housing (Properties of housing-shock proof, weatherproof, rustproof, UV resistant, halogen free, silicone free, rrosion proof, protection class: ll safe, IP 65 rating, totally insulated, having internal embedded gasket with provision of cable entry through glands. The panel board should have following control panel MCB and accessories etc. complete with connections & Interconnections etc. as required. The Panel is consist of the followings:-a) 18 A, TP, power contactor (MNX 18, L&T) - 1 No.(b) 1 NO + 1 NC side mounting add-on aux. contact block (L&T)-1 No. (c) 6-10 A thermal over load relay (L&T) -1 No. (d) Single phasing preventer (L&T) - 1 No. (e) 16 A, FP, 10 kA, MCB (L&T)-1 No.(f) LED indicating lights red, Yellow, Blue& green (L&T) - 6 os.(g) Push Button with element (L&T) - 2 Nos. (h) 6 A SP MCB (L&T)-1 No. (i) 32 A, 3 way open connector - 1 No.(j)Digital 3 phase VAF meter (L&T)-1 No.(k)50/5 A, 5 VA, 5.0 class current transformer (AE)- 3 No. (1)32 A, 3 y open connector-1 No. Make-All DJB approved applicable. Make the panel fully functional after rectifying the fault by replacement of above components whichever is needed in the panel.
19Painting of gear box, motor, foundation, electric panel mounting and M. S Jaal on Well, etc. and all other MS structure new with 2 coats of primer and then 2 coats of synthetic enamel paint on new and old structure of suitable colour & testing & commissioning of complete flash mixer.

AI Tender Summary

OUR REF NO 49575055
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 16-06-2025
Authority
Authority Name Delhi Jal Board
Work Description Repairing Of Flash Mixers, No-11And12 At 3Rd Filter House At Wazirabad Water Works.
Basic Detail
Tender No NIT No. 04 (2025-26)
Bidding Type Tender
Location
City wazirabad
State Delhi
Key Dates
Publish Date 09 Jun 2025
Submission Date 16 Jun 2025
Open Date 16 Jun 2025
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 17900
Exemption Not Available
Document List
NIT4.5.pdf
Tendernotice_1.pdf
ca65162f-e4d6-4be3-80d0-2645885a454c.html
BOQ_359676.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 09, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 16, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 16, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
5

NIT4.5.pdf

pdf

Tendernotice_1.pdf

html

ca65162f-e4d6-4be3-80d0-2645885a454c.html

xls

BOQ_359676.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders