Housing Urban and Rular Development Government Departments Closing in 0 days TDR #49573101

Tender For Construction Of Four Transit Hubs Cum Community Complex (Thccs) In Singtam-1 (Lot - 1), Tadong (Lot - 2), Soreng (Lot - 3) And Geyzing (Lot - 4) Sikkim

Issued by Government Departments · gyalshing, Sikkim
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Jul 2025
0 days left
EMD
65.10 Lakhs
Bank guarantee accepted
Document Fee
29500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
gyalshing → Sikkim
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction of Four Transit hubs cum community complex (THCCs) in Singtam-1 (Lot - 1), Tadong (Lot - 2), Soreng (Lot - 3) and Geyzing (Lot - 4) Sikkim

BOQ

Name of Work: Construction of Four Transit hubs cum community complex (THCCs) in Singtam-1 (Lot - 1), Tadong (Lot - 2), Soreng (Lot - 3) and Geyzing (Lot - 4) Sikkim.
Sl. No. Item Description
1Lot-1: Singtam-1 THCC Schedule-1
2Conducting topographical surveys and ground profiling of the service area, including preparation of drawings, geotechnical investigations, civil/structural design and associated drawings, as well as electrical, mechanical, and instrumentation design and drawings. This also encompasses the creation of as-built drawings, validation of structural design by a reputable government institution (e.g., IIT/NIT or as approved by the Employer\"s Representative), comprehensive documentation, and execution of other tasks in accordance with technical specifications and the directives provided by the Employer\"s Representative.
3Lot-1: Singtam-1 THCC Schedule-2: Other than Parking, Community & Commercial Centre, THCCs will be used as Emergency Relief Centres, THCC will also accommodate Toilets with EWCD features and have dedicated facility rooms for women. The areas are maked in drawing provided in Volume IV.
4Preparatory Works: Clearing grass and removal of the rubbish upto a distance of 50m outside the periphery of the area cleared.
5Earth Work: Excavation in hilly area in ordinary rock not requiring blasting by mechanical means including cutting and trimming of slopes and disposal of cut material with all lift and lead upto 1000 metres.
6Earth Work: Excavation in hilly areas in hard rock not requiring blasting, by Manual means including trimming of slopes and stacking of 60% of cut material with all lifts and lead upto 50 metres.
7Carriage of Excavated Earth Cost of Haulage Excluding Loading & Unloading On Surface Road- For 20 KMs.
8Filling Works: Providing and laying hand packed stone soling in buildings works with clean hard selected stones,all complete ( Manual Means).
9Plain Cement Concrete: Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete. 1:2:4.
10Water Proofing: Providing integral water proofing compound in mixture of Cement Concrete/Reinforced Concrete/Cement Mortar @200ml per 50kg of cement in accordance to IS:2645 and IS:9103 standards for water proofing of concrete and sand cement mortar in the part/portion of structures subjected to ingress of water/moisture like basements, roofslabs, water tanks& water retaining structures, external plastering, bathroom sand balconies, sump sand drains etc(Dr fixit pidi proof LW+/ Perma Plast-O-Proof/ Endura E160/AquaplastWPL/WeberMixIL/equivalent) (ONLY FOR CAST IN SITU NOMINAL MIXES).
11Reinforced Cement Concrete
12Providing M-30 grade concrete instead of M-25 grade BMC/RMC.(Note:-CementcontentconsideredinM-30is@340kg/cum)For all Height.
13Providing and Laying in position specified grade of reinforced cement concrete excluding the cost of form work,finishing and reinforcements. 1:1.5:3 Mix (1 cement, 1.5 coarse sand 3graded stone aggregate 20mm and down nominal gauge).
14Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand).
15Form Work: Providing, fixing & removing form work for casting R.C.C items as indicated below: with imported timber from outside the state)
16Beam, lintels, girders, brersumers and cantilevers.
17Foundation, footings, base of column etc for mass concrete.
18Wall.
19Floor slab, roof slab, landing, balcony and access platform.
20Square columns.
21Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
22Reinforcement: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
23Masanory Works
24Providing and Laying first class brick work in one brick thick in super structure of standard size bricks with 1:5cement mortar(1 cement and 5 clean coarse sand)as per the direction of Engineer in Charge including curing etc all complete.
25Providing and laying first class brickwork in half brick thick in super structure of standard size bricks with 1:4 cement mortar (1 cement and 4 coarse sand)including carriageofbricks up to work site, curing etc all complete.
26Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
27Plastering
28Providing and Laying 12mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing complete. 1:4 mix.
29Providing and Laying 15 mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing complete. 1:4 mix.
30Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
31Flooring
32Providing and Laying flooring with granite marble stone slabs 20mm thick granite stone slabs flooring of size not less than 1.0 sqm of 20mm thick laid over 20mm (average) 1:4cm thick bare laid cement concrete and joint treated with white cement, mixed with matching pigment.
33Providing and Laying white or colored glazed tiles of size 200mm x 300mm of plain/normal prints colours(white, grey, ivory, platinum, cream, glacier white,summers and, beach, wood duro, melody, or equivalent) in skirting, risers of steps and Dados on 12mm thick cement plaster (1cement, 3coarsed sand) 1:3 bare and jointed with white cement slurry.
34Providing & Laying white or colored glazed vitrified tiles of Orient / Somani or equivalent colour in flooring,treads of steps landing etc laid on a bed of 15mm, cm 1:3 finishedwith white cement slurry.
35Providing and Laying kota stone slabs 25mm thick in Risers of steps, skirting dado and walls laid on 12mmthick (average) thick base of c.m. 1:3(1cement,3coarsesand)and jointed with grey cement slurry mixed with pigments to match the shade of theslab including cutting, rubbing and polishing complete.
36Extra for Nosing for Kota Stone For Treads.
37Painting
38Providing and distempering with oil bound washable acrylic distemper two or more coats of approved brand or manufacture over a coat of cement primer to give an even shade on new surface including preparation of surface etc complete.
39Providing and painting with acrylic exterior paints of quality and make equivalent to EXCEL, WEATHER SHIELD to give an even shade including brushing the surface clean of dirt, dust etc and sand papering and filling the scratches complete on New surface.
40Doors and Windows
41Providing fitting and fixing water proof flush doors shutters, solid block hard core construction with frame of 1st class hard timber, with well matched 3mm commercial plyincluding hinges with screws complete.- 32mm.
42Providing and fixing Piano hinges 35mm wide and 1mm thick with necessary screw etc complete. - M.S finished either with brass plating or nickel plating .
43Providing,fitting and fixing .sliding door bolts with nuts and screws etc. complete.- Size 300x16mm -Brass (Chromium Plated).
44Providing and fixing tower bolts 300x10mm (Barreltype) with necessary screws etc complete.- MS.
45Providing fitting and fixing rolling shutters of approved make, made of required size MS laths interlocked together through their entire length and joined together at the end by end lock mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including providing and fixing wire springs grade No2 andMS top cover of required thickness of rolling shutters as per the direction of Engineer-in-Chargeall complete.
46Providing and fixing glazing in Al .doors and windows ventilaor shutters and partitions etc. with PVC/neosprenegasket with CP brass/stainless steel screws etc. completeas per architectural drawings and direction of Engineer - in- Charge.
47Providing and fixing anodized aluminum works for doors, windows, ventilators and partitions with extruded built up standard tubular or other section of approved make confirming IS733 and IS1285, fixed with rawl plugs and screwsfilling up the gaps at junctions, at top, bottom and sides with required PVC/neoprene felt,etc.Al.section shallbesmooth , rust free.
48Water Supply and Sanitation
49Providing, Fitting and fixing GI pipe (HEAVY DUTY), (excluding trenching, refilling, compacting and the cost of fittings) all complete - 80 mm dia G I pipe.
50Providing, Fitting and fixing GI pipe (Medium Class), (excluding trenching, refilling, compacting and the cost of fittings) all complete - 15 mm dia G I pipe.
51Providing,fittingandfixingwhitevitreouschinapedestal(Europeantype)watercloset(W.C pan with seat and lid, with C.P. brass hinges, 10ltr lowlevel cistern with fittings and brackets 40mm flush bend with specials,all complete: W.C.pan European Bidet sstandard CAT NO 30001.
52Providing,fitting and fixing.white vitreous white chinawashflat backbasin with CI brackets,painted,15mm CP brass pillar taps, CP brass chain with rubberplug, 32mm CP brass wastepipe ,leador PVCconnection 32mm dia CPbrass capandunions, complete including cutting and making good thewalls wherever required. HINDWARE/Simpola or equivalent. One wash basin with one pillar cock 63x45CM.
53Providing,fitting and fixing white vitreous china flat back or wall cornerty pelippedfront urinal basin of size 440x315x325mm with 5ltr automatic flushing cistern with C.I .brackets, GI flush pipe and spreaders with brass unions and G.I.clamps including cutting and making good the walls and floors as required all complete.
54Providing, fitting and fixing soil, waste and vent pipes including testing etc complete. PRINCE / SUPREME or equivalent soil pipe.
55160mm Dia.
56100mm Dia.
57Providing, Fitting and fixing Chromium plated fittings of approved quality and size complete: (ESCO ORIGINAL or Equivalent).BIB COCK -15mm Dia.
58Providing and fitting chromium plated toilet paper holder including the making holes and fixed to timber cleats with CP screws washer etc. all complete.
59Providing, fitting and fixing Beveled gauge mirror of superior glass with 6mm A.C. sheets ground and fixed to timber cleatswith CP screws, washer etc complete.
60Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken 300 mm height including rounding of junctions of for final test.“All above operations to be done in order:With average thickness of 120 mm and minimumat khurra as 65 mm.
61Miscellaneous
62Providing Passenger Lifts with Power operated centre opening doors and AC Variable Voltage & Variable Frequency Control- Capacity of 16 persons and Travel Height upto G+8.
63Providing Goods Lifts with Power operated centre opening doors and AC Variable Voltage & Variable Frequency Control- Capacity 3 Ton and Travel Height upto G+8.
64Providing Fire Fighting System with wet rise and Sprinkler System and automatic Alarm System.
65Providing box drain of30cm(ht)x45cm (width) internal dimension with 1:2:4 Plum concrete (20mm & down) inside walls thickness of 23cm (hillside) and 30cm (roadside) and 1:3:6 (20mm & down) base concrete of thickness of 15cm with standard specification over 15cm stone soling including providing & laying guard stones complete, as per the direction of the Eng.
66Rain Water Harvesting.
67Building Management Plan
68Supplying, installation, testing and commissioning of IP Based CCTV system for building security comprising of PTZ Fixed camera, cabling, recording , display system and hard ware software support- for indoors only, CCTV coverage should be limited to 15%of total plinth Area.
69For External surveillance- total Plot area- plinth area at ground level.
70Providing and placing on terrace high density polyethylene water storage tank with man hole lid and suitable locking arrangement including making holes for inlet, outlet and ball cock including testing etc. all complete: (Sintex or equivalent)- 2000 Litre.
71Supplying, installation, testing and commissioning of STP/ETP of appropriate technology including Civil Works (except plant room), Tertiary Treatment etc. for the Building/ campus.
72Supplying, installation, testing and commissioning of LED Street/ Compound/ High mast/ Pathway/ Landscape Lighting for the entire Campus. (for Total plot Area)
73Sensor based car parking system with controller, display etc. as required. (Cost based on minimum car quantity of cars).
74Carriage & Haulage
75Head load of stock materials for a distance beyond 30m and within 100m distance.
76Head load of non-stock materials for a distance beyond 30m and within 100m distance.
77Head load of stock materials for a distance beyond 100 m for every additional 1000 m.
78Head load of non-stock materials for a distance beyond 100 m for every additional 1000 m.
79Loading and Unloading of Stone Boulder/Stoneaggregates/Sand/Kanker/ Moorum.
80Loading and Unloading of Cement or steel by Manual Means.
81Cost of Haulage Excluding Loading and Unloading Surface Road.
82Sand, Aggregate & Stone-60 Km
83Cement, Steel-90 Km
84Reinforcement
85Apply thoroughly mixed Re Arm Bond 4031 adhesive on both the sides of the joint onto the well prepared substrate by using a suitable trowel. • If the concrete substrate is damp, work the adhesive well into the substrate with a brush. • The thickness of adhesive layer should not be less than 1mm – 1.5 mm and the bonding width on each side of the joint should be at least 50 mm BOTH SIDE on 15 cm wide tape (Gap size 50mm width), .• Fix the Seal Arm Tape TPE on the adhesive within the open time of the adhesive. • Press the tape firmly and without trapping air into the adhesive by using a suitable roller. • The adhesive should be squeezed out on both sides of the tape by ~ 5 mm. • The base layer of the Re Arm Bond 4031 Adhesive achieve initial set before the top layer is applied.
86Providing and fixing 1mm thick & 400mm width aluminium strips over the treated area as per drawing.(For Vertical Areas).
87Providing and fixing 2 mm thick 400mm width aluminium strips over the treated area as per drawing. (For Horizontal Areas).
88Eco Screed (35-40mm) along with Lane Marking with Flo Arm Coat EC
89Providing Screed Layer: 300 mlBONDING AGENT max. with 20 litres water in 50 kgs Ordinary Portland cements Grade 43/53. This covers approx. ≥ 25 m², depending on the porosity and other aspects of the substrate.
90Providing Screed ECOcompatible with OPC 43 or 53 grade cements in accordance with IS8112.
91Providing Lane Marking Primer
92Providing lane marking Coat
93Alluminium sheeting fixed with encapsulated lens type reflective sheeting including 2% toward slettering, cost of angle iron, cost of drilling holes, nuts, bolts etc. and signs as applicable.
94Supplying, installation, testing and commissioning of LAN System comprising of Core switches & L2 switches with 10 G, 10 Giga SFP modules, WIFI Access points, WIFI controller, Network Management Software, Racks, CAT 6A cable, Patch Panels, OFC etc. Rates Applicable on Plinth Areaexcluding service/common Areas.
95Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
96Supplying, fabricating, fitting and fixing steel tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shape washer etc .
97Providing, fitting, fixing of 24 BWG Pre-painted HULASsheet roofing with lapping of 150mm (two corrugation)with G.I. hooks, bolts and nut 8mm dia with bitumen, GI limpet washersincluding carriage all complete.
98Providing and fixing 15cm wide 45cm overall semicircular Pre-painted HULAS. sheet (Class I) gutter with iron brackets 40x3mm size, bolts filled with epoxy etc including making, connection with rain water pipes.
99Providing fitting fixing ridges or hips of 60cm overall width of plain 24BWG prepainted (HULLAS Sheet fixed with G.I, J or L hooks bolts & nuts 8mm dia filled withepoxy in each bolts (8to10 gm per bolt), Limpets, Bitumen washers etc. all complete.
100Providing fitting and fixing 30cm deep 24 BWG Pre-painted HULAS sheet eaves board including (50x25mm)dressed sal timber beading and M.S. rod brackets all complete.
101Demolition of Existing Buildings including stacking of servicable material and dispose dimolition waste up to 20 Kms
102Supply , Installation and Commissioning of of Solar GIRTPV systemwith Solar PV modules, Solar Inverterincluding Cables, Earthing System,AL rail type MMS, IIP, etc.)
103Providing Three Seater Waiting Area Chair set at Ground Floor. Material of Chair Should be Carbon Steel and Weight of one set Should be in between 325Kg to 350 Kg. Dimensions Should be : Length (70 inches), Width ( 23 inches), Height ( 31 inches);Color: Shining Silver.
104Developing Green Wall (Vertical Garden) on Front and Both sides Elevation with PVC Components (Front Panel, Side Panel, Stablizers, Hanging Hook, Bottom Drainage Tray and Geo-Textile Pouch) Including Planting outdoor Plants Like Peperomia, Syngoniums, Philodendron, Epipremnum, Begonia, Anthuriums, Nephrolepis, Chlorophytum, Lantana, Pilea, Rheo discolor, Cuphea, Fittonia, Spathiphylum, Schefflera etc suited to the climate of Sikkim- For only Four Parking Floors
105Providing Public Adress System of Bosch or Equivalent Make with Wireless Mike and 240w Amplfier
106Providing Signages of 7mm Alluminium Plate of Size 12inchX 5 Inch on Each Floor
107Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) - 550mm Dia Pile
108Providing 3 Sets of Two number PVC Dustbins (One Green & one Blue) having Capacity of 240 Litres each, at Each Floor
109Providing and installing 1.5HP Water Pump having Maximum Discharge of 3360 LPM and Head upto 45 meters. Rated Voltage-220V and Rated Frequency 50 HZ (One working & one Standby)
110Providing Oil & greese Trap for Storm water Drains
111Providing Stainless steel commercial food waste disposer, fully digested with inbuilt shredder. No emission of harmful gases. No enzymes should be used- capacity-175Kg/day
112Lot-1: Singtam-1 THCC Schedule-3
113INTERNAL WIRING
114Wiring for light/Fan/Call bell & 6 A plug point with 2x1.5 sqmmFRLSHPVC insulated copper conductor single core cable in best quality recessed alkathine pipe and earthing the point with 1x 1.5 sqmmHR FRLS PVC insulated copper conductor single core cable as required.
115Wiring for 16 A plug point with 2x 2.5 sqmmFRLSH PVC insulated copper conductor single core cable in best quality recessed alkathine pipeand earthing the point with 1x 2.5 sqmmFRLSH PVC insulated copper conductor single core cable as required.
116Wiring for sub-main for light/fan/call bell & 6 amps plug points with 2x 2.5 sqmmFRLSH PVC insulated copper conductor single core cable in best quality recessed alkathine pipe and earthing the point with 1x2.5 sqmm FRLSH PVC insulated copper conductor single core cable as required.
117Wiring for sub-main for 16 amps (2x1000W) plug points with 2x4.0 sqmm FRLSHPVC insulated copper conductor single core cable in best quality recessed alkathine pipeand earthing the point with 1x4.0 sqmm FRLSH PVC insulated copper conductor single core cable as required.
118Wiring for sub-mainwith2x 6.0 sqmm FRLSHPVC insulated copper conductor single core cable in best quality recessed alkathine pipeand earthing the point with1x 6.0 sqmmFRLSH PVC insulated copper conductor single core cable as required.
119Wiring for mainwith 2x 10.0 sqmm FRLSHPVC insulated copper conductor single core cable in best quality recessed alkathine pipeand earthing the point with 1x 10.0 sqmmFRLSH PVC insulated copper conductor single core cable as required.
120SWITCH,SOCKET & ACCESSORIES: Supplying & fixing 06 amps 1 way FT switch on white moduler plate and metal flux box including connection etc. as required.
1214 no. 06 amps FT switch with 1 no white 4 moduler plate and 4 moduler metal flux box.
1226 no. 06 amps FT switch with 1 no white 6 moduler plate and 6 moduler metal flux box.
1238 no. 06 amps FT switch with 1 no white 8 moduler plate and 8 moduler metal flux box.
124Supplying & fixing 1 no. 16 amps socket, & 16 amps switch,white plate (4 module) & Metal flux box (4 module)includingconnection etc. as required.
125Supplying & fixing 1 no. 06 amps socket with 1no. 06 amps switch, 1 no. 3 module white plate & 1 no. 3 module metal flux box ) including connection etc. as required.
126Supplying & fixing 1 no. fan step regulator 120 watts, 1 no. white plate (2 module) and 1 no. (2 module) metal flux box including connection etc. as required.
127LIGHT FITTINGS
12820watts Sleek surface Down light slim profile surface mounted down light
129LED tube light cadila plus 20 watt
1306 watt LED up-down hexa/penta/round/square accent lightning.
131LED Flood Light 60 watt
132LED 15 watt Pyramid square
133Ceiling Fan 1200mm48\" (Havells/USHA) Conforming to IS: 374
134Ventilating fans 300mm 12\" (Havells)
135Heavy duty Exhaust Fan 12\" (Havells)
136DISTRIBUTION SYSTEM
137Miniature Circuit breakers (MCB) Single pole 240V6 - 32 Amps
138Miniature Circuit breakers (MCB)Four pole 40 Amps
139Miniature Circuit breakers (MCB)Four pole 63Amps
140MCB DB (Triple pole & neutral) Double door6way
141MCB DB (Triple pole & neutral) Double door8way
142MCB DB (Triple pole & neutral) Double door12way
143Safe earthing T-19 model 50 mm diameter x 2 mtrs. Electrode (Copper bonded) & One bag backfill chemical compound.
144Copper strips 25mm X 5mm from Cu. plate earth electrode
145Alkathene pipe 1/2\", 3/4\", 5/8\"&1\" (Bardia)
146PVC Tape
147L.T DISTRIBUTION LINE
148L.T distribution switch board with copper bus bar, out-door type Kiosk, having electrolytic annealed copper bus bar 50x12mm for phase & 50x6mm for neutral circuits mounted on glazed porcelain or Bakelite base & fitted with voltmeter, ammeter, selector switches for ammeter & voltmeter, electronic KWH meter, indicating lamps cabin light, fabricated with 12 gauge M.S plain sheet, painted with anti- rust primer & two coats of Epoxy paint of shade 631 as per IS: 8623-1, front opening doors with gasket & locking arrangement complete with following incoming & outgoing controls:INCOMING:1 No. 100 A, 4P,50KA, MCCBOUTGOING: 3 Nos. 63A FP MCCB, 35 KA, & 1 No. 32A FP MCCB, 35 KA all with built in Thermo Magnetic Release.
149L.T distribution switch board with copper bus bar, out-door type Kiosk, having electrolytic annealed copper bus bar 50x12mm for phase & 50x6mm for neutral circuits mounted on glazed porcelain or Bakelite base & fitted with voltmeter, ammeter, selector switches for ammeter & voltmeter, electronic KWH meter, indicating lamps cabin light, fabricated with 12 gauge M.S plain sheet, painted with anti- rust primer & two coats of Epoxy paint of shade 631 as per IS: 8623-1, front opening doors with gasket & locking arrangement complete with following incoming & outgoing controls:INCOMING:1 No. 63 A, 4P,50KA, MCCBOUTGOING:OUTGOING: 2 Nos. 40A FP MCCB, 35 KA, & 1 No. 32A FP MCCB, 35 KA all with built in Thermo Magnetic Release.
1503.5 core 95 sqmm 1.1 KV XLPE Insulated Heavy Duty Power Cable for working voltage upto & Including 660/1100 Volts Armoured Aluminium conductor.(Havells make or equivalent)
1513.5 core 35 sqmm 1.1 KV XLPE Insulated Heavy Duty Power Cable for working voltage upto & Including 660/1100 Volts Armoured Aluminium conductor.(Havells make or equivalent)
152CF54/100GC Cable Tray GC (Hot dip)
153Coupler for jointing two cable trays (coupling kit )
154Cablofil bolt cutter
155L.T. 1.1 KV heat shrinkable outdoor End Termination Kit for 3.5 X 95 sqmm PVC/XLPE cables 2,3 & 1/2 core conforming to IS:13573 (Dension or equivalent)
156L.T. 1.1 KV heat shrinkable outdoor End Termination Kit for 3.5 X 35sqmm PVC/XLPE cables 2,3 & 1/2 core conforming to IS:13573 (Dension or equivalent)
157Safe earthing T-19 model 50 mm diameter x 2 mtrs. Electrode (Copper bonded) & Onebag backfill chemical compound.
158Copper strips 25mm X 5mm from Cu. plate earth electrode
159Alkathene pipe 1/2\", 3/4\", 5/8\"&1\" (Bardia)
160STREET LIGHTS
1618.5 Mtrs. Long 410-SP-18 swaged type steel tubular pole with CI base plate & cap, double part ( Nuts & bolts type) working load 120 Kgs
1622 Core x 16 sqmm 1.1KV PVC/XLPE heavy duty power cable for working voltage upto & including 660/1100 volts Aluminium armoured conductor.
1632.5 sqmm. ISI markedSingle core PVC insulatedindustrial Gradecopper conductor flexible cable, 1100volt
1642\" dia flexible super PVC green pipe 3.5kg/cm2
16572Watt LED Street light fittings conforming to IS:16101
166Polycarbonate junction box with bus bar arrangement and 6 Amp MCB (Street lights)
167Miniature Circuit breakers (MCB)Double pole 40 Amps
168Astro time switch
169Safe earthing model T-19, short time current 20 ka rms for 1 sec (LV/MV) application, 50 mm dia x 2 mtrs electrode & one bag fill chemical compound).
170Copper wire 6/8 SWG for earth looping system
171Alkathine pipe 1\"
172Aluminum thimblebullet 16sqmm
173Red Oxide Metal Primer (Nerolac or Equivalent) conforming to IS: 2074
174Aluminum Paint (Nerolac or Equivalent) conforming to IS: 2339
175Concreting of 8.5 Mtrs. Swaged Steel Tubular Pole in 1:4:8 cc in 0.9x0.9x1.50 mtrs Pit, Construction of parapet 0.35 x 0.47x0.153 mtrs. In 1:3:6 cc i/c 12mm cement plaster of parapet in 1:4 Mix.
176Excavation of 0.45x0.90x1.00mtrs. Cable trench in mix soil & re-filling with available excavated earth & providing cement concrete on the top of the trench.
177Supply, Installation, testing & commisioning of 500KVA DG sets,AMF Panel, bus ducting/Cables from DG set to essential panel, DG set enclouser room sound insulation/ventilation/smoke exhaust as required,earthing of DG Set system,control cabeling,fuel tank/piping, DG set exhasut piping/exhaust chimney as per CPCB norms. Civil works connected with DG set including foundation as required PAR CPWD 2021 , ITEM NO. 6.3.1
178EXTERNAL ELECTRIFICATION: INSTALLATION OF 630 KVA DISTRIBUTION TRANSFORMER.
17911 Mtrs steel lattice structure of 65x65x6 mm M.S. angle complete with nuts & bolts (without arms)
180M.S.channel ISLC 75(75x40x6mm) X 2.8mtr. for supporting line, G.O.S & D.O fuse etc(SAIL Brand)
181M.S angle 50x50x6 mm for holding the MS Channel
182M.S.bolts & nuts 16mm dia x 40 mm length full thread.
18350 HZ , DYN 11,3 phase , ONAN cooled , outdoor type 500 Kva , 11/0.433 KV, copper wound distribution transformer with off-circuit tapping +2.5%, +5% , on H.V side with bare bushing on HV & LV side &provided with standard fittings and accessories with first filling of transformer oil conforming to IS: 1180(PART -I) 2014: Energy efficiency level 2
1843C X 70 sq mm11 KV ( Uo) / 11 KV(U) XPLE Insulated armoured cable with aluminium conductor conforming to IS:7098 PART-2
185Heat Shrinkable outdoor type end termination kit 3 C X 70 sqmm EPKT 3352 for 6.35 Kv/11 Kv (U) 3 core XLPE (Kit no. EOKT 3332-3382) Raychem make or equivalent
1861.1 Kv PVC / XLPE insulated heavy duty power cables 3.5 core X 400 sqmm for working conforming to IS: 7098 Part -I
187L.T. 1.1 KV heat shrinkable outdoor End Termination Kit for 3.5 X 400 sqmm PVC/XLPE cables 2,3 & 1/2 core conforming to IS:13573 (Dension or equivalent)
188800A L.T. Distribution switch board with copper bus bar, outdoor type Kiosk,having electrolytic annealed copper bus bar 50 X 12mm for phase & 50 X 6 mm for neutral circuits mounted on glazed porcelain or Bakelite base & fitted with voltmeter, ammeter, selector switches for ammeter & voltmeter, electronic KWH meter, indicating lamps cabin light, fabricated with 12 guage M.S. plain sheet , painted with anti-rust primer & two coats of epoxy paint of shade 631 as per IS: 8623-1, front opening doors with gasket & locking arrangement complete with following incoming & outgoing controls. INCOMING:1 No. 800 A, 4P,50KA, MDO ACB.OUTGOING: 4 Nos. 200A TP MCCB , 50 KA, 1 No. 63 A TP MCCB,35 KA all with built in Thermo Magnetic Release .
189Guy assembly complete with7/10 SWGG.I. stay wire,140x85 mm H.T.guy insulator, 18mm dia stay rod 1.8 mtrs.Longwithbowthimble,turnbuckleand300x300x6mm anchor plate.
19011 KV, 3 Pole 400amp, Air Break G.O.S tilting type, three insulator per phase, complete with all fittings conforming to IS:9920 & IS: 9921 (Porcelain/Polymer)
19111KV,3Pole,400amp.D.O.FUnitcompletewithall accessories conforming to IS: 9385 (Porcelain/Polymer)
1929KV,5KAsinglepoleunitmetaloxidegaplessSurge Arrestorfor11KV,50c/ssolidlyearthedneutralsystem confirmingtoIS:3070(part-3)RaychemRPGmakeor equivalent.
193SafeearthingmodelT-39shortcurrent50KArms for 1 sec (EHV) application: 80 mm diameter x 3 Mtrs. Electrode (Copper Bonded) & two bags backfill chemical compound.
194Copper strips 25mm X 5mm from Cu. plate earth electrode
195Danger board 11000 Volts.
196G.I barbed wire for anti climbing device @ 2 kg./pole
197Red oxide metal primer (NEROLAC or equivalent). @2ltrs/pole
198Aluminium paint (NEROLAC or equivalent)[email protected]/pole
199110mm dia Rigid U PVC pipe as per IS 4985-2000 working pressure 6 kgf/cm2 (finolex)
200Total cost of materials (External Electrification)
201Excavation of 0.45x0.9x1.00 m cable trench in mix soil & re-filling with available excavated earth and providing cement concrete on the top of the trench
202Concretingof 11Mtrs.Latticestructurein1:4:8ccin 0.9x0.9x1.75 mtrs. pit, constructionof parapet 0.61x0.61x0.153 mtrs. in 1:3:6 cc i/c 12mm cement plasterof parapet in 1:4 mix.
203Placement of 750 - 1250 KVA distributionTransformer on parapetofsize2.2x2.2x1mtrs.In1:3:6ccMixincluding 12mm thick cement plaster in 1:4 Mix.
204Concreting of H.T guy assembly in 1:4:8ccm in 0.40x0.40x1.05 Mtr.pit.
205Fencingfor500KVAparapetmounteddistributionsub- station of size 3.5x4 mtrs.constructed with 50x50x5mm M.S angleverticalprops,35x35x6mmM.Sangle supports(double run), M.S wire mesh, 50x6mm M.S flat iron forclampingwiremeshcompletewithgatewithlocking arrangement, sitedevelopment, concretingof propsin 1:2:4 cc i/c soling & flooring works in 1:4:8 cc as per Layout No. 3/F/E&PD/400-750 KVA.
206Air quality monitoring
207Noise levels monitoring
208Ground Water Quality
209Surface Water Quality

AI Tender Summary

OUR REF NO 49573101
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 15-07-2025
Authority
Authority Name Urban Development Department
Work Description Construction of Four Transit hubs cum community complex (THCCs) in Singtam-1 (Lot - 1), Tadong (Lot - 2), Soreng (Lot - 3) and Geyzing (Lot - 4) Sikkim
Basic Detail
Tender No SIUDP/DRY/THCC-02/2024-25
Bidding Type Tender
Location
City gyalshing
State Sikkim
Key Dates
Publish Date 09 Jun 2025
Submission Date 15 Jul 2025
Open Date 15 Jul 2025
Finance
Tender Value Ref. Documents
Tender Fee 29500
EMD 65.10 Lakhs
Exemption Not Available
Document List
559a726f-be4b-4745-b9ed-e0997e0e642a.html
BOQ_890.xls
ContractdocumentforTHCC2.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 09, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 15, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 15, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

559a726f-be4b-4745-b9ed-e0997e0e642a.html

xls

BOQ_890.xls

rar

ContractdocumentforTHCC2.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders