Tender For E- Quotation For Modular Operation Theatre Items At Sadar Hospital, Jamtara For The Year-2024-25-1 Wall and ceiling cladding (Approved MAKES: JINDAL/TATA/ESSAR) Prefabricated Wall & Ceiling PREFABBICATED MODULAR OPERATING THEATER USING PPGI PUF PANEL (BOTH WALL & CEILING) Providing of pre-Fabricated Modular Operation Theater with PPGI PUF Pannel filled with PUF of 40 kg/Cubic Meter (40D) having required mechanical strength and better thermal Insulation which saves energy cost. The panels joints are properly CAM locked & Revisited which provides a seamless sub- structure which again sanded to a smooth finish. Approx. Thickness for Wall 50 mm, raiser 40 mm. and ceiling 30mm. 2 Laminar Air Flow system SITC of ceiling filtration system 2400 x 2400 mm. The ceiling filtration system shall be 2.40 Meters x 2.40 meters and will be integrated with the adjacent false ceiling. The ceiling shall be constructed with a plenum box supplied with conditioned air from the central system via 8 nos.HEPA filters (european norm EN1822:2009; class H14; DOP 99.97-99.9999% efficincy for 0.3 Micron particles) with pressure drop of 300 pascals at its nominal flow rates (supplied with the Plenum), mounted on the exit from the supply ducting. 3 Conductive Seamless Flooring with Coving on all Corners SITC of Operation theatre flooring (antistaic conductive):2 mm. Full body Conductive Vinyl, laid on a semiconductive adhesive base. The floor finish sholuld terminate at the room perimeter passing over a concealed cove former and continuing up the wall for 100mm. all joints should be weled with electrodes of the same compatible material to provide a continuous sealed surface 4 Hermetically sealed Sliding door System Fabrication Supply, installation, testing & commissioning of sliding type Hermetically Sealed OT door having high density partical board cores, high pressure laminate face on both sides, viewing window 300 x 300mm. Size:1800 x 2100 mm.(Wx H). Automatice Doors: Provided with radar Switch- 2 Nos., Foot Switch Nos. and photocell Sensors (Anti Crush Feature) & as per tech. specs.attached. Automatice Doors Size:(1800 x 2100 mm.) 5 Peripheral Lights 9 Supply installation and commissioning of 42W Bottom Opening Room fixture with IP 65, Led make should be Nichia/seoul<5 SDCM, Own make BIS certified islocated Driver, Flicker free, class2 SELV Driver, Operating Temperature:-100C to 450C Operating Voltage range:140-270V, Surge Protecction >3.5 KV, High effciency driver:80-85%, Low Voltage cut off below 130V, output short circuit protction, Fixture Made up of MS power coated white after phosphochromate treatment provided as standard with sheet thickness of 1.2 mm. diffuser of high impact polycarbonate opal diffuser with thickness 1.5mm for glare freeuniform light distribution, power coating: 60microns, lamp source: high efficiency long life LED package in integral module to ensure better uniformity, Average life L70B50: 50000 hours,THD<10%,95, system efficacy >95-100 Lm/W, CRI>80, IP65, IK05 impact rating, Dimension will be 6 Surgeon Control Panel Supply, installation, testing & commissioning of operation theatre control panel Membrane type:Time day ClockTime Elapse ClockGeneral and RGB Lighting System Conntrol (peripheral Lights and plenum lights with dimming)Medical Gas Alarm panel 5 Gas- low, normal and high pressure with sequencing as per HTM 02 01Hand free Telephone set with SpeakerTemperature & humidity indicator with controllerHEPA filter Status moduleRoom Pressure Indicator/ differential Pressure Indicator 7 X-Ray view Screen Supply installation, testing & commissioning of Twin plate LED Xray Viewing screen: size:940 x 640 x 50 mm. approx with viewing area, two plate X-ray view screen (120W), LED based technology with colour temperature>6000K and lamp life>50,000 hrs and brightness in excess of 4000 lux. 8 Writing White board Supplying & fixing of sturdy writing Operating list board: made of ceramic surface having Magnetic properties and should be flushed to the wall of the operating room size 940mmx 640mmx 50mm 9 Surgeon Pendant Providing & fixing of ceiling mounted single arm pendant systems for surgeon: The weight Carrying capacity of the arm should not be less than 180 kgs. Load. There should be 5 or 6 nos. equipment loading shelves. Double column of 1000mm. Single Arm pivot range minimum 900 mm. or above. the brake (electromagnetic) supplied with indian origin multipin 6/16 amp electrical switch+socket-5nos. it should have 2 no. RJ 45 data socket. It should have provision for 06 gas outlet points2 Oxygen1 SA71CO21 Vacuum Capable of 340 Degrees of rotation. Medical gas terminal units shall be provded by the MGPS vendor and shall be installed in the pendant. USFDA 10 Anesthesia Pendant Ceiling mounted rigid pendant systems for anaesthesia: single arm motorized type pendants Made of Aluminum, powder coateDimensions: Double Vertical Column 1200 mm. Vertical lift:600 mm. Horizontal arms- total 1000 mm. pendant should be prepiped provided with 5 Nos. medical gas outlets. Outlets shall be connected to dual circuit being provisioned for all ozygen 2 outlets. Nitrous oxide 1 outlets Vacuum 1 outlets. medical air 1 outlets AGSS 1 outlet colour coded high pressure tubing for each gas with NIST Connectors at ceiling provided with prewired 10 nos 6/16 amps sockets and two data sockets RJ45 Instrument loanding capacity 180 kgs. Shelves:Two with handle and two rail each with capacity of 40 kgs. Drawers one with handle and twe RailsLoad capacity 40 kgs. Swiveling stainless steel Vertical pole 11 AIR CONDITIONING SYSTEM: AHU supply, installation & Commissioning of Air Handling unit make: VTS (8.5TR) (OUT DOOR UNIT MAKE: BLUE STAR / CARRIER) 12 Aluminum Duction 22 gauge with curves & bends where indicated for easy flow of air tight by applying silicon sealant after fabrication. Hangers will be provided to ducts & will be suspended be means of G.I. coated rod & these with not be more than 2.5 Mtr. apart. Thermal insulation with 19mm. XPE with aluminum foil for supply & 13mm. XPE return air ducts. joints will be lapped with Nitrile tape for better insulation. (Laminar to AHU & Return air in all four corners) AHU to be placed near OT, not more than 6 Meters. 13 Dustbin (trio) 14 Storge Unit: Storge Unit: 1 mm. thick Stainless sheet 304. the storge unit should be divided 4 equal parts and eachpart should have indivdual swing 8 mm. toughened glass door with quality stanless steel self- closing hinges capable of 180 degree swing out and secure locking system. each part will be provided with removable stainless steel racks made from½ circular ( outer diameter) seamless stniless steel 304 tubes of 1 mm. thickness placed at intervals of 1.5 center to center. the overall dimension of the stroge unit shall be 1500 mm. (width) x 2100 mm. (Height) 350 mm. depth being variable to suit architectural layout. 15 Supplying, Installation, testing & commissioning of f floor mounted, scrub station: compact surgical 2 bay scrub sink designed for use in OT complex. Each fixture fabricated from heavy gauge 1 mm. thick type 304 stainless steel of seamless welded construction, polished to a smooth finish with a front access panel which should include, stoppers and strainers. hands free operation should include infra-red sensors with built-in range of adjustment. thermostatic mixing, valve control should be located behind the access panel and maintain constant water temperature. User defined setting of approximately 1 to 3 min should be available. (size 1500mm. X 675mm. X 1105mm. For 2 persons 16 Electrical DB SITC of Electrical Distribution board: should the trandformers, if any, mains failure relays, electrical distrition equipment and circuit protection equipment for all circuits within the operating theatre. All internal wiring should terminate in connectore with screw and clamp spring connections of the clip-on type mounted, on a DIN rail and labelled with indelible propritary lables, Individual fuses or miniature circuit breakers should protect all internal circuits. 17 PRESSURE RELIEF DAMPER Supply, installation, testing & commissioning of SS Fabricated cascade Pressure relief dampers: suitably sized air pressure relief damper should be placed endabling differential room pressure to be maintained.Counter-weight balancing system should be prvided in the PRD to maintain positive pressure inside the operation room 18 C-9001 SUPREME, SLIDING TOP ELECTRIC TABLE 19 LED Operating Light LED Operating light having following specifications:- Maximum luminance (1m): 160,000+160,000 lux at 1 m distance, Electrical power: 150+90W, power consumption 2 x 11 A, Fitting: ceiling anchoring ring ceiling pendant with 2 brackets and 2 spring arms, range of movement: 1 x 3600/ 1 x 3300, Recommended room height at least 2.45 m, Max. ceiling load: 2x 218 nm/650 N, Light body weight 9.2 + 7.5 kgs, light body depth: 1 x 130 cm / 1 x 140 cm, Air shielding surface 2 x 330 cm2 transformers: 2 x 450VA/ 230V/26V, brightness regulator 2 x 20- 500VA (primary Voltage), Provided with 2 sterilisable handles with each done Easy positioning by sterilisable handle, focus adjustable by sterilisable handle, life time of Bulbs: SITC of Electrical Distribution board: should the trandformers, if any, mains failure relays, electrical distrition equipment and circuit protection equipment for all circuits within the operating theatre. All internal wiring should terminate in connectore with screw and clamp spring connections of the clip-on type mounted, on a DIN rail and labelled with indelible propritary lables, Individual fuses or miniature circuit breakers should protect all internal circuits. 17 PRESSURE RELIEF DAMPER Supply, installation, testing & commissioning of SS Fabricated cascade Pressure relief dampers: suitably sized air pressure relief damper should be placed endabling differential room pressure to be maintained.Counter-weight balancing system should be prvided in the PRD to maintain positive pressure inside the operation room 18 C-9001 SUPREME, SLIDING TOP ELECTRIC TABLE Per Pcs 19 LED Operating Light LED Operating light having following specifications:- Maximum luminance (1m): 160,000+160,000 lux at 1 m distance, Electrical power: 150+90W, power consumption 2 x 11 A, Fitting: ceiling anchoring ring ceiling pendant with 2 brackets and 2 spring arms, range of movement: 1 x 3600/ 1 x 3300, Recommended room height at least 2.45 m, Max. ceiling load: 2x 218 nm/650 N, Light body weight 9.2 + 7.5 kgs, light body depth: 1 x 130 cm / 1 x 140 cm, Air shielding surface 2 x 330 cm2 transformers: 2 x 450VA/ 230V/26V, brightness regulator 2 x 20- 500VA (primary Voltage), Provided with 2 sterilisable handles with each done Easy positioning by sterilisable handle, focus adjustable by sterilisable handle, life time of Bulbs: Per Set 20 UV SYSTEM: UV rays are very effective in killing a large number of pathogenic organisms of bacterial, viral and fungi commonly seen in operating theaters such as pseudomonas, clostridium difficile, MRSA and VRE Per Set 21 De- Fumigation System: Fumigation in operation Theatre is a Process of gaseous sterillization that is used for the killing of micro-organisms and prevention of micro-organisms and prevention of microbial grwth in the air, the surface of the wall, or the floor1.000De-fumigation control panel is installed outside the operation theatre to monitor the room pressure and to start the de- fumigation system from outside the operation theatre, It will de-fumigation the theatre in a given time and will switch-om the AHU to increase operation theatre pressure without operating the surgeon control panel Per Set OT CORRIDOR AREA & OT COMPLEX WITH PER AND POST AREA Conductive Seamless Flooring with Coving on all Corners 22 SITC of Operation theatre flooring (antistaic conductive):2 mm. Full body Conductive Vinyl, laid on a semiconductive adhesive base. The floor finish sholuld terminate at the room perimeter passing over a concealed cove former and continuing up the wall for 100mm. all joints should be welded with electrodes of the same compatible material to provide a continuous sealed surface Per Sqm 23 Antibacterial / Antifungal paint Providing and applying antibacterial paint the internal surface of the room walls will be sprayed with water based liquid plastic wall glaze or equivalent anti- bacterial paint, approved by the architect to a mimnimum dry film thickness of 300 microns. The plastic coating will overlap the floor covering ceiling system and doorframes by 25 mm. to provde a continuous sealed surface. the plastice coating will be non- reflective and the colour will be submitted to the architect for approval. Per Sqm